Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Mosquito Distribution and West Nile Virus Surveillance Results on the Nevada National Security Site in South Central Nevada

A 10-year study (2004-2013) was conducted to determine mosquito distribution and the prevalence of West Nile Virus (WNV) on the Nevada National Security Site (NNSS) in south central Nevada. Mosquito traps baited with dry ice were set overnight at sites where standing water provided potential breeding sites for mosquitoes. Captured mosquitoes were identified to species and tested for WNV. A total of 556 mosquitoes representing 6 species were captured and identified at 20 sites around the NNSS during 124 surveys. A vast majority (89%) of mosquitoes were Culex tarsalis. None of the mosquitoes tested were positive for WNV although 2 samples, both Culiseta inornata, were suspect for WNV in 2005 and 2006, both from Well 3 Pond. Additionally, 24 birds representing 5 species were opportunistically collected and tested for WNV with no positive results. Results from this study reveal patterns of mosquito distribution across the NNSS and suggest that NNSS workers have a very low risk of being exposed to WNV.

60 APPLIED LIFE SCIENCES↗

A surface work function measurement technique utilizing constant deflected grazing electron trajectories: Oxygen uptake on Cu(001)

We report on the application of a novel nondestructive in-vacuum technique for relative work function measurements, employing a grazing incidence electron deflection above a sample with a planar surface. Two deflected electron beam detectors are used as a position sensitive detector to control feedback to the sample potential as the sample work function changes. With feedback the sample potential exactly follows the surface sample-size averaged work function variation, so that the deflected beam trajectory remains stable. We also discuss methods to optimize the initial electron trajectories for this method, so as to minimize unwanted effects such as from uncontrolled external magnetic fields. As the electron beam does not impinge on the surface in this new technique electron induced desorption, ionization, dissociation, and/or decomposition is not induced at the interface. Importantly also the technique allows for free access to the surfaces enabling simultaneous deposition/evaporation and/or application of other surface characterization methods. We demonstrate its application in concurrent measurements of helium atom reflectivity and work function changes taking place during molecular oxygen exposure of a Cu(001) surface. A work function measurement sensitivity and stability is demonstrated at {approx}10 mV at a sampling rate of 1 Hz and after application of an {approx}7 s smoothing routine. In comparison to the helium atom reflectivity measurements, the work function measurements are more sensitive to the initial O uptake, and less so to the final coverage variations and possible surface reordering at higher O coverages.

43 PARTICLE ACCELERATORS↗

Computing Proximity to Threat Along Uncertain Trajectory to Support Urban Air Mobility

Many airspace threats affect the selection of a flight route, such as terrain, physical obstacles, adverse weather, and special-use airspace, among others. Threat avoidance during Urban Air Mobility (UAM) and Low Altitude Mobility (LAM) flights is especially challenging due to their lower cruising altitudes. These operations may be exposed to buildings, towers, trees, terrain undulations, etc., along much of their flight route. Moreover, these low-altitude flights in urban environments are expected to encounter very busy airspace, increasing the workload associated with threat avoidance. The Proximity to Threat (PtT) function aims to support onboard or remote pilots by computing the risk from geospatial threats in the airspace along an aircraft’s flight path. The threats are both static entities and dynamic airspace restrictions that have been modeled and stored in geo-referenced mapping databases. The flight path may be specified by waypoints, airways, or similar discrete route elements or by a time series of closely spaced position and altitude points. Flight path uncertainty can also be taken into account by assuming both the position and altitude to be sampled from two normal distributions, each being specified by a mean and variance. PtT uses this additional information to verify that the flight path remains clear of threats along a wider path or if a position is reached earlier or later than anticipated, assuring the pilot or operator that there will be an available safety margin even if the aircraft deviates due to one or more occurrences of unexpected wind gusts, mechanical failures, airspeed changes, collision avoidance maneuvers, etc. The client can specify an uncertainty confidence level to bound the set of trajectories evaluated for threats so that the confidence level corresponds to the client’s risk tolerance under the expected conditions. PtT can be used as a pre-flight planning tool to determine a safe route through known threats and in-flight to avoid emerging or changing threats. In this report, we present the PtT function, discuss how the trajectory uncertainty is incorporated into the PtT function, and describe the use of this PtT function in a representative scenario.

