Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Temperature and electric field control of the bandgap in electrotoroidic nanocomposites by large-scale ab initio methods

An effective Hamiltonian scheme combined with a GPU implementation of the linear-scaling three-dimensional fragment (LS3DF) method is used to compute electronic properties of two topological objects in a nanocomposite: an electrical vortex coexisting with spontaneous electrical polarization over a wide temperature range and an electrical skyrmion over a range of applied electric fields. Temperature control of the vortex provides substantially larger range of control of bandgap and band alignment than field control of the skyrmion. Using temperature and electric fields to manipulate polarization and bond angle distortion in different component materials provides a handle for bandgap engineering in such nanostructures.

Materials Science↗

Simultaneous Independent Control of Tool Axial Force and Temperature in Friction Stir Processing

Maintaining consistent tool depth relative to the part surface is a critical requirement for many Friction stir processing (FSP) applications. Force control is often used with the goal of obtaining a constant weld depth. When force control is used, if weld temperature decreases, flow stress increases and the tool is pushed up. If weld temperature increases, flow stress decreases and the tool dives. These variations in tool depth and weld temperature cause various types of weld defects. Robust temperature control for FSP maintains a commanded temperature through control of the spindle axis only. Robust temperature control and force control are completely decoupled in control logic and machine motion. This results in stable temperature, force and tool depth despite the presence of geometric and thermal disturbances. Performance of this control method is presented for various weld paths and alloy systems.

force control↗

Temperature as a control knob on spin-orbit coupling

Spin-orbit coupling (SOC) governs many physical phenomena. Through ab initio molecular dynamics simulations, Lu and Sun demonstrated that structural disorder at elevated temperatures substantially reduces the effective SOC contribution that stabilizes band inversion, driving a topological-to-normal-insulator transition in Bi2Se3. Their work identifies temperature as a meaningful control parameter for SOC-mediated topology and other properties.

Liang, Liangbo [ORNL] (ORCID:0000000311990049)↗

Ultrafast Electric Field Pulse Control of Giant Temperature Change in Ferroelectrics

There is a surge of interest in developing environmentally friendly solid-state-based cooling technology. Here, we point out that a fast cooling rate (≈ 10 11 K/s) can be achieved by driving solid crystals to a high-temperature phase with a properly designed electric field pulse. Specifically, we predict that an ultrafast electric field pulse can cause a giant temperature decrease up to 32 K in PbTiO 3 occurring on few picosecond time scales. Here, we explain the underlying physics of this giant electric field pulse-induced temperature change with the concept of internal energy redistribution: the electric field does work on a ferroelectric crystal and redistributes its internal energy, and the way the kinetic energy is redistributed determines the temperature change and strongly depends on the electric field temporal profile. This concept is supported by our all-atom molecular dynamics simulations of PbTiO 3 and BaTiO 3 . Moreover, this internal energy redistribution concept can also be applied to understand electrocaloric effect. We further propose new strategies for inducing giant cooling effect with ultrafast electric field pulse. This Letter offers a general framework to understand electric-field-induced temperature change and highlights the opportunities of electric field engineering for controlled design of fast and efficient cooling technology.

36 MATERIALS SCIENCE↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

Energy savings with outdoor temperature-based smart ventilation control strategies in advanced California homes

We simulated the energy performance of smart ventilation controls based on outdoor temperature in homes located in California climate regions, designed to comply with the 2016 Title 24, Part 6 California Energy Code prescriptive requirements. The smart controls shift ventilation rates in time, but ensure an annual occupant pollutant exposure equal to, or less than, what would be experienced in a home with a constant ventilation rate equal to the whole house target airflow in the ASHRAE Standard 62.2-2016. Annual simulations of previously developed prototype homes with validated ventilation models were conducted via co-simulation of EnergyPlus with CONTAM. Controller performance varied substantially by climate zone, airtightness and house prototype. Smart controls were generally ineffective in Climate Zone 1 (Arcata) due to its lack of a cooling season and low diurnal temperature swings. The most successful smart controls used parameters pre-calculated using an optimization routine. In order to better inform state energy policy, we also determined savings weighted by the amount of new home construction in each climate. The best controls averaged about one-third of ventilation-related energy savings that increased to about 48–55% when weighted. Annual average savings were about 650–700 kWh/year for the best controllers. The vast majority of site energy savings were for heating end-uses (>90% of total savings). Whole house ventilation rates increased between 0% and 42%, with typical increases in the 15–20% range. Finally, the best-performing control strategies shifted ventilation rates seasonally and modulated flows within each season. Peak concentrations during low ventilation times were kept below an exposure level of 3, well below the maximum of 5 required to avoid acute exposure issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of growth temperature on composition control for vapor deposition of YBa{sub 2}Cu{sub 3}O{sub 7−δ} precursor films

