Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A novel experimental system for the KDK measurement of the 40 K decay scheme relevant for rare event searches

Potassium-40 ( 40 K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. 40 K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpretingcertain results or can lead to lack of precision depending on the field and analysis technique. Additionally, the KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited 40 K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr 2 I 5 :Eu scintillator as source and detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formulation and solution approach for calibrating activity-based travel demand model-system via microsimulation

This study addresses the problem of calibrating utility-maximizing nested logit activity-based travel demand model-systems. After estimation, it is common practice to use aggregate measurements to calibrate the estimated model-system’s parameters prior to their application in transportation planning, policy making, and operations. However, calibration of activity-based model-systems has received much less attention. Existing calibration approaches are myopic heuristics in the sense that they do not consider the fundamental inter-dependencies among choice-models and do not have a systematic way to adjust model parameters. Also, other purely simulation-based approaches do not perform well in large-scale applications. In this study, we focus on utility-maximizing nested logit activity-based model-systems and calibrating aggregate statistics such as activity shares, mode shares, time-dependent & mode-specific OD flows, and time-dependent & mode-specific sensor counts. We formulate the calibration problem as a simulation-based optimization problem and propose a stochastic gradient-based solution procedure to solve it. The solution procedure relies on microsimulation to calculate expectations of the aggregate statistics of interest to the calibration problem. Additionally, we derive approximate analytical expressions for the gradient of the objective function —that are evaluated through microsimulation on mini-batches of the population. The proposed solution procedure is sensitive to the fundamental structure of the activity-based model-system and is non-myopic in considering the dependencies across its model components. The formulated optimization problem is non-convex, highly nonlinear, and potentially has multiple-minima. Lastly, we show —through a real-world application— that the proposed solution procedure outperforms other state-of-the-art purely simulation-based optimization approaches in terms of computational efficiency, stability, and convergence. We also compare various gradient-based solution algorithms to determine the best algorithm to update the parameters. This work has the potential to facilitate wider and easier application of activity-based model-systems.

97 MATHEMATICS AND COMPUTING↗

Optimization Simulations for a Gamma-Ray Calibration Standard for a Cyclic Neutron Activation Analysis Pneumatic System at the Penn State Breazeale Reactor

For new experimental setups, the initial testing and calibrations can be expensive and time consuming without prior optimization. However, these issues can be mitigated using realistic modeling and simulation studies of the proposed system a priori. Specifically, an experiment can be performed virtually using realistic simulations and the expected results evaluated to inform adjustments of the experimental setup to achieve optimum results. At the Penn State Breazeale Reactor, a new pneumatic transfer system has been developed for the detection and characterization of short-lived fission fragments to enhance and complement existing nuclear data. The system accomplishes this task by transporting samples cyclically between an assortment of gamma-ray/neutron detectors and the reactor-core vicinity with sub-second transit times. The measured neutron flux paired with simulations of detector response using Geant4 and a custom module for estimating cascade summing effects and corrections were used to select sample-material masses for system characterization. With the optimized sample masses, an experimental counting plan for characterizing the repeatability of the newly developed pneumatic system was developed. Finally, the predictions made with these simulations allowed for optimization of the irradiation sample characteristics and gamma-ray detection system.

cyclic neutron activation, gamma-ray spectroscopy↗

SU-E-E-12: Validation of the Implementation of Different CT Scanners in Proton Treatment Planning

Purpose: To quantify the impact of the relationship of CT number and Relative Stopping Power (RSP) among different CT-scanners in the evaluation of dose distribution, for different tumor sites and proton therapy modalities like Pencil Beam and Uniform Scanning. Methods: The same tissue characterization phantom was used to analyze the difference in the X-rays energy spectra of 2 CT scanners of the same vendor. One CT is for planning and the other for treatment verification. The Hounsfield unit (HU) variations and associated dosimetric uncertainty were investigated in uniform scanning and pencil beam treatment plans of different sites. At the same time comparisons of the CT calibration curve were done using the same acquisition protocols. The phantom was imaged on a 16 multi-row CT scanner, with energies of 120 and 140 kVp,currents of 263 and 245 mA and slice thickness of 2 and 3mm respectively. The dosimetric uncertainty of the plans was evaluated in a homogeneus phantom comparing DVHs, gamma index criteria 3% 3mm, and range between them. Results: The variation of HU was within the standard deviation of the average for each tissue substitute. The curves fitted with a bilinear interpolation show a maximum deviation in high density materials like cortical bone and solid water, where the HU values deviated more than 0,6% for the 120kVp protocol. For the others curves the deviation was more than 2% for low densities materials. The gamma index uncertainty criteria passed in all the cases. Conclusion: The HU variations for the different scanners were ≤3%. Lower than the 3,5% uncertainties considered in our treatment planning system. The dosimetric analysis shows that the X-ray spectrum has a small effect on the HU-RSP curve, allowing the use of a single tissue characterization curve in our proton treatment planning system for plans verifications.

