Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Vibro-acoustic modulation and data fusion for localizing alkali–silica reaction–induced damage in concrete

This article investigates the application of vibro-acoustic modulation testing for diagnosing damage in concrete structures. The vibro-acoustic modulation technique employs two excitation frequencies on a structure. The interaction of these excitations in the measured response indicates damage through the presence of sidebands in the frequency spectra. Past studies using this technique have mostly focused on metals and composites (thin plates or laminates). Our research focuses on concrete, which is a highly heterogeneous material susceptible to a variety of chemical, physical, and mechanical damage processes. In particular, this article investigates diagnosing cracking in concrete from an expansive gel produced by an alkali–silica reaction in the presence of moisture. Past studies have been limited to damage detection using vibro-acoustic modulation testing, whereas this article extends the technique to damage localization. A cement slab with pockets of reactive aggregate is used to investigate the diagnosis technique. The effects of different testing parameters, such as locations, magnitudes, and frequencies of the two excitations, are analyzed and incorporated in the damage localization methodology. A Bayesian probabilistic methodology is developed to fuse the information from multiple test configurations in order to construct damage probability maps for the test specimen. The results of vibro-acoustic modulation–based damage localization are validated by petrographic study of cores taken from the slab.

Karve, Pranav↗

A new look at decomposition of turbulence forcing field and the structural response

Measured cross-spectrum of a turbulence field usually shows some decay in the statistical correlation in addition to convection at a characteristic velocity. It is shown that a decaying turbulence can be decomposed into frozen-pattern components thus permitting a simpler way to calculate the structural response. This procedure also provides a relationship whereby the measured input spectra can be incorporated. The theory is applied to an infinite beam which is backed on one side by a fluid filled cavity and is exposed on the other side by the turbulence excitation. The effect of the free stream velocity is also taken into consideration.

Lin, Y. K.↗

Rotor transient analysis

Undamped modes approximate dynamic behavior of rotors and bearings. Application of modal analysis to uncouple equations of motion simplifies stability, steady-state unbalance response, and transient response analysis of system; nonlinear stability is predicted from calculated frequency spectra. Analysis provides designers with complete information without involving large-scale computational costs. Programs are written in FORTRAN IV for use on CDC 6600 computer.

Allaire, P. E.↗

The use of a numerical filter to correct airborne temperature measurements for the effects of sensor lag

A numerical filter for transforming measured temperature signals into a close approximation of the actual temperature signal is described. The filter is derived by minimizing the mean-square error of the system, and assuming a knowledge of the characteristics of the sensing element and its housing. The equation representing the frequency-response function of the numerical filter is given. Input and output spectra for a filter applied to a case with negligible noise and a noise level of 1.5 percent of the total power in the input spectrum are analyzed, and the numerical weights for these two cases are calculated. Phase angle and gain for the entire system are examined. It is noted that the filter can enhance spectral components as high as 8 Hz with little phase and gain degradation over the bandwidth.

Ritter, John A.↗

The composition of Martian aeolian sands: Thermal emissivity from Viking IRTM observations

Aeolian sands provide excellent surfaces for the remote determination of the mineralogic composition of Martian materials, because such deposits consist of relatively well-sorted, uniform particle sizes and might consist of chemically unaltered, primary mineral grains derived from bedrock. Dark features on the floors of Martian craters are controlled by aeolian processes and many consist largely of unconsolidated, windblown sand. Measurement of the thermal emissivity of geologic materials provides a way to identify mid-infrared absorption bands, the strength and positions of which vary with mineral structure and composition. The Viking Infrared Thermal Mapper (IRTM) had four surface-sensing mid-IR bands, three of which, the 7, 9, and 11 micron channels, correspond to absorption features characteristic of carbonates, sialic, and mafic minerals, respectively. In this study, the highest quality IRTM data were constrained so as to avoid the effects of atmospheric dust, clouds, surface frosts, and particle size variations (the latter using data obtained between 7 and 9 H, and they were selected for dark intracrater features such that only data taken directly from the dark feature were used, so as to avoid thermal contributions from adjacent but unrelated materials. Three-point emissivity spectra of Martian dart intracrater features were compared with laboratory emission spectra of minerals and terrestrial aeolian sands convolved using the IRTM response function to the four IRTM spectral channels.

Edgett, Kenneth S.↗

DSS-14 subreflector actuator dynamics during the Landers earthquake

The 28 Jun. 1992 Landers earthquake ground motion records at the Echo site (DSS-12 antenna) were adjusted to provide a better match with spectra from the measured Mars site (DSS-14 antenna) instrument tower response. A finite-element model of the antenna structural system was analyzed for response to this ground motion. Dynamic forces and displacements were computed in the locality of components that had failed during the earthquake. Calculated forces in the range of 30,000 to 35,000 lb on failed Y-axis actuator U-joints were consistent with laboratory load tests. The load capacity of these joints was found to be below the range of 34,000 to 42,000 lb. Dynamic amplification factors of from 6 to 16 were computed for the quadripod apex accelerations with respect to the ground accelerations. The largest factor--25--was found at the outboard end of the X-actuator.

