Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Counter cross-flow evaporator geometries for supercritical organic Rankine cycles

With recent advancements in advanced manufacturing techniques, it is now possible to fabricate complex geometries that take advantage of well known principles of heat transfer. Therefore, unconventional configurations to enhance effectiveness beyond conventional designs can now be considered for practical application. Thermal performance and overall cost of a new design of heat exchangers in counter cross-flow configurations are studied using a simplified but accurate computational method. The new heat exchanger design was introduced and studied previously for a cross-flow configuration by Sabau et al. (2016, 2018). This new design concept uses multi-scale configurations with successive plenums for the working fluid. At the smallest scale the tubes are sized to be equal to the hydraulic entrance length of the inside fluid, in accord with constructal design. With this being said, results indicate that compared to the earlier cross-flow configuration, the counter cross-flow arrangement improves the thermal performance of the heat exchanger by as much as 17% and lowers the total cost by as much as 14%.

42 ENGINEERING↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

Using Thermodynamic Availability to Predict the Transitional Film Reynolds Number between the Droplet and Jet Modes in Falling Liquid between Horizontal Tubes

The objective of this paper is to propose and validate a model for predicting the transitional film Reynolds number between the droplet and jet modes of falling film flows. The proposed model relies on thermodynamic availability with no fitting to mode transition data. The model directly predicts the numerical values of the transitional film Reynolds numbers at different operating conditions. The results of the model are validated against 43 experimental data points from the literature, which cover 10 working fluids and a wide range of tube geometries. The accuracy of the proposed model in predicting the validation data is -on average- more than 20 % better than that of the widely used Re = a (Ga) b and Re = a (Ga) b (S/ξ) c models. The model also achieves low computation time (less than 30 seconds for the 43 validation data points). The model presented in this paper has the potential of integration with heat transfer, mass transfer, and pressure drop models for optimizing the design and operation of falling film heat and mass exchangers.

42 ENGINEERING↗

Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe

Many power generation processes feature some type of working fluid that plays a critical role in the transfer of heat throughout the system. To optimize thermal efficiencies, an accurate characterization of the temperature-dependent thermal conductivity of the fluid is needed. Herein, this study develops a time-domain Modified Transient Hot-wire Needle Probe to overcome phenomena that have impaired traditional measurement techniques when the fluid is both corrosive and at an elevated temperature. First, the physical design of the instrument is presented to demonstrate features that limit interference from corrosion, electrical conduction, and convective and radiative heat transfer. Next, a governing equation for 1D (radial) heat conduction is fully developed using the thermal quadrupoles technique. A finite-element study is performed for validation. A sensitivity analysis is done to assess the time-dependent influence of critical parameters in the governing equation for several samples. Finally, thermal conductivity measurements are presented for seven different liquid substances by fitting the thermal model to experimental data across a range of temperatures. Reference correlations are included for comparison. The sample thermal conductivity and ambient temperature of the experimental conditions range from 0.125–16.5$\frac{W}{m·K}$ and 10–400°C, respectively. The total uncertainty, comprised of both the experimental design and fitting process, of all measurements is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermohydraulic experiments on a supercritical carbon dioxide–air microtube heat exchanger

Heat exchangers are critical components in supercritical CO 2 Brayton cycles and provide necessary heat input, recovery, and dissipation. Tubular heat exchangers with unconventionally small tube sizes (tube diameters less than 5 mm) are promising components for supercritical CO 2 cycles and potentially provide excellent structural stability with wide scope of application. This paper provides essential design and fabrication guidelines for a compact shell-and-tube heat exchanger with microtubes (with an inner diameter equal to 1.75 mm). A heat exchanger test rig is used to evaluate the thermohydraulic performance of this heat exchanger with supercritical CO 2 and air as working fluids. Thermohydraulic data are reported for more than forty sets of experiments with varying Reynolds numbers for shell and tube flows. Critical performance metrics are calculated from the data and compared with predictions from a previously described numerical model. The average deviations between the experimental and model results fall within 10% for all critical metrics. This excellent agreement validates the numerical model for supercritical CO 2 heat exchanger optimization and scale-up.

