Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A Nonconventional CO2-EOR Target in the Illinois Basin: Oil Reservoirs of the Thick Cypress Sandstone

The benefits of the project to the US Department of Energy Program, project overview, methodology, and accomplishments to date, such as water saturation profiles developed during petrophysical analysis; isopach maps developed during geologic modeling; and three-dimensional geocellular models that incorporate interpretations of depositional and diagenetic facies developed during geologic modeling.

Webb, Nathan↗

Thrust Generation with Low-Power Continuous-Wave Laser and Aluminum Foil Interaction

The micro-newton thrust generation was observed through low-power continuous-wave laser and aluminum foil interaction without any remarkable ablation of the target surface. To evaluate the thrust characteristics, a torsion-balance thrust stand capable for the measurement of the thrust level down to micro-Newton ranges was developed. In the case of an aluminum foil target with 12.5 micrometer thickness, the maximum thrust level was 15 micro-newtons when the laser power was 20 W, or about 0.75 N/MW. It was also found that the laser intensity, or laser power per unit area, irradiated on the target was significantly important on the control of the thrust even under the low-intensity level.

36 MATERIALS SCIENCE↗

Microjet printing of metal salt or oxide targets for nuclear reaction studies on radionuclides

Radioactive targets for direct measurements of neutron-induced reactions are required to improve evaluated cross-section data and, ultimately, the fidelity of neutron reaction network simulations. Electrodeposition and molecular plating are the current state-of-the-art radioactive target production techniques, but not all metals can be electrodeposited or molecular plated with high yields. Alternative techniques can be expensive or may produce targets that are unsatisfactory in terms of thickness, yield, or purity. Microjet printing is a new, rather inexpensive technique that utilizes equipment with a small footprint and has the potential to produce thin, highly radioactive targets with good uniformity and minimal impurities from the target fabrication process. This study involved optimizing the process of producing microjet printed targets to allow for the fabrication of a stable vanadium(V) oxide (V 2 O 5 ) target that was compared with an analogous electrodeposition V 2 O 5 target manufactured via the application of a vanadium chemical conversion coating on aluminum (Al) foil. Finally, the results from these studies suggest microjet printing could be used to produce relatively uniform target layers with adequate film thicknesses (< 15 μm). V 2 O 5 microjet printed targets, when compared with chemical conversion coating V 2 O 5 targets, appeared to be qualitatively less uniform and quantitatively larger in thickness (11.7(27) μm vs. 5.3(18) μm). However, the conversion coating target contained more impurities and the Al backing had a higher background contribution to measurements of neutron-induced reactions as opposed to targets produced via microjet printing. Overall, the results from this study suggest microjet printing has the capability to be an excellent alternative target production technique to the electrodeposition and molecular plating methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Nb2O5 and V2O5 addition on the superconducting properties of YBa2Cu3O(y) thin films

The effect of Nb2O5 and V2O5 addition on the superconducting properties and microstructure of YBa2Cu3O(y) has been studied in thin films. Polycrystalline targets for laser ablation were prepared by mixing high purity V2O5 or Nb2O5 powders with a well characterized YBa2Cu3O(y) powder in the range 0 to 4 wt percent by solid state reaction method. Thin films (approximately 1500 A thickness) of the above targets were grown on (100) SrTiO3 (STO) and (100) LaAlO3 (LAO) substrates at 700 C temperature by pulsed laser deposition (PLD) technique. In the case of Nb2O5 addition we have noticed an increase in J(sub c) up to 0.5 wt percent and higher additive concentration (greater than 0.5 wt percent) have degraded the superconducting properties. However, in the case of V2O3 addition, there is an improvement in current density and microstructural properties up to 1 wt percent and the superconducting properties degrade for concentrations greater than 1 wt percent. The best J(sub c) for 0.5 wt percent of Nb2O5 added YBCO thin film is 1.6 x 10(exp 6) A/sq cm and for that of V2O5 added sample is 3.4 x 10(exp 6) A/sq cm at 77 K as compared to the pure YBa2Cu3O(y) (YBCO) film J(sub c) (1.2 x 10(exp 6) A/sq cm) observed on STO substrates. The reason for improvement in J(sub c) and microstructural properties in the case of V2O5 addition could be due to the low melting of V2O5 (690 C) which can act as a very good surfactant during deposition. Over all, we have realized that Nb2O5 addition or V2O5 addition to YBCO have shown significant improvement over the undoped YBa2Cu3O(7-x) films grown under identical conditions.

