Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Time-resolved investigations of the non-thermal ablation process of graphite induced by femtosecond laser pulses

We report on the in-situ analysis of the ablation dynamics of the, so-called, laser induced non-thermal ablation process of graphite. A highly oriented pyrolytic graphite is excited by femtosecond laser pulses with fluences below the classic thermal ablation threshold. The ablation dynamics are investigated by axial pump-probe reflection measurements, transversal pump-probe shadowgraphy, and time-resolved transversal emission photography. The combination of the applied analysis methods allows for a continuous and detailed time-resolved observation of the non-thermal ablation dynamics from several picoseconds up to 180 ns. Formation of large, μm-sized particles takes place within the first 3.5 ns after irradiation. The following propagation of ablation products and the shock wave front are tracked by transversal shadowgraphy up to 16 ns. The comparison of ablation dynamics of different fluences by emission photography reveals thermal ablation products even for non-thermal fluences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distinctive mapping of strain and quantum size effects using depth-resolved photoluminescence in ZnO nanoneedles

In order to locate the spatially resolved influence of the strain, carrier localization, and quantum size effect (QSE) in tapered ZnO nanoneedles (NNs), the photoluminescence (PL) was measured as a function of the incident laser angle θ from 0{sup ∘} (normal to a surface) to 85{sup ∘}. With increasing θ, the excitation point is spatially restricted along the axis of the NNs and varies from the ZnO buffer/sapphire interface to the tips of the NNs. In this way, we identified a strain-induced blue-shift of 25.3 meV at the ZnO buffer/sapphire interface, which corresponds to a tensile strain of 0.319%. The influence of strain and the concomitant indications of carrier localization decreased as the excitation point moved to a higher location along the NNs with increasing θ whereas the QSE revealed an abrupt blue-shift near the tips of the NNs. Furthermore, time-resolved PL measurement as a function of the excitation angle was used to distinguish the strain effect from the QSE. We observed two spatially competing tendencies: (1) the decay times are influenced by the increase in the interfacial strain and (2) the decay times are influenced by the decrease in the diameter-dependent QSE near the tips of the tapered ZnO NNs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Time-resolved correlative optical microscopy of charge-carrier transport, recombination, and space-charge fields in CdTe heterostructures

From time- and spatially resolved optical measurements, we show that extended defects can have a large effect on the charge-carrier recombination in II-VI semiconductors. In CdTe double heterostructures grown by molecular beam epitaxy on the InSb (100)-orientation substrates, we characterized the extended defects and found that near stacking faults the space-charge field extends by 2-5 μm. Charge carriers drift (with the space-charge field strength of 730-1,360 V cm -1 ) and diffuse (with the mobility of 260 ± 30 cm 2 V -1 s -1 ) toward the extended defects, where the minority-carrier lifetime is reduced from 560 ns to 0.25 ns. Furthermore, the extended defects are nonradiative recombination sinks that affect areas significantly larger than the typical crystalline grains in II-VI solar cells. From the correlative time-resolved photoluminescence and second-harmonic generation microscopy data, we developed a band-diagram model that can be used to analyze the impact of extended defects on solar cells and other electronic devices.

14 SOLAR ENERGY↗

Exploring the structural changes on excitation of a luminescent organic bromine-substituted complex by in-house time-resolved pump-probe diffraction

The structural changes accompanying the excitation of the luminescent dibromobenzene derivative, 1,4-dibromo-2,5-bis(octyloxy)benzene, have been measured by in-house monochromatic time-resolved (TR) diffraction at 90 K. Results show an increment of the very short intermolecular Br•••Br contact distance from 3.290 Å to 3.380 Å. These calculations show the Br…Br interaction to be strongly repulsive in both the Ground and Excited states but significantly relaxed by the lengthening of the contact distance on excitation. The stability of the crystals is attributed to the many weak C-H···Br and C-H···π intermolecular interactions. Our study described is the first practical application of In-House Time-Resolved diffraction, made possible by the continuing increase in the brightness of X-ray sources and the sensitivity of our detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photodissociation of aligned CH3I and C6H3F2I molecules probed with time-resolved Coulomb explosion imaging by site-selective extreme ultraviolet ionization

