Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real Time Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Computer Vision-Enabled Smart Traffic Monitoring for Sustainable Transportation Management

Transportation accounts for a significant portion of total global energy consumption. Excessive energy consumption usually occurs in urban traffic environments with congestion and travel delays. With the advancement of remote sensing and computer vision technologies, real-time traffic conditions can be monitored. Therefore, sustainable transportation management strategies can be developed to optimize the overall energy and environment performance and reduce congestion and emissions. This work presents a smart traffic monitoring system based on remote camera sensors. Real-time and historical traffic conditions at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) were monitored and analyzed to develop optimal transportation management strategies for sustainability. Computer vision algorithms were developed and applied to process the real-time camera data to obtain complete traffic information across the ORNL campus. Weeks of historical data were collected and processed to analyze the traffic and identify bottlenecks. The proposed traffic monitoring and management approach can be applied and extended to benefit other campuses or urban areas.

Shao, Yunli↗

Closed-Loop Error Learning Control for Uncertain Nonlinear Systems With Experimental Validation on a Mobile Robot

This article develops a closed-loop error learning control (CLELC) algorithm for feedback linearizable systems with experimental validation on a mobile robot. Traditional feedback and feedforward controllers are designed based on the nominal model by using the feedback linearization control (FLC) method. Then, an intelligent controller is designed based on the sliding mode learning algorithm that utilizes closed-loop error dynamics to learn the system behavior. The controllers are working in parallel, and the intelligent controller can gradually replace the feedback controller from the control of the system. In addition to the stability of the sliding mode learning algorithm, the closed-loop stability of an nth-order feedback linearizable system is proven. The simulation results demonstrate that the CLELC algorithm can improve control performance (e.g., smaller rise time, settling time, and overshoot) in the absence of uncertainties, and also provides robust control performance in the presence of uncertainties as compared to traditional FLC method. To test the efficiency and efficacy of the CLELC algorithm, the trajectory tracking problem of a tracked mobile robot is studied in real time. The experimental results demonstrate that the CLELC algorithm ensures highly accurate trajectory tracking performance than traditional FLC method.

97 MATHEMATICS AND COMPUTING↗

TH-AB-202-08: A Robust Real-Time Surface Reconstruction Method On Point Clouds Captured From a 3D Surface Photogrammetry System

Purpose: Surface photogrammetry (e.g. VisionRT, C-Rad) provides a noninvasive way to obtain high-frequency measurement for patient motion monitoring in radiotherapy. This work aims to develop a real-time surface reconstruction method on the acquired point clouds, whose acquisitions are subject to noise and missing measurements. In contrast to existing surface reconstruction methods that are usually computationally expensive, the proposed method reconstructs continuous surfaces with comparable accuracy in real-time. Methods: The key idea in our method is to solve and propagate a sparse linear relationship from the point cloud (measurement) manifold to the surface (reconstruction) manifold, taking advantage of the similarity in local geometric topology in both manifolds. With consistent point cloud acquisition, we propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, building the point correspondences by the iterative closest point (ICP) method. To accommodate changing noise levels and/or presence of inconsistent occlusions, we further propose a modified sparse regression (MSR) model to account for the large and sparse error built by ICP, with a Laplacian prior. We evaluated our method on both clinical acquired point clouds under consistent conditions and simulated point clouds with inconsistent occlusions. The reconstruction accuracy was evaluated w.r.t. root-mean-squared-error, by comparing the reconstructed surfaces against those from the variational reconstruction method. Results: On clinical point clouds, both the SR and MSR models achieved sub-millimeter accuracy, with mean reconstruction time reduced from 82.23 seconds to 0.52 seconds and 0.94 seconds, respectively. On simulated point cloud with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent performance despite the introduced occlusions. Conclusion: We have developed a real-time and robust surface reconstruction method on point clouds acquired by photogrammetry systems. It serves an important enabling step for real-time motion tracking in radiotherapy. This work is supported in part by NIH grant R01 CA169102-02.