Srinivas, S.↗

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of laser entrance hole foil thickness on MagLIF-relevant laser preheat

The magnetized liner inertial fusion (MagLIF) scheme relies on coupling laser energy into an underdense fuel raising the fuel adiabat at the start of the implosion. To deposit energy into the fuel, the laser must first penetrate a laser entrance hole (LEH) foil which can be a significant energy sink and introduce mix. In this paper, we report on experiments investigating laser energy coupling into MagLIF-relevant gas cell targets with LEH foil thicknesses varying from 0.5 μm to 3 μm. Two-dimensional (2D) axisymmetric simulations match the experimental results well for 0.5 μm and 1 μm thick LEH foils but exhibit whole-beam self-focusing and excessive penetration of the laser into the gas for 2 μm and 3 μm thick LEH foils. Additionally, better agreement for the 2 μm-thick foil is found when using a different thermal conductivity model in 2D simulations, while only 3D Cartesian simulations come close to matching the 3 μm-thick foil experiments. The study suggests that simulations may over-predict the tendency for the laser to self-focus during MagLIF preheat when thicker LEH foils are used. This effect is pronounced with 2D simulations where the azimuthally symmetric density channel effectively self-focuses the rays that are forced to traverse the center of the plasma. The extra degree of freedom in 3D simulations significantly reduces this effect. The experiments and simulations also suggest that, in this study, the amount of energy coupled into the gas is highly correlated with the laser propagation length regardless of the LEH foil thickness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test Bench Studies and Simulations of Atomic Beam Sources

Two new test bench studies have deepened the understanding of polarized gas targets and the atomic beam sources (ABS) that fill them. The attenuation coefficient for beam loss due to rest gas scattering has been measured over a range of beam velocities. The total scattering cross sections can be extracted from these measurements for the first time. Low conductance injection tubes have the potential to increase the thickness of storage cell targets. Injection tubes with internal fins were characterized, and the beam loss at the tube exit was larger than expected. Beam simulations agree with the measured intensity loss only when the atoms' trajectories have a non-zero azimuthal velocity component.

43 PARTICLE ACCELERATORS↗

Large solar flare radiation shielding requirements for manned interplanetary missions

Estimates are given for the radiation shielding thicknesses required to protect astronauts on interplanetary missions from the effects of large solar flares, on the basis of the integral proton fluences for several past solar particle events. NASA-Langley's nucleon transport deterministic computer code, BRYNTRN, is used to transport primary protons and secondary protons and neutrons through any number of layers of target material of arbitrary thickness and composition. The results of each flare are presented as estimates of dose equivalents to the skin, eyes, and blood-forming organs behind various thicknesses of aluminum shielding.

Townsend, Lawrence W.↗

Structure studies of 13 Be from the 12 Be ⁢(𝑑,𝑝) reaction in inverse kinematics on a solid deuteron target

