Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Use of satellite data and modeling to assess the influence of stratospheric processes on the troposphere

Over the past forty years, numerous linear stability studies have been performed in order to explain the origin and structure of observed waves in the atmosphere. Of these studies, only a small fraction have considered the stability of time-dependent, zonally varying flow or the influence of radiative-photochemical feedbacks on the stability of zonally uniform flow. The stability of such flows is described, and these flows may yield important information concerning the origin, structure, and transient time scales of free waves in the atmosphere. During the period 1990 to 1991, a beta-plane model that couples radiative transfer, ozone advection, and ozone photochemistry with the quasigeostrophic dynamical circulation was developed in order to study the diabatic effects of Newtonian cooling and ozone-dynamics interaction on the linear stability of free planetary waves in the atmosphere. The stability of a basic state consisting of a westward-moving wave and a zonal mean jet was examined using a linearized, nondivergent barotropic model on sphere. The sensitivity of the stability of the flow to the strength and structure of the zonal jet was emphasized. The current research is focused on the following problems: (1) examination of the finite amplitude interactions among radiation, ozone, and dynamics; and (2) examination of the role of seasonal forcing in short-term climate variability. The plans for next year are presented.

Nathan, Terrence↗

Impedance of silver oxide-zinc cells

Over 100 sealed AgO-Zn cells were subjected to prolonged periods of storage over a range of temperatures and storage modes including open circuit, trickle charge, and float charge. Impedances of these cells were monitored throughout, and at the end of the storage period their transient voltage characteristics were observed at the onset of discharge. Results revealed that the impedances of these cells tended to increase with storage time; the magnitude of the impedance rise was dependent primarily on temperature and to a lesser degree on storage mode. Typical values for 50 A-hr cells were usually less than 100 mohm immediately after activation and from 1 to 30 ohm after 6-10 months of storage. Transient voltages of these cells droped sharply during the first msec of discharge and then rose to a stablized value during the following few seconds. The magnitude of the initial drop and the stabilized voltage values were found to be related to impedance but not in a linear manner. The magnitude and duration of the low transient voltages may be unacceptable in some applications of these cells. The impedance variations are attributed to changes occurring at the positive electrode.

Frank, H. A.↗

Development of a High Fidelity System Analysis Code for Generation IV Reactors

Traditional nuclear reactor system analysis codes such as RELAP and TRAC employ an operator split methodology. In this approach, each of the physics (fluid flow, heat conduction and neutron diffusion) is solved separately and the coupling terms are done explicitly. This approach limits accuracy (first order in time at best) and makes the codes slow in running since the explicit coupling imposes stability restrictions on the time step size. These codes have been extensively tested and validated for the existing LWRs. However, for GEN IV nuclear reactor designs which tend to have long lasting transients resulting from passive safety systems, the performance is questionable and modern high fidelity simulation tools will be required. The requirement for accurate predictability is the motivation for a large scale overhaul of all of the models and assumptions in transient nuclear reactor safety simulation software. At INL we have launched an effort with the long term goal of developing a high fidelity system analysis code that employs modern physical models, numerical methods, and computer science for transient safety analysis of GEN IV nuclear reactors. Modern parallel solution algorithms will be employed through utilizing the nonlinear solution software package PETSc developed by Argonne National Laboratory. The physical models to be developed will have physically realistic length scales and time scales. The solution algorithm will be based on the physics-based preconditioned Jacobian-free Newton-Krylov solution methods. In this approach all of the physical models are solved implicitly and simultaneously in a single nonlinear system. This includes the coolant flow, nonlinear heat conduction, neutron kinetics, and thermal radiation, etc. Including modern physical models and accurate space and time discretizations will allow the simulation capability to be second order accurate in space and in time. This paper presents the current status of the development efforts as well as some results from analyzing a simplified primary system model of GNEP’s advanced burner test reactor (ABTR) designed by Argonne. Various transient analyses are performed with this simplified ABTR model to study two fundamental issues related to system analysis codes – accuracy of numeric algorithm and efficiency. The accuracy study is carried by comparing the second order method with the first order method. The results show that numerical errors in the first order method are large and it is very difficult to distinguish numerical errors from physical modeling errors. On the other hand, second order method yields small numerical errors and it is very easy to spot physical modeling errors. The efficiency study is carried out by comparing the time steps for the fully implicit solution algorithm versus CFL stability limit methods. The dynamic time steps used in a fully implicit method will adjust the time step to resolve the time scale during the various stages of a long lasting transient. This will make a computer code based on fully implicit methods run more efficiently versus a CFL stability limit method code like RELAP, in which a particle of fluid cannot cross a control volume in a single time step.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Extending Lean and Exhaust Gas Recirculation-Dilute Operating Limits of a Modern Gasoline Direct-Injection Engine Using a Low-Energy Transient Plasma Ignition System

