Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Temperature compensated current sensor using reference magnetic field

A method is described to provide temperature compensation and self-calibration of a current sensor based on a plurality of magnetic field sensors positioned around a current carrying conductor. A reference magnetic field generated within the current sensor housing is detected by a separate but identical magnetic field sensor and is used to correct variations in the output signal due to temperature variations and aging.

47 OTHER INSTRUMENTATION↗

Hourly temperature and surface water level at the Ikpikpuk delta from 5/2012 to 11/2012

This data package includes the soil temperature and surface water level observations in 2012 at the Ikpikpuk River delta in northern Alaska. The data file consists of the observation table with both the .xlsx and .csv file formats. The files can be accessed through several software tools, like Microsoft Excel, and text editors. This is raw data from the near-surface ground temperature sensors at 15 cm (active layer) and 100 cm (permafrost) soil depth and a surface water sensor at the Ikpikpuk delta site in Alaska, US. The Ikpikpuk River delta is located on the Arctic Coastal Plain of northern Alaska. The Ikpikpuk River drains a land area of 15,330 km2, emptying into Smith Bay, and the delta is fan-shaped with an aerial extent of 106 km2 (Fuchs et al., 2018). This dataset supports the publication entitled "The thermal response of permafrost to coastal floodplain flooding" submitted to Environmental Research Letters (under review), where the observed water level is used as the upper boundary condition for the model simulations and the observed subsurface temperature is compared with the model simulations to answer the question about how coastal flooding affects permafrost thaw.

54 ENVIRONMENTAL SCIENCES↗

PreSens Dissolved Oxygen and Temperature Data, Old Woman Creek National Estuarine Research Reserve, Huron, OH, 2022-07-06 to 2023-12-15

This dataset contains collected dissolved oxygen (DO) and temperature measurements of the air, surface water, and underlying soil of a wetland at Old Woman Creek Estuarine Research Reserve in Huron, OH. Dissolved oxygen and temperature measurements were made in the first few centimeters of wetland sediment to assess how oxygen profiles changed over time with hydrological events. Measurements taken outside of the sediment were taken as comparison. Measurements were taken by hand with a PreSens Fibox 4 transmitter, paired with an oxygen dipping probe and temperature sensor, at each field outing. Measurements were taken approximately every 2 weeks around 10 AM EST. The PreSens_DO_Temp_Datafile.csv contains the recorded measurements, and the PreSens_InstallationMethods.csv describes the deployment of the sensor.

54 ENVIRONMENTAL SCIENCES↗

Insights on seasonal solifluction processes in warm permafrost Arctic landscape using a dense monitoring approach across adjacent hillslopes

Solifluction processes in the Arctic are highly complex, introducing uncertainties in estimating current and future soil carbon storage and fluxes, and assessment of hillslope and infrastructure stability. This study aims to enhance our understanding of triggers and drivers of soil movement of permafrost-affected hillslopes in the Arctic. To achieve this, we established an extensive soil deformation and temperature sensor network, covering 48 locations across multiple hillslopes within a 1 km² watershed on the Seward Peninsula, AK. We report depth-resolved measurements down to 1.8 m depth for May to September 2022, a period conducive to soil movement due to deepening thaw layers and frequent rain events. Over this period, surface movements of up to 334 mm were recorded. In general, these movements occur close to the thawing front, and are initiated as thawing reaches depths of 0.4 to 0.75 m. The largest movements were observed at the top of the south-east facing slope, where soil temperatures are cold (mean annual soil temperatures averaging -1.13°C) and slopes are steeper than 15°. Our analysis highlights three primary factors influencing movements: slope angle, soil thermal conditions, and thaw depth. The latter two significantly impact the generation of pore water pressures at the thaw–freeze interface. Specifically, soil thermal conditions govern the liquid water content, while thaw depth influences both the height of the water column and, consequently, the pressure at the thawing front. These factors affect soil properties, such as cohesion and internal friction angle, which are crucial determinants of slope stability. This underscores the significance of a precise understanding of subsurface thermal conditions, including spatial and temporal variability in soil temperature and thaw depth, when assessing and predicting slope instabilities. Based on our observations, we developed a Factor of Safety proxy that consistently falls below the triggering threshold for all probes exhibiting displacements exceeding 50 mm. This study offers novel insights into patterns and triggers of hillslope movements in the Arctic and provides a venue to evaluate their impact on soil redistribution.