60 APPLIED LIFE SCIENCES↗

WE-G-BRA-04: Common Errors and Deficiencies in Radiation Oncology Practice

Purpose: Dosimetric errors in radiotherapy dose delivery lead to suboptimal treatments and outcomes. This work reviews the frequency and severity of dosimetric and programmatic errors identified by on-site audits performed by the IROC Houston QA center. Methods: IROC Houston on-site audits evaluate absolute beam calibration, relative dosimetry data compared to the treatment planning system data, and processes such as machine QA. Audits conducted from 2000-present were abstracted for recommendations, including type of recommendation and magnitude of error when applicable. Dosimetric recommendations corresponded to absolute dose errors >3% and relative dosimetry errors >2%. On-site audits of 1020 accelerators at 409 institutions were reviewed. Results: A total of 1280 recommendations were made (average 3.1/institution). The most common recommendation was for inadequate QA procedures per TG-40 and/or TG-142 (82% of institutions) with the most commonly noted deficiency being x-ray and electron off-axis constancy versus gantry angle. Dosimetrically, the most common errors in relative dosimetry were in small-field output factors (59% of institutions), wedge factors (33% of institutions), off-axis factors (21% of institutions), and photon PDD (18% of institutions). Errors in calibration were also problematic: 20% of institutions had an error in electron beam calibration, 8% had an error in photon beam calibration, and 7% had an error in brachytherapy source calibration. Almost all types of data reviewed included errors up to 7% although 20 institutions had errors in excess of 10%, and 5 had errors in excess of 20%. The frequency of electron calibration errors decreased significantly with time, but all other errors show non-significant changes. Conclusion: There are many common and often serious errors made during the establishment and maintenance of a radiotherapy program that can be identified through independent peer review. Physicists should be cautious, particularly in areas highlighted herein that show a tendency for errors.

60 APPLIED LIFE SCIENCES↗

A new scintillation hodoscope for CLAS12 and partial wave analysis of the channel yp → pK + K -

This thesis consists of two parts that have contributed to a new meson spectroscopy program, MesonEx, which is currently taking place in Hall B of the upgraded Thomas Jefferson National Accelerator Facility (JLab) in the USA. The first, hardware part, presents design, testing, construction and calibration of a fast-timing scintillation Hodoscope for a new Forward Tagger detector, that has been installed inside the upgraded CEBAF Large Acceptance Spectrometer (CLAS12) which is situated in the Hall B of JLab. The Forward Tagger is a key apparatus for measurement of quasi-real photoproduction of mesons in the MesonEx, and a necessary device for other new hadron spectroscopy programs. The second, software and analysis part, presents contributions to the general HAdron SPEctroscopy CenTre (HASPECT) analysis framework, that has been developed in preparation for the MesonEx data analysis. The software contribution consists of finalizing HASPECT simulation and analysis chains in a model-independent way, and developing a mass-independent partial wave analysis procedure. This procedure has been tested via analysis of the γ p → pK + K - channel from the g 11 a CLAS data, in the photon energy range E γ = 3.0-3.8 GeV and momentum transfer squared range -t = 0.6 - 0.7 (GeV/c 2 ) 2 . The first result of this analysis is the differential cross section for the ϕ(1020) resonance photoproduction. This result has been compared with a previous analysis result, and a good agreement has validated the developed analysis procedure. Furthermore, S , P and D partial waves have been extracted from the data set, using the same procedure, and ambiguous solutions for these partial waves have been calculated, using the method of Barrelet zeros which is for the first time applied to photoproduction of the K + and K - mesons on the proton. Distributions of the calculated solutions have been compared with the fit results. It is found that the physical solution contains contributions of the ϕ(1020) in the P -wave and the a 2(1320) in the D -wave.

