Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Testing of the Engineering Model Electrical Power Control Unit for the Fluids and Combustion Facility

The John H. Glenn Research Center at Lewis Field (GRC) in Cleveland, OH and the Sundstrand Corporation in Rockford, IL have designed and developed an Engineering Model (EM) Electrical Power Control Unit (EPCU) for the Fluids Combustion Facility, (FCF) experiments to be flown on the International Space Station (ISS). The EPCU will be used as the power interface to the ISS power distribution system for the FCF's space experiments'test and telemetry hardware. Furthermore. it is proposed to be the common power interface for all experiments. The EPCU is a three kilowatt 12OVdc-to-28Vdc converter utilizing three independent Power Converter Units (PCUs), each rated at 1kWe (36Adc @ 28Vdc) which are paralleled and synchronized. Each converter may be fed from one of two ISS power channels. The 28Vdc loads are connected to the EPCU output via 48 solid-state and current-limiting switches, rated at 4Adc each. These switches may be paralleled to supply any given load up to the 108Adc normal operational limit of the paralleled converters. The EPCU was designed in this manner to maximize allocated-power utilization. to shed loads autonomously, to provide fault tolerance. and to provide a flexible power converter and control module to meet various ISS load demands. Tests of the EPCU in the Power Systems Facility testbed at GRC reveal that the overall converted-power efficiency, is approximately 89% with a nominal-input voltage of 12OVdc and a total load in the range of 4O% to 110% rated 28Vdc load. (The PCUs alone have an efficiency of approximately 94.5%). Furthermore, the EM unit passed all flight-qualification level (and beyond) vibration tests, passed ISS EMI (conducted, radiated. and susceptibility) requirements. successfully operated for extended periods in a thermal/vacuum chamber, was integrated with a proto-flight experiment and passed all stability and functional requirements.

Kimnach, Greg L.↗

Vibration characteristics of OH-58A helicopter main rotor transmission

Experimental vibration tests covering a range of torque and speed conditions were performed on the OH-58A helicopter main rotor transmission at the NASA Lewis Research Center. Signals from accelerometers located on the transmission housing were analyzed by using Fourier spectra, power spectral density functions, and averaging techniques. Most peaks of the Fourier spectra occurred at the spiral bevel and planetary gear mesh harmonics. The highest level of vibration occurred at the spiral bevel meshing frequency. Transmission speed and vibration measurement location had a significant effect on measured vibration; transmission torque and measurement direction had a small effect.

Lewicki, David G.↗

Design and Manufacture of a Highly Reliable, Miniaturized and Low Mass Shutter Mechanism

This paper describes the development, manufacturing and testing of a lightweight shutter mechanism made of titanium for the MERTIS Instrument. MERTIS is a thermal infrared imaging spectrometer onboard ESA's future BepiColombo mission to Mercury. The mechanism is built as a parallelogram arrangement of flexible hinges, actuated by a voice coil. In a first test run, it was shown that the selected EDM processing led to the generation of titanium oxides and an oxygen-enriched surface layer on the substrate (so called alpha-case layer). In the revised version of the shutter, it was possible to manufacture the complex geometry by micro-milling and an adjacent pickling procedure. The adequacy of this approach was verified by lifetime and vibration testing.

Manhart, M.↗

Locating Damaged Members in a Truss Structure Using Modal Test Data: a Demonstration Experiment

On-orbit assessment of large flexible space truss structures can be accomplished, in principle, with dynamic response information, structural identification methods, and model correlation techniques which produce an adjusted mathematical model. In a previously developed approach for damage location, an optimal update of the structure model is formed using the response data, then examined to locate damaged members. An experiment designed to demonstrate and verify the performance of the on-orbit assessment approach uses a laboratory scale model truss structure which exhibits characteristics expected for large space truss structures. Vibration experiments were performed to generate response data for the damaged truss. The damage location approach, analytical work performed in support of the vibration tests, the measured response of the test article, and some preliminary results are described.