The low-lying structure of 13 Be has remained an enigma for decades. Despite numerous experimental and theoretical studies, large inconsistencies remain. Being both unbound and one neutron away from 14 Be, the heaviest bound beryllium nucleus, 13 Be is difficult to study through simple reactions with weak radioactive-ion beams or more complex reactions with stable-ion beams. Here, we present the results of a study using the 12 Be (𝑑,𝑝)⁢ 13 Be reaction in inverse kinematics using a 9.5 MeV per nucleon 12 Be beam from the ISAC-II facility. The solid deuteron target of IRIS was used to achieve an increased areal thickness compared to conventional deuterated polyethylene targets. The 𝑄-value spectrum below −4.4 MeV was analyzed using a Bayesian method with geant4 simulations. A three-point angular distribution with the same 𝑄-value gate was fit with a mixture of 𝑠- and 𝑝-wave, 𝑠- and 𝑑-wave, or pure 𝑝-wave transfer. The 𝑄-value spectrum was also compared with geant simulations obtained using the energies and widths of states reported in four previous works. As a result, it was found that our results are incompatible with works that revealed a wide 5/2 + resonance but shows better agreement with ones that reported a narrower width.

6 ≤ A ≤ 19↗

TU-H-BRC-08: Use and Validation of Flexible 3D Printed Tissue Compensators for Post-Mastectomy Radiation Therapy

Purpose: Patient-specific tissue equivalent compensators can be used for post-mastectomy radiation therapy (PMRT) to achieve homogenous dose distributions with single-field treatments. However, current fabrication methods are time consuming and expensive. 3D-printing technology could overcome these limitations. The purposes of this study were to [1] evaluate materials for 3D-printed compensators [2] design and print a compensator to achieve a uniform thickness to a clinical target volume (CTV), and [3] demonstrate that a single-field electron compensator plan is a clinically feasible treatment option for PMRT. Methods: Blocks were printed with three materials; print accuracy, density, Hounsfield units (HU), and percent depth doses (PDD) were evaluated. For a CT scan of an anthropomorphic phantom, we used a ray-tracing method to design a compensator that achieved uniform thickness from compensator surface to CTV. The compensator was printed with flexible tissue equivalent material whose physical and radiological properties were most similar to soft tissue. A single-field electron compensator plan was designed and compared with two standard-of-care techniques. The compensator plan was validated with thermoluminescent dosimeter (TLD) measurements. Results: We identified an appropriate material for 3D-printed compensators that had high print accuracy (99.6%) and was similar to soft tissue; density was 1.04, HU was - 45 ± 43, and PDD curves agreed with clinical curves within 3 mm. We designed and printed a compensator that conformed well to the phantom surface and created a uniform thickness to the CTV. In-house fabrication was simple and inexpensive (<$75). Compared with the two standard plans, the compensator plan resulted in overall more homogeneous dose distributions and performed similarly in terms of lung/heart doses and 90% isodose coverage of the CTV. TLD measurements agreed well with planned doses (within 5 %). Conclusions: We have demonstrated that 3D-printed compensators make single-field electron therapy a clinically feasible treatment option for PMRT.

60 APPLIED LIFE SCIENCES↗

The influence of thermomechanical treatment pathways on texture and mechanical properties in ARB Cu/Nb nanolaminates

Accumulative roll-bonded Cu/Nb nanolaminates (ARB Cu/Nb) possess high strength, thermal stability, and radiation tolerance arising from a high content of heterophase interfaces at fine layer thicknesses. These properties can be tailored by processing parameters used in the ARB Cu/Nb fabrication process, in which layer thickness, thermal history, and strain pathway determine the interface types and resultant properties found in the material. In this work, we subject ARB Cu/Nb to annealing, and then two different rolling pathways – one where rolling direction is held constant (longitudinal rolling, or LR), and one where rolling direction is rotated by 90º and held constant thereafter (cross rolling, or CR). Rolling is performed on ARB Cu/Nb over a targeted range of layer thicknesses from 193 to 25 nm and resultant bulk textures measured by neutron diffraction are correlated with mechanical properties measured by miniaturized tensile tests. The annealing procedure sharpens texture in both phases. We find that Cu mostly develops the same texture in LR and CR. In contrast, Nb develops a distinct texture along the CR pathway that is distinct from the LR texture. The composite texture of Cu/Nb is thus distinct between LR and CR pathways. This difference in texture development between Cu and Nb as a function of strain after change in rolling direction demonstrates the viability for deliberate pairing of Cu LR and Nb CR textures at a desired layer thickness. For mechanical properties, we find that differences in texture do not result in yield or flow stress differences above a layer thickness of 25 nm. Below a layer thickness of 25 nm, despite similar Taylor factors, yield and flow stress and are significantly different. In conclusion, this indicates texture only influences mechanical behavior at low layer thickness, where interface structure dominates mechanical properties.

