Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resource conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

2021–2022 Can Do Colorado E-Bike Full-Scale Pilot Program Study

In 2021–2022, the Colorado Energy Office conducted a full-scale pilot program study on e-bike usage as part of the Can Do Colorado initiative, providing e-bikes to low-income participants across the state. A [2020 mini pilot program study](https://www.nlr.gov/transportation/secure-transportation-data/tsdc-2020-can-do-colorado-e-bike-pilot-program.html) informed the full-scale study. Both studies used pedal-assist e-bikes, which feature an electric motor and battery to help power the bike. The motor amplifies the power behind each pedal stroke, augmenting the energy you put into the bike. #### Data Collection Agency The Colorado Energy Office conducted the study in partnership with local organizations in Adams and Broomfield counties (Smart Commute Metro North), Boulder (Community Cycles), Durango (Four Corners Office for Resource Efficiency), Fort Collins (City of Fort Collins), Pueblo (Pueblo County), and Vail (Town of Vail). #### Survey Methodology Program participants received an e-bike and accessories at no cost and manually submitted travel data and feedback via the CanBikeCO smartphone app. Developed in partnership with NLR, the app used a customized version of the open-source [NLR OpenPATH platform](https://www.nlr.gov/transportation/openpath.html). #### Survey Records and Data Survey records include 170 participants. The six datasets contain up to 18 months of partially automated travel diaries, combining sensed and surveyed travel behavior data—patterns of multimodal, end-to-end, individual human mobility—as well as demographic information from participants. The number of e-bike trips and e-bike miles traveled per location are 1,560 and 4,179 for Adams and Broomfield counties; 8,481 and 27,000 for Boulder; 2,815 and 6,307 for Durango; 3,483 and 7,080 for Fort Collins; 4,022 and 14,887 for Pueblo, and 1,206 and 3,3361 for Vail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tariff Setting in the District Heating Sector: Recommendations Based on International Experience

Ukraine’s district heating (DH) system is an essential resource for the country and has the potential to provide efficient, local, and renewable energy to a large share of the population. However, inefficient regulation and management have caused the sector to experience a vicious cycle of financial, operational, and technological problems. Overcoming these challenges and building a sustainable DH system requires comprehensive reforms, which could attract significant investment, improve the quality of services, and increase the efficiency of DH. One of the key elements of a comprehensive reform program should be a comprehensive reform of the tariff system. The purpose of this report is to provide analysis of European models for tariff regulation and recommendations for reforms to Ukraine’s DH tariff system. The report presents several case studies from European countries, followed by analysis of the current tariff system in Ukraine and barriers to effective regulation. Based on these findings, the report proposes actions Ukraine could take to improve the tariff regulatory system and promote a sustainable DH sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Abstract for CRADA between Capture6 CORP and NETL

The National Energy Technology Laboratory (NETL) and Capture6 CORP (Participant) will collaborate to refine Capture6’s transformative air contactor design for optimal direct air capture (DAC) under an awarded project from the Department of Energy’s Direct Air Capture Pre-Commercialization Technology Prize. Current cooling tower designs require exponentially more resources as the concentration of CO 2 in the gas phase decreases, resulting in a low conversion rate of carbonates, a large physical footprint, and high evaporation of water, which consequently limits the energy and water benefits that a DAC process can create. Capture6’s innovative tower design AURA (Absorption Unit Reactor for Ambient air) seeks to improve the mass transfer characteristics of legacy cooling towers and reduces total energy demand by: (1) introducing laminar and turbulent flow to increase mass transfer, (2) generating a solvent gradient to improve CO 2 absorption, (3) leveraging venturi and packed towers to increase the surface for the mass-transfer process, (4) adding charged/cool plates to reduce overall water loss in the system, and (5) utilizing surfactant additives to increase mass transfer. The collaboration will facilitate the deployment of technologies that reduce the total energy required and carbon footprint of solvent-based carbon dioxide removal (CDR) technologies. The anticipated results support NETL’s goal of fostering rapid development and commercialization pathways for technologies that remove CO 2 from the atmosphere.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Waste to worth: a circular solution through lignin engineering