Smith, Suzanne Weaver↗

Technical challenges of integrating the Space Shuttle

A review is presented of the technology involved in integrating the Space Shuttle system. A powered flight analysis of the Shuttle is presented, touching upon the following areas: ascent profile and abort mode integration, sizing and design, control of load factor by a stage thrust shaping, structural load constraints, flight performance reserve and trajectory design for the orbital flight test. A discussion is presented of aerothermodynamics including aerodynamic and plume heating. Flight control and separation is considered with attention paid to liftoff, ascent to booster staging, elevon load relief, booster tailoff thrust mismatch and gimbal limitations and booster separation. Structural analysis and dynamics is examined, considering: vehicle loads and modes and the pogo effect. Propulsion aspects (hydraulics, the LH2 recirculation system, the antigeyser system, the pressurization system, etc.), ground vibration tests, separation system verification and flight readiness firing are all described.

Martin, A. C.↗

Design and Operation of a Fast, Thin-Film Thermocouple Probe on a Turbine Engine

As a demonstration of technology maturation, a thin-film temperature sensor probe was fabricated and installed on a F117 turbofan engine via a borescope access port to monitor the temperature experienced in the bleed air passage of the compressor area during an engine checkout test run. To withstand the harsh conditions experienced in this environment, the sensor probe was built from high temperature materials. The thin-film thermocouple sensing elements were deposited by physical vapor deposition using pure metal elements, thus avoiding the inconsistencies of sputter-depositing particular percentages of materials to form standardized alloys commonly found in thermocouples. The sensor probe and assembly were subjected to a strict protocol of multi-axis vibrational testing as well as elevated temperature pressure testing to be qualified for this application. The thin-film thermocouple probe demonstrated a faster response than a traditional embedded thermocouple during the engine checkout run.

thermocouples↗

Assessment of Proper Bonding Methods and Mechanical Characterization FPGA CQFPs

This presentation discusses fractured leads on field-programmable gate array (FPGA) during flight vibration. Actions taken to determine root cause and resolution of the failure include finite element analysis (FEA) and vibration testing and scanning electron microscopy (with X-ray microanalysis) and energy dispersive spectrometry (SEM/EDS) failure assessment. Bonding methods for surface mount parts is assessed, including critical analysis and assessment of random fatigue damage. Regarding ceramic quad flat pack (CQFP) lead fracture, after disassembling the attitude control electronics (ACE) configuration, photographs showed six leads cracked on FPGA RTSX72SU-1 CQ208B package located on the RWIC card. An identical package (FPGA RTSX32SU-1 CQ208B) mounted on the RWIC did not results in cracked pins due to vibration. FPGA lead failure theories include workmanship issues in the lead-forming, material defect in the leads of the FPGA packages, and the insecure mounting of the board in the card guides, among other theories. Studies were conducted using simple calculations to determine the response and fatigue life of the package. Shorter packages exhibited more response when loaded by out-of-plane displacement of PCB while taller packages exhibit more response when loaded by in-plane acceleration of PCB. Additionally, under-fill did not contribute to reducing stress in leads due to out-of-plane PCB loading or from component twisting, as much as corner bonding. The combination of corner bond and under-fill is best to address mechanical and thermal S/C environment. Test results of bonded parts showed reduced (dampened) amplitude and slightly shifted peaks at the un-bonded natural frequency and an additional response at the bonded frequency. Stress due to PCBB out-of-plane loading was decreased on in the corners when only a corner bond was used. Future work may address CQFP fatigue assessment, including the investigation of discrepancy in predicted fatigue damage, as well as comparing fatigue life and fatigue damage cycle ration computed using FEA and Miner's rule to results from a fatigue assessment software program.

Davis, Milton C.↗

Dynamic testing and analysis of extension-twist-coupled composite tubular spars

The results from a study aimed at improving the dynamic and aerodynamic characteristics of composite rotor blades through the use of extension-twist elastic coupling are presented. A set of extension-twist-coupled composite tubular spars, representative of the primary load carrying structure within a helicopter rotor blade, was manufactured using four plies of woven graphite/epoxy cloth 'prepreg.' These spars were non-circular in cross section design and were therefore subject to warping deformations. Three cross-sectional geometries were developed: square, D-shape, and flattened ellipse. Results from free-free vibration tests of the spars were compared with results from normal modes and frequency analyses of companion shell-finite-element models developed in MSC/NASTRAN. Five global or 'non-shell' modes were identified within the 0-2000 Hz range for each spar. The frequencies and associated mode shapes for the D-shape spar were correlated with analytical results, showing agreement within 13.8 percent. Frequencies corresponding to the five global mode shapes for the square spar agreed within 9.5 percent of the analytical results. Five global modes were similarly identified for the elliptical spar and agreed within 4.9 percent of the respective analytical results.