36 MATERIALS SCIENCE↗

Sustainable production of radionuclidically pure antimony-119

Background Radiopharmaceutical therapy (RPT) uses radionuclides that decay via one of three therapeutically relevant decay modes (alpha, beta, and internal conversion (IC) / Auger electron (AE) emission) to deliver short range, highly damaging radiation inside of diseased cells, maintaining localized dose distribution and sparing healthy cells. Antimony-119 ( 119 Sb, t 1/2 = 38.19 h, EC = 100%) is one such IC/AE emitting radionuclide, previously limited to in silico computational investigation due to barriers in production, chemical separation, and chelation. A theranostic (therapeutic/diagnostic) pair can be formed with 119 Sb’s radioisotopic imaging analogue 117 Sb (t 1/2 = 2.80 h, E γ = 158.6 keV, I γ = 85.9%, β + = 262.4 keV, I β+ = 1.81%). Results Within, we report techniques for sustainable and cost-effective production of pre-clinical quality and quantity, radionuclidically pure 119 Sb and 117 Sb, novel low energy photon measurement techniques for 119 Sb activity determination, and physical yields for various tin target isotopic enrichments and thicknesses using (p, n) and (d, n) nuclear reactions. Additionally, we present a two-column separation providing a radioantimony yield of 73.1% ± 6.9% (N = 3) and tin separation factor of (6.8 ± 5.5) x 10 5 (N = 3). Apparent molar activity measurements for deuteron produced 117 Sb using the chelator TREN-CAM were measured at 42.4 ± 25 MBq 117 Sb/µmol (1.14 ± 0.68 mCi/µmol), and we recovered enriched 119 Sn target material at a recycling efficiency of 80.2% ± 5.5% (N = 6) with losses of 11.6 mg ± 0.8 mg (N = 6) per production. Conclusion We report significant steps in overcoming barriers in 119 Sb production, chemical isolation and purification, enriched target material recycling, and chelation, helping promote accessibility and application of this promising therapeutic radionuclide. We describe a method for 119 Sb activity measurement using its low energy gamma (23.87 keV), negating the need for attenuation correction. Finally, we report the largest yet-measured 119 Sb production yields using proton and deuteron irradiation of natural and enriched targets and radioisotopic purity > 99.8% at end of purification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantification of uncertainty in photon source spot size inference during laser-driven radiography experiments at TRIDENT

Images of the R2DTO resolution target were obtained during laser-driven-radiography experiments performed at the TRIDENT laser facility, and analysis of these images using the Bayesian Inference Engine (BIE) determines a most probable full-width half maximum (FWHM) spot size of 78 μm. However, significant uncertainty prevails due to variation in the measured detector blur. Propagating this uncertainty in detector blur through the forward model results in an interval of probabilistic ambiguity spanning approximately 35-195 μm when the laser energy impinges on a thick (1 mm) tantalum target. In other phases of the experiment, laser energy is deposited on a thin (~100 nm) aluminum target placed 250 μm ahead of the tantalum converter. When the energetic electron beam is generated in this manner, upstream from the bremsstrahlung converter, the inferred spot size shifts to a range of much larger values, approximately 270-600 μm FWHM. This report discusses methods applied to obtain these intervals as well as concepts necessary for interpreting the result within a context of probabilistic quantitative inference.