The efficiency improvement and emissions reduction potential of lean and exhaust gas recirculation (EGR)-dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nanosecond pulses and its performance compared to a conventional transistorized coil ignition (TCI) system operated on an automotive, gasoline direct-injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar indicated mean effective pressure (IMEP), where dilution tolerance is particularly critical to improving efficiency and emission performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ = 1.55 to 1.7) with the low-energy transient plasma ignition system.

33 ADVANCED PROPULSION SYSTEMS↗

A discussion of dynamic stability measurement techniques

Techniques for the measurement of the dynamic stability of linear systems are discussed. Particular attention is given to an analysis of the errors in the procedures, and to methods for calculating the system damping from the data. The techniques discussed include: transient decay, moving block analysis, spectral analysis, random decrement signatures, transfer function analysis, and parameter identification methods. The special problems of rotorcraft dynamic stability testing are discussed.

Johnson, W.↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Safety analysis of the FASt TEst reactor (FASTER) preconceptual design

Here, the FASt TEst Reactor (FASTER) plant is a sodium-cooled fast spectrum test reactor design that was developed as part of an advanced demonstration and test reactor study, and provides high levels of fast and thermal neutron flux for scientific research and development. The 120 MWe FASTER plant has been designed with extended testing capabilities in mind, while keeping the design as simple as possible in order to make it efficient and cost attractive. The main function of the reactor is to provide neutrons for irradiation testing utilizing existing proven technologies to ensure a high technology readiness level. A preliminary safety analysis was performed of the FASTER design using the fast reactor safety analysis code SAS4A/SASSYS-1 to assess the reactor's safety performance during beyond design basis accidents. Three types of transient scenarios were analyzed for the FASTER design: unprotected transient overpower, unprotected loss of heat sink, and unprotected station blackout. These transients were simulated at beginning of equilibrium cycle and end of equilibrium cycle conditions. For each transient, failures of both the primary and secondary reactor scram systems were assumed. Because of the favorable reactivity feedbacks, relatively low peak fuel, cladding, and coolant temperatures were obtained during the transients and the reactor vessel temperature remained well below the limit for ensuring structural stability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dodecagonal quasicrystalline order in a diblock copolymer melt

We report the discovery of a dodecagonal quasicrystalline state (DDQC) in a sphere (micelle) forming poly(isoprene-b-lactide) (IL) diblock copolymer melt, investigated as a function of time following rapid cooling from above the order–disorder transition temperature (T ODT = 66 °C) using small-angle X-ray scattering (SAXS) measurements. Between T ODT and the order–order transition temperature T OOT = 42 °C, an equilibrium body-centered cubic (BCC) structure forms, whereas below T OOT the Frank–Kasper σ phase is the stable morphology. At T < 40 °C the supercooled disordered state evolves into a metastable DDQC that transforms with time to the σ phase. The times required to form the DDQC and σ phases are strongly temperature dependent, requiring several hours and about 2 d at 35 °C and more than 10 and 200 d at 25 °C, respectively. Remarkably, the DDQC forms only from the supercooled disordered state, whereas the σ phase grows directly when the BCC phase is cooled below T OOT and vice versa upon heating. A transition in the rapidly supercooled disordered material, from an ergodic liquid-like arrangement of particles to a nonergodic soft glassy-like solid, occurs below ~40 °C, coincident with the temperature associated with the formation of the DDQC. We speculate that this stiffening reflects the development of particle clusters with local tetrahedral or icosahedral symmetry that seed growth of the temporally transient DDQC state. Here, this work highlights extraordinary opportunities to uncover the origins and stability of aperiodic order in condensed matter using model block polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SIGNIFICANT X-RAY LINE EMISSION IN THE 5-6 keV BAND OF NGC 4051