urban air mobility↗

SU-F-E-09: Respiratory Signal Prediction Based On Multi-Layer Perceptron Neural Network Using Adjustable Training Samples

Purpose: Dynamic tracking of moving organs, such as lung and liver tumors, under radiation therapy requires prediction of organ motions prior to delivery. The shift of moving organ may change a lot due to huge transform of respiration at different periods. This study aims to reduce the influence of that changes using adjustable training signals and multi-layer perceptron neural network (ASMLP). Methods: Respiratory signals obtained using a Real-time Position Management(RPM) device were used for this study. The ASMLP uses two multi-layer perceptron neural networks(MLPs) to infer respiration position alternately and the training sample will be updated with time. Firstly, a Savitzky-Golay finite impulse response smoothing filter was established to smooth the respiratory signal. Secondly, two same MLPs were developed to estimate respiratory position from its previous positions separately. Weights and thresholds were updated to minimize network errors according to Leverberg-Marquart optimization algorithm through backward propagation method. Finally, MLP 1 was used to predict 120∼150s respiration position using 0∼120s training signals. At the same time, MLP 2 was trained using 30∼150s training signals. Then MLP is used to predict 150∼180s training signals according to 30∼150s training signals. The respiration position is predicted as this way until it was finished. Results: In this experiment, the two methods were used to predict 2.5 minute respiratory signals. For predicting 1s ahead of response time, correlation coefficient was improved from 0.8250(MLP method) to 0.8856(ASMLP method). Besides, a 30% improvement of mean absolute error between MLP(0.1798 on average) and ASMLP(0.1267 on average) was achieved. For predicting 2s ahead of response time, correlation coefficient was improved from 0.61415 to 0.7098.Mean absolute error of MLP method(0.3111 on average) was reduced by 35% using ASMLP method(0.2020 on average). Conclusion: The preliminary results demonstrate that the ASMLP respiratory prediction method is more accurate than MLP method and can improve the respiration forecast accuracy.

60 APPLIED LIFE SCIENCES↗

Quantitative Detection of Single Molecules in Fluorescence Microscopy Images

Fluorescence imaging and counting of single molecules adsorbed or bound to surfaces are being employed in a number of quantitative analysis applications. Reliable molecular counts with knowledge of counting uncertainties, both false-positive and false-negative probabilities, are critical to these applications. By counting stationary single molecules on a surface, spatial criteria may be applied to the image analysis to improve confidence in detection, which is especially critical when detecting single fluorescent labels. In this work, we describe a simple approach to incorporating spatial criteria for counting single molecules by using an intensity threshold to locate regions with multiple, adjacent intense pixels, where the size of these regions is guided by the point-spread function of the microscope. By requiring multiple, spatially correlated bright pixels, false-positive events resulting from random samples of background noise are minimized. The reliability of detection is established by quantitative knowledge of the distributions of background and signals. By measuring and modeling both the background and single-molecule intensity distributions, false-positive and false-negative detection probabilities are estimated for arbitrary threshold parameters by using combinatorial statistics. From this theory, detection parameters can be optimized to minimize false-positive and false-negative probabilities, which can be calculated explicitly. For detection of single rhodamine 6G molecules at a threshold set at 2.5 times the standard deviation above background, the false-negative probability was only 1.5%, determined from distributions of single-molecule intensities on well-populated surfaces, and the false-positive probability from background noise was 2.8 spots per 50 × 50 μm image. Furthermore, the false-positive events compare favorably with theoretical probabilities calculated using combinatorial statistical analysis and simulated false-positive events counted in images of random noise.