54 ENVIRONMENTAL SCIENCES↗

Passive Microwave Measurements of Salinity: The Gulf Stream Experiment

Passive microwave sensors at L-band (1.4 GHz) operating from aircraft have demonstrated that salinity can be measured with sufficient accuracy (I psu) to be scientifically meaningful in coastal waters. However, measuring salinity in the open ocean presents unresolved issues largely because of the much greater accuracy (approximately 0.2 psu) required of global maps to be scientifically viable. The development of a satellite microwave instrument to make global measurements of SSS (Sea Surface Salinity) is the focus of a joint JPL/GSFC/NASA ocean research program called Aquarius. In the summer of 1999 a series of measurements called, The Gulf Stream Experiment, were conducted as part of research at the Goddard Space Flight Center to test the potential for passive microwave remote sensing of salinity in the open ocean. The measurements consisted of airborne microwave instruments together with ships and drifters for surface truth. The study area was a 200 km by 100 km rectangle about 250 km east of Delaware Bay between the continental shelf waters and north wall of the Gulf Stream. The primary passive instruments were the ESTAR radiometer (L-band, H-pol) and the SLFMR radiometer (L-band, V-pol). In addition, the instruments on the aircraft included a C-band radiometer (ACMR), an ocean wave scatterometer (ROWS) and an infrared radiometer (for surface temperature). These instruments were mounted on the NASA P-3 Orion aircraft. Sea surface measurements consisted of thermosalinograph data provided by the R/V Cape Henlopen and the MN Oleander, and data from salinity and temperature sensors on three surface drifters deployed from the R/V Cape Henlopen. The primary experiment period was August 26-September 2, 1999. During this period the salinity field within the study area consisted of a gradient on the order of 2-3 psu in the vicinity of the shelf break and a warm core ring with a gradient of 1-2 psu. Detailed maps were made with the airborne sensors on August 28 and 29 and on September 2 flights were made over the surface drifters to look for effects due to a change in surface roughness resulting from the passage of Hurricane Dennis. Results show a good agreement between the microwave measurements and ship measurements of salinity. The features of the brightness temperature maps correspond well with the features of the salinity field measured by the ship and drifters and a preliminary retrieval of salinity compares well with the ship data.

LeVine, D. M.↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Salinity Measurements During the Gulf Stream Experiment

The salinity of the open ocean is important for understanding ocean circulation, for understanding energy exchange with the atmosphere and for improving models to predict weather and climate. Passive microwave sensors at L-band (1.4 GHz) operating from aircraft have demonstrated that salinity can be measured with sufficient accuracy (1 psu) to be scientifically meaningful in coastal waters. However, measuring salinity in the open ocean presents unresolved issues largely because of the much greater accuracy (approx. 0.1 psu) required to be scientifically viable. In the summer of 1999 a series of measurements called, The Gulf Stream Experiment, were conducted as part of research at the Goddard Space Flight Center to test the potential for passive microwave remote sensing of salinity in the open ocean. The measurements consisted of a compliment of airborne microwave instruments (radiometers and scatterometer) and ships and drifters for surface truth. The study area was a 200 km by 100 km rectangle about 250 km east of Delaware Bay between the continental shelf waters and north wall of the Gulf Stream. The primary passive instruments were the ESTAR radiometer (L-band, H-pol) and the SLFMR radiometer (L-band, V-pol). In addition, the compliment of instruments on the aircraft included a C-band radiometer (ACMR), an ocean wave scatterometer (ROWS) and an infrared radiometer. A GPS backscatter experiment was also part of the package. These instruments were mounted on the NASA P-3 Orion aircraft. Surface salinity measurements were provided by the RN Cape Henlopen and MN Oleander (thermosalinographs) plus salinity and temperature sensors on three surface drifters deployed from the RN Cape Henopen. The primary experiment period was August 26-September 2, 1999. During this period the salinity field within the study area consisted of a gradient on the order of 2-3 psu in the vicinity of the shelf break and a warm core ring with a gradient of 1-2 psu. Detailed maps were made with the airborne sensors on August 28 and 29 and on September 2 flights were made over the surface drifters to look for effects due to a change in surface roughness resulting from the passage of Hurricane Dennis. Preliminary results show a good agreement between the microwave measurements and ship measurements of salinity. The features of the brightness temperature maps correspond well with the features of the salinity field measured by the ship and drifters and a preliminary retrieval of salinity compares well with the ship data.

LeVine, D. M.↗

Coherence-mediated quantum thermometry in a hybrid circuit quantum electrodynamics architecture

Quantum thermometry plays a critical role in the development of low-temperature sensors and quantum information platforms. Here, in this work, we propose and analyze a hybrid circuit quantum electrodynamics architecture in which a superconducting qubit is dispersively coupled to two distinct bosonic modes: one initialized in a weak coherent state as a phase reference and information buffer and the other coupled to a thermal environment. We show that the qubit serves as a sensitive readout of the probe mode, mapping the interplay between thermal and coherent photon-number fluctuations onto measurable dephasing. This coherence-mediated mechanism enables improved sensitivity to thermal energy fluctuations in the sub-millikelvin regime through Ramsey interferometry. We derive analytic expressions for the probe coherence envelope, compute the quantum Fisher information for temperature estimation, and demonstrate numerically that the presence of a coherent reference enhances the qubit's sensitivity to small changes in thermal photon occupancy. Our results establish a coherence-enabled approach to thermometry and provide a scalable platform for future calorimetric sensing in high-energy physics and quantum metrology.

