Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sheath”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Total Recycling of Copper Cable Scrap and Production of Carbon Using Fast Microwave Technology

The recycling of cable scrap, particularly from discarded electrical wiring, is gaining significant attention due to the rising demand for copper and the need for sustainable management of electronic waste. Traditionally, mechanical and thermal processings have been used to recover copper and plastic from cables. However, these approaches are often energy-intensive, time-consuming, and costly in terms of equipment and labor. In this study, we present a simple and effective method for recovering materials from cable scrap using a domestic microwave oven. Cable pieces (2–2.5 cm long) were exposed to 700 W of microwave irradiation under rotation for 30 s, enabling the rapid and efficient separation of high-quality copper metal from the core wire, and activated carbon from the carbonized plastic sheath. Microwaves facilitate this process through Ohmic heating, which induces electrical resistance in the metal, generating heat that mechanically loosens the metal and carbonized plastic components. The process demonstrates high efficiency, achieving an 80% reduction in energy consumption compared to conventional processings. This fast and energy-efficient method shows strong potential for scaling up to industrial recycling, offering a cost-effective and environmentally friendly way to recover high-quality materials for further use or repurposing.

Bourlinos, Athanasios B. (ORCID:0000000256165993)↗

Assessment of Cementitious Composites for High-Temperature Geothermal Wells

High-temperature (HT) geothermal wells can provide green power 24 hours a day, 7 days a week. Under harsh environmental and operational conditions, the long-term durability requirements of such wells require special cementitious composites for well construction. This paper reports a comprehensive assessment of geothermal cement composites in cyclic pressure function laboratory tests and field exposures in an HT geothermal well (300–350 °C), as well as a numerical model to complement the experimental results. Performances of calcium–aluminate cement (CAC)-based composites and calcium-free cement were compared against the reference ordinary Portland cement (OPC)/silica blend. The stability and degradation of the tested materials were characterized by crystalline composition, thermo-gravimetric and elemental analyses, morphological studies, water-fillable porosity, and mechanical property measurements. All CAC-based formulations outperformed the reference blend both in the function and exposure tests. The reference OPC/silica lost its mechanical properties during the 9-month well exposure through extensive HT carbonation, while the properties of the CAC-based blends improved over that period. The Modified Cam-Clay (MCC) plasticity parameters of several HT cement formulations were extracted from triaxial and Brazilian tests and verified against the experimental results of function cyclic tests. These parameters can be used in well integrity models to predict the field-scale behavior of the cement sheath under geothermal well conditions.

15 GEOTHERMAL ENERGY↗

Pool-Based Tow System for Testing Tethered Hydrokinetic Devices Being Developed to Harvest Energy From Ocean Currents

Abstract The immense potential for ocean current energy harvesting is being actively explored as the push for renewable energy becomes more urgent. This paper demonstrates a tow testing platform built to examine and validate mathematical models related to the performance of tethered, underwater, hydrokinetic devices in development to harvest energy from ocean currents, and presents experimental results illustrating how such a system can be used. The platform has been modularly designed to allow for the testing of various tethered, underwater energy-generation systems, including kite-based systems, coaxial turbines, and duct sails. Previous research on tethered energy-generating systems has primarily been focused on airborne systems. Additionally, the limited experimental research on tethered, underwater energy-generation systems has relied on a rigid rod for mechanical and electrical connections between the test articles and instrumentation. The tow testing platform presented in this paper accomplishes the mechanical and electrical connection through a dual-function tether, featuring internal conductors and an external sheath to support towing loads. The goal of this platform was to enable the emulation of ocean currents, which are largely unidirectional, and to retrofit a regular pool into a cost-effective, adaptable, small-scale tow tank test bed. The capabilities of the system include two-way communication with tethered devices, multiple towing profiles in order to emulate different flow regimes, real-time control, and differential velocities via dual winch operation.

Engineering↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

NCSU RDMA data

NCSU RDMA Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Nano-Scanning Mobility Particle (SMPS); A Radial Differential Mobility Analyzer (RDMA) coupled with 1 Condensation Particle Counter Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU RDMA was operated at a sheath-to-sample flow ratio of 5:1.5 L min−1. The RDMA was configured to scan from 5 to 55 nm. It was located into the temperature-controlled trailer adjacent to the NCSU Flux Tower to observe size distributions of the aerosols.The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