36 MATERIALS SCIENCE↗

Circulating Tumour Cell Numbers Correlate with Platelet Count and Circulating Lymphocyte Subsets in Men with Advanced Prostate Cancer: Data from the ExPeCT Clinical Trial (CTRIAL-IE 15-21)

Interactions between circulating tumour cells (CTCs) and platelets are thought to inhibit natural killer(NK)-cell-induced lysis. We attempted to correlate CTC numbers in men with advanced prostate cancer with platelet counts and circulating lymphocyte numbers. Sixty-one ExPeCT trial participants, divided into overweight/obese and normal weight groups on the basis of a BMI ≥ 25 or <25, were randomized to participate or not in a six-month exercise programme. Blood samples at randomization, and at three and six months, were subjected to ScreenCell filtration, circulating platelet counts were obtained, and flow cytometry was performed on a subset of samples (n = 29). CTC count positively correlated with absolute total lymphocyte count (r 2 = 0.1709, p = 0.0258) and NK-cell count (r 2 = 0.49, p < 0.0001). There was also a positive correlation between platelet count and CTC count (r 2 = 0.094, p = 0.0001). Correlation was also demonstrated within the overweight/obese group (n = 123, p < 0.0001), the non-exercise group (n = 79, p = 0.001) and blood draw samples lacking platelet cloaking (n = 128, p < 0.0001). By flow cytometry, blood samples from the exercise group (n = 15) had a higher proportion of CD3+ T-lymphocytes (p = 0.0003) and lower proportions of B-lymphocytes (p = 0.0264) and NK-cells (p = 0.015) than the non-exercise group (n = 14). These findings suggest that CTCs engage in complex interactions with the coagulation cascade and innate immune system during intravascular transit, and they present an attractive target for directed therapy at a vulnerable stage in metastasis.

60 APPLIED LIFE SCIENCES↗

Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and not in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.

59 BASIC BIOLOGICAL SCIENCES↗

Carbon in comet dust

The association of Halley particle results with data from existing meteoritic materials that can be analyzed in the laboratory is discussed. Comet samples must exist in present collections of meteoritic materials and the Halley results provide clues for identifying them. Although it is not presently possible to positively identify cometary meteorites or cometary interplanetary dust (IDP) samples, it is possible to determine which materials are similar to Halley dust and which ones are distinctly unlike Halley. The properties of these existing Halley-compatible samples provide insight into the possible properties of cometary material. Positive identification of meteoritic comet samples or direct samples returned from a comet nucleus would of course revolutionize our ability to study carbonaceous matter in comets. Modern analytical techniques are very powerful and it is possible to perform elemental, chemical, mineralogical and even limited isotopic analysis on micron-size particles. There is an important synergism between the laboratory studies of collected samples and astronomical data from comets and interstellar grains. To fully interpret results there must be convincing methods for associating a particular class or classes of meteoritic material with comets. Ultimately this will be done by direct comet sample return such as the Rosetta mission under development by ESA. At the present time the only links that can be made involve comparison with sample properties and measurable properties of comets. Unfortunately there is at present no known unique property of cometary dust that allows its absolute identification in the laboratory. The results from Halley encounters and observation do provide much new information on cometary grains. The Halley grain compositions, density, size distribution and scattering properties all provide a basis for future investigations. Other Halley properties such as the presence of polyoxymethylene and the 3.4um emission feature could play key roles for making convincing links in the future.

Brownlee, D. E.↗

Nodal Clearance Rate and Long-Term Efficacy of Individualized Sentinel Node–Based Pelvic Intensity Modulated Radiation Therapy for High-Risk Prostate Cancer

