Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Wavelength-independent constant period spin-echo modulated small angle neutron scattering

Spin-Echo Modulated Small Angle Neutron Scattering (SEMSANS) in Time-of-Flight (ToF) mode has been shown to be a promising technique for measuring (very) small angle neutron scattering (SANS) signals and performing quantitative Dark-Field Imaging (DFI), i.e., SANS with 2D spatial resolution. However, the wavelength dependence of the modulation period in the ToF spin-echo mode has so far limited the useful modulation periods to those resolvable with the limited spatial resolution of the detectors available. Here we present our results of an approach to keep the period of the induced modulation constant for the wavelengths utilised in ToF. This is achieved by ramping the magnetic fields in the coils responsible for creating the spatially modulated beam in synchronisation with the neutron pulse, thus keeping the modulation period constant for all wavelengths. Such a setup enables the decoupling of the spatial detector resolution from the resolution of the modulation period by the use of slits or gratings in analogy to the approach in grating-based neutron DFI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of electron cyclotron emission imaging system on the HL-2A tokamak

A 2D electron cyclotron emission imaging (ECEI) system has been developed for measurement of electron temperature fluctuations in the HL-2A tokamak. It is comprised of a front-end 24 channel heterodyne imaging array with a tunable RF range spanning 75–110 GHz, and a set of back-end ECEI electronics that together generate 24 × 8 = 192 channel images of the 2nd harmonic X-mode electron cyclotron emission from the HL-2A plasma. The simulated performance of the local oscillator (LO) optics and radio frequency (RF) optics is presented, together with the laboratory characterization results. The Gaussian beams from the LO optics are observed to properly cover the entire detector array. The ECE signals from the plasma are mixed with the LO signal in the array box, then delivered to the electronics system by low-loss microwave cables, and finally to the digitizers. The ECEI system can achieve temporal resolutions of ∼μs, and spatial resolutions of 1 cm (radially) and 2 cm (poloidally)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-26: Analysis of Image Quality in CBCT QA Using a Treatment Planning System

Purpose: The objective of this study is to propose an alternative QA technique that analyzes imaging quality(IQ) in CBCT-QA processing. Methods: A catphan phantom was used to take CT imaging data set that were imported into a treatment planning system - Eclipse. The image quality was analyzed in terms of in-slice geometry resolution, Hounsfield numbers(HU) accuracy, mean-slice thickness, edge-to-center uniformity, low contrast resolution, and high contrast spatial resolution in Eclipse workstation. The CBCT-QA was also analyzed by OBI-workstation and a commercial software. Comparison was made to evaluation feasibility in a TPS environment. Results: The analysis of IQ was conducted in Eclipse v10.0 TPS. In-slice geometric resolution was measured between 2-rods in section CTP404 and repeated for all 4 rods with the difference between expected and measured values less than +/−0.1 cm. For HU, the difference between expected and measured values in HU was found much less than +/−40. Mean slice thickness measured by a distance on the wire proportional to scanner increment multiplying by a factor of 0.42. After repeating measurements to 4 wires, the average difference between expected and measured values was less +/−0.124 mm in slice thickness. HU uniformity was measured in section CTP486 with the tolerance less than +/−40 HU. Low contrast resolution in section CTP515 and high contrast resolution in section CTP528 were found to be 7 disks in diameter of 4 mm and 6 lp/cm, respectively. Eclipse TPS results indicated a good agreement to those obtained in OBI workstation and ImagePro software for major parameters. Conclusion: An analysis of IQ was proposed as an alternative CBCT QA processing. Based upon measured data assessment, proposed method was accurate and consistent to IQ evaluation and TG142 guideline. The approach was to utilize TPS resource, which can be valuable to re-planning, verification, and delivery in adaptive therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron spectroscopy as a fuel ion ratio diagnostic: Lessons from JET and prospects for ITER

The determination of the fuel ion ratio n{sub t}/n{sub d} in ITER is required at a precision of 20%, time resolution of 100 ms, spatial resolution of a/10, and over a range of 0.01 6 keV and for n{sub T}/n{sub D}<0.6. A crucial issue is the signal-to-background situation in the measurement of the weak 2.5 MeV emission from DD reactions in the presence of a background of scattered 14 MeV DT neutrons. Important experimental input and corroboration for this assessment are presented from the time-of-flight neutron spectrometer at JET where the presence of a strong component of backscattered neutrons is observed. Neutron emission components on ITER due to beam-thermal and tritium-tritium reactions can further enhance the prospects for NES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational studies of x-ray scattering from three-dimensionally-aligned asymmetric-top molecules