A Suzaku X-ray observation of NGC 4051 taken during 2005 November reveals line emission at 5.44 keV in the rest frame of the galaxy which does not have an obvious origin in known rest-frame atomic transitions. The improvement to the fit statistic when this line is accounted for establishes its reality at >99.9% confidence: we have also verified that the line is detected in the three X-ray Imaging Spectrometer units independently. Comparison between the data and Monte Carlo simulations shows that the probability of the line being a statistical fluctuation is p < 3.3 x 10{sup -4}. Consideration of three independent line detections in Suzaku data taken at different epochs yields a probability p < 3 x 10{sup -11} and thus conclusively demonstrates that it cannot be a statistical fluctuation in the data. The new line and a strong component of Fe Kalpha emission from neutral material are prominent when the source flux is low, during 2005. Spectra from 2008 show evidence for a line consistent with having the same flux and energy as that observed during 2005, but inconsistent with having a constant equivalent width against the observed continuum. The stability of the line flux and energy suggests that it may not arise in transient hotspots, as has been suggested for similar lines in other sources, but could arise from a special location in the reprocessor, such as the inner edge of the accretion disk. Alternatively, the line energy may be explained by spallation of Fe into Cr, as discussed in a companion paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-Dependent Light-Stabilized States in Thin-Film PV Modules: Preprint

Thin-film photovoltaic modules are known to exhibit light-induced transient behavior which interferes with accurate and repeatable measurements of power. Typically power measurements are made after a light exposure in order to target a 'light state' of the module that is representative of outdoor performance. Here we show that the concept of a unique light state is poorly defined for both CIGS and CdTe modules. Instead we find that their metastable state after a light exposure can depend on the temperature of the module during the exposure. We observe changes in power as large as 5.8% for a 20 degrees C difference in light exposure temperature. These results lead us to conclude that for applications in which reproducibility and repeatability are critical, module temperature should be tightly controlled during light exposure.

14 SOLAR ENERGY↗

DQ Admittance Model Extraction for IBRs via Gaussian Pulse Excitation

While $dq$ admittance models have shown to be very useful for stability analysis, extracting admittance models of inverter-based resources (IBRs) from the electromagnetic transient (EMT) simulation environment using frequency scans takes time. In this letter, a new perturbation method based on Gaussian pulses in combination with the system identification algorithms shows great promise for parametric $dq$ admittance model extraction. We present the $dq$ admittance model extracting method for a type-4 wind turbine. Challenges in implementing Gaussian pulse excitation are also pointed out. In conclusion, the extracted $dq$ admittance model via the new method shows to have a high matching degree with the measurements obtained from frequency scans.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Flow Modeling under Thermal Fluidics Considerations within Operational Domains of Molten Salt Reactors

Molten Salt Reactors (MSRs) offer significant versatility supported by their design flexibility and safety advantages due to high temperatures, design customization capabilities, strong negative reactivity feedback effects, and salt chemistry characteristics. Different control schedules and different mass flow rates in the MSR primary systems impact neutronics and thermal hydraulics coupling. The result is two-fold. First, it leads to adaptability in various applications when the customization of a MSR unit is desired. Second, it calls for the quantification of dynamics and safety characteristics to assess the operational domain and make sure reactor stability and inherent safety characteristics are maintained. This paper provides an in-depth transient analysis of the operational implications of MSRs having heat-generating fuel and heat-transporting salt mixed forming liquid fuel salts contained within primary systems. A coupling model was developed to simulate fuel flow in molten salt reactors. A zero-dimensional reactor kinetics model was used with a one-dimensional heat transfer model in the reactor core. The temperature reactivity feedbacks of the fuel salt resulting from the thermal-hydraulics model were used in the reactor kinetics model to complete the coupled code. The model was applied to simulate the Molten Salt Breeder Reactor (MSBR) response at steady state and transients. The developed model was shown to be a suitable tool for the dynamic analysis of molten salt reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Distributed Barrier Certificates for Safe Operation of Inverter-Based Microgrids

Inverter-interfaced microgrids differ from the traditional power systems due to their lack of inertia. Vanishing timescale separation between voltage and frequency dynamics makes it critical that faster-timescale stabilizing control laws also guarantee by-construction the satisfaction of voltage limits during transients. In this article, we apply a barrier functions method to compute distributed active and reactive power setpoint control laws that certify satisfaction of voltage limits during transients. Using sum-of-squares optimization tools, we propose an algorithmic construction of these control laws. Numerical simulations are provided to illustrate the proposed method.