Purpose: To assess the efficacy of individual sentinel node (SN)-guided pelvic intensity modulated radiation therapy (IMRT) by determining nodal clearance rate [(n expected nodal involvement − n observed regional recurrences)/n expected nodal involvement] in comparison with surgically staged patients. Methods and Materials: Data on 475 high-risk prostate cancer patients were examined. Sixty-one consecutive patients received pelvic SN-based IMRT (5 × 1.8 Gy/wk to 50.4 Gy [pelvic nodes + individual SN] and an integrated boost with 5 × 2.0 Gy/wk to 70.0 Gy to prostate + [base of] seminal vesicles) and neo-/adjuvant long-term androgen deprivation therapy; 414 patients after SN–pelvic lymph node dissection were used to calculate the expected nodal involvement rate for the radiation therapy sample. Biochemical control and overall survival were estimated for the SN-IMRT patients using the Kaplan-Meier method. The expected frequency of nodal involvement in the radiation therapy group was estimated by imputing frequencies of node-positive patients in the surgical sample to the pattern of Gleason, prostate-specific antigen, and T category in the radiation therapy sample. Results: After a median follow-up of 61 months, 5-year OS after SN-guided IMRT reached 84.4%. Biochemical control according to the Phoenix definition was 73.8%. The nodal clearance rate of SN-IMRT reached 94%. Retrospective follow-up evaluation is the main limitation. Conclusions: Radiation treatment of pelvic nodes individualized by inclusion of SNs is an effective regional treatment modality in high-risk prostate cancer patients. The pattern of relapse indicates that the SN-based target volume concept correctly covers individual pelvic nodes. Thus, this SN-based approach justifies further evaluation, including current dose-escalation strategies to the prostate in a larger prospective series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure of the multiple-filamentation zone formed by femtosecond laser radiation in a solid dielectric

The regularities of multiple filamentation of gigawatt femtosecond laser pulses in a solid dielectric (optical glass) have been considered. The fine spatial structure of the plasma region that is formed under glass photoionisation and accompanies the formation of light filaments is analysed experimentally and by means of numerical simulation. The dependence of the number, position, and extension of individual 'generations' of plasma channels on the laser pulse energy has been investigated for the first time. It is found that the distribution of the number of plasma channels over the length of a dielectric sample has a maximum, the position of which correlates well with the position of the nonlinear focus of the light beam as a whole; at the same time, the average channel length decreases with increasing pulse power, whereas the number of successive channel 'generations', on the contrary, increases. (interaction of laser radiation with matter. laser plasma)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Circuit for Driving Piezoelectric Transducers

The figure schematically depicts an oscillator circuit for driving a piezoelectric transducer to excite vibrations in a mechanical structure. The circuit was designed and built to satisfy application-specific requirements to drive a selected one of 16 such transducers at a regulated amplitude and frequency chosen to optimize the amount of work performed by the transducer and to compensate for both (1) temporal variations of the resonance frequency and damping time of each transducer and (2) initially unknown differences among the resonance frequencies and damping times of different transducers. In other words, the circuit is designed to adjust itself to optimize the performance of whichever transducer is selected at any given time. The basic design concept may be adaptable to other applications that involve the use of piezoelectric transducers in ultrasonic cleaners and other apparatuses in which high-frequency mechanical drives are utilized. This circuit includes three resistor-capacitor networks that, together with the selected piezoelectric transducer, constitute a band-pass filter having a peak response at a frequency of about 2 kHz, which is approximately the resonance frequency of the piezoelectric transducers. Gain for generating oscillations is provided by a power hybrid operational amplifier (U1). A junction field-effect transistor (Q1) in combination with a resistor (R4) is used as a voltage-variable resistor to control the magnitude of the oscillation. The voltage-variable resistor is part of a feedback control loop: Part of the output of the oscillator is rectified and filtered for use as a slow negative feedback to the gate of Q1 to keep the output amplitude constant. The response of this control loop is much slower than 2 kHz and, therefore, does not introduce significant distortion of the oscillator output, which is a fairly clean sine wave. The positive AC feedback needed to sustain oscillations is derived from sampling the current through the piezoelectric transducer. This positive AC feedback, in combination with the slow feedback to the voltage-variable resistors, causes the overall loop gain to be just large enough to keep the oscillator running. The positive feedback loop includes two 16-channel multiplexers, which are not shown in the figure. One multiplexer is used to select the desired piezoelectric transducer. The other multiplexer, which is provided for use in the event that there are significant differences among the damping times of the 16 piezoelectric transducers, facilitates changing the value of one of the resistors in the positive-feedback loop to accommodate the damping time of the selected transducer.

