Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rotor Performance Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Design of the Active Elevon Rotor for Low Vibration

Helicopter fuselages vibrate more than desired, and traditional solutions have limited effectiveness and can impose an appreciable weight penalty. Alternative methods of combating high vibration, including Higher Harmonic Control (HHC) via harmonic swashplate motion and Individual Blade Control (IBC) via active pitch links, have been studied for several decades. HHC via an on-blade control surface was tested in 1977 on a full scale rotor using a secondary active swashplate and a mechanical control system. Recent smart material advances have prompted new research into the use of on-blade control concepts. Recent analytical studies have indicated that the use of on-blade control surfaces produces vibration reduction comparable to swashplate-based HHC but for less power. Furthermore, smart materials (such as piezoceramics) have been shown to provide sufficient control authority for preliminary rotor experiments. These experiments were initially performed at small scale for reduced tip speeds. More recent experiments have been conducted at or near full tip speeds, and a full-scale active rotor is under development by Boeing with Eurocopter et al. pursuing a similarly advanced full-scale implementation. The US Army Aeroflightdynamics Directorate has undertaken a new research program called the Active Elevon Rotor (AER) Focus Demo. This program includes the design, fabrication, and wind. tunnel testing of a four-bladed, 12.96 ft diameter rotor with one or two on-blade elevons per blade. The rotor, which will be Mach scaled, will use 2-5/rev elevon motion for closed-loop control and :will be tested in late 2001. The primary goal of the AER Focus Demo is the reduction of vibratory hub loads by 80% and the reduction of vibratory blade structural loads. A secondary goal is the reduction of rotor power. The third priority is the measurement and possible reduction of Blade Vortex Interaction (BVI) noise. The present study is focused on elevon effectiveness, that is, the elevon's ability to reduce all six components of the nonrotating 4/rev hub loads. Some design parameters have been kept fixed in this study, while others have been varied to determine their influence - on elevon effectiveness. The fixed parameters include all blade structural properties except for torsion stiffness; the varied parameters include torsion stiffness, elevon aerodynamic location, and the number and individual authority of elevon aerodynamic surfaces. This paper describes the preliminary design process being used for the AER, and describes and quantifies the emerging active rotor characteristics.

Fulton, Mark V.↗

Effect of a reduction in blade thickness on performance of a single stage 20.32 centimeter mean diameter turbine

As part of a program to reduce the manufacturing costs of a small gas-turbine engine, the turbine blading was reduced in thickness to facilitate coining. Tests were made to determine the effect of this modification on turbine performance. The working fluid was air at nominal inlet total conditions of 535 deg F and 20.0 psia. Performance results are presented and compared for four stator-rotor combinations in terms of equivalent torque, mass flow, and efficiency at equivalent design speed and at inlet-total to exit-static pressure ratios of 1.8 to 3.8

Nusbaum, W. J.↗

Investigation of noise suppression by sonic inlets for turbofan engines. Volume 1: Program summary

Results of a program for sonic inlet technology development are presented. This program includes configuration and mechanical design selection of concepts, aerodynamic design description of the models, and results of test evaluation. Several sonic inlet concepts were tested and compared for aerodynamic and acoustic performance. Results of these comparative evaluations are presented. Near-field measurements were taken inside several of the inlet models. Results of these tests are discussed with respect to the effect of Mach number gradients on noise attenuation and rotor shock wave attenuation, and boundary layer effects on noise propagation. The test facilities and experimental techniques employed are described briefly.

Klujber, F.↗

Effects of tip clearance on overall performance of transonic fan stage with and without casing treatment

The overall performance of a transonic fan stage is presented for various tip clearances, with and without casing treatment. The stage was tested with a solid casing, and with open skewed slots and closed skewed slots in the casing over the rotor blade tips. Four nominal nonrotating rotor blade tip clearances from 0.061 to 0.178 centimeter were used. For all three casings, the pressure ratio and efficiency decreased with increasing tip clearance. The stall margin for a given casing also decreased with increasing clearance. At design speed and a given tip clearance, the highest stall margin was obtained with the open-slot casing, and the lowest stall margin was obtained with the solid casing.

Moore, R. D.↗

Cold-air performance of a tip turbine designed to drive a lift fan

Performance was obtained over a range of speeds and pressure ratios for a 0.4 linear scale version of the LF460 lift fan turbine with the rotor radial tip clearance reduced to about 2.5 percent of the rotor blade height. These tests covered a range of speeds from 60 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratios from 2.6 to 4.2. Results are presented in terms of equivalent mass flow, equivalent torque, equivalent specific work, and efficiency.