Lake, Renee C.↗

Structural dynamic model obtained from flight use with piloted simulation and handling qualities analysis

The ability to use flight data to determine an aircraft model with structural dynamic effects suitable for piloted simulation. and handling qualities analysis has been developed. This technique was demonstrated using SR-71 flight test data. For the SR-71 aircraft, the most significant structural response is the longitudinal first-bending mode. This mode was modeled as a second-order system, and the other higher order modes were modeled as a time delay. The distribution of the modal response at various fuselage locations was developed using a uniform beam solution, which can be calibrated using flight data. This approach was compared to the mode shape obtained from the ground vibration test, and the general form of the uniform beam solution was found to be a good representation of the mode shape in the areas of interest. To calibrate the solution, pitch-rate and normal-acceleration instrumentation is required for at least two locations. With the resulting structural model incorporated into the simulation, a good representation of the flight characteristics was provided for handling qualities analysis and piloted simulation.

Powers, Bruce G.↗

Simulating the Dynamics of the CX-100 Wind Turbine Blade: Model Selection Using a Robustness Criterion

Several plausible modeling strategies are available to develop finite element (FE) models of ever-increasingly complex phenomena. Expert judgment is typically used to choose which strategy to employ, while the “best” modeling approach remains unknown. This paper proposes a decision analysis framework that offers a systematic and rigorous methodology for comparing plausible modeling strategies. The proposed framework departs from the conventional approach that considers only test-analysis correlation to select the model that provides the highest degree of fidelity-to-data. The novelty of the framework lies in an exploration of the trade-offs between robustness to uncertainty and fidelity-to-data. Exploring robustness to model imprecision and inexactness, in addition to fidelity-to-data, lends credibility to the simulation by guaranteeing that its predictions can be trusted even if some of the modeling assumptions and input parameters are incorrect. To demonstrate this approach, an experimental configuration is analyzed in which large masses are used to load the CX-100 wind turbine blade in bending during vibration testing. Two plausible simulations are developed with differing strategies to implement these large masses using (i) a combination of point-mass and spring elements or (ii) solid elements. In this paper, the authors study the ability of the two FE models to predict the experimentally obtained natural frequencies, and the robustness of these competing models to uncertainties in the input parameters. Considering robustness for model selection provides the extent to which prediction accuracy deteriorates as the lack-of-knowledge increases. Therefore, the preferable modeling strategy is the one that offers the best compromise between fidelity-to-data and robustness to uncertainty. To predict the bending vibration of the CX-100 wind turbine blade, it is observed that the modeling strategy with solid elements is far superior to the other one in its ability to provide a compromise between fidelity-to-data and robustness to the modeling assumptions. (Approved for unlimited, public release on October xx, 2012, LA-UR-12-xxxx, Unclassified.)

17 WIND ENERGY↗

Acoustically Induced Vibration of Structures: Reverberant Vs. Direct Acoustic Testing

Large reverberant chambers have been used for several decades in the aerospace industry to test larger structures such as solar arrays and reflectors to qualify and to detect faults in the design and fabrication of spacecraft and satellites. In the past decade some companies have begun using direct near field acoustic testing, employing speakers, for qualifying larger structures. A limited test data set obtained from recent acoustic tests of the same hardware exposed to both direct and reverberant acoustic field testing has indicated some differences in the resulting structural responses. In reverberant acoustic testing, higher vibration responses were observed at lower frequencies when compared with the direct acoustic testing. In the case of direct near field acoustic testing higher vibration responses appeared to occur at higher frequencies as well. In reverberant chamber testing and direct acoustic testing, standing acoustic modes of the reverberant chamber or the speakers and spacecraft parallel surfaces can strongly couple with the fundamental structural modes of the test hardware. In this paper data from recent acoustic testing of flight hardware, that yielded evidence of acoustic standing wave coupling with structural responses, are discussed in some detail. Convincing evidence of the acoustic standing wave/structural coupling phenomenon will be discussed, citing observations from acoustic testing of a simple aluminum plate. The implications of such acoustic coupling to testing of sensitive flight hardware will be discussed. The results discussed in this paper reveal issues with over or under testing of flight hardware that could pose unanticipated structural and flight qualification issues. Therefore, it is of paramount importance to understand the structural modal coupling with standing acoustic waves that has been observed in both methods of acoustic testing. This study will assist the community to choose an appropriate testing method and test setup in the planning stages.