60 APPLIED LIFE SCIENCES↗

BTO 3.1.2.55 Milestone Report – Report of Literature Review for Maldistribution in Heat Exchangers

In this quarter, a comprehensive review of the literature was performed to understand the effects of flow maldistribution and current efforts to improve performance through flow control. Nearly all systems have some degree of maldistribution on either the air-side, refrigerant-side, or both. Air-side maldistribution was found to have a greater impact on heat exchanger performance compared to refrigerant-side, but both sides of the system are important to consider when developing solutions. Up to a maximum of 65% capacity loss was reported in large commercial systems due to air-side maldistribution. Microchannel heat exchangers are becoming more widespread due to their efficiency and size but are even more prone to maldistribution than conventional fin-tube heat exchangers. Current solutions tend to focus on optimizing header design and refrigerant circuitry to improve performance. Several active control methods, such as hybrid control, have been explored to control refrigerant flow in real time, but there is a need for an adaptive yet cost effective system which can optimize performance in changing conditions.

42 ENGINEERING↗

Analog Computing for Science

Conventional digital computing faces fundamental physical limits: large scale computing systems already con sume tens of Megawatts of power, Dennard scaling has ended, and data movement costs dominate application performance. Next generation experimental facilities generate data at rates that overwhelm conventional pro cessing and demand real-time analysis at the source. Analog computing, which exploits the continuous dynamics of physical systems to perform computation, promises a transformative path toward orders-of-magnitude gains in energy efficiency and time-to-solution for scientific workloads.

97 MATHEMATICS AND COMPUTING↗

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗

A Novel Approach for Real-Time Quality Monitoring in Machining of Aerospace Alloy through Acoustic Emission Signal Transformation for DNN

Gamma titanium aluminide (γ-TiAl) is considered a high-performance, low-density replacement for nickel-based superalloys in the aerospace industry due to its high specific strength, which is retained at temperatures above 800 °C. However, low damage tolerance, i.e., brittle material behavior with a propensity to rapid crack propagation, has limited the application of γ-TiAl. Any cracks introduced during manufacturing would dramatically lower the useful (fatigue) life of γ-TiAl components, making the workpiece surface’s quality from finish machining a critical component to product quality and performance. To address this issue and enable more widespread use of γ-TiAl, this research aims to develop a real-time non-destructive evaluation (NDE) quality monitoring technique based on acoustic emission (AE) signals, wavelet transform, and deep neural networks (DNN). Previous efforts have opted for traditional approaches to AE signal analysis, using statistical feature extraction and classification, which face challenges such as the extraction of good/relevant features and low classification accuracy. Hence, this work proposes a novel AI-enabled method that uses a convolutional neural network (CNN) to extract rich and relevant features from a two-dimensional image representation of 1D time-domain AE signals (known as scalograms), subsequently classifying the AE signature based on pedigreed experimental data and finally predicting the process-induced surface quality. The results of the present work show good classification accuracy of 80.83% using scalogram images, in-situ experimental data, and a VGG-19 pre-trained neural network, establishing the significant potential for real-time quality monitoring in manufacturing processes.

36 MATERIALS SCIENCE↗

AutoFocus: AI/ML-driven real-time wavefront diagnostics to autonomously align and optimize X-ray optics

We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Hardware-in-the-Loop Using Electromagnetic Transient Simulation

Digital real time simulators have the capability to run electromagnetic transient simulations in real time. This capability allows users to leverage the hardware-software combination to evaluate controller performance, protection device performance, and power device performance. This has helped many field deployment projects to be successful and be cost-effective. In this talk, we will present current state-of-art, and future of real time electromagnetic transient simulation and its impacts on field deployment.