Haas, J. E.↗

Effect of rotor meridional velocity ratio on response to inlet radial and circumferential distortion

Three single transonic fan stages, each having a different meridional velocity ratio across its rotor, were tested with two magnitudes of tip radial distortion and with a 90 deg circumferential distortion imposed on the inlet flow. The rotor with the lowest meridional velocity ratio (less than 0.9 at the tip) demonstrated the least degradation of performance due to these distortions. Loss and deviation angle data (as needed for performance prediction with radial distortion) calculated along actual streamlines for radially distorted flow and correlated against diffusion factor, showed consistent agreement with data calculated along design streamlines for undistorted flow.

Sanger, N. L.↗

Rotating primary flow induction using jet-flapped blades

A new concept in ejector design is examined using primary jets exiting from a free spinning bladed rotor. This concept stems from a continuing effort in the development of Rotary-Jet thrust augmentors at George Washington University (GWU). An analysis of a Rotary-Jet rotor with jet-flapped blades is presented, identifying design trends beneficial to its performance. An experimental investigation was conducted to demonstrate the potential of this new concept. Several combinations of blade and shroud geometries were designed, fabricated and tested. The results are presented and discussed. Despite crudeness of fabrication, the maximum thrust augmentations obtained ranged from 1.55 to 2.14. These results demonstrate that this device is superior to all ejector designs tested with similar conventional passive diffusing shrouds.

Cordier, Stephane J.↗

Pattern classifier for health monitoring of helicopter gearboxes

The application of a newly developed diagnostic method to a helicopter gearbox is demonstrated. This method is a pattern classifier which uses a multi-valued influence matrix (MVIM) as its diagnostic model. The method benefits from a fast learning algorithm, based on error feedback, that enables it to estimate gearbox health from a small set of measurement-fault data. The MVIM method can also assess the diagnosability of the system and variability of the fault signatures as the basis to improve fault signatures. This method was tested on vibration signals reflecting various faults in an OH-58A main rotor transmission gearbox. The vibration signals were then digitized and processed by a vibration signal analyzer to enhance and extract various features of the vibration data. The parameters obtained from this analyzer were utilized to train and test the performance of the MVIM method in both detection and diagnosis. The results indicate that the MVIM method provided excellent detection results when the full range of faults effects on the measurements were included in training, and it had a correct diagnostic rate of 95 percent when the faults were included in training.

Chin, Hsinyung↗

Performance data for an axial-flow turbine with passive adaptive blades

To support the development of simulation tools for passive adaptive turbine rotors, an experimental data set from a laboratory-scale axial-flow turbine with passive adaptive blades is provided. The 0.45-meter diameter turbine was tested in the Alice C. Tyler Flume at the University of Washington. Blade and rotor loads were measured at 1 kHz using six-axis force/torque sensors while deflection and twist at the blade tip were tracked using a high-speed camera. This data submission includes a technical report, the raw and processed experimental data, and a README file explaining the file/folder structure and where to find the processing/plotting scripts used to produce the figures in the technical report.

16 TIDAL AND WAVE POWER↗

Perform a gyro test of general relativity in a satellite and develop associated control technology

The progress accomplished in the Stanford Gyro Relativity program during the period November 1974 to October 1975 was described. Gyro developments were continued in the main laboratory dewar, concentrating on the operation of a three axis gyro readout and on improvements to the methods of canceling trapped fields in the rotor; these efforts culminated in the first successful observation of the London moment in the spinning gyro rotor in March 1975. Following a review meeting at that time, a new goal was formulated for the next 12 to 18 months, namely to operate a gyroscope in the new ultra-low field facility with readout resolution approaching 1 arc-second. The following other tasks were also completed: (1) sputtering work, (2) magnetometry, (3) construction and installation of the North Star simulator, (4) analysis of torques on the gyro, especially in inclined orbits, (5) equivalence principle accelerometer, and (6) analysis of a twin-satellite test of relativity.

Fairbank, W. M.↗

Acoustic performance evaluation of an advanced UH-1 helicopter main rotor system

An experimental investigation of the high-speed impulsive noise characteristics of an advanced main rotor system for the UH-1 helicopter has been conducted. Models of both the advanced main rotor system and the UH-1 main rotor system were tested at one-quarter scale in the Langley 4- by 7-meter (V/STOL) Tunnel using the General Rotor Model System (GRMS). Tests were conducted over a range of simulated flight and descent velocities. The tunnel was operated in the open-throat configuration with acoustic treatment to improve the acoustic characteristics of the test chamber. In-plane acoustic measurements of the high-speed impulsive noise demonstrated a 7 to 8 dB reduction in noise generation is available by using the advanced rotor system on the UH-1 helicopter.