We explore time-resolved Coulomb explosion induced by intense, extreme ultraviolet (XUV) femtosecond pulses from a free-electron laser as a method to image photo-induced molecular dynamics in two molecules, iodomethane and 2,6-difluoroiodobenzene. At an excitation wavelength of 267 nm, the dominant reaction pathway in both molecules is neutral dissociation via cleavage of the carbon–iodine bond. This allows investigating the influence of the molecular environment on the absorption of an intense, femtosecond XUV pulse and the subsequent Coulomb explosion process. We find that the XUV probe pulse induces local inner-shell ionization of atomic iodine in dissociating iodomethane, in contrast to non-selective ionization of all photofragments in difluoroiodobenzene. The results reveal evidence of electron transfer from methyl and phenyl moieties to a multiply charged iodine ion. In addition, indications for ultrafast charge rearrangement on the phenyl radical are found, suggesting that time-resolved Coulomb explosion imaging is sensitive to the localization of charge in extended molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photoelectron angular distributions from rotationally resolved autoionizing states of N 2

The single-photon, photoelectron-photoion coincidence spectrum of N 2 has been recorded at high (~1.5 cm -1 ) resolution in the region between the N 2 + X 2 Σ g + , v + = 0 and 1 ionization thresholds by using a double imaging spectrometer and intense vacuum-ultraviolet light from the Synchrotron SOLEIL. This approach provides the relative photoionization cross section, the photoelectron energy distribution, and the photoelectron angular distribution as a function of photon energy. The region of interest contains autoionizing valence states, vibrationally autoionizing Rydberg states converging to vibrationally excited levels of the N 2 + X 2 Σ g + ground state, and electronically autoionizing states converging to the N 2 + A 2 Π and B 2 Σ u + states. The wavelength resolution is sufficient to resolve rotational structure in the autoionizing states, but the electron energy resolution is insufficient to resolve rotational structure in the photoion spectrum. Here, a simplified approach based on multichannel quantum defect theory is used to predict the photoelectron angular distribution parameters, β, and the results are in reasonably good agreement with experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

The single-line-of-sight, time-resolved x-ray imager diagnostic on OMEGA

We present that the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium–tritium shells in inertial confinement fusion experiments in the ~4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16 channel, framing-camera–based, time-resolved Kirkpatrick–Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ~40-ps temporal resolution and better than 10 μm spatial resolution. Finally, shots with neutron yields of up to 1 × 10 14 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementing time resolved electron temperature capability at the NIF using a streak camera

A new capability on NIF has been implemented to measure the temperature of x-ray emitting sources. Although it is designed primarily for Inertial Confinement Fusion (ICF), it can be used for any hot emitting source that is well modeled. The electron temperature (T e ) of the hot spot within the core of imploded inertial confinement fusion capsules is an effective indicator of implosion performance. Currently, there are spatially and temporally integrated T e inferences using image plates. A temporally resolved measurement of Te will help elucidate the mechanisms for hot spot heating and cooling such as conduction to fuel, alpha-heating, mix and radiative losses. To determine the temporally resolved T e of hot spots, specific filters are added to an existing x-ray streak camera “Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER)” to probe the emission spectrum during the x-ray burn history of implosions on the National Ignition Facility (NIF). One of the difficulties in inferring the hot spot temperature is the attenuation of the emission due to opacity from the shell and fuel. Therefore, a series of increasingly thick titanium filters were implemented to isolate the emission in specific energy regions that are sensitive to temperatures above 3keV while not significantly influenced by the shell/fuel attenuation. Additionally, a relatively thin zinc filter was used to measure the contribution of colder emission sources. Since the signal levels of the emission through the thicker filters are relatively poor, a dual slit (aperture) was designed to increase detected signal at the higher end of the spectrum. Herein, the design of the filters and slit are described, an overview of the solving technique is provided, and initial electron temperature results are reported.