Randall, David P.↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

TU-F-17A-05: Calculating Tumor Trajectory and Dose-Of-The-Day for Highly Mobile Tumors Using Cone-Beam CT Projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed a method using these projections to determine the trajectory and dose of highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, where the trajectory mimicked a lung tumor with high amplitude (2.4 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each projection. A Gaussian probability density function for tumor position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two methods to improve the accuracy of tumor track reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation, and second, using the Monte Carlo method to sample the estimated Gaussian tumor position distribution. 15 clinically-drawn abdominal/lung CTV volumes were used to evaluate the accuracy of the proposed methods by comparing the known and calculated BB trajectories. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square (RMS) trajectory errors were lower than 5% of marker amplitude. Use of respiratory phase information decreased RMS errors by 30%, and decreased the fraction of large errors (>3 mm) by half. Mean dose to the clinical volumes was calculated with an average error of 0.1% and average absolute error of 0.3%. Dosimetric parameters D90/D95 were determined within 0.5% of maximum dose. Monte-Carlo sampling increased RMS trajectory and dosimetric errors slightly, but prevented over-estimation of dose in trajectories with high noise. Conclusions: Tumor trajectory and dose-of-the-day were accurately calculated using CBCT projections. This technique provides a widely-available method to evaluate highly-mobile tumors, and could facilitate better strategies to mitigate or compensate for motion during SBRT.

60 APPLIED LIFE SCIENCES↗

Calculations and experiments concerning lifting force and power in TEMPUS

A critical comparison is reported between the theoretically predicted and experimentally measured values for the electromagnetic lifting force and the heating rates which may be achieved, under simulated microgravity conditions, using the TEMPUS electromagnetic levitation device. The experiments involved the suspending of a metallic sample from one arm of a recording balance, such that it was carefully positioned between the heating and the positioning coils of the levitation device. The net force exerted by the sample was measured as a function of position, the coil currents, and the nature of the sample. Some calculations are also reported regarding the power absorption by the sample. The theoretical predictions, based on the numerical solution of Maxwell's equations using the volume integral technique, were found to be in excellent agreement with the measurements. For the idealized case of a spherical sample, analytical solutions describing the lifting force were also found to agree very well with the computed results.

Zong, J. H.↗

Calculating tumor trajectory and dose-of-the-day using cone-beam CT projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. The authors developed and validated a method which uses these projections to determine the trajectory of and dose to highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, the trajectory of which mimicked a lung tumor with high amplitude (up to 2.5 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each CBCT projection, and a Gaussian probability density function for the absolute BB position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two modifications of the trajectory reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation (Phase), and second, using the Monte Carlo (MC) method to sample the estimated Gaussian tumor position distribution. The accuracies of the proposed methods were evaluated by comparing the known and calculated BB trajectories in phantom-simulated clinical scenarios using abdominal tumor volumes. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square trajectory errors averaged 3.8% ± 1.1% of the marker amplitude. Dosimetric calculations using Phase methods were more accurate, with mean absolute error less than 0.5%, and with error less than 1% in the highest-noise trajectory. MC-based trajectories prevent the overestimation of dose, but when viewed in an absolute sense, add a small amount of dosimetric error (<0.1%). Conclusions: Marker trajectory and target dose-of-the-day were accurately calculated using CBCT projections. This technique provides a method to evaluate highly mobile tumors using ordinary CBCT data, and could facilitate better strategies to mitigate or compensate for motion during stereotactic body radiotherapy.