08 HYDROGEN↗

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Performance of Gaussian Plume and Backward Lagrangian Stochastic Models for Near-Field Methane Emission Estimation Using a Single Controlled Release Experiment

Methane (CH 4 ) is a major component of natural gas and a potent greenhouse gas. Increasing atmospheric methane concentrations are attributed to emissive anthropogenic activities by an average of 13 ppb per yr since 2020 and are linked to a changing global climate. Mitigating CH 4 emissions from oil and gas production sites has recently become a target to reduce overall greenhouse gas emissions; however, monitoring the efficacy of mitigation strategies depends on accurate quantification of CH 4 emissions at the facility-level. Near-field quantification of methane (CH 4 ) emissions from oil and gas (O&G) facilities remains challenging due to the effects of atmospheric variability and sensor configuration on atmospheric dispersion models. This study evaluates the performance of two atmospheric dispersion models, the Gaussian plume (GP) and backward Lagrangian stochastic (bLS), by comparing calculated CH 4 emissions to controlled single-point emissions between 0.4 and 5.2 kg CH 4 h −1 . Emissions were calculated by both models using 121 individual sets of measurements comprising five-minute averaged downwind methane mixing ratios and matching meteorological data. The comparison shows that the bLS approach achieved a higher proportion of emission estimates within a factor of two (FAC2) of the known emission rates compared to the GP approach. The emissions calculated by the bLS model also had a lower multiplicative error and reduced bias relative to GP. Other error-based metrics further confirmed the bLS model performed better, as it yielded lower RMSE and MAE than GP. Statistical analysis of the emission data shows that the lateral and vertical alignment of the source and the sensor plays a critical role in emission estimations, as measurements made closer to the plume centerline and at a distance between 40 and 80 m downwind yielded the best FAC2 agreement. High wind meander degraded the ability of both approaches to generate representative emissions, particularly with the GP approach, as it violates the modeling approach’s assumption of steady-state emissions. Data suggest emissions calculated by the bLS model are comprehensively in better agreement, but the computational demands of the modeling approach and integration into fenceline systems limit real-time applicability. While these results provide insight into model performance under controlled near-field conditions, their applicability to more complex or heterogeneous oil and gas production environments (e.g., the regions Marcellus or Unita Basins) remains limited and uncertain.

gaussian plume↗

Unsupervised classification-based hyperspectral data processing: lossy compression

The existing lossy compression algorithms play an important role in reducing the cost of storage equipment and bandwidth for hyperspectral (HS) application. However, none of the lossy compression algorithms considers the real-time classification of HS data. In this paper, we present a new lossy compression method for HS data that aims to optimally compress in both spatial and spectral domains and simultaneously maximize classification performance. For this target, Harsanyi–Farrand–Chang (HFC) and k-means++ algorithms are applied to achieve a spectral library and an index matrix for HS image. Spectral angle mapping and Euclidean distance are used to update the spectral library and the index matrix. The experiment results indicate that the proposed method has a good classification performance. The results also reveal that the proposed method works well in real-time classification and compression of HS data with a large volume and achieves a high compression ratio. It is noteworthy to mention that the superiority of our method in compression becomes more apparent as the volume of HS data grows. Consequently, the proposed method has a strong advantage in HS applications that require both compression and classification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time crystallization in fluorinated parylene probed by conductivity spectra

Dielectric relaxation spectroscopy experiments were performed at high temperature on fluorinated parylene films during the occurrence of the isothermal crystalline phase transition. For this polymer, since the difference between the glass transition temperature (T{sub g}) and the phase transition temperature (T{sub c}) is very strong (T{sub c} ≥ 4T{sub g}), segmental and dipolar relaxation usually used to probe the crystallization are not shown in the experiment frequency window (10{sup −1} to 10{sup 6} Hz) during the crystallization. The charge diffusion becomes the only electrical marker that allows probing the phase transition. During the transition phase, a continuous decrease of about two orders of magnitude is observed in the conductivity values below an offset frequency (f{sub c}) with a tendency to stabilization after 600 min. Below the offset frequency, the decrease of the normalized conductivity to the initial value as function of time is frequency independent. The same behavior is also observed for the f{sub c} values that decrease from 160 Hz to about 20 Hz. Above the offset frequency, the electronic hopping mechanism is also affected by the phase transition and the power law exponent (n) of the AC conductivity shows a variation from 0.7 to 0.95 during the first 600 min that tend to stabilize thereafter. Accordingly, three parameters (n, f{sub c}, and AC conductivity values for frequencies below f{sub c}) extracted from the AC conductivity spectra in different frequency windows seem suitable to probe the crystalline phase transition.

