Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Results for the April 2024 Semiannual Salt Waste Processing Facility Decontaminated Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the April 2024 Semiannual sample of the Salt Waste Processing Facility (SWPF) Decontaminated Salt Solution (DSS) salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from SWPF to the Saltstone Production Facility (SPF) where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the SWPF DSS sample was obtained.1 The April 2024 Semiannual sample of the SWPF DSS is a composite from the six months of SWPF processing during the First Quarter Fiscal Year 2024 (1QFY2024) and the Second Quarter Fiscal Year 2024 (2QFY2024). The following facts pertaining to the WAC are drawn from the analytical results provided in this report. WAC TARGETS and LIMITS were met for all analyzed chemical and radioactive contaminants for which the detection limits are below the WAC TARGETS and LIMITS. Nitrosamines were not detected in the SWPF DSS salt solution sample above the instrument detection limits of <1 mg/L. The minimum detection limit (<3.33E-01 pCi/mL) is reported for 94 Nb as determined from the minimum detectable activity associated with the radiochemical method used for this radionuclide. The reported detection limit is above the requested SRMC target minimum detection limit concentration. However, the minimum detection limit reported for the April 2024 semiannual SWPF DSS sample for 94 Nb is lower than the estimated detection limit of 4.38E-01 pCi/mL initially established by SRNL in 2009. Thus, per guidance from SRMC, 2 SRNL continues to achieve as low as practical detection limits for this radionuclide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gamma-Ray Emitting Radionuclides Concentrations and Decontamination Factors of ATR Loop Liquid Samples Cycle 173A Revision 0

This report contains the gamma-ray emitting radionuclides concentration and decontamination factor results from gamma-ray spectrometry measurements of ATR loop liquid samples by the Radiation Measurements Laboratory (RML) for ATR Cycle 173A running May 3, 2024, to July 6, 2024. This report consists of five subsections, one for each loop. Each subsection contains the results for each sampling of the loop along with the date and time of sampling, spectral data identifications, sample type, and reactor power (MW). The results are reported in units of disintegrations per minute per milliliter of sample. The results are obtained with the gamma-ray spectral data analysis routines of the RML computer. Some of this report is also generated by RML data storage and handling routines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Tank 38H (HTF-38-26-16, -17), Tank 43H (HTF 43-26-18, -19) and Tank 22 (HTF-22-26-20, -21) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory (SRNL) analyzed samples from Tank 38H, Tank 43H and Tank 22H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample are ~ 76% of the concentrations in the previous Tank 38H surface sample. The current Tank 38H subsurface sample is a clear solution with soluble species that are ~ 70% of the concentrations in the previous Tank 38H subsurface. Significant differences in the concentrations of major components between the current Tank 38H surface and subsurface samples indicate stratification of solution species between these two locations within Tank 38H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Sample Size While Improving Equity in Vaccine Clinical Trials: A Machine Learning-Based Recruitment Methodology with Application to Improving Trials of Hepatitis C Virus Vaccines in People Who Inject Drugs

Despite the availability of direct-acting antivirals that cure individuals infected with the hepatitis C virus (HCV), developing a vaccine is critically needed in achieving HCV elimination. HCV vaccine trials have been performed in populations with high incidence of new HCV infection such as people who inject drugs (PWID). Developing strategies of optimal recruitment of PWID for HCV vaccine trials could reduce sample size, follow-up costs and disparities in enrollment. We investigate trial recruitment informed by machine learning and evaluate a strategy for HCV vaccine trials termed PREDICTEE—Predictive Recruitment and Enrichment method balancing Demographics and Incidence for Clinical Trial Equity and Efficiency. PREDICTEE utilizes a survival analysis model applied to trial candidates, considering their demographic and injection characteristics to predict the candidate’s probability of HCV infection during the trial. The decision to recruit considers both the candidate’s predicted incidence and demographic characteristics such as age, sex, and race. We evaluated PREDICTEE using in silico methods, in which we first generated a synthetic candidate pool and their respective HCV infection events using HepCEP, a validated agent-based simulation model of HCV transmission among PWID in metropolitan Chicago. We then compared PREDICTEE to conventional recruitment of high-risk PWID who share drugs or injection equipment in terms of sample size and recruitment equity, with the latter measured by participation-to-prevalence ratio (PPR) across age, sex, and race. Comparing conventional recruitment to PREDICTEE found a reduction in sample size from 802 (95%: 642–1010) to 278 (95%: 264–294) with PREDICTEE, while also reducing screening requirements by 30%. Simultaneously, PPR increased from 0.475 (95%: 0.356–0.568) to 0.754 (95%: 0.685–0.834). Even when targeting a dissimilar maximally balanced population in which achieving recruitment equity would be more difficult, PREDICTEE is able to reduce sample size from 802 (95%: 642–1010) to 304 (95%: 288–322) while improving PPR to 0.807 (95%: 0.792–0.821). PREDICTEE presents a promising strategy for HCV clinical trial recruitment, achieving sample size reduction while improving recruitment equity.

