Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vertical Motion Simulator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

726 records · Page 41

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood↗

Measurment and Interpretation of Seismic Attenuation for Hydrocarbon Exploration

This research project is the combined effort of several leading research groups. Advanced theoretical work is being conducted at the Lawrence Berkeley National Laboratory. Here, the fundamental controls on loss mechanisms are being examined, primarily by use of numerical models of heterogeneous porous media. At the University of California, Berkeley, forward modeling is combined with direct measurement of attenuation. This forward modeling provides an estimate of the influence of 1/Q on the observed seismic signature. Direct measures of losses in Vertical Seismic Profiles (VSPs) indicate mechanisms to separate scattering versus intrinsic losses. At the Colorado School of Mines, low frequency attenuation measurements are combined with geologic models of deep water sands. ChevronTexaco is our corporate cosponsor and research partner. This corporation is providing field data over the Genesis Field, Gulf of Mexico. In addition, ChevronTexaco has rebuilt and improved their low frequency measurement system. Soft samples representative of the Genesis Field can now be measured for velocities and attenuations under reservoir conditions. Throughout this project we have: Assessed the contribution of mechanical compaction on time-lapse monitoring; Developed and tested finite difference code to model dispersion and attenuation; Heterogeneous porous materials were modeled and 1/Q calculated vs. frequency; 'Self-affine' heterogeneous materials with differing Hurst exponent modeled; Laboratory confirmation was made of meso-scale fluid motion influence on 1/Q; Confirmed theory and magnitude of layer-based scattering attenuation at Genesis and at a shallow site in California; Scattering Q's of between 40 and 80 were obtained; Measured very low intrinsic Q's (2-20) in a partially saturated vadose zone VSP; First field study to separate scattering and intrinsic attenuation in real data set; Revitalized low frequency device at ChevronTexaco's Richmond lab completed; First complete frequency dependent measurements on Berea sandstones from dry to various saturations (brine and decane); Frequency dependent forward modeling code is running, and tested on a couple of Cases--derives frequency dependent reflectivity from porosity based logs; Genesis seismic data obtained but is on hold until forward modeling is complete; Boundary and end effects modeled for soft material measurements at CSM; and Numerous papers published or submitted and presentations made.

58 GEOSCIENCES↗

Modeling the spatiotemporal organization of velocity storage in the vestibuloocular reflex by optokinetic studies

1. A generalized three-dimensional state space model of visual vestibular interaction was developed. Matrix and dynamical system operators associated with inputs from the semicircular canals, otolith velocity estimator, and the visual system have been incorporated into the model, which focus on their relationship to the velocity storage integrator. 2. A relationship was postulated between the eigenvalues and the direction of the eigenvectors of the system matrix and the orientation of the spatial vertical. It was assumed that the system matrix for a tilted position was a composition of two linear transformations of the system matrix for the upright position. One transformation modifies the eigenvalues of the system matrix, whereas another rotates the eigenvectors of the system matrix. The pitch and roll eigenvectors rotate with the head, whereas the yaw axis eigenvector remains approximately spatially invariant. 3. Based on the three-dimensional model, a computational procedure was formulated to identify the eigenvalues and eigenvectors of the system matrix with the use of a modification of the marquardt algorithm. With the use of data obtained from a monkey, it was shown that the three-dimensional behavior of velocity storage cannot be predicted solely in terms of its time constants, i.e., the inverse of its eigenvalues. With the use of the same eigenvalues the data could either be fit or not fit, depending on the eigenvector directions. Therefore, it is necessary to specify eigenvector directions when characterizing velocity storage in three dimensions. 4. Parameters found with the use of the Marquardt algorithm were incorporated into the model. Diagonal matrices in a head coordinate frame were introduced for coupling the visual system to the integrator and to the direct optokinetic pathway. Simulations of optokinetic nystagmus (OKN) and optokinetic after-nystagmus (OKAN) were run. The model predicted the behavior of yaw and pitch OKN and OKAN when the animal is upright. It also predicted the cross-coupling in the side down position. The trajectories in velocity space were also accurately simulated. 5. One of the predictions of the model is that when the stimulus direction is along an eigenvector, the trajectory in velocity space is a straight line. Using the "spectral width" of the residuals from a straight line sequence during OKAN, we developed a methodology to estimate how close the OKAN decay was to an eigenvector trajectory. 6. Thus we have developed a model-based approach for studying and interpreting the response characteristics of velocity storage in three dimensions.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Betatron motion with coupling of horizontal and vertical degrees of freedom