42 ENGINEERING↗

Evaluation of the interaction between SiC, pre-oxidized FeCrAlMo with aluminized and pre-oxidized Fe-8Cr-2W in flowing PbLi

We report dissimilar materials interactions are a major concern when liquid metals are used as a working fluid. To simulate a dual-coolant PbLi blanket, chemical vapor deposited (CVD) SiC, pre-oxidized FeCrAlMo (APMT) and pre-oxidized aluminized coating on Fe-8Cr-2 W (F82H) specimens were exposed to flowing commercial Pb-17at.%Li with a peak temperature of 650 °C in a pre-oxidized APMT thermal convection loop (TCL) for 1000 h. Similar to prior results in static PbLi, the coated F82H showed small mass changes and limited degradation of room-temperature tensile properties. After exposure, the α-Al 2 O 3 on the surface coated F82H reacted with the PbLi to form LiAlO 2 . However, no significant Al coating loss or interdiffusion was observed. Mass transfer was observed between the APMT, TCL and the SiC specimens. Fe, Cr and Ni were dissolved into the molten flowing PbLi and transported through the TCL to react with the SiC specimens. Compared to a prior experiment with a majority of bare FeCrAl specimens that were exposed in a TCL with a peak temperature of 700 °C for 1000 h, the SiC reaction was reduced to only a few microns of carbides and silicides. Oxygen dissolved in the molten PbLi sustained the formation of an Al 2 O 3 scale on the surface of the coating and induced the formation of a thin surface SiO 2 layer on the surface of the SiC.

36 MATERIALS SCIENCE↗

The performance of additively manufactured Haynes 282 in supercritical CO 2

The use of supercritical carbon dioxide (sCO 2 ) as a working fluid is garnering interest in next generation power production systems due to the possibility of increased operational efficiencies and lower associated costs. Its implementation requires alloys with excellent high temperature strength and corrosion resistance, which makes Haynes 282® (H282) a suitable candidate. With increasing adoption of additive manufacturing (AM) in the energy industry, there is a need to investigate long-term sCO2 exposure on AM produced materials. Additively manufactured H282 (AM-H282) samples built using laser powder bed fusion in two different orientations were analyzed through imaging, gravimetric analysis, and room-temperature tensile testing before and after 1000-h exposure to CO 2 at 750 °C and 20 MPa. Performed imaging included observation of the sample surfaces and of the material bulk (cross sections) through means of Scanning Electron Microscopy (SEM) and optical microscopy. In comparison to wrought H282, it was found that the exposed material exhibited a similar Cr 2 O 3 oxide protective layer about 2 μm in thickness with additional top-surface TiO 2 oxide and carbon-rich precipitates. It was also similarly observed that internal oxidation was present but limited to a depth of 20 μm, and a 1–3 μm γ’ denuded region appeared to surround all internal and surface oxidation. Thermal aging effects were noted with the precipitation of needle-like structures in the γ/γ’ matrix and a coarsening of the γ’ precipitates from 28 nm to 73 nm. Mass measurements analyzing oxide precipitation revealed a larger increase compared to wrought, representing an approximate 20% difference. Tensile testing results showed similar behavior to wrought with a slight increase in yield strength and a large reduction in elongation in the exposed samples.

36 MATERIALS SCIENCE↗

A novel approach for critical heat flux enhancement during severe accident mitigation with removal of radioactive materials from the coolant

In this paper, a new system, which consists of mature and proven technologies, is suggested for simultaneous objectives in nuclear power plants: CHF enhancement and effective decontamination. It consists of multifunctional magnetic nanoparticles and a collector part. CHF enhancement for severe accident mitigation strategies like IVR-ERVC and core catcher is expected along with an efficient decontamination process of target radioactive nuclides, and through the collector part, where external magnetic fields are applied, working fluid can be effectively purified. The multifunctional magnetic nanoparticle possesses potentials to severe accident scenarios based on its distinct characteristics. Also, a nanofluid system is strongly affected by environments and state of the immersed particles; the CHF enhancement can be stably achieved in real applications with proper consideration and optimization.