The inefficient management of industrial waste threatens environmental sustainability, requiring scalable resource recovery solutions. To address these challenges, we propose a novel and sustainable in-situ one-step strategy for the simultaneous recovery and functionalization of lignin from industrial black liquor, using a sustainable organic acid system assisted by choline chloride. The functionalized lignin adsorbent material (FLAM) exhibited superior adsorption performance, effectively treating animal feedlot wastewater to recover ammonia. The ammonia enriched FLAM was subsequently repurposed as a slow-release fertilizer, enhancing plant growth and demonstrating a closed-loop pathway for waste valorization and nutrient recycling. Methylene blue was used as a model cationic compound to simulate the adsorption behavior and interactions. FLAM achieved a high adsorption capacity of 725.98 mg/g across a broad pH range, significantly outperforming commercial kraft lignin. This sustainable approach advances circular economy principles by integrating remediation and resource recovery, offering a scalable, eco-friendly solution for environmental applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Discrete fracture network model benchmarks developed and applied in a DECOVALEX-2023 repository performance assessment study

This study presents newly developed benchmarks for modeling flow and transport within discrete fracture networks (DFNs) and useful methods for analyzing the results. The new benchmarks are designed to test modeling approaches for use in probabilistic performance assessment models of deep geologic repositories in fractured rock. The benchmarks simulate flow and transport through a 1 km 3 block of fractured rock. The first simulates migration of a short pulse of tracer through a simple network of four intersecting fractures. The second adds 1089 stochastically generated fractures. The third changes the pulse to a continuous point source. Evaluation of model performance relies on moment analysis and comparison of the results of different models. The expected nondimensional first moment of the conservative tracer for each benchmark is 1. The benchmarks were simulated by teams from Canada, Czechia, Germany, Korea, Sweden, Taiwan, and the United States as part of a DECOVALEX-2023 study (decovalex.org). The teams used various approaches, including explicit DFN modeling, DFN upscaling to an equivalent continuous porous medium (ECPM), and a combination of both methods. Transport mechanisms are modeled using either the advection-dispersion equation or particle tracking. Results demonstrate strong agreement among the models in breakthrough behavior up to the 75th percentile. Significant deviations in first moments and well-clustered outputs led to the identification of inaccuracies in several models. Such findings exemplify the benefit of exercising these benchmarks and using the presented methods to test DFN flow and transport models.

Benchmark↗

Ten questions concerning energy flexibility in buildings

Demand side energy flexibility is increasingly being viewed as an essential enabler for the swift transition to a low-carbon energy system that displaces conventional fossil fuels with renewable energy sources while maintaining, if not improving, the operation of the energy system. Building energy flexibility may address several challenges facing energy systems and electricity consumers as society transitions to a low-carbon energy system characterized by distributed and intermittent energy resources. For example, by changing the timing and amount of building energy consumption through advanced building technologies, electricity demand and supply balance can be improved to enable greater integration of variable renewable energy. Although the benefits of utilizing energy flexibility from the built environment are generally recognized, solutions that reflect diversity in building stocks, customer behavior, and market rules and regulations need to be developed for successful implementation. In this paper, we pose and answer ten questions covering technological, social, commercial, and regulatory aspects to enable the utilization of energy flexibility of buildings in practice. In particular, we provide a critical overview of techniques and methods for quantifying and harnessing energy flexibility. We discuss the concepts of resilience and multi-carrier energy systems and their relation to energy flexibility. We argue the importance of balancing stakeholder engagement and technology deployment. Finally, we highlight the crucial roles of standardization, regulation, and policy in advancing the deployment of energy flexible buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Depletion to Restoration: Lessons From Long‐Term Monitoring of Carbon Gains and Losses in Cropping Systems