Levy, R.↗

Spaceflight alters autonomic regulation of arterial pressure in humans

Spaceflight is associated with decreased orthostatic tolerance after landing. Short-duration spaceflight (4 - 5 days) impairs one neutral mechanism: the carotid baroreceptor-cardiac reflex. To understand the effects of longer-duration spaceflight on baroreflex function, we measured R-R interval power spectra, antecubital vein plasma catecholamine levels, carotid baroreceptor-cardiac reflex responses, responses to Valsalva maneuvers, and orthostatic tolerance in 16 astronauts before and after shuttle missions lasting 8 - 14 days. We found the following changes between preflight and landing day: (1) orthostatic tolerance decreased; (2) R-R interval spectral power in the 0.05- to 0.15-Hz band increased; (3) plasma norepinephrine and epinephrine levels increased; (4) the slope, range, and operational point of the carotid baroreceptor cardiac reflex response decreased; and (5) blood pressure and heart rate responses to Valsalva maneuvers were altered. Autonomic changes persisted for several days after landing. These results provide further evidence of functionally relevent reductions in parasympathetic and increases in sympathetic influences on arterial pressure control after spaceflight.

Fritsch-Yelle, Janice M.↗

Measured Polarized Spectral Responsivity of JPSS J1 VIIRS Using the NIST T-SIRCUS

Recent pre-launch measurements performed on the Joint Polar Satellite System (JPSS) J1 Visible Infrared Imaging Radiometer Suite (VIIRS) using the National Institute of Standards and Technology (NIST) Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources (T-SIRCUS) monochromatic source have provided wavelength dependent polarization sensitivity for select spectral bands and viewing conditions. Measurements were made at a number of input linear polarization states (twelve in total) and initially at thirteen wavelengths across the bandpass (later expanded to seventeen for some cases). Using the source radiance information collected by an external monitor, a spectral responsivity function was constructed for each input linear polarization state. Additionally, an unpolarized spectral responsivity function was derived from these polarized measurements. An investigation of how the centroid, bandwidth, and detector responsivity vary with polarization state was weighted by two model input spectra to simulate both ground measurements as well as expected on-orbit conditions. These measurements will enhance our understanding of VIIRS polarization sensitivity, improve the design for future flight models, and provide valuable data to enhance product quality in the post-launch phase.

JPSS↗

Detector Response Function and Directional Gamma-Ray Source Calculations for Polaris

A Directional Unfolded Source Term (DUST) method was developed to compute directionally resolved gamma-ray source terms based on back-projection spectra synthesized by Compton Cameras. Spectral features in the unprocessed spectra are indistinct primarily because the rotational angles for the conical projections cannot be determined, so probability distributions are constructed from overlapping cones. The DUST method uses an angular response function to compute a covariance matrix, which is used to process count rates in back-projection spectra by linear regression to partition the gamma-rays among several spatial regions. This method was applied to analyze data collected by the Polaris detector during an evaluation that was conducted at Oak Ridge National Laboratory (ORNL). The evaluation includes measurements of calibration sources with angular separations ranging from 1° to more than 50°. Measurements were also performed for cylindrical depleted uranium castings and a 137 Cs source inside a large polyethylene sphere. The DUST algorithm was able to differentiate gamma-rays emitted by 137 Cs and 60 Co when the sources were separated by less than 2°, but separation greater than 10° was required to isolate the 133 Ba emission from gamma-rays emitted by the other sources. The computed source terms were consistent with emission profiles from the calibration sources and from models of the spatially-extended sources. Methods for viewing radiation profiles were also evaluated because user input is required to select spatial regions of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High accuracy absorbance spectrophotometers

Spectrophotometers and spectroscopy processes are described that can provide for in-line calibration at every spectral acquisition as well as for continuous response correction during sample processing. The spectrophotometers include multiple polychromatic light sources that include characteristic emission spectra for use as an internal wavelength drift calibration system that is independent of environmental factors. Correction functions provided by the internal calibration process can be applied continuously and across an entire sample spectrum. The intensity response of each spectrometer in a spectrophotometer can also be monitored and continuously corrected for stray light, dark current, readout noise, etc.