Kam, Dong Hoon↗

The liquid-conduction, vapor-flow heat pipe model in Sockeye

A single-phase heat pipe flow model implemented in the heat pipe application Sockeye is described. This model solves one-dimensional, compressible flow equations for the vapor phase in the center of a heat pipe, which are coupled to the two-dimensional heat conduction equation for the wick, liquid, and cladding, as well as to an ordinary differential equation tracking the working fluid inventory in the evaporator section of the heat pipe. This model is demonstrated with several test problems, including comparisons to analytic solutions for the vapor flow fields, analytic curves for sonic and capillary limitations of heat pipe operation, and some experimental data. The numerical solution gives excellent agreement for verification problems and good agreement with experimental results. Also, demonstrations show that the model is very robust, allowing for full simulations of heat pipe transients, including frozen startup, sonic-limited (supersonic) flow, and heat pipe shutdown.

42 ENGINEERING↗

Geostrophic to magnetically-damped turbulence in liquid metal rotating magnetoconvection

Understanding planetary core convection dynamics requires the study of convective flows in which the Coriolis and Lorentz forces attain a leading-order, so-called magnetostrophic balance. Experimental investigations of rotating magnetoconvection (RMC) in the magnetostrophic regime are therefore essential to broadly characterize the properties of local-scale planetary core flow. Toward this end, we present here the first thermovelocimetric measurements of magnetostrophic, liquid metal convection, which are made using liquid gallium as the working fluid, at moderate rotation rates (Ekman numbers 10 -4 ≤ Ek ≤ 10 -5 ) and in the presence of dynamically strong magnetic fields (Elsasser number Λ = 1). Complementary rotating convection (RC) experiments are performed at the same rotation rates to serve as reference cases. Our RMC velocity measurements adequately follow a geostrophic turbulent scaling for cases in which local-scale convective inertial forces exceed the Lorentz forces in the fluid bulk. In cases where Lorentz forces exceed local-scale inertia (local or convective interaction parameter N ℓ or N C ≳ 3), the root-mean-square RMC velocities are magnetically damped, yielding values below the geostrophic turbulent RC scaling prediction. An enhancement in heat transfer is observed, which we attribute to the increased coherence of vertically aligned magnetostrophic convective flow. Finally, our results and comparisons to dynamo simulations suggest that the system is in the strong-field regime, where convection-scale flows are magnetically damped with N C ≳ 3).

Convective turbulence↗

Shock tube/laser absorption measurement of the rate constant of the reaction: H 2 O 2 + CO 2 2OH + CO 2

We address the role of the linear mixing rule in the kinetics of the H 2 O 2 decomposition system by reporting the rate constant for H 2 O 2 + M = 2OH + M (M = Ar and CO 2 ) in the temperature range of 1087-1234 K at low pressures in a mixture of 20% CO 2 in Argon. The reaction rate constant was inferred from H 2 O concentrations monitored by using a laser-absorption spectroscopy-based water diagnostic. To the best of our knowledge, this is the first measurement of the rate constant of this reaction in a mixture to be reported in literature. A significant discrepancy was found between the rate constants derived using the traditional linear mixing rule and the reduced pressure linear mixing rule. Furthermore, this discrepancy can have serious implications on the predictive accuracy of these kinetic models, especially under conditions relevant to the operation of supercritical CO 2 (sCO 2 ) power cycles that rely on oxy-fuel combustion in a working fluid comprised almost entirely of CO 2 .

20 FOSSIL-FUELED POWER PLANTS↗

Review of heat transfer enhancement techniques in two-phase flows for highly efficient and sustainable cooling