We theoretically and numerically analyze x-ray scattering from asymmetric-top molecules three-dimensionally aligned using elliptically polarized laser light. A rigid-rotor model is assumed. The principal axes of the polarizability tensor are assumed to coincide with the principal axes of the moment of inertia tensor. Several symmetries in the Hamiltonian are identified and exploited to enhance the efficiency of solving the time-dependent Schroedinger equation for each rotational state initially populated in a thermal ensemble. Using a phase-retrieval algorithm, the feasibility of structure reconstruction from a quasiadiabatically aligned sample is illustrated for the organic molecule naphthalene. The spatial resolution achievable strongly depends on the laser parameters, the initial rotational temperature, and the x-ray pulse duration. We demonstrate that for a laser peak intensity of 5 TW/cm{sup 2}, a laser pulse duration of 100 ps, a rotational temperature of 10 mK, and an x-ray pulse duration of 1 ps, the molecular structure may be probed at a resolution of 1 A ring .

74 ATOMIC AND MOLECULAR PHYSICS↗

High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak (invited)

A high-performance Faraday-effect polarimeter-interferometer system has been developed for the J-TEXT tokamak. This system has time response up to 1 μs, phase resolution < 0.1° and minimum spatial resolution ∼15 mm. High resolution permits investigation of fast equilibrium dynamics as well as magnetic and density perturbations associated with intrinsic Magneto-Hydro-Dynamic (MHD) instabilities and external coil-induced Resonant Magnetic Perturbations (RMP). The 3-wave technique, in which the line-integrated Faraday angle and electron density are measured simultaneously by three laser beams with specific polarizations and frequency offsets, is used. In order to achieve optimum resolution, three frequency-stabilized HCOOH lasers (694 GHz, >35 mW per cavity) and sensitive Planar Schottky Diode mixers are used, providing stable intermediate-frequency signals (0.5–3 MHz) with S/N > 50. The collinear R- and L-wave probe beams, which propagate through the plasma poloidal cross section (a = 0.25–0.27 m) vertically, are expanded using parabolic mirrors to cover the entire plasma column. Sources of systematic errors, e.g., stemming from mechanical vibration, beam non-collinearity, and beam polarization distortion are individually examined and minimized to ensure measurement accuracy. Simultaneous density and Faraday measurements have been successfully achieved for 14 chords. Based on measurements, temporal evolution of safety factor profile, current density profile, and electron density profile are resolved. Core magnetic and density perturbations associated with MHD tearing instabilities are clearly detected. Effects of non-axisymmetric 3D RMP in ohmically heated plasmas are directly observed by polarimetry for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEBULAR AND STELLAR DUST EXTINCTION ACROSS THE DISK OF EMISSION-LINE GALAXIES ON KILOPARSEC SCALES

We investigate the resolved kiloparsec-scale stellar and nebular dust distribution in eight star-forming galaxies at z ∼ 0.4 in the Great Observatories Origins Deep Survey fields. This is to get a better understanding of the effect of dust attenuation on measurements of physical properties and its variation with redshift. Constructing the observed spectral energy distributions (SEDs) per pixel, based on seven bands of photometric data from Hubble Space Telescope/Advanced Camera for Surveys and WFC3, we performed pixel-by-pixel SED fits to population synthesis models and estimated the small-scale distribution of stellar dust extinction. We use Hα/Hβ nebular emission line ratios from Keck/DEIMOS high-resolution spectra at each spatial resolution element to measure the amount of attenuation faced by ionized gas at different radii from the centers of galaxies. We find a good agreement between the integrated and median of resolved color excess measurements in our galaxies. The ratio of integrated nebular to stellar dust extinction is always greater than unity, but does not show any trend with stellar mass or star formation rate (SFR). We find that inclination plays an important role in the variation of the nebular to stellar excess ratio. The stellar color excess profiles are found to have higher values at the center compared to outer parts of the disk. However, for lower mass galaxies, a similar trend is not found for the nebular color excess. We find that the nebular color excess increases with stellar mass surface density. This explains the absence of radial trend in the nebular color excess in lower mass galaxies which lack a large radial variation of stellar mass surface density. Using standard conversions of SFR surface density to gas mass surface density, and the relation between dust mass surface density and color excess, we find no significant variation in the dust-to-gas ratio in regions with high gas mass surface densities over the scales probed in this study.