This work aims at exploiting the role of growth temperature on the dynamic behavior of deposition atoms as well as its resultant impact on the composition control during the synthesis of YBa{sub 2}Cu{sub 3}O{sub 7−δ} precursor films by vapor codeposition. The codeposition of Yt, BaF{sub 2} and Cu is performed in vacuum chamber under a wide range of growth temperature from 25°C to 600°C, the mass of each element deposited on LaAlO{sub 3} substrate and thus the film composition is examined by the inductively coupled plasma atomic emission spectroscopy. It is shown that the deposition amount of Cu decreases obviously with the increase of growth temperature; however, the mass of Yt and BaF{sub 2} deposited on the substrate appears to be insensitive to growth temperature. Moreover, high temperature may also trigger the influence of adsorbates composition on Cu desorption, and therefore the deposition amount of Cu decreases almost linearly as the mol fraction of BaF{sub 2} in the adlayers increases. Nevertheless, when the deposition is conducted at room temperature, the influence of mol fraction of BaF{sub 2} on Cu desorption vanishes. The detailed mechanisms associated with above phenomena are unveiled by molecular dynamics analysis, additionally the physical picture about adsorption behaviors on the growing interface under different deposition conditions is summarized, which is valuable for handling the composition control during the vapor codeposition of different functional films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust isothermal electric control of exchange bias at room temperature

Voltage-controlled spin electronics is crucial for continued progress in information technology. It aims at reduced power consumption, increased integration density and enhanced functionality where non-volatile memory is combined with high-speed logical processing. Promising spintronic device concepts use the electric control of interface and surface magnetization. From the combination of magnetometry, spin-polarized photoemission spectroscopy, symmetry arguments and first-principles calculations, we show that the (0001) surface of magnetoelectric Cr{sub 2}O{sub 3} has a roughness-insensitive, electrically switchable magnetization. Using a ferromagnetic Pd/Co multilayer deposited on the (0001) surface of a Cr{sub 2}O{sub 3} single crystal, we achieve reversible, room-temperature isothermal switching of the exchange-bias field between positive and negative values by reversing the electric field while maintaining a permanent magnetic field. This effect reflects the switching of the bulk antiferromagnetic domain state and the interface magnetization coupled to it. The switchable exchange bias sets in exactly at the bulk Neel temperature.

36 MATERIALS SCIENCE↗

Reconfigurable Vanadium Dioxide Nanomembranes and Microtubes with Controllable Phase Transition Temperatures

Here, two additional structural forms, free-standing nanomembranes and microtubes, are reported and added to the vanadium dioxide (VO 2 ) material family. Free-standing VO 2 nanomembranes were fabricated by precisely thinning as-grown VO 2 thin films and etching away the sacrificial layer underneath. VO 2 microtubes with a range of controllable diameters were rolled-up from the VO 2 nanomembranes. When a VO 2 nanomembrane is rolled-up into a microtubular structure, a significant compressive strain is generated and accommodated therein, which decreases the phase transition temperature of the VO 2 material. The magnitude of the compressive strain is determined by the curvature of the VO 2 microtube, which can be rationally and accurately designed by controlling the tube diameter during the rolling-up fabrication process. The VO 2 microtube rolling-up process presents a novel way to controllably tune the phase transition temperature of VO 2 materials over a wide range toward practical applications. Furthermore, the rolling-up process is reversible. A VO 2 microtube can be transformed back into a nanomembrane by introducing an external strain. Because of its tunable phase transition temperature and reversible shape transformation, the VO 2 nanomembrane-microtube structure is promising for device applications. As an example application, a tubular microactuator device with low driving energy but large displacement is demonstrated at various triggering temperatures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Reaction temperature sensing (RTS)-based control for Li-ion battery safety

We report reaction temperature sensing (RTS)-based control to fundamentally enhance Li-ion battery safety. RTS placed at the electrochemical interface inside a Li-ion cell is shown to detect temperature rise much faster and more accurately than external measurement of cell surface temperature. We demonstrate, for the first time, that RTS-based control shuts down a dangerous short-circuit event 3 times earlier than surface temperature- based control and prevents cell overheating by 50 °C and the resultant cell damage.