Reverberant acoustic field↗

Plan, formulate, and discuss a NASTRAN finite element model of the UH-60A helicopter airframe

Under a rotorcraft structural dynamics program sponsored by the NASA Langley Research Center, Sikorsky Aircraft, together with the other major helicopter airframe manufacturers, is engaged in a study to improve the use of finite element analysis to predict the dynamic behavior of helicopter airframes. This program, which was designated DAMVIBS (Design Analysis Methods for VIBrationS), includes activities in the areas of: planning, creating, and documenting finite element models of helicopter airframes; the performance of ground vibration tests; and the correlation of test and analysis. The work performed at Sikorsky Aircraft for planning, creating, and documenting a finite element model of the UH-60A BLACK HAWK helicopter airframe is summarized. A complete description of the components of the helicopter which are to be represented in the model is presented and includes: the structural arrangement, the identification of primary and secondary structure, the components of the drive and power trains, and the attachment of large weight items to the structure. Also presented are the techniques which were used to formulate the structural finite element model for static analysis, for forming the mass and vibration models for dynamic analysis, and the procedures which were used to check out and verify the integrity of the model. Initial predictions for the vibration modes for the helicopter are included.

Dinyovszky, P.↗

Stall flutter and nonlinear divergence of a two-dimensional flat plate wing

Tests were conducted in a small wind tunnel to study the torsional stall flutter behavior of a two-dimensional flat-plate wing pivoted about the midchord. The nonlinear static divergence equilibrium properties of the wing were well predicted from the measured static moment characteristics. Large amplitude limit cycles ranging from plus or minus 11 degrees to plus or minus 100 degrees were observed. Stall flutter occurred above a critical value of a reduced frequency of about 2. Self-excitation occurred for initial angles of attack between 0 and 8 degrees. Nondimensional harmonic coefficients were extracted from the free transient vibration tests for amplitudes up to 80 degrees.

Dugundji, J.↗

Ampaire ARPA-e Electric Flight Testbed

A hybrid-electric aircraft flying testbed was developed in this program with the intent to serve as a dedicated, enduring testbed to test and evaluate ARPA-e CIRCUITS Program and other electrified aviation technologies in relevant flight environments. This testbed enabled rapid development cycles of novel and innovative technologies in the electrified aviation space, maturing them from a research lab environment to flying in an aircraft. By providing research groups with the means to test their transformative technologies in a real-world, aircraft environment, the path to validating the safety and reliability of their technologies for future commercial opportunities was greatly accelerated. Three core technologies were integrated and tested: an inverter/motor drive built by the University of Arkansas, a solid-state circuit breaker (iBreaker) built by the Illinois Institute of Technology, and a Flying Capacitor Multi-level (FCML) DC/DC converter built by the University of California, Berkeley. In each of these cases, the requirements established for safety of flight resulted in a holistic approach to the designs, evoking a deeper understanding of the potential failure modes and mitigations necessary to build a robust and flightworthy system. Further, the integration into a hybrid-electric aircraft de-risked the potential electrical and mechanical issues that cannot easily be experienced or replicated in a lab environment. The experiments were also required to undergo representative temperature, shock, and vibration testing as the FAA prescribes for this category of aircraft, facilitating familiarity with the relevant design and test guidelines necessary to commercialize the technologies. This testbed unlocks the massive potential of core power electronics technologies necessary for a safe, robust, and efficient electric aviation future. With quick iterative design, test, and flight cycles, these core technologies are on a quicker path to technology readiness level maturity and commercialization, enabling a more sustainable future for the aviation industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Space qualified hybrid superconductor/semiconductor planar oscillator circuit