We show that two-phase internal flow is ubiquitous to many systems due to its ability to transfer large amounts of heat effectively. Recent advances motivated by sustainability have pushed towards augmenting the heat transfer between the tube and the two-phase working fluid. Augmenting heat transfer in two-phase flows enables process intensification, and compactness leading to reduced cost and material consumption. This review investigates the effect of heat transfer enhancement techniques on different fluids including R134a, R407C, R22, etc … The techniques are categorized into passive and active and focus on durable enhancement methods which do not include surface structuring or coating. Passive techniques utilize geometrical and surface modifications to induce better mixing. Several passive techniques are analyzed including fins, inserts, and more. In analyzing these techniques, the effect of changing geometric parameters is studied, and the limitations are highlighted. Further, active techniques that enable heat transfer enhancement through applying power are also investigated. Electrohydrodynamic approaches are analyzed and compared to passive techniques. Additionally, the implications of heat exchange enhancement in the context of global energy are discussed. An energy analysis discretized by the use sector is conducted, with an emphasis on predicting the future potential for renewable and sustainable development. Moreover, although active approaches provide the highest heat transfer enhancement, due to implementation difficulties, passive techniques are more frequently adopted. The review ends with discussion of next-generation heat exchangers which will rely more on additive manufacturing due to its flexibility and reduced cost per part as the technology matures.

Nusselt number↗

Performance prediction of refrigerant-DMF solutions in a single-stage solar-powered absorption refrigeration system at low generating temperatures

A theoretical analysis of the coefficient of performance was undertaken to examine the efficiency characteristics of R22 + DMF, R134a + DMF, R32 + DMF as working fluids, respectively, for a single-stage and intermittent absorption refrigerator which allows the use of heat pipe evacuated tubular collectors. The modeling and simulation of the performance considers both solar collector system and the absorption cooling system. The typical meteorological year file containing the weather parameters for Hangzhou is used to simulate the system. The results show that the system is in phase with the weather. In order to increase the reliability of the system, a hot water storage tank is essential. The optimum ratio of storage tank per solar collector area for Hangzhou's climate for a 1.0 kW system is 0.035-0.043L. Considering the relative low pressure and the high coefficient of performance, R134a + DMF mixture presents interesting properties for its application in solar absorption cycles at moderate condensing and absorbing temperatures when the evaporating temperatures in the range from 278 K to 288 K which are highly useful for food preservation and for air-conditioning in rural areas. (author)

14 SOLAR ENERGY↗

A combined power and ejector refrigeration cycle for low temperature heat sources

A combined power and ejector refrigeration cycle for low temperature heat sources is under investigation in this paper. The proposed cycle combines the organic Rankine cycle and the ejector refrigeration cycle. The ejector is driven by the exhausts from the turbine to produce power and refrigeration simultaneously. A simulation was carried out to analyze the cycle performance using R245fa as the working fluid. A thermal efficiency of 34.1%, an effective efficiency of 18.7% and an exergy efficiency of 56.8% can be obtained at a generating temperature of 395 K, a condensing temperature of 298 K and an evaporating temperature of 280 K. Simulation results show that the proposed cycle has a big potential to produce refrigeration and most exergy losses take place in the ejector. (author)

42 ENGINEERING↗

Simulation of thermal hydraulic performance of multiple parallel micropin arrays for concentrating solar thermal applications with supercritical carbon dioxide

Concentrated solar power (CSP) plants have the potential to provide 24 h, renewable electricity. Current CSP systems have high capital and operational costs which makes the levelized cost of electricity uncompetitive with conventional techniques. Recent experimental research has shown the potential of small unit cells (up to 2 × 2 cm) containing micropin arrays (D H < 1 mm) to operate efficiently at high incident flux (>140 W cm -2 ) using supercritical carbon dioxide as the working fluid. Applying this technology to CSP systems would result in a smaller central receiver, which would reduce thermal losses, increase receiver efficiency and reduce the capital cost of the receiver component. This study investigates and addresses the practical thermal and hydraulic issues in numbering up these small unit cells into numerous parallel cells within an integrated module design. A thermal hydraulic network model is developed to quantify the distribution and the overall receiver efficiency of an integrated module. This model is used to specify maximum allowable unit cell size and header dimensions to maintain acceptable thermal performance and pressure loss. Once a module design was finalized, parametric studies were performed to study the effects of varying incident flux on flow distribution and thermal performance of the module. Finally, the results show that an integrated module design can be achieved with less than 5% flow maldistribution and a pressure drop acceptable to the remainder of the system.

14 SOLAR ENERGY↗