NCSU HTDMA data

NCSU HTDMA data Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument description Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Humidified Tandem Differential Mobility Analyzer; 2 Differential Mobility Analyzers (DMA1 and DMA2). Start Date: 2022-06-01 End Date: 2022-09-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU HTDMA was operated at a sheath-to-sample flow ratio of 5:1 L min−1. The HTDMA was configured to measure hygroscopic growth factors of dry particles with mobility diameters of D = 15, 20, 30, 40, and 50 nm at RH ~ 70%. A complete cycle for all diameters took ~30 minutes. A sample line brought aerosol inside the trailer at 2.5 L min-1, where it was distributed between NCSU RDMA (1.5 L min-1) and NCSU HTDMA (1 L min-1) lines. The sample line was dried with three silica-gel driers in series, and then neutralized with X-ray neutralizer. The sample line entered DMA1 (operated as an electrostatic classifier). Monodisperse particles with certain fractions were humidified with temperature controlled Nafion membrane immersed in water before entering DMA2 (operated in scanning mobility particle sizer). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

CCN Measurements at Urban Site during CoURAGE

Cloud condensation nuclei (CCN) measurements were collected during CoURAGE from March - June 2025 at the BSEC urban atmospheric chemistry supersite (39.32057 N, 76.6246 W). CCN number concentrations (# cm-3) were obtained at a frequency of 1 second using a cloud condensation nuclei counter (CCN-100, Droplet Measurement Technologies). The CCN counter was operated in stepping mode, measuring CCN over a range of supersaturations from 0.2 to 1.0%. The settings of the instrument were set such that the supersaturation increased in increments of 0.2% up to the maximum supersaturation, and then decreased in increments of 0.2% down to the minimum supersaturation in a repeating cycle. The supersaturation of the instrument was calibrated weekly using ammonium sulfate. The weekly calibrated supersaturation values have been applied to the data. Data during transitions between supersaturation values were removed and replaced with a value of -999. Transitions are defined as the first 210 seconds after a new supersaturation value to ensure the instrument has stabilized following a change in supersaturation. Data were also flagged with a value of -999 if there were concerns with the function of the instrument, specifically the presence of alarm codes, fogging of the optical particle counter (1st stage monitor > 0.4 V), or a sheath to sample flow ratio outside the expected range (< 9 or > 11).

CCN number density↗

Simulations of divertor heat flux width using transport code with cross-field drifts under the BOUT++ framework

The fluid transport code [trans-electric field (Er) module] under the BOUT++ framework has been used to simulatedivertor heat flux width and boundary Er with all drifts and the sheath potential in the scrape-off layer. The calculated steady state radial Er in the pedestal region has been compared with that of experimental measurements from the Alcator C-Mod tokamak. The magnitude and shape of Er are similar to those of the experimental data. In order to understand the relative role of cross-field drifts vs turbulent transport in setting the heat flux width, four C-Mod enhanced Dα H-mode discharges with a lower single null divertor configuration should be simulated. BOUT++ transport simulations with cross-field drifts included yield similar heat flux width λq to that of experimental measurements (within a factor of 2) from both the probe and the surface thermocouple diagnostics and show a similar trend with plasma current to that of the Eich experimental scaling. The simulations show that both drifts and turbulent transport compete to determine the heat flux width. The magnetic drifts play a dominant role in setting the divertor heat-flux width, while the E × B drift decreases the heat flux width by 10%–25%, leading to improved agreement with the experiment relative to Goldston’s model. A turbulence diffusivity scan (χ) identifies two distinct regimes: a drift dominant regime when χ is small and a turbulence dominant regime when χ is large. The Goldston heuristic drift model yields a lower limit of the width λq.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE VLF ADMITTANCE OF A DIPOLE IN THE LOWER IONOSPHERE

The admittance of a dipole in the lower ionosphere has been calculated for very low frequencies. Both the real and reactive parts of the admittance are found to be related to the ion sheath which forms about the dipole and are functions of electron density and temperature of the ionosphere. An electron density profile is estimated based upon measurements reported in an earlier rocket flight.

DIPOLE↗

Connector for thermocouple leads saves costly wire, makes reliable connectors

A connector for use in the thermocouple circuits which is silver-brazed to the metal thermocouple sheath on one end and crimped over the insulation of the flexible lead on the other, assures protection against breakage and abrasion. A moisture-proof insulating material is used to encapsulate the wire junctions.

Miller, H. B.↗

THE V. L. F. ADMITTANCE OF A DIPOLE IN THE LOWER IONOSPHERE

The admittance of a dipole in the lower ionosphere has been calculated for very low frequencies. Both the real and reactive parts of the admittance are found to be related to the ion sheath which forms about the dipole and are functions of electron density and temperature of the ionosphere. An electron density profile is estimated based upon measurement reported in an earlier rocket flight.

DIPOLE↗

Plasma.

Plasma physics and engineering applications noting sheath or Debye length, Hall effect, magnetic field technology and reflectivity conductivity

PLASMA PHYSICS↗

Improved atmospheric particle analyzer

Nephelometer measures aerosol particles in wide concentration and size distribution ranges. It measures the light scattered from the aerosol particles at a controlled sampling rate to ensure laminar flow through the sample tube, and thereby eliminate the need for sheath air.

Source record↗