36 MATERIALS SCIENCE↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

In Situ Real-Time Radiographic Study of Thin Film Formation Inside Rotating Hollow Spheres

Hollow spheres with uniform coatings on the inner surface have applications in optical devices, time- or site controlled drug release, heat storage devices, and target fabrication for inertial confinement fusion experiments. The fabrication of uniform coatings, which is often critical for the application performance, requires precise understanding and control over the coating process and its parameters. Here, we report on in-situ real-time radiography experiments that provide critical spatio-temporal information about the distribution of fluids inside hollow spheres during uniaxial rotation. Image analysis and computer fluid dynamics simulations were used to explore the effect of liquid viscosity and rotational velocity on the film uniformity. The data were then used to demonstrate the fabrication of uniform sol-gel chemistry derived porous polymer films inside 2mm inner diameter diamond shells.

aerogel↗

Effect of Audio Coaching on Correlation of Abdominal Displacement With Lung Tumor Motion

Purpose: To assess the effect of audio coaching on the time-dependent behavior of the correlation between abdominal motion and lung tumor motion and the corresponding lung tumor position mismatches. Methods and Materials: Six patients who had a lung tumor with a motion range >8 mm were enrolled in the present study. Breathing-synchronized fluoroscopy was performed initially without audio coaching, followed by fluoroscopy with recorded audio coaching for multiple days. Two different measurements, anteroposterior abdominal displacement using the real-time positioning management system and superoinferior (SI) lung tumor motion by X-ray fluoroscopy, were performed simultaneously. Their sequential images were recorded using one display system. The lung tumor position was automatically detected with a template matching technique. The relationship between the abdominal and lung tumor motion was analyzed with and without audio coaching. Results: The mean SI tumor displacement was 10.4 mm without audio coaching and increased to 23.0 mm with audio coaching (p < .01). The correlation coefficients ranged from 0.89 to 0.97 with free breathing. Applying audio coaching, the correlation coefficients improved significantly (range, 0.93-0.99; p < .01), and the SI lung tumor position mismatches became larger in 75% of all sessions. Conclusion: Audio coaching served to increase the degree of correlation and make it more reproducible. In addition, the phase shifts between tumor motion and abdominal displacement were improved; however, all patients breathed more deeply, and the SI lung tumor position mismatches became slightly larger with audio coaching than without audio coaching.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Detection and measurement of radiation is used extensively for non-invasive material characterization in a range of industries. However, many practical applications are frustrated by pulse pile-up within the detector. Pulse pile-up, which occurs when multiple radiation events arrive within the temporal resolving time of the detector, degrades the fidelity of subsequent material analysis. Traditional pulse processing techniques use fast digital filters and logic circuits to detect piled-up events and discard the corrupted data, however, this leads to substantial detector dead time. Consequently, there is considerable interest in more complex signal-processing algorithms to extend the performance of pulse processors and improve material characterization techniques. We present a technology for real-time decoding of pulse pile-up events. It is a model-based signal-processing algorithm able to accurately characterize the number, time-of-arrival and energy of all events in the detector output. Even in the presence of severe multi-pulse pile-up, the composite events are decoded and the energy and time-of-arrival recovered. The technology has been evaluated using a range of detectors, sources and count rates. An exceptional improvement over traditional pulse processing techniques is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