We report on the space qualification of a hybrid superconductor/semiconductor planar local oscillator (LO) at 8.4 GHz. This oscillator was designed, fabricated, and tested as a component for the High Temperature Superconductivity Space Experiment 2 (HTSSE-2). The LO consisted of a GaAs MESFET and microstrip circuitry patterned onto a YBa2Cu3O(7-delta) high temperature superconducting (HTS) thin film on a 1.0 x 1.0 sq cm lanthanum aluminate (LaAlO3) substrate. At 77 K, this oscillator achieved power output levels up to 10 dBm into a 50 Ohm load. When incorporated into a full cryogenic receiver, the LO provided output powers within 0.0-3.0 dBm with less than 50 mW of dc power dissipation. Space qualification data on the sensitivity of the HTS films to the processing steps involved in the fabrication of HTS-based components are presented. Data on ohmic contacts, strength of wire bonds made to such contacts, and aging effects as well as vibration test results are discussed.

Miranda, F. A.↗

Cryogenic star-tracking telescope for Gravity Probe B

This paper describes the design, development and preliminary testing of the cryogenic star-tracking telescope used as an optical reference for the gyroscopes in the Gravity Probe B Relativity Gyroscope experiment. The telescope is operated at 1.8 K; it is fabricated entirely from fused quartz components held together by optical contacting; it has a physical length of 14 in., a focal length of 150 in. and an aperture of 5.6 in. Readout is by two photomultiplier chopper-detector assemblies at ambient satellite temperature. When fully operational, the telescope may be expected to have a precision approaching 0.1 milliarcsec over a linear range of 70 + or 70 milliarcsec. Its projected noise performance corresponds to an angular resolution of 1 milliarcsec in 1 Hz bandwidth. The paper includes a theoretical analysis, a description of the design and fabrication of a laboratory version of the telescope, a discussion of techniques of optical contacting, an account of vibration tests on a separate mass model of the telescope, a description of the artificial star developed for optical tests, and an account of preliminary experimental results.

Everitt, C. W. F.↗

Measurement of damping of graphite epoxy composite materials and structural joints

The damping capacity of graphite epoxy materials and structural joints was evaluated. The damping ratio of different composite specimens and bonded joints were systematically evaluated under normal atmospheric conditions and in a vacuum environment. Free and forced vibration test methods were employed for measuring the damping ratios. The effect of edge support conditions on the damping value of a composite tube specimen was studied by using a series of experiments performed on the specimen with different edge supports. It was found that simulating a free-free boundary conditions by having no constraints at the ends gives the lowest value of the material damping of the composite. The accuracy of the estimation of the damping ratio value was improved by using a curve-fitting technique on the response data obtained through measurement. The effect of outgassing (moisture desorption) on the damping capacity was determined by measuring the damping ratio of the tube specimen in a vacuum environment before and after outgassing had occurred. The effects of high and low temperatures on the damping was also investigated by using a series of experiments on tube and beam specimens. An analytical model to study the vibrations of a bonded lap joint system was formulated. Numerical results were generated for different overlap ratios of the system. These were compared with experimental results. In order to determine the influence of bonded joints on the material damping capacity, experiments were conducted on bonded lap-jointed and double-butt-jointed specimens. These experimental results were compared with simple beam specimens with no joints.

Crocker, Malcolm J.↗

Characterization Testing of Lockheed Martin Micro1-2 Cryocoolers Optimized for 220 K Environment

The Mapping Imaging Spectrometer for Europa (MISE) Instrument on the Europa Clipper mission has baselined a Lockheed Martin high-power Micro1-2 pulse tube cryocooler operating at 135 Hz with a 220 K heat rejection temperature. This paper describes the testing and results of two Lockheed Martin Micro1-2 coolers optimized for these conditions. The thermal performance of the microcoolers was measured in vacuum for heat reject temperatures between 220 and 230 K. The coolers were operated with input powers ranging from 5 W to 40 W and drive frequency between 125 Hz and 145 Hz. The optimal drive frequency was strongly dependent on heat reject temperature. In addition, the exported forces and torques of the coolers were measured at 300 K heat rejection for input powers ranging from 5 W to 60 W and drive frequency between 120 Hz and 160 Hz. The exported forces were dependent on both piston amplitude and drive frequency. Moreover, the following were measured on one of the coolers: DC and AC magnetic fields at various locations, the off-state conductance of the pulse tube, and the effect of inclination angle of the pulse tube relative to gravity on the performance of the cooler. Finally, one of the coolers was subjected to random vibration testing.

Rodriguez, J.I.↗