O'Rourke, Patrick E.↗

Reproducibility and calibration of MMC-based high-resolution gamma detectors

Here, we describe a prototype γ-ray detector based on a metallic magnetic calorimeter with an energy resolution of 46 eV at 60 keV and a reproducible response function that follows a simple second-order polynomial. The simple detector calibration allows adding high-resolution spectra from different pixels and different cool-downs without loss in energy resolution to determine γ-ray centroids with high accuracy. As an example of an application in nuclear safeguards enabled by such a γ-ray detector, we discuss the non-destructive assay of 242 Pu in a mixed-isotope Pu sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An assessment of the impact of system spectral response parameters on spectral shape and algal bloom detection for the GeoXO ocean color instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A large dataset in-situ spectra, from a variety of locations and water cases collected with an above water spectrometer, was used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX.

Monica Cook↗

Calibration of a High Resolution Soft X-ray Spectrometer

A high resolution grating spectrometer (HRGS) with 2400 line/mm variable line spacing grating for the 10-50 {angstrom} wavelength range has been designed for laser-produced plasma experiments at the Lawrence Livermore National Laboratory (LLNL). The spectrometer has a large radius of curvature, R=44.3 m, is operated at a 2{sup o} grazing angle and can record high signal-to-noise spectra when used with a low-noise, cooled, charge-coupled device detector. The instrument can be operated with a 10-25 {micro}m wide slit to achieve the best spectral resolving power on laser plasma sources, approaching 2000, or in slitless mode with a small symmetrical emission source. Results will be presented for the spectral response of the spectrometer cross-calibrated at the LLNL Electron Beam Ion Trap facility using the broadband x-ray energy EBIT Calorimeter Spectrometer (ECS).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Changes in polarization dictate necessary approximations for modeling electronic deexcitation intensity: Application to x-ray emission

Accurate simulation of electronic excitations and deexcitations are critical for complementing complex spectroscopic experiments and can provide validation to theoretical approaches. Here, using a generalized framework, we contrast the accuracy and validity of orbital-constrained and linear-response approaches that build upon Kohn-Sham density functional theory (DFT) to simulate emission spectra of electronic origin and propose an efficient approximation, named many-body x-ray emission spectroscopy or MBXES, for simulating such processes. We show analytically as well as with computed examples that for electronic (de)excitation leading to an appreciable change in polarization (i.e., density rearrangement), the adiabatic approximation in a response-based formalism will be inadequate for the calculation of oscillator strength. Thus, such a change (e.g., in the net electrostatic dipole moment of a finite system) can be used as a metric for evaluating the applicability of the adiabatic response-based approach and can be particularly valuable in x-ray emission spectroscopy. On the other hand, MBXES, the flexible method introduced in this paper, can compute oscillator strengths accurately at a much lower computational expense on the basis of two DFT-based self-consistent field calculations. Using illustrative examples of emission spectra, the efficacy of the MBXES method is demonstrated by comparison with its parent theory, orbital-optimized DFT, and with experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimizing detector geometry for trace element mapping by X-ray fluorescence

Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral signature of oxidized pyroxenes - Implications to remote sensing of terrestrial planets

The effect of the structural Fe(3+) or disseminated ferric oxides in oxidized ferromagnesian silicates on the reflectance spectral profiles of the remnant Fe(2+) ions in oxidized silicates was investigated. Results of spectral measurements in the visible NIR region, performed on several well-characterized pyroxenes representative of different structural types and compositions, were correlated with data obtained from the Mossbauer spectra of the oxidation products. The measurements made it possible to determine the relative proportions of Fe(2+) and Fe(3+) ions present in the oxidized pyroxenes and provided information on the amorphous ferric oxide phases present in the oxidation products. The results also suggest a mechanism for producing the nanophase hematite popularly considered to be responsible for the features observed around 0.62 and 0.87 micron in the remotely sensed spectra of Mars.

Straub, D'arcy W.↗

Infrared characterized spacecraft contaminants and related compounds

The limits of the infrared region of the electromagnetic spectrum are discussed, together with an explanation of some of the shortcomings of obtaining data in this range. Similarities and differences in the interest taken by the chemist/spectroscopist and the space/spectroscopist in the IR spectrum are discussed. The chemist uses IR spectra to identify materials and contaminants associated with spacecraft fabrication and testing. The space scientist, using IR spectrometry, can determine atmospheric conditions around planets, stars, and galaxies. He could also determine the temperature profile of the Earth's atmosphere at different altitudes, or even the temperature profile of the Sun. The importance of detecting contamination of spacecraft and the possible results of not taking corrective action are explored. All space experiments contain some contaminants, to a lesser or greater degree; the responsible personnel involved must determine the level of toleration. A collection of IR spectra of known spacecraft contaminants is presented as a guide for cognizant scientists and engineers.

Gross, F. C.↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