60 APPLIED LIFE SCIENCES↗

Preliminary description of Apollo 15 sample environments

Approximately 78 kg of lunar rock and soil samples were returned by Apollo 15. The rather complete documentation of the locations of nearly all of the samples allows for relating the samples to the specific and detailed geologic environments from which they were collected. This is especially important in an area as geologically complex as the Hadley-Apennine site. All of the material presented was derived from the pre-mission photogeologic maps, lunar surface television video tapes, air-to-ground transcript and crew debriefings, photographs taken on the lunar surface by the Apollo 15 crew, and information supplied by the Lunar Sample Preliminary Examination team from which the samples were categorized into groups consisting of, broadly, basalts and breccias. The breccias are considered loosely in terms of coherent breccias and soil breccias.

Swann, G. A.↗

Infrared and Raman spectroscopic studies of structural variations in minerals from Apollo 11, 12, 14 and 15 samples, volume 3

Infrared and Raman vibrational spectroscopic data, yielding direct information on molecular structure, were obtained for single grains ( 150 microns) of minerals, basalts, and glasses isolated from Apollo 11, 12, 14, and 15 rock and dust samples, and for grains in Apollo 14 polished butt samples. From the vibrational data, specification substitutions were determined for the predominant silicate minerals of plagioclase, pyroxene, and olivine. Unique spectral variations for grains of K-feldspar, orthopyroxene, pyroxenoid, and ilmenite were observed to exceed the ranges of terrestrial samples, and these variations may be correlatable with formation histories. Alpha-quartz was isolated as pure single grains, in granitic grains composited with sanidine, and in unique grains that were intimately mixed with varying amounts of glass. Accessory minerals of chromite and ulvospinel were isolated as pure grains and structurally characterized from their distinctive infrared spectra. Fundamental vibrations of the SiO4 tetrahedra in silicate minerals were used to classify bulk compositions in dust sieved fractions, basalt grains and glass particles, and to compare modal characteristics for maria, highland and rille samples. No hydrated minerals were found in any of the samples studied, indicating anhydrous formation conditions.

Estep, P. A.↗

Digital adaptive sampling.

Discussion of digital adaptive sampling, which is consistently better than fixed sampling in noise-free cases. Adaptive sampling is shown to be feasible and, it is considered, should be studied further. It should be noted that adaptive sampling is a class of variable rate sampling in which the variability depends on system signals. Digital rather than analog laws should be studied, because cases can arise in which the analog signals are not even available. An extremely important problem is implementation.

Breazeale, G. J.↗

Nondestructive determination of radionuclides in lunar samples using a large low-background gamma-ray spectrometer and a novel application of least-squares fitting

Dual-parameter gamma ray spectrometer systems with large volume Nal (Tl) crystals and low backgrounds were used for nondestructive determination of K, Th, U and cosmic ray produced radionuclides in 60 lunar samples. The total weight of samples measured with this system is 28 kg, and the individual sample weights varied from 2 to 2300 g. Samples from Apollo 11, 12, 14, 15 and 16 were measured. Operation of the spectrometers in the coincidence mode and analyzing single coincidence spectra permits the simultaneous determination of 8-10 radionuclides in each lunar sample.

Eldridge, J. S.↗

Automatic instrument for chemical processing to detect microorganism in biological samples by measuring light reactions

An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.

Kelbaugh, B. N.↗

Micro-organism distribution sampling for bioassays

Purpose of sampling distribution is to characterize sample-to-sample variation so statistical tests may be applied, to estimate error due to sampling (confidence limits) and to evaluate observed differences between samples. Distribution could be used for bioassays taken in hospitals, breweries, food-processing plants, and pharmaceutical plants.

Nelson, B. A.↗

Trace-element analysis of 1000 environmental samples per year using instrumental neutron activation analysis

The technology and methods developed at the Plum Brook Reactor to analyze 1000 samples per year and report data on as many as 56 elements are described. The manpower for the complete analysis of 20 to 24 samples per week required only 3 to 3.5 hours per sample. The solutions to problems encountered in sample preparation, irradiation, and counting are discussed. The automation of data reduction is described. Typical data on various sample matrices are presented.

Sheibley, D. W.↗

An error criterion for determining sampling rates in closed-loop control systems

The determination of an error criterion which will give a sampling rate for adequate performance of linear, time-invariant closed-loop, discrete-data control systems was studied. The proper modelling of the closed-loop control system for characterization of the error behavior, and the determination of an absolute error definition for performance of the two commonly used holding devices are discussed. The definition of an adequate relative error criterion as a function of the sampling rate and the parameters characterizing the system is established along with the determination of sampling rates. The validity of the expressions for the sampling interval was confirmed by computer simulations. Their application solves the problem of making a first choice in the selection of sampling rates.