47 OTHER INSTRUMENTATION↗

SU-F-T-157: Physics Considerations Regarding Dosimetric Accuracy of Analytical Dose Calculations for Small Field Proton Therapy: A Monte Carlo Study

Purpose: To evaluate the accuracy of dose calculations by analytical dose calculation methods (ADC) for small field proton therapy in a gantry based passive scattering facility. Methods: 50 patients with intra-cranial disease were evaluated in the study. Treatment plans followed standard prescription and optimization procedures of proton stereotactic radiosurgery. Dose distributions calculated with the Monte Carlo (MC) toolkit TOPAS were used to represent delivered treatments. The MC dose was first adjusted using the output factor (OF) applied clinically. This factor is determined from the field size and the prescribed range. We then introduced a normalization factor to measure the difference in mean dose between the delivered dose (MC dose with OF) and the dose calculated by ADC for each beam. The normalization was determined by the mean dose of the center voxels of the target area. We compared delivered dose distributions and those calculated by ADC in terms of dose volume histogram parameters and beam range distributions. Results: The mean target dose for a whole treatment is generally within 5% comparing delivered dose (MC dose with OF) and ADC dose. However, the differences can be as great as 11% for shallow and small target treated with a thick range compensator. Applying the normalization factor to the MC dose with OF can reduce the mean dose difference to less than 3%. Considering range uncertainties, the generally applied margins (3.5% of the prescribed range + 1mm) to cover uncertainties in range might not be sufficient to guarantee tumor coverage. The range difference for R90 (90% distal dose falloff) is affected by multiple factors, such as the heterogeneity index. Conclusion: This study indicates insufficient accuracy calculating proton doses using ADC. Our results suggest that uncertainties of target doses are reduced using MC techniques, improving the dosimetric accuracy for proton stereotactic radiosurgery. The work was supported by NIH/NCI under CA U19 021239. CG was partially supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087).

60 APPLIED LIFE SCIENCES↗

Effects of laser radiation on immobile and fast-moving targets

We have studied the effects of laser pulses up to 50 J in energy and up to 1100 {mu}s in duration, with a rise time of {approx}300 {mu}s, on immobile and moving (linear velocity of up to 10{sup 4} cm s{sup -1}) stainless steel targets. The results indicate that, in the vapour above an immobile target, optical breakdown develops at a spot-averaged power density of 5.5x10{sup 6} W cm{sup -2}, against 7.3x10{sup 6} W cm{sup -2} in air. This undesirable effect can be eliminated even at an order of magnitude higher incident power density by rapidly rotating the target (linear velocity of {approx}50 cm s{sup -1} relative to the laser beam). At incident power densities in the range (0.6-1.2)x10{sup 7} W cm{sup -2} (incident powers from 12 to 24 kW), evaporation from a rotating target is intermittent. To interpret this effect, a numerical model is developed which takes into account the influence of target burning. Its predictions agree with the evaporation behaviour observed in our experiments. The thicknesses of the evaporated and molten layers are evaluated as functions of laser beam parameters and target velocity, with reference to the optimisation of laser surface processing conditions. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detailed characterization of the LLNL imaging proton spectrometer

Ultra-intense short pulse lasers incident on solid targets (e.g., thin Au foils) produce well collimated, broad-spectrum proton beams. These proton beams can be used to characterize magnetic fields, electric fields, and density gradients in high energy-density systems. The LLNL-Imaging Proton Spectrometer (L-IPS) was designed and built [H. Chen et al., Rev. Sci. Instrum. 81, 10D314 (2010)] for use with such laser produced proton beams. The L-IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 275 at 1 MeV and 21 at 20 MeV, as well as a single spatial imaging axis. In order to better characterize the dispersion and imaging capability of this diagnostic, a 3D finite element analysis solver is used to calculate the magnetic field of the L-IPS. Particle trajectories are then obtained via numerical integration to determine the dispersion relation of the L-IPS in both energy and angular space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A feasibility study of using advanced external beam techniques to create a vaginal cuff brachytherapy-like endometrial boost plan