79 ASTRONOMY AND ASTROPHYSICS↗

HiRes deconvolved Spitzer images of 89 protostellar jets and outflows: New data on the evolution of the outflow morphology

To study the role of protosellar jets and outflows in the time evolution of the parent cores and the protostars, the astronomical community needs a large enough database of infrared images of protostars at the highest spatial resolution possible to reveal the details of their morphology. Spitzer provides unprecedented sensitivity in the infrared to study both the jet and outflow features, however, its spatial resolution is limited by its 0.85 m mirror. Here, we use a high-resolution deconvolution algorithm, 'HiRes,' to improve the visualization of spatial morphology by enhancing resolution (to subarcsecond levels in the IRAC bands) and removing the contaminating side lobes from bright sources in a sample of 89 protostellar objects. These reprocessed images are useful for detecting (1) wide-angle outflows seen in scattered light, (2) morphological details of H{sub 2} emission in jets and bow shocks, and (3) compact features in MIPS 24 μm images as protostar/disk and atomic/ionic line emission associated with the jets. The HiRes FITS image data of such a large homogeneous sample presented here will be useful to the community in studying these protostellar objects. To illustrate the utility of this HiRes sample, we show how the opening angle of the wide-angle outflows in 31 sources, all observed in the HiRes-processed Spitzer images, correlates with age. Our data suggest a power-law fit to opening angle versus age with an exponent of ∼0.32 and 0.02, respectively, for ages ≤8000 yr and ≥8000 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Detector design for high-resolution MeV photon imaging of cargo containers using spectral information

Monte Carlo simulations of a pixelated detector array of inorganic scintillators for high spatial resolution imaging of 1-9 MeV photons are presented. The results suggest that a detector array of 0.5 cm x 0.5 cm x 5 cm pixels of bismuth germanate may provide sufficient efficiency and spatial resolution to permit imaging of an object with uncertainties in dimension of several mm. The cross talk between pixels is found to be in the range of a few percent when pixels are shielded by {approx} 1mm of lead or tungsten. The contrast at the edge of an object is greatly improved by rejection of events depositing less than {approx} 1 MeV. Given the relatively short decay time of BGO, the simulations suggest that such a detector may prove adequate for the purpose of rapid scanning of highly-shielded cargos for possible presence of high atomic number (including clandestine fissionable) materials when used with low current high duty factor x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of multimesh hp-FEM to interpolation and projection methods for spatial coupling of thermal and neutron diffusion calculations

Multiphysics solution challenges are legion within the field of nuclear reactor design and analysis. One major issue concerns the coupling between heat and neutron flow (neutronics) within the reactor assembly. These phenomena are usually very tightly interdependent, as large amounts of heat are quickly produced with an increase in fission events within the fuel, which raises the temperature that affects the neutron cross section of the fuel. Furthermore, there typically is a large diversity of time and spatial scales between mathematical models of heat and neutronics. Indeed, the different spatial resolution requirements often lead to the use of very different meshes for the two phenomena. As the equations are coupled, one must take care in exchanging solution data between them, or significant error can be introduced into the coupled problem. We propose a novel approach to the discretization of the coupled problem on different meshes based on an adaptive multimesh higher-order finite element method (hp-FEM), and compare it to popular interpolation and projection methods. We show that the multimesh hp-FEM method is significantly more accurate than the interpolation and projection approaches considered in this study.

97 MATHEMATICS AND COMPUTING↗

Investigation of the Distribution of Elements in Snail Shell With the use of Synchrotron-Based, Micro-Beam X-ray Fluorescence Spectrometry

In this study, synchrotron-based micro-beam was utilized for elemental mapping of a small animal shell. A thin X-ray spot of the order of {approx}10 em was focused on the sample. With this spatial resolution and high flux throughput, the X-ray fluorescent intensities for Ca, Mn, Fe, Ni, Zn, Cr and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive HpGe detector. The sample is scanned in a estep-and-repeat' mode for fast elemental mapping and generated elemental maps at 8, 10 and 12 keV. All images are of 10 em resolution and the measurement time was 1 s per point. The accumulation of trace elements was investigated from the soft-tissue in small areas. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other trace elements.

59 BASIC BIOLOGICAL SCIENCES↗

Atomic-scale characterization of (electro-)catalysts and battery materials by atom probe tomography

To optimise the performance of heterogeneous (electro-)catalysts and battery electrodes, it is essential to establish the structure-property relationships. This can only be achieved by obtaining a full three-dimensional (3D) characterisation of atomic-scale structure and chemistry of these advanced materials. Atom probe tomography (APT) can provide unique insights into 3D elemental distribution, including low atomic mass elements, with sub-nanometer spatial resolution. Despite its superior chemical analytical capability and spatial resolution, APT has limited applications for sustainable energy materials due to technical and analytical challenges. The recent developments in experimental setups, sample preparation methods and data analysis algorithms have opened the door to the possibility of analysing heterogeneous (electro-)catalysts and battery electrodes. This perspective provides an overview of these developments, exemplified by recent achievements of analyzing model heterogeneous model (electro-)catalysts, nanoparticles, zeolites, MOFs and Li-ion battery electrodes, followed by a discussion of limitations, opportunities, and potentials of APT for future scientific exploration.