Hoad, D. R.↗

Near wake evolution of a tidal stream turbine due to asymmetric sheared turbulent inflow with different integral length scales

Tidal stream turbines deployed at highly energetic open water sites are subjected to sheared inflow in the rotor plane. The inflow shear is expected to cause asymmetric loading on the rotor blades and affect the downstream wake. In the current study, two different turbulent inflow conditions, static-high shear and dynamic shear, were generated via an active-grid turbulence generator. A 1:20 scaled three-bladed horizontal axis tidal turbine model was tested in those conditions. The results were compared to a quasi-laminar case with no imposed turbulence or shear. The results show that the high shear reduces the average performance, with a drop of up to 16% in the optimal power coefficient. Besides, the shear profiles increase torque fluctuations and induce significant differences in wake hydrodynamics between the high-speed (upper) and low-speed (lower) regions. The large integral length scales further enhance the load fluctuations perceived by the rotor but have a negligible effect on the mean wake field quantities and the wake recovery. The lower half region featured a faster breakdown of tip vortex structure and a rapid drop of swirl number, a phenomenon conjectured to be a consequence of the strong turbulence intensities and Reynolds stresses in the lower half region. Furthermore, the sheared turbulent inflow also results in a very intensive energy redistribution process towards large-scale, low-frequency motions, which is important to the downstream turbines.

16 TIDAL AND WAVE POWER↗

Testing of a stall flutter suppression system for helicopter rotors using individual-blade-control

The development and testing of a feedback system designed to alleviate rotor blade first torsion mode oscillations associated with stall flutter are described. The system employs blade-mounted sensors to detect torsional oscillations and provide feedback in order to increase the damping of the first torsional mode. A model of the blade and control system dynamics is developed and is used to give qualitative and quantitative guidance in the design process, as well as to aid in the analysis of experimental results. System performance in wind tunnel tests in forward flight is described, and experimental results show that the system can provide substantial additional damping to stall-induced oscillations.

Quackenbush, T. R.↗

Acoustics and Performance Characteristics of an Ideally Twisted Rotor in Hover

A series of experiments were conducted in an anechoic chamber to investigate the noise and performance of an ideally twisted rotor design, leading to validation of a low-fidelity aerodynamic performance and acoustic modeling tool chain. An "ideally twisted" rotor was designed in order to simplify the theoretical rotor inflow for a target thrust condition in hover. This rotor design was then fabricated using state-of-the-art rapid prototyping and tested in an anechoic chamber facility. Aerodynamic load and acoustic data were acquired across a range of rotation rates (RPM) and rotor collective settings in order to ascertain the accuracy of the low-fidelity modeling codes. Emphasis was placed on modeling of the broadband self-noise generated by the rotor system due to the fact that it was found to be a prominent contributor to the overall rotor system noise.

Nicole A. Pettingill↗

Acoustic and Performance Characteristics of an Ideally Twisted Rotor in Hover

A series of experiments were conducted in an anechoic chamber to investigate the noise and performance of an ideally twisted rotor design, leading to validation of a low-fidelity aerodynamic performance and acoustic modeling tool chain. An “ideally twisted” rotor was designed in order to simplify the theoretical rotor inflow for a target thrust condition in hover. This rotor design was then fabricated using state-of-the-art rapid prototyping and tested in an anechoic chamber. Aerodynamic load and acoustic data were acquired across a range of rotation rates and rotor collective settings in order to both identify noise trends and ascertain the accuracy of the low-fidelity modeling codes. Emphasis was placed on modeling of the broadband self-noise generated by the rotor system due to the fact that it was found to be a prominent contributor to the overall rotor system noise.

Nicole A Pettingill↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of range and distortion tolerance for high Mach number transonic fan stages. Task 2: Performance of a 1500-foot-per-second tip speed transonic fan stage with variable geometry inlet guide vanes and stator

A 0.5 hub/tip radius ratio compressor stage consisting of a 1500 ft/sec tip speed rotor, a variable camber inlet guide vane and a variable stagger stator was designed and tested with undistorted inlet flow, flow with tip radial distortion, and flow with 90 degrees, one-per-rev, circumferential distortion. At the design speed and design IGV and stator setting the design stage pressure ratio was achieved at a weight within 1% of the design flow. Analytical results on rotor tip shock structure, deviation angle and part-span shroud losses at different operating conditions are presented. The variable geometry blading enabled efficient operation with adequate stall margin at the design condition and at 70% speed. Closing the inlet guide vanes to 40 degrees changed the speed-versus-weight flow relationship along the stall line and thus provided the flexibility of operation at off-design conditions. Inlet flow distortion caused considerable losses in peak efficiency, efficiency on a constant throttle line through design pressure ratio at design speed, stall pressure ratio, and stall margin at the 0 degrees IGV setting and high rotative speeds. The use of the 40 degrees inlet guide vane setting enabled partial recovery of the stall margin over the standard constant throttle line.

Bilwakesh, K. R.↗