25 ENERGY STORAGE↗

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

Localized Control of Curie Temperature in Perovskite Oxide Film by Capping-Layer-Induced Octahedral Distortion

With reduced dimensionality, it is often easier to modify the properties of ultrathin films than their bulk counterparts. Strain engineering, usually achieved by choosing appropriate substrates, has been proven effective in controlling the properties of perovskite oxide films. An emerging alternative route for developing new multifunctional perovskite is by modification of the oxygen octahedral structure. Here we report the control of structural oxygen octahedral rotation in ultrathin perovskite SrRuO 3 films by the deposition of a SrTiO 3 capping layer, which can be lithographically patterned to achieve local control. Here, using a scanning Sagnac magnetic microscope, we show an increase in the Curie temperature of SrRuO 3 due to the suppression octahedral rotations revealed by the synchrotron x-ray diffraction. Lastly, this capping-layer-based technique may open new possibilities for developing functional oxide materials.

36 MATERIALS SCIENCE↗

Unfolding of a Temperature-Sensitive Domain Controls Voltage-Gated Channel Activation

Voltage-gated ion channels (VGICs) are outfitted with diverse cytoplasmic domains that impact function. To examine how such elements may affect VGIC behavior, we addressed how the bacterial voltage-gated sodium channel (BacNa V ) C-terminal cytoplasmic domain (CTD) affects function. Our studies show that the BacNa V CTD exerts a profound influence on gating through a temperature-dependent unfolding transition in a discrete cytoplasmic domain, the neck domain, proximal to the pore. Structural and functional studies establish that the BacNa V CTD comprises a bi-partite four-helix bundle that bears an unusual hydrophilic core whose integrity is central to the unfolding mechanism and that couples directly to the channel activation gate. Altogether, our findings define a general principle for how the widespread four-helix bundle cytoplasmic domain architecture can control VGIC responses, uncover a mechanism underlying the diverse BacNa V voltage dependencies, and demonstrate that a discrete domain can encode the temperature-dependent response of a channel.

59 BASIC BIOLOGICAL SCIENCES↗

Experimentally-determined characteristics of radiant systems for office buildings

Radiant heating and cooling systems have significant energy-saving potential and are gaining popularity in commercial buildings. The main aim of the experimental study reported here was to characterize the behavior of radiant cooling systems in a typical office environment, including the effect of ceiling fans on stratification, the variation in comfort conditions from perimeter to core, control on operative temperature vs. air temperature and the effect of carpet on cooling capacity. The goal was to limit both the first cost and the perceived risk associated with such systems. Two types of radiant systems, the radiant ceiling panel (RCP) system and the radiant slab (RS) system, were investigated. The experiments were carried out in one of the test cells that constitute the FLEXLAB test facility at the Lawrence Berkeley National Laboratory in March and April 2016. In total, ten test cases (five for RCP and five for RS) were performed, covering a range of operational conditions. In cooling mode, the air temperature stratification is relatively small in the RCP, with a maximum value of 1.6 K. The observed stratification effect was significantly greater in the RS, twice as much as that in the RCP. The maximum increase in dry bulb temperature in the perimeter zone due to solar radiation was 1.2 K for RCP and 0.9 K for RS – too small to have a significant impact on thermal comfort. The use of ceiling fans was able to reduce any excess stratification and provide better indoor comfort, if required. The use of thin carpet requires a 1 K lower supply chilled water temperature to compensate for the added thermal resistance, somewhat reducing the opportunities for water-side free cooling and increasing the risk of condensation. In both systems, the difference between the room operative temperature and the room air temperature is small when the cooling loads are met by the radiant systems. In conclusion, this makes it possible to use the air temperature to control the radiant systems in lieu of the operative temperature, reducing both first cost and maintenance costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morphology of U 3 O 8 materials following storage under controlled conditions of temperature and relative humidity

Changes in the visual characteristics of uranium oxide surfaces and morphology following storage under different conditions of temperature and relative humidity may provide insight into the history of an unknown sample. Sub-samples of three α-U 3 O 8 materials—one that was phase-pure and two that were phase-impure—were stored under controlled conditions for two years. We used scanning electron microscopy to image the oxides before and after storage, and a morphology lexicon was used to characterize the images. Finally, temporal changes in morphology were observed in some sub-samples, and changes were greatest following exposure to high relative humidity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Power consumption monitoring using additional monitoring device

Today, emphasis is placed on reducing power consumption. Computers are large consumers; therefore it is important to know the total consumption of computing systems. Since their optimal functioning requires quite strict environmental conditions, without much variation in temperature and humidity, reducing energy consumption cannot be made without monitoring environmental parameters. Thus, the present work uses a multifunctional electric meter UPT 210 for power consumption monitoring. Two applications were developed: software which carries meter readings provided by electronic and programming facilitates remote device and a device for temperature monitoring and control. Following temperature variations that occur both in the cooling system, as well as the ambient, can reduce energy consumption. For this purpose, some air conditioning units or some computers are stopped in different time slots. These intervals were set so that the economy is high, but the work's Datacenter is not disturbed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