Brecher, S. M.↗

Effects of cesium ions and cesium vapor on selected ATS-F samples

Thermal control coating samples were subjected to cesium ion beam and vapor exposures. Degradation of solar absorptance and infrared emittance were measured. Solar cells and samples selected from surfaces on the ATS-F spacecraft likely to experience ion or vapor impingement were bombarded by 10-volt cesium ions. Other samples were subjected to high levels of cesium vapor. Aluminum and white paint were backsputtered by 550-volt cesium ions onto selected samples. For direct bombardment, the threshold for ion-induced property changes was above five-thousand trillion ions/sq cm. With material sputtered from a 450-sq cm target onto samples 36 cm distant, the threshold for noticeable effects was above 5 times 10 to the 17-th power ions/sq cm.

Kemp, R. F.↗

Quantizing and sampling considerations in digital phased-locked loops

The quantizer problem is first considered. The conditions under which the uniform white sequence model for the quantizer error is valid are established independent of the sampling rate. An equivalent spectral density is defined for the quantizer error resulting in an effective SNR value. This effective SNR may be used to determine quantized performance from infinitely fine quantized results. Attention is given to sampling rate considerations. Sampling rate characteristics of the digital phase-locked loop (DPLL) structure are investigated for the infinitely fine quantized system. The predicted phase error variance equation is examined as a function of the sampling rate. Simulation results are presented and a method is described which enables the minimum required sampling rate to be determined from the predicted phase error variance equations.

Hurst, G. T.↗

Volatile element chemistry of selected lunar, meteoritic, and terrestrial samples

Using vacuum pyrolysis and high resolution mass spectrometry, a study is made of the gas release patterns of representative lunar samples, meteorites, terrestrial samples, and synthetic samples doped with various sources of carbon and nitrogen. The pyrolytic gas evolution patterns were intercorrelated, allowing an assessment of the possible sources of the volatilizable material in the lunar samples to be made. Lightly surface adsorbed species and more strongly chemisorbed species are released from ambient to 300 C and from 300 to 500 C, respectively. The low-temperature volatiles (less than 500 C) derived from various chondrites correlate well with the gas evolution patterns of volatile-rich samples, as for example 74220 and 61221. Solar wind entrapped species and molecules derived from reactions probably in the grain surfaces are evolved from about 500 to 700 C, respectively. Solar wind implanted C, N, and S species are generated from 750 to 1150 C, probably by reaction with the mineral matrix during the annealing process. Possible indigenous and/or refractory carbide, nitride, and sulfide C, N, and S are released in the region from 1200 C to fusion.

Simoneit, B. R.↗

Evaluations of lunar samples for the presence of viable organisms

Samples from the six successful Apollo lunar exploration missions were examined for the presence of biological formed elements and were used to inoculate a variety of culture media designed to promote growth of a broad spectrum of microorganisms. No evidence of viable organisms was obtained from any of these analyses. Following incubation of the lunar material-culture medium complexes, microbial growth dynamics studies were conducted with known test species to evaluate the possible presence of toxic factors. Only extracts of culture media which had been in contact with a mixture of lunar material from both Apollo 11 core tubes proved to be toxic to all species tested. Attempts to reproduce this toxic effect with individual Apollo 11 core samples obtained at other parts of the core and analyzed under somewhat different conditions were unsuccessful. In all, 48 different lunar samples were examined. These samples were collected at the lunar surface, in trenches, and in core samples to a depth of 297 cm.

Taylor, G. R.↗

Preparation, testing and analysis of zinc diffusion samples, NASA Skylab experiment M-558

Transport mechanisms of zinc atoms in molten zinc were investigated by radiotracer techniques in unit and in near-zero gravity environments. Each melt in the Skylab flight experiments was maintained in a thermal gradient of 420 C to 790 C. Similar tests were performed in a unit gravity environment for comparison. After melting in the gradient furnace followed by a thermal soak period (the latter was used for flight samples only), the samples were cooled and analyzed for Zn-65 distribution. All samples melted in a unit gravity environment were found to have uniform Zn-65 distribution - no concentration gradient was observed even when the sample was brought rapidly to melting and then quenched. Space-melted samples, however, showed textbook distributions, obviously the result of diffusion. It was evident that convection phenomena were the dominant factors influencing zinc transport in unit gravity experiments, while diffusion was the dominant factor in near-zero gravity experiments.

Braski, D. N.↗

Investigation to develop a multistage forest sampling inventory system using ERTS-1 imagery

The author has identified the following significant results. The annotation system produced a RMSE of about 200 m ground distance in the MSS data system with the control data used. All the analytical MSS interpretation models tried were highly significant. However, the gains in forest sampling efficiency that can be achieved by using the models vary from zero to over 50 percent depending on the area to which they are applied and the sampling method used. Among the sampling methods tried, regression sampling yielded substantial and the most consistent gains. The single most significant variable in the interpretation model was the difference between bands 5 and 7. The contrast variable, computed by the Hadamard transform was significant but did not contribute much to the interpretation model. Forest areas containing very large timber volumes because of large tree sizes were not separable from areas of similar crown cover but containing smaller trees using ERTS image interpretation only. All correlations between space derived timber volume predictions and estimates obtained from aerial and ground sampling were relatively low but significant and stable. There was a much stronger relationship between variables derived from MSS and U2 data than between U2 and ground data.

Langley, P. G.↗