Presently, there are two most frequently used parameterezations of linear x-y coupled motion used in the accelerator physics. They are the Edwards-Teng and Mais-Ripken parameterizations. The article is devoted to an analysis of close relationship between the two representations, thus adding a clarity to their physical meaning. It also discusses the relationship between the eigen-vectors, the beta-functions, second order moments and the bilinear form representing the particle ellipsoid in the 4D phase space. Then, it consideres a further development of Mais-Ripken parameteresation where the particle motion is descrabed by 10 parameters: four beta-functions, four alpha-functions and two betatron phase advances. In comparison with Edwards-Teng parameterization the chosen parametrization has an advantage that it works equally well for analysis of coupled betatron motion in circular accelerators and in transfer lines. In addition, considered relationship between second order moments, eigen-vectors and beta-functions can be useful in interpreting tracking results and experimental data. As an example, the developed formalizm is applied to the FNAL electron cooler and Derbenev’s vertex-to-plane adapter.

43 PARTICLE ACCELERATORS↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

Photospheric Current Spikes and Their Possible Association with Flares - Results from an HMI Data Driven Model

A data driven, near photospheric magnetohydrodynamic model predicts spikes in the horizontal current density, and associated resistive heating rate per unit volume Q. The spikes appear as increases by orders of magnitude above background values in neutral line regions (NLRs) of active regions (ARs). The largest spikes typically occur a few hours to a few days prior to M or X flares. The spikes correspond to large vertical derivatives of the horizontal magnetic field. The model takes as input the photospheric magnetic field observed by the Helioseismic & Magnetic Imager (HMI) on the Solar Dynamics Observatory (SDO) satellite. This 2.5 D field is used to determine an analytic expression for a 3 D magnetic field, from which the current density, vector potential, and electric field are computed in every AR pixel for 14 ARs. The field is not assumed to be force-free. The spurious 6, 12, and 24 hour Doppler periods due to SDO orbital motion are filtered out of the time series of the HMI magnetic field for each pixel using a band pass filter. The subset of spikes analyzed at the pixel level are found to occur on HMI and granulation scales of 1 arcsec and 12 minutes. Spikes are found in ARs with and without M or X flares, and outside as well as inside NLRs, but the largest spikes are localized in the NLRs of ARs with M or X flares. The energy to drive the heating associated with the largest current spikes comes from bulk flow kinetic energy, not the electromagnetic field, and the current density is highly non-force free. The results suggest that, in combination with the model, HMI is revealing strong, convection driven, non-force free heating events on granulation scales, and that it is plausible these events are correlated with subsequent M or X flares. More and longer time series need to be analyzed to determine if such a correlation exists. Above an AR dependent threshold value of Q, the number of events N(Q) with heating rates greater than or equal to Q obeys a scale invariant power law distribution for each AR given by N(Q) varies Q(sup -s), where 0.40 less than or equal to S less than or equal to 0.53, with a mean and standard deviation across the 14 ARs of 0.47 and 0.045, showing there is little variation of S from one AR to another. These properties of N(Q) are in close agreement with those of the distribution N(E) for the total energy E of solar flares, determined from observations to be N(E) = constant x E(sup -alpha). From observations of nanoflares in the 0.7 to 4 MK range, and from observations of flares in hard X-rays, it is found that 0.51 less than or equal to alpha less than or equal to 0.57, and 0.4 less than or equal to alpha less than or equal to 0.6, respectively (Crosby et al. 1993, Sol. Phys., 143, 275; Aschwanden & Parnell 2002, ApJ, 572, 1048). Observations also show that, as is found here for the exponent S, there is little variation of alpha with AR (Wheatland 2000, ApJ, 532, 1209), indicating N(E) and N(Q) are largely independent of individual properties of ARs such as area, total magnetic flux, and distribution of current density (i.e. non-potentiality). Therefore the power law scaling of the photospheric heating rate Q computed here on granulation scales is essentially identical to that found for coronal observations of flare energies on scales 1-2 orders of magnitude larger. This suggests the physical mechanisms that cause Q and coronal flares are closely related. It seems likely that Q is the signature of a magnetic reconnection process in an energy range and volume orders of magnitude smaller than those of flares. In this context, at least the larger spikes in Q might be signatures of UV photospheric or lower chromospheric bombs in which plasma is heated to temperatures approximately 10(exp -5) K (Peter et al. 2014, Science 346, 1255726; Judge 2015, ApJ, 808, 116). In addition, lattice based avalanche simulations of flare energy release predict 0.4 less than or equal to alpha less than or equal to 0.5, while analytic, fractal-diffusive self-organized criticality models predict 0.4 less than or equal to alpha less than or equal to 0.67, in excellent agreement with observations, and the results presented here (Aschwanden & Parnell 2002, ApJ, 572, 1048; Aschwanden 2012, A&A, 539, A2; Aschwanden 2013, in "Self Organized Criticality Systems"; Aschwanden et al. 2016, SSR, 198, 47).

Goodman, Michael↗