60 APPLIED LIFE SCIENCES↗

Characterization of Microbial Communities in Subsurface Nuclear Blast Cavities of the Nevada Test Site

This exploratory research project is designed to test fundamental hypotheses concerning the possible existence and nature of indigenous microbial populations in Nevada Test Site (NTS) subsurface nuclear blast cavities. Although subsurface microbiological studies have been performed at the NTS in the past, radioactive zones have yet to be addressed. Nuclear blast zone microbiology is a completely new field and our team is well-positioned to collect and analyze samples that have never before been available to microbiologists. Relevant samples are now being obtained by incorporating microbiological collections into an ongoing annual hot well sampling program being conducted by other agencies. A combination of cultivation-based and molecular microbial detection protocols is being utilized at multiple locations to survey for uncultivable microorganisms and to develop a culture collection which will be characterized for radionuclide- and metal-reduction capabilities. Given that redox manipulations mediated by microorganisms can impact the mobility of DOE contaminants, a positive outcome from this work would have significant implications for management strategies at this and other DOE sites. A primary objective of the project has been the establishment of the regulatory and technical framework necessary to enable our acquisition of samples. Thus, much of our activity in the first phase of this work has involved the development an approved Field Area Work Plan (FAWP), Radiological Work Permit (RWP), and other documentation required for radiological work at the NTS. We have also invested significant time into ensuring that all personnel possess the required training (e.g. Radworker II and 40 hr. HAZWOPER) for access to the hot well sampling sites. Laboratory facilities, required for field processing of radioactive samples as well as DNA extraction and other manipulations, have been secured both the NTS (Mercury, NV) and UNLV. Although our year-1 field work was delayed due to non-availability of samples, an aggressive sampling campaign is now underway and our first hot well samples were collected on Feb 5th, 2008. The unique nature of this site, coupled with the combined expertise of the collaborating laboratories (DRI, LLNL, PNNL, and the Harry Reid Center) makes the likelihood of our achieving discoveries of value to DOE, the individual researchers, and society high. As the selective pressures at atomic blast sites are probably different from those of production and disposal sites, these habitats may contain novel organisms of utility for bioremediation. Such organisms will have had to develop physiological mechanisms to survive high doses of ionizing radiation over the variety of rock types and hydrologic environments present at the NTS.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Building 3430 Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Pathway Stack . The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Pathway stack. Therefore, this new system also meets the qualification criteria given in the ANSI/HPS N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliance to the requirements.

54 ENVIRONMENTAL SCIENCES↗

Assessment of mercury exposure among small-scale gold miners using mercury stable isotopes

Total mercury (Hg) concentrations in hair and urine are often used as biomarkers of exposure to fish-derived methylmercury (MeHg) and gaseous elemental Hg, respectively. We used Hg stable isotopes to assess the validity of these biomarkers among small-scale gold mining populations in Ghana and Indonesia. Urine from Ghanaian miners displayed similar Δ{sup 199}Hg values to Hg derived from ore deposits (mean urine Δ{sup 199}Hg=0.01‰, n=6). This suggests that urine total Hg concentrations accurately reflect exposure to inorganic Hg among this population. Hair samples from Ghanaian miners displayed low positive Δ{sup 199}Hg values (0.23–0.55‰, n=6) and low percentages of total Hg as MeHg (7.6–29%, n=7). These data suggest that the majority of the Hg in these miners' hair samples is exogenously adsorbed inorganic Hg and not fish-derived MeHg. Hair samples from Indonesian gold miners who eat fish daily displayed a wider range of positive Δ{sup 199}Hg values (0.21–1.32‰, n=5) and percentages of total Hg as MeHg (32–72%, n=4). This suggests that total Hg in the hair samples from Indonesian gold miners is likely a mixture of ingested fish MeHg and exogenously adsorbed inorganic Hg. Based on data from both populations, we suggest that total Hg concentrations in hair samples from small-scale gold miners likely overestimate exposure to MeHg from fish consumption. - Highlights: • Mercury isotopes were measured in hair and urine from small-scale gold miners. • Mercury isotopes indicate that Hg in urine comes from mining activity. • Mercury isotopes suggest Hg in hair is a mixture of fish MeHg and inorganic Hg. • A large percentage of Hg in miner’s hair is released during amalgam burning and adsorbed.

54 ENVIRONMENTAL SCIENCES↗