Kundu, Soumya↗

Influence of dynamic inflow on the helicopter vertical response

A study was conducted to investigate the effects of dynamic inflow on rotor-blade flapping and vertical motion of the helicopter in hover. Linearized versions of two dynamic inflow models, one developed by Carpenter and Fridovich and the other by Pitt and Peters, were incorporated in simplified rotor-body models and were compared for variations in thrust coefficient and the blade Lock number. In addition, a comparison was made between the results of the linear analysis, and the transient and frequency responses measured in flight on the CH-47B variable-stability helicopter. Results indicate that the correlations are good, considering the simplified model used. The linear analysis also shows that dynamic inflow plays a key role in destabilizing the flapping mode. The destabilized flapping mode, along with the inflow mode that the dynamic inflow introduces, results in a large initial overshoot in the vertical acceleration response to an abrupt input in the collective pitch. This overshoot becomes more pronounced as either the thrust coefficient or the blade Lock number is reduced. Compared with Carpenter's inflow model, Pitt's model tends to produce more oscillatory responses because of the less stable flapping mode predicted by it.

Chen, Robert T. N.↗

Influence of dynamic inflow on the helicopter vertical response

A study has been conducted to investigate the effects of dynamic inflow on rotor-blade flapping and vertical motion of the helicopter in hover. Linearized versions of two dynamic inflow models, one developed by Carpenter and Fridovich and the other by Pitt and Peters, were incorporated in simplified rotor-body models and were compared for variations in thrust coefficient and the blade Lock number. In addition, a comparison was made between the results of the linear analysis, and the transient and frequency responses measured in flight on the CH-47B variable-stability helicopter. Results indicate that the correlations are good, considering the simplified model used. The linear analysis also shows that dynamic inflow plays a key role in destabilizing the flapping mode. The destabilized flapping mode, along with the inflow mode that the dynamic inflow introduces, results in a large initial overshoot in the vertical acceleration response to an abrupt input in the collective pitch. This overshoot becomes more pronounced as either the thrust coefficient or the blade Lock number is reduced. Compared with Carpenter's inflow model, Pitt's model tends to produce more oscillatory responses because of the less stable flapping mode predicted by it.

Chen, Robert T. N.↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Maui PSCAD Model: Motivation, Methodology, and Lessons Learned: Preprint

As power systems become increasingly dependent on inverter-based resources, the dominant physical and control interactions that determine system stability may no longer be accurately captured in positive sequence dynamic simulation tools; electromagnetic transient (EMT) simulations may be needed. This paper describes the process of creating and validating an EMT model of the entire Maui island transmission system in PSCAD software. The model is validated against the utility's PSSE model and against field data for an event that consisted of a single-phase fault followed by a generation trip. The methodology and lessons learned are summarized here.

41 EE - Solar Energy Technologies Office (EE-4S)↗

DAC-3 Pointing Stability Analysis Results for SAGE 3 and Other Users of the International Space Station (ISS) Payload Attachment Sites (PAS)

The purpose of this paper is to provide final results of a pointing stability analysis for external payload attachment sites (PAS) on the International Space Station (ISS). As a specific example, the pointing stability requirement of the SAGE III atmospheric science instrument was examined in this paper. The instrument requires 10 arcsec stability over 2 second periods. SAGE 3 will be mounted on the ISS starboard side at the lower, outboard FIAS. In this engineering analysis, an open-loop DAC-3 finite element model of ISS was used by the Microgravity Group at Johnson Space Flight Center to generate transient responses at PAS to a limited number of disturbances. The model included dynamics up to 50 Hz. Disturbance models considered included operation of the solar array rotary joints, thermal radiator rotary joints, and control moment gyros. Responses were filtered to model the anticipated vibration attenuation effects of active control systems on the solar and thermal radiator rotary joints. A pointing stability analysis was conducted by double integrating acceleration transient over a 2 second period. Results of the analysis are tabulated for ISS X, Y, and Z Axis rotations. These results indicate that the largest excursions in rotation during pointing occurred due to rapid slewing of the thermal radiator. Even without attenuation at the rotary joints, the resulting pointing error was limited to less than 1.6 arcsec. With vibration control at the joints, to a maximum 0.5 arcsec over a 2 second period. Based on this current level of model definition, it was concluded that between 0 - 50 Hz, the pointing stability requirement for SAGE 3 will not be exceeded by the disturbances evaluated in this study.

Woods-Vedeler, Jessica A.↗