As global atmospheric CO 2 rapidly approaches a key tipping point, there is an urgent need to implement strategies to reverse this pattern. A generally accepted understanding of carbon (C) in agricultural fields includes: (H1) substantial C loss occurs when natural vegetation is converted to crops, (H2) soils typically reach a steady-state C concentration under contemporary practices, and (H3) improved management or crop selection can enhance soil C stocks over time. Significant variability exists, but studies consistently show large C losses from agricultural ecosystems, supporting H1. Although steady-state C levels (H2) are commonly assumed, measuring C gains or losses in mature agroecosystems is challenging. Efforts to increase soil C storage (H3) have limited data due to the diversity of potential practices, compounded by substantial variability in soil C measurements. Here, long-term (7–17 year) ecosystem C flux data from diverse cropping systems revealed that conventionally tilled annual row crops (maize and soybean) act as significant long-term atmospheric C sources, challenging H2. Furthermore, conservation tillage practices reduced C losses compared with conventional tillage but showed minimal evidence for long-term ecosystem C storage, even after 20+ years. This indicates that no-till practices reduce C losses but imply that no soil C is added, challenging H3. By contrast, perennial Miscanthus × giganteus, Panicum virgatum, and restored tallgrass prairie systems store C at the ecosystem scale more effectively than minimally tilled annual row crops. Analysis over multiple years demonstrates significant ecosystem C storage with perennial crops, varying by species, starting in the first year of transition. These findings, although focused on one region, suggest that the assumptions of steady-state C levels and increased storage from conservation practices do not universally apply and that significant changes to agroecosystems are required to increase C storage.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of genetic diversity, agronomic traits, and anthracnose resistance in the NPGS Sudan Sorghum Core collection

The United States Department of Agriculture (USDA) National Plant Germplasm System (NPGS) sorghum core collection contains 3011 accessions randomly selected from 77 countries. Genomic and phenotypic characterization of this core collection is necessary to encourage and facilitate its utilization in breeding programs and to improve conservation efforts. In this study, we examined the genome sequences of 318 accessions belonging to the NPGS Sudan sorghum core set, and characterized their agronomic traits and anthracnose resistance response. We identified 183,144 single nucleotide polymorphisms (SNPs) located within or in proximity of 25,124 annotated genes using the genotyping-by-sequencing (GBS) approach. The core collection was genetically highly diverse, with an average pairwise genetic distance of 0.76 among accessions. Population structure and cluster analysis revealed five ancestral populations within the Sudan core set, with moderate to high level of genetic differentiation. In total, 171 accessions (54%) were assigned to one of these populations, which covered 96% of the total genomic variation. Genome scan based on Tajima’s D values revealed two populations under balancing selection. Phenotypic analysis showed differences in agronomic traits among the populations, suggesting that these populations belong to different ecogeographical regions. A total of 55 accessions were resistant to anthracnose; these accessions could represent multiple resistance sources. Genome-wide association study based on fixed and random model Circulating Probability (farmCPU) identified genomic regions associated with plant height, flowering time, panicle length and diameter, and anthracnose resistance response. Integrated analysis of the Sudan core set and sorghum association panel indicated that a large portion of the genetic variation in the Sudan core set might be present in breeding programs but remains unexploited within some clusters of accessions. The NPGS Sudan core collection comprises genetically and phenotypically diverse germplasm with multiple anthracnose resistance sources. Population genomic analysis could be used to improve screening efforts and identify the most valuable germplasm for breeding programs. The new GBS data set generated in this study represents a novel genomic resource for plant breeders interested in mining the genetic diversity of the NPGS sorghum collection.