The purpose of this study was to explore the feasibility of using advanced external beam radiation therapy (EBRT) planning techniques for creating plans that could be used as a possible alternative for high-dose rate (HDR) vaginal cuff brachytherapy (VCBT) boost in treating endometrial cancer. The computed tomography (CT) images of a total of 4 female patients who had endometrial cancer treated with HDR-VCBT were selected for this study. A typical HDR-VCBT target volume, 0.5-cm-thick shell volume around the cylinder applicator in the prescribed treatment length was contoured and used as the planning target volume (PTV) in both the HDR VCBT and the EBRT VCBT-like plans. HDR-VCBT plans were made based on the clinical protocol, 6 Gy given at the cylinder surface. The EBRT plans were generated using either a 7-field intensity-modulated radiation therapy (IMRT) or a 2-arc volumetric-modulated arc therapy (VMAT) techniques for different cylinder sizes and treatment lengths, with the prescription dose of 5 Gy. Organs at risk (OARs) such as bladder, femoral heads, rectum, and sigmoid were also contoured and used in dosimetric evaluations. Dose-to-target metrics included mean dose, the dose covering 90% of target volume (D90) and the percentage of target volume covered by 90% of prescription dose (V90 or V13.5 Gy). Dose to OAR metrics included the maximum dose received by 0.1 cc (D0.1cc), 1.0 cc (D1.0cc), and 2.0 cc (D2.0cc) of OARs. These metrics were calculated and compared between all techniques. After the EBRT plans were normalized to achieve a comparable mean dose to target as HDR-VCBT, the EBRT plans were found to have superior target coverage and increased dose homogeneity compared with HDR-VCBT. V90s of EBRT plans were 95%, compared with 50% to 58% of the HDR plans. However, D0.1cc, D1.0cc, and D2.0cc of OARs were 2% to 38% lower in HDR-VCBT than in EBRT. Although HDR-VCBT plans demonstrated superior normal tissue sparing, both EBRT and HDR-VCBT plans produce plans that met clinical dose constraints on normal tissues. Advanced EBRT techniques such as IMRT and VMAT are capable of making plans, which closely resemble HDR-VCBT. Although the doses of OARs are greater in EBRT than in HDR-VCBT, the prescription dose coverage and dose homogeneity of the EBRT plans are greater than that of HDR-VCBT plans at the similar mean dose, and the OAR dose is still acceptable with EBRT plans. The detailed dosimetric approaches are provided in the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sputter coating of Nb₃Sn into SRF cavity using stoichiometric target

Nb₃Sn has emerged as a leading alternative material due to its higher superconducting critical temperature (Tc) and superheating field (Hsh), promising a viable solution to the intrinsic performance limit currently faced by Nb superconducting radiofrequency (SRF) cavities. We sputter-coated Nb₃Sn inside Nb SRF cavity using a stoichiometric Nb₃Sn tube target in a DC cylindrical magnetron sputter coater. The target was fabricated by growing an estimated >20 μm thick Nb₃Sn layer on a Nb tube via Sn vapor diffusion using Jefferson Lab’s coating system. Approximately 150 nm thick Nb-Sn films were sputter-deposited onto flat Nb samples at positions representing the beam tubes and equator of a 2.6 GHz Nb cavity. Post-deposition annealing at 950 °C for 3 h resulted in the formation of Nb₃Sn. Microstructural analysis of the annealed films was carried out to investigate the morphology and structure of the Nb₃Sn films. Later, a 2.6 GHz Nb SRF cavity was coated with a ~1.2 μm thick sputtered Nb-Sn film using a stoichiometric Nb₃Sn target, followed by annealing. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, indicating the formation of Nb₃Sn. After a light Sn recoating treatment, the cavity achieved a quality factor (Q0) of 6.7E+08 at lower field at 2.0 K.

Accelerator Physics↗