Stankovic, Ivana↗

Rossi Alpha Measurements – Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) system capabilities

The Rossi Alpha Measurements–Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) is an array organic scintillation detectors that has been optimized for use in neutron noise measurements. This report details the capability of the system including the method of energy calibration, pulse shape discrimination, and time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LOFAR, VLA, and Chandra observations of the Toothbrush Galaxy Cluster

We present deep LOFAR observations between 120 {181 MHz of the `Toothbrush' (RX J0603.3+4214), a cluster that contains one of the brightest radio relic sources known. Our LOFAR observations exploit a new and novel calibration scheme to probe 10 times deeper than any previous study in this relatively unexplored part of the spectrum. The LOFAR observations, when combined with VLA, GMRT, and Chandra X-ray data, provide new information about the nature of cluster merger shocks and their role in re-accelerating relativistic particles. We derive a spectral index of α = -0:8±0:1 at the northern edge of the main radio relic, steepening towards the south to α ≈ -2. The spectral index of the radio halo is remarkably uniform (α = -1:16, with an intrinsic scatter of ≤ 0:04). The observed radio relic spectral index gives a Mach number of M = 2:8 +0:5 -0:3 , assuming diffusive shock acceleration (DSA). However, the gas density jump at the northern edge of the large radio relic implies a much weaker shock (M≈1:2, with an upper limit ofM≈1:5). The discrepancy between the Mach numbers calculated from the radio and X-rays can be explained if either (i) the relic traces a complex shock surface along the line of sight, or (ii) if the radio relic emission is produced by a re-accelerated population of fossil particles from a radio galaxy. Our results highlight the need for additional theoretical work and numerical simulations of particle acceleration and re-acceleration at cluster merger shocks.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Temperature Profiles in the Pedestal of NSTX with Reduced Models

This paper describes new modeling capabilities for predicting H-mode pedestal profiles in spherical tokamaks. Temperature profiles for NSTX discharges 132543 and 132588 are modeled by coupling the \textsc{astra} transport solver with neoclassical transport and gyrokinetic-based reduced models for electron temperature gradient (ETG) and kinetic ballooning mode (KBM) instabilities. A quasi-linear surrogate model for ion-scale transport is developed using linear \textsc{gene} simulations, requiring only a single free parameter calibrated to one discharge. Time-evolving the temperatures with fixed density yields good agreement with experiments for both discharges. Systematic analysis of the transport mechanisms reveals that neoclassical transport is huge across the entire pedestal region for the ion channel. ETG turbulence is large in the plasma edge and low density gradient region, contributing substantially to the electron channel. However, KBM/MHD-like modes also drive significant transport in both the ion and electron thermal channels, making them essential for accurate pedestal modeling. Further refinements, including explicit E×B shear suppression and scaled ETG transport, produce quantitative but not qualitative improvements. This work lays the foundation for predictive modeling of future devices. This paper is on arxiv and has been submitted to Nuclear Fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparing Measured Driver Behavior Distributions to Results from Car-Following Models using SUMO and Real-World Vehicle Trajectories from Radar: SUMO Default vs. Radar-Measured CF model Parameters

In this study, the physical principles governing car-following (CF) behavior and their impact on traffic flow at signalized intersections are investigated. High temporal-resolution radar data is used to provide valuable insights into actual CF behavior, including acceleration, deceleration, and time headway distribution. Demand-calibrated SUMO simulations are run using empirical CF parameter distributions, and three CF models are evaluated: IDM, EIDM, and Krauss. By emulating radar data in SUMO and processing simulated vehicle traces, discrepancies between empirical and simulated parameter distributions are identified. Further analysis includes comparisons with default SUMO CF model parameters. The findings reveal that measured accelerations differ from CF model parameter accelerations and using the empirical value ($\mu = 0.89m/s^2$) leads to unrealistic simulations that fail volume-based calibration. Default parameters for all three models reasonably approximate the mean and median of measured parameters, but fail to capture the true distribution shape, partly due to homogeneity when using default parameters. The results show that it is more effective to simulate with the default parameters provided by SUMO rather than using measurements of real-world distributions without additional calibration. Future work will investigate closing the loop between the measured real-world and SUMO distributions using traditional calibration tactics, as well as assess the impact of calibrated vs. default CF parameters on simulation outputs like fuel consumption.

Schrader, Max (ORCID:0000000336737672)↗

Smithsonian Astrophysical Observatory laser tracking systems

The four SAO laser satellite-ranging systems, located in Brazil, Peru, Australia, and Arizona, have been in operation for more than five years and have provided ranging data at accuracy levels of a meter or better. The paper examines system hardware (laser transmitter, the electronics, mount, photoreceiver, minicomputer, and station timing) and software (prediction program, calibration programs, and data handling and quick-look programs) and also considers calibration, station operation, and system performance.