59 BASIC BIOLOGICAL SCIENCES↗

Basic Research Needs for Transformative Manufacturing (Brochure)

Manufacturing is central to the nation’s prosperity and security. Manufacturing currently represents about 12% of the gross domestic product, provides nearly 13 million jobs, and accounts for about 25% of energy use. The nation’s economy relies heavily on wide-ranging manufacturing sectors - all of which share common challenges including data issues, lack of physics and chemistry-based models across scales, and resource constraints in a global environment. Furthermore, there are many hurdles that must be overcome to move basic science innovations to market. Addressing broad-ranging challenges demands a basic-science strategy that underpins applied research activities. This strategy would accelerate innovation and transform manufacturing. A Basic Research Needs workshop for Transformative Manufacturing was held in March 2020. The focus of the workshop was to identify the basic science research priorities that could accelerate innovation to transform manufacturing in the future. This was the first workshop of its kind to examine how basic energy science can drive manufacturing forward and innovate new ways to manufacture goods. Five Priority Research Directions were identified that address these science challenges: (1) innovative synthetic approaches to enable scalable assembly of matter, (2) computational methods and theoretical models to transform how manufacturing processes are controlled, (3) new characterization tools that can handle the necessary complexity, scales, and processing speeds to meet manufacturing needs, (4) new science to address opportunities relevant to sustainable and energy-efficient manufacturing, and (5) foundational approaches to co-design of materials, process, and products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

JUMP Into STEM 2018-2025: Challenge Highlights and Implementation Guidance

Building sciences and technology directly impact human health, productivity, and resource consumption (e.g., energy and critical minerals). Addressing emerging challenges in this field requires skilled building science professionals. JUMP into STEM sought to inspire the next generation of building scientists through a real-world competition that introduced participants to the field and connected them with national laboratory and industry professionals. This report highlights select challenges from past competitions which are tailored for academic and industry professionals who aim to develop or recruit multidisciplinary talent. It also includes additional guidance to support the effective replication of these challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Codes and Grid-Interactive Efficient Buildings: How building energy codes can enable a more dynamic and energy-efficient built environment

This report considers the role of national model codes to promote grid-interactive efficient buildings (GEBs) as part of the modernization of the U.S. electricity grid. It introduces GEBs, describes their ability to support a clean, resilient grid, and considers challenges and approaches for incorporating GEB measures into national model energy codes and standards. Desirable traits of GEB include being low energy, low peaking, and responsive to grid needs, and minimizing the curtailment of renewable energy resources. In addition, the future grid incurs a time and locational value on these types of building services. Accounting for these considerations in future code development requires a continuation and expansion of code-minimum energy efficiency requirements and inclusion of demand responsive and load flexibility measures while ensuring annual use and cost reductions. Also, efforts to include GEB measures in codes will be limited until they are fully developed into an American National Standards Institute (ANSI)-approved standard. Then it would be straightforward to address GEB measures through points or packages and/or scoring requirements. Otherwise, the building code would have to describe each specific grid responsive strategy. This document reviews topics pertinent to considering codes in this context. Specifically, the study presents the status and direction of current building energy codes, the future smart grid, low-energy buildings, and grid-integrated buildings. The report concludes with recommendations for future code development activities to support low-energy, grid-interactive buildings in order to provide added value to building owners, the grid, and society.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Planning for a Resilient Home Electricity Supply System

Resilience of power systems is already a key issue that is getting frequent attention all over the world. It is useful to analyze resilience issues not only for bulk supply, but at all levels including at a customer level. This is because distributed energy resources can play a prominent role in enhancing resilience. Although the literature on planning models, tools and data for bulk supply and distribution systems have expanded in recent years, customer-centric planning, e.g., for an individual household, is yet to receive adequate attention. Although solar PV and battery storage at a household level have been analyzed, how these resources can be optimally combined, together with grid supply, from a resilience perspective is the focus of this study. The study demonstrates how a conceptual framework can be developed to show the trade-off between system costs and resilience including its dimensions such as duration, depth and frequency of service outages. A planning model is developed that incorporates multiple facets of resilience and individual customer preferences. The model considers power system resilience explicitly as a constraint. The model is implemented for a household level case study in Miami, Florida. The results show there are complex trade-offs among different dimensions of resilience. The study demonstrates how combined resilience metrics can be formulated and evaluated using the proposed least-cost planning model at a household level to optimize grid supply together with solar, battery storage and diesel generators. The model allows a planner to directly embed a resilience standard to drive the optimal supply mix. These concepts and the modeling construct can also be applied at other levels of planning, including community level and bulk supply system planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