atom probe tomography↗

Polymer/carbon nanotube composite patterns via laser induced forward transfer

Direct and high spatial resolution printing of polymer/carbon nanotube (CNT) composite layers has been demonstrated by means of laser induced forward transfer (LIFT). Laser irradiation of composite target materials, such as poly(acrylic acid)/CNT and polyvinylpyrrolidone/CNT, enabled dry deposition of well resolved composite pixels onto glass substrates. The dispersion of the CNT into the deposited composite pixels was investigated by transmission electron microscopy. The LIFT technique was also employed for the accurate deposition of polymer/CNT composite pixels onto aluminum microelectrodes for the fabrication of chemical sensors based on polymer/CNT compounds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nanoscopium: a Scanning Hard X-ray Nanoprobe Beamline at Synchrotron Soleil

Nanoscopium is the single scanning hard X-ray nano-probe beamline planned at SOLEIL. This {approx}155 m long beamline will fully exploit the high brilliance and coherence characteristics of the X-ray beam both for diffraction limited focusing and for contrast formation. It will offer the most advanced imaging techniques in multimodal mode and will be a research tool for a wide user community working in the fields of earth-, environmental-, and life-sciences. The different {mu}-{mu}nano-probe techniques offered by the beamline will permit elemental mapping at trace (ppm) levels (scanning XRF), speciation mapping (XANES), phase gradient mapping (scanning differential phase contrast), and density-contrast based imaging of internal structures (coherent diffraction imaging) in the 30 nm to 1 {mu}m spatial resolution range, also in ''in situ conditions''. Nanoscopium will cover the 5-20 keV energy range. The stability of the nanobeam will be ensured by horizontally reflecting beamline optics (a sagitally and a tangentially pre-focusing mirror, horizontally reflecting monochromators) in front of the overfilled secondary source. Trade-off between high energy resolution ({Delta}E/E{approx}10{sup -4}) and high flux (10{sup 11} ph/s with {Delta}E/E{approx}10{sup -2}) will be achieved by two interchangeable monochromators (a double crystal and a double multilayer one). KB mirror and FZP lenses will be used as focusing devices. The beamline is in the design and construction phase. It is foreseen to be open for users at the beginning of 2013.

43 PARTICLE ACCELERATORS↗

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real Time Tomography at the Swiss Light Source

The penetrating power of X-rays coupled with the high flux of 3rd generation synchrotron sources makes X-ray tomography to excel among fast imaging methods . To exploit this asset of synchrotron sources is the motivation for setting up an ultra-fast tomography endstation at the TOMCAT beamline. The state of the art instruments at synchrotron sources offer routinely a temporal resolution of tens of seconds in tomography. For a number of applications, for example biomedical studies, the relevant time scales (breathing, heartbeat) are rather in the range of 0.5-2 seconds. To overcome motion artifacts when imaging such systems a new ultra-fast tomographic data acquisition scheme is being developed at the TOMCAT beamline. We can acquire a full set of projections at sub-second timescale in monochromatic or white-beam configuration. We present a feasibility study with the ultimate aim to achieve sub-second temporal resolution in 3D without significant deterioration of the spatial resolution. For the first time, the 3D dynamics of the very early stages of a quickly aging liquid foam can be visualised with high quality and sufficiently large field of view.

43 PARTICLE ACCELERATORS↗

Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT

This article illustrates the phase contrast instrumentation installed at the Tomographic Microscopy and Coherent Radiology beamline (TOMCAT) of the Swiss Light Source. Our experimental framework has been designed to extract phase information at spatial resolutions covering three orders of magnitude. For moderate (5-10 microns) resolutions we implemented a two-gratings interferometer, operated at energies between 14 and 40 keV. For high resolution (1-5 microns) we obtain phase information thanks to a modified transport of intensity approach. For very high-resolutions (0.1-0.5 microns) we developed a broadband hard X-ray full-field microscope operated in Zernike-phase contrast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring the electron density gradients of dense plasmas by deflectometry using short-wavelength probe

A new and simple experimental technique for the measurement of electron density gradients in dense laser-produced plasmas using an electromagnetic wave probe is presented. The main advantage of this method is the low requirements on coherence of the probing beam. The method is based on measuring the deformation of the Talbot pattern of a two-dimensional grating that stems from the distortion of the probe beam wave-front caused by the gradients of the index of refraction. The compromise between spatial resolution and sensitivity for the given wavelength of the probe beam is set by the experimental design. The proposed technique was experimentally verified on plasmas that were created by either a point focus or a line focus of a laser interacting with various solid targets. In the experiments reported here, all plasmas were probed by a Ne-like Zn x-ray laser beam at 21.2 nm, but the technique is applicable for any wavelength of the probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