Pearlman, M. R.↗

Measurement of suspended solids in lakes and oceans using satellite remote sensing data

Using satellite remote sensing data to measure low concentrations of suspended solids in lakes and oceans requires careful evaluation of background signals from the atmosphere and the water surface. Typical background corrections for Lake Superior are presented and the spectral distribution of the residual radiance from three major categories of turbidity in the lake are determined. The results indicate that for large bodies of water, some general information on atmospheric scattering, water clarity, and the optical properties of suspended solids allows estimates of concentrations of suspended solids to within + or - 0.5 mg/L without using real time ground truth data. Under calibrated conditions the threshold detection level is 0.3 mg/L for the fine particulates dispersed throughout the lake and 1 mg/L for the highly light absorbing effluent from rivers. Comparisons of the minimum reflectance over the open lake areas with reflection from the highly absorbing tannin water from rivers provides a check on the clarity of the atmosphere and the excessive background scatter from the water surface.

Sydor, M.↗

Multispectral Scanner (MSS) Instrument Description

The MSS sensor image processing and resolution capabilities as well as a general system description are presented in chart form. Emphasis is placed on absolute radiometric calibration, video and wedge level timing sequence, focal plane dimensions, sampling sequence, and a description of the mirror coordinate systems.

Barker, J. L.↗

SIR-B cartography and stereo topographic mapping

The SIR-B mapping experiment which will evaluate the utility of SAR images taken singularly, in pairs, and in combination with other data sets for cartographic, topographic, and thematic mapping, and determine the optimum configuration of a SAR system for future mapping mission is outlined. SIR-B is the first orbital imaging radar mission which will incorporate maintenance of geometric image fidelity along with careful calibration and documentation of internal timing and frequency parameters. This along and and the multiple incidence angle images of the same target which are necessary for stereoscopy and topographic mapping, make it the ideal opportunity for cartographic experimentation. It is emphasized that comprises a significant part of the overall experiment objectives.

Kobrick, M.↗

NASA three-laser airborne differential absorption lidar system electronics

The system control and signal conditioning electronics of the NASA three laser airborne differential absorption lidar (DIAL) system are described. The multipurpose DIAL system was developed for the remote measurement of gas and aerosol profiles in the troposphere and lower stratosphere. A brief description and photographs of the majority of electronics units developed under this contract are presented. The precision control system; which includes a master control unit, three combined NASA laser control interface/quantel control units, and three noise pulse discriminator/pockels cell pulser units; is described in detail. The need and design considerations for precision timing and control are discussed. Calibration procedures are included.

Allen, R. J.↗

Proceedings of the Third Airborne Imaging Spectrometer Data Analysis Workshop

Summaries of 17 papers presented at the workshop are published. After an overview of the imaging spectrometer program, time was spent discussing AIS calibration, performance, information extraction techniques, and the application of high spectral resolution imagery to problems of geology and botany.

Vane, Gregg↗

The Nimbus-7 Earth Radiation Budget (ERB) data set and its uses

The Nimbus-7 Earth Radiation Budget (ERB) instrument began recording data on November 16, 1978 and it is now in its 12th data year. The principle products are nine years of global albedo, outgoing longwave, and net radiation plus continuing solar irradiance measurements. The presence of an associated six-year Nimbus-7 global cloud data set enhances the usefulness of the ERB products. The chief purpose of this paper is to describe some uses that have been made of the data. These include studies in: regional energy heat budgets, the improvement of climate and weather prediction models, interannual climate variations, shortwave bidirectional reflectance from earth atmosphere scenes, and solar physics. The evolution of the data products with time and some algorithm and calibration problems are also briefly discussed. Despite numerous problems, the experiment continues to prove its usefulness.

Kyle, H. Lee↗

The Cepheid distance scale

Developments concerning the period-luminosity (PL) relation for classical Cepheids are discussed with particular emphasis on the fact that Cepheids continue to provide the most homogeneous and reliable set of distances to many nearby galaxies. Observational programs relating to extragalactic Cepheids are also reviewed, and new distances and reddenings to individual galaxies are determined from these data using multiwavelength PL relations, based for the first time on self-consistent calibrating data sets. Three recent promising secondary extragalactic distance indicators (Tully-Fisher, planetary nebula luminosity functions, and surface-brightness fluctuations) tie their zero points to the Cepheid distance scale and give globally consistent values for the Hubble constant of about 80 km/sec/Mpc. Tying the Faber-Jackson relation and the supernova distance scales to the Leo and Virgo clusters yields similar results. Such a value for the Hubble constant is marginally inconsistent with new estimates of the ages of globular clusters, and it may prove to be a serious problem for standard cold-dark-matter models of the universe.

Madore, Barry F.↗