47 OTHER INSTRUMENTATION↗

Measuring femtometer lattice displacements driven by free carrier diffusion in a polycrystalline semiconductor using time-resolved x-ray scattering

We show that time-resolved x-ray scattering can be applied to polycrystalline materials for the measurement of carrier diffusion. A polycrystalline indium antimonide sample is prepared by high-intensity ultrafast laser surface melting and re-solidification under vacuum to create randomly oriented grains with an average size of 13 nm. Two static diffraction rings are simultaneously observed on a gated pixel array detector. Their centroids move following lower-intensity laser excitation, and utilizing an in-situ angular calibration, the transient lattice spacing is determined with femtometer accuracy, thereby allowing the measurement of charge carrier dynamics. Compared to bulk calculations, we find that carrier diffusion slows by more than one order of magnitude. This result provides evidence for the formation of potential energy barriers at the grain boundaries and demonstrates the capability of time-resolved x-ray scattering to probe nanoscale charge transport in materials other than near-perfect crystals.

36 MATERIALS SCIENCE↗

A setup for extreme-ultraviolet ultrafast angle-resolved photoelectron spectroscopy at 50-kHz repetition rate

Time- and angle-resolved photoelectron spectroscopy (trARPES) is a powerful method to track the ultrafast dynamics of quasiparticles and electronic bands in energy and momentum space. We present a setup for trARPES with 22.3 eV extreme-ultraviolet (XUV) femtosecond pulses at 50-kHz repetition rate, which enables fast data acquisition and access to dynamics across momentum space with high sensitivity. The design and operation of the XUV beamline, pump-probe setup, and ultra-high vacuum endstation are described in detail. By characterizing the effect of space-charge broadening, we determine an ultimate source-limited energy resolution of 60 meV, with typically 80-100 meV obtained at 1-2 × 10 10 photons/s probe flux on the sample. The instrument capabilities are demonstrated via both equilibrium and time-resolved ARPES studies of transition-metal dichalcogenides. The 50-kHz repetition rate enables sensitive measurements of quasiparticles at low excitation fluences in semiconducting MoSe 2 , with an instrumental time resolution of 65 fs. Moreover, photo-induced phase transitions can be driven with the available pump fluence, as shown by charge density wave melting in 1T-TiSe 2 . The high repetition-rate setup thus provides a versatile platform for sensitive XUV trARPES, from quenching of electronic phases down to the perturbative limit.

47 OTHER INSTRUMENTATION↗

Time-resolved x-ray crystallography capture of a slow reaction tetrahydrofolate intermediate

Time-resolved crystallography is a powerful technique to elucidate molecular mechanisms at both spatial (angstroms) and temporal (picoseconds to seconds) resolutions. We recently discovered an unusually slow reaction at room temperature that occurs on the order of days: the in crystalline reverse oxidative decay of the chemically labile (6S)-5,6,7,8-tetrahydrofolate in complex with its producing enzyme Escherichia coli dihydrofolate reductase. Here, we report the critical analysis of a representative dataset at an intermediate reaction time point. A quinonoid-like intermediate state lying between tetrahydrofolate and dihydrofolate features a near coplanar geometry of the bicyclic pterin moiety, and a tetrahedral sp 3 C6 geometry is proposed based on the apparent mFo-DFc omit electron densities of the ligand. The presence of this intermediate is strongly supported by Bayesian difference refinement. Isomorphous Fo-Fo difference map and multi-state refinement analyses suggest the presence of end-state ligand populations as well, although the putative intermediate state is likely the most populated. A similar quinonoid intermediate previously proposed to transiently exist during the oxidation of tetrahydrofolate was confirmed by polarography and UV-vis spectroscopy to be relatively stable in the oxidation of its close analog tetrahydropterin. We postulate that the constraints on the ligand imposed by the interactions with the protein environment might be the origin of the slow reaction observed by time-resolved crystallography.