Zhu, Shaojiang [Fermi National Accelerator Laborat↗

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

Liquefaction of Cryogenic Fluids for Production and Storage of Commodities on Extra-Terrestrial Surfaces

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) activity has been investigating concepts for the liquefaction of cryogenic fluids produced on the surface of the Moon and Mars. CryoFILL consists of four activities: liquid nitrogen liquefaction testing that was completed in 2019, liquid oxygen liquefaction testing planned to begin in early 2022, fiber-optic sensor temperature measurement system development, and lightweight vacuum jacketed systems designed for the atmosphere of Mars. Additional activities include the development and validation of numerical modeling systems at three stages: thermodynamic models of the liquefaction process for basic energy/mass estimates, nodal models to predict liquefaction tank system level performance, and computational fluid dynamics to assess fluid phenomena occurring within the tank, specifically condensation and stratification within the ullage. These developments form a combined liquefaction and storage solution to support Lunar and Martian exploration. Key testing results from liquid nitrogen testing as well as plans for liquid oxygen testing will be discussed including key sensitivities from analytical evaluation of completed test results. Progress on the development and improvements on fiber optic sensor testing and developments will also be provided. Finally, work on the progress of the lightweight vacuum jacketed systems being co-developed by NASA and industry will be summarized.

Liquefaction↗

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗

Embedding ceramic components in metal structures with hybrid directed energy deposition

The combined benefit of both additive and subtractive manufacturing within the same gantry system enables hybrid directed energy deposition to create complex geometries with smooth surface finish and superior dimensional accuracy. Moreover, with layer-by-layer access to the structure during both the addition and subtraction of material, the insertion of components is now possible, assuming the components can survive the high temperatures associated with the subsequent metal deposition. Ceramic inserts are of interest for a variety of reasons including (1) to create complex interwoven ductile/brittle composites for ballistics or high-temperature applications or (2) to integrate high-temperature strain or temperature sensors protected within ceramic substrate subsumed into a larger metal structure. Here, in this work, stainless steel substrates were machined to create an internal cavity for the insertion of a ceramic component. During the investigation of several different over-the-ceramic deposition strategies, components were inserted, and different process sequences were allowed to continue to envelop the inserted ceramic with varying success. Unmelted powder was used to serve both as a thermal buffer and to provide a flush surface upon which the laser cladding could continue. Subsequent depositions were attempted with both dry and wet powder (addition of machining coolant to wet). The wet powder has previously been demonstrated to not significantly impact the mechanical properties of a final structure and provided a thermal barrier to protect the ceramic piece from the extreme temperatures of the final metal deposition. The wetting of the powder provided stability and minimized displacement caused by the powder flow from the laser cladding head. Finally, the use of an oblique angle for laser cladding allowed for the redirection of some fraction of the introduced thermal energy away from the ceramic component and, consequently, improved the survival of the ceramic inserts. With this combination of techniques, ceramic inserts survived full embedding within a 3D-printed stainless steel structure.

36 MATERIALS SCIENCE↗

ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its characteristics were considered favorable relative to similar instrumentation technologies (competitors), as determined from the Instrumentation Survey (2). The instrumentation technologies recommended by this study show considerable potential for development and promise significant returns if research efforts are invested.

Source record↗

Noise Radar Approach for Interrogating SAW Sensors Using Software Defined Radio

Passive, wireless surface acoustic wave (SAW) sensor systems can be approached from a radar perspective, where the SAW device is thought of as a cooperative target. Here, this paper investigates the use of a commercial-off-the-shelf software defined radio to interrogate wireless SAW sensors with a randomly generated interrogation pulse. The USRP B200mini is utilized as the transceiver platform with custom field-programmable gate array (FPGA) modifications to generate the random interrogation waveform and provide synchronization and buffering to the received signal. Each transmit sample bit in the FPGA is fed by an independent linear-feedback shift register, which generates pseudo-random I and Q samples for the interrogation pulse. An RF daughterboard has also been developed and integrated with the B200mini to increase the transmit power, provide filtering of the RF signals, and switch a signal antenna between the transmit and receive channels. Radio control and matched filter correlator post-processing are accomplished using Python. Design and implementation details for the FPGA modifications, RF daughterboard, and post-processing are discussed. Lastly, the system is demonstrated by wirelessly interrogating SAW temperature sensors at 915 MHz.

47 OTHER INSTRUMENTATION↗