59 BASIC BIOLOGICAL SCIENCES↗

High resolution time- and angle-resolved photoemission spectroscopy with 11 eV laser pulses

Performing time- and angle-resolved photoemission (tr-ARPES) spectroscopy at high momenta necessitates extreme ultraviolet laser pulses, which are typically produced via high harmonic generation (HHG). Despite current advances, HHG-based setups still require large pulse energies (from hundreds of μ J to mJ) and their energy resolution is limited to tens of meV. Here, we present a novel 11 eV tr-ARPES setup that generates a flux of 5 × 10 10 photons/s and achieves an unprecedented energy resolution of 16 meV. It can be operated at high repetition rates (up to 250 kHz) while using input pulse energies down to 3 µ J. We demonstrate these unique capabilities by simultaneously capturing the energy and momentum resolved dynamics in two well-separated momentum space regions of a charge density wave material ErTe 3 . This novel setup provides the opportunity to study the non-equilibrium band structure of solids with exceptional energy and time resolutions at high repetition rates.

47 OTHER INSTRUMENTATION↗

Watching a signaling protein function: What has been learned over four decades of time-resolved studies of photoactive yellow protein

Photoactive yellow protein (PYP) is a signaling protein whose internal p-coumaric acid chromophore undergoes reversible, light-induced trans-to-cis isomerization, which triggers a sequence of structural changes that ultimately lead to a signaling state. Since its discovery nearly 40 years ago, PYP has attracted much interest and has become one of the most extensively studied proteins found in nature. The method of time-resolved crystallography, pioneered by Keith Moffat, has successfully characterized intermediates in the PYP photocycle at near atomic resolution over 12 decades of time down to the sub-picosecond time scale, allowing one to stitch together a movie and literally watch a protein as it functions. But how close to reality is this movie? To address this question, results from numerous complementary time-resolved techniques including x-ray crystallography, x-ray scattering, and spectroscopy are discussed. Emerging from spectroscopic studies is a general consensus that three time constants are required to model the excited state relaxation, with a highly strained ground-state cis intermediate formed in less than 2.4 ps. Persistent strain drives the sequence of structural transitions that ultimately produce the signaling state. Crystal packing forces produce a restoring force that slows somewhat the rates of interconversion between the intermediates. Moreover, the solvent composition surrounding PYP can influence the number and structures of intermediates as well as the rates at which they interconvert. When chloride is present, the PYP photocycle in a crystal closely tracks that in solution, which suggests the epic movie of the PYP photocycle is indeed based in reality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical analysis of non-Maxwellian electron distribution functions measured with angularly resolved Thomson scattering

Angularly resolved Thomson scattering is a novel extension of Thomson scattering, enabling the measurement of the electron velocity distribution function over many orders of magnitude. Here, details of the theoretical basis of the technique and the instrument designed for this measurement are described. Angularly resolved Thomson-scattering data from several experiments are shown with descriptions of the corresponding distribution functions. A reduced model describing the distribution function is given and used to perform a Monte Carlo analysis of the uncertainty in the measurements. The electron density and temperature were determined to a precision of 12% and 21%, respectively, on average, while all other parameters defining the distribution function were generally determined to better than 20%. It was found that these uncertainties were primarily due to limited signal to noise and instrumental effects. Furthermore, measurements with this level of precision were sufficient to distinguish between Maxwellian and non-Maxwellian distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved photoelectron imaging of complex resonances in molecular nitrogen

We have used the FERMI free-electron laser to perform time-resolved photoelectron imaging experiments on a complex group of resonances near 15.38 eV in the absorption spectrum of molecular nitrogen, N-2, under jet-cooled conditions. The new data complement and extend the earlier work of Fushitani et al. [Opt. Express 27, 19702-19711 (2019)], who recorded time-resolved photoelectron spectra for this same group of resonances. Time-dependent oscillations are observed in both the photoelectron yields and the photoelectron angular distributions, providing insight into the interactions among the resonant intermediate states. In addition, for most states, we observe an exponential decay of the photoelectron yield that depends on the ionic final state. This observation can be rationalized by the different lifetimes for the intermediate states contributing to a particular ionization channel. Finally, although there are nine resonances within the group, we show that by detecting individual photoelectron final states and their angular dependence, we can identify and differentiate quantum pathways within this complex system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