Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

High-energy gamma-ray and hard X-ray observations of Cyg X-3

COS-B viewed the Cyg X-3 region seven times between November, 1975, and February, 1982; a search for steady gamma-ray emission pulsed at the characteristic 4.8-hour period did not reveal its source. Leiden-MIT balloon experiment observations of Cyg X-3 in May, 1979 show the 4.8-hour modulation with sinusoidal light curve and modulation depth of 0.30, for energies of up to about 140 keV. The strong variability of Cyg X-3 over more than one order of magnitude at energies below 20 keV does not emerge in the data collected at hard X-ray energies.

Hermsen, W.↗

Correlating dynamic microstructure to observed color in electrophoretic displays via in situ small-angle x-ray scattering

Electrophoretic deposition (EPD) is an industrially relevant and scalable technique used to form particle deposits from colloidal suspensions. Highly concentrated particle suspensions generally prevent real-time in situ microscopy observations which limit the characterization of EPD films to ex situ, or postprocessed, laboratory techniques. For dynamic systems, such as tunable amorphous photonic crystals (APCs), only reversible deposits are formed during the EPD process. Since reversible deposits cannot be characterized with standard ex situ methods, the particle-particle and particle-field interactions that govern the displayed color and crystallinity of these systems are not well understood. In this paper, we present in situ small-angle x-ray scattering and UV-Vis techniques for measuring both the structural and optical response of an APC under applied electric fields. Furthermore, we also develop a computational model based on colloidal interactions to explain the observed change in the interparticle spacing of APCs due to the applied electric field which correlates to displayed color. Ultimately, this work provides a new in situ characterization method that could be expanded for other dynamic, tunable colloidal systems.

36 MATERIALS SCIENCE↗

X-ray and gamma ray astronomy detectors

X-ray and gamma ray astronomy was made possible by the advent of space flight. Discovery and early observations of celestial x-rays and gamma rays, dating back almost 40 years, were first done with high altitude rockets, followed by Earth-orbiting satellites> once it became possible to carry detectors above the Earth's atmosphere, a new view of the universe in the high-energy part of the electromagnetic spectrum evolved. Many of the detector concepts used for x-ray and gamma ray astronomy were derived from radiation measuring instruments used in atomic physics, nuclear physics, and other fields. However, these instruments, when used in x-ray and gamma ray astronomy, have to meet unique and demanding requirements related to their operation in space and the need to detect and measure extremely weak radiation fluxes from celestial x-ray and gamma ray sources. Their design for x-ray and gamma ray astronomy has, therefore, become a rather specialized and rapidly advancing field in which improved sensitivity, higher energy and spatial resolution, wider spectral coverage, and enhanced imaging capabilities are all sought. This text is intended as an introduction to x-ray and gamma ray astronomy instruments. It provides an overview of detector design and technology and is aimed at scientists, engineers, and technical personnel and managers associated with this field. The discussion is limited to basic principles and design concepts and provides examples of applications in past, present, and future space flight missions.

Decher, Rudolf↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Energetic Electrons in Solar Flares - As Viewed in X-Rays

Hard X-ray observations provide the most direct diagnostic we have of the suprathermal electrons and the hottest thermal plasma present in solar flares. The Ramaty High Energy Solar Spectroscopic Imager (RHESSI) is obtaining the most comprehensive observations of individual solar flares ever available in hard X-rays. For the first time, high-resolution spectra are available for a large number of flares that accurately display the spectral shape and its evolution and, in many cases, allow us to identify the transition from the bremsstrahlung X-rays produced by suprathermal electrons to the bremsstrahlung at lower energies emitted by thermal plasma. Also, for the first time, images can be produced in arbitrary energy bands above 3 keV, and spectra of distinct imaged components can be obtained. I will review what we have learned from RHESSI observations about flare suprathermal electron distributions and their evolution Next, I will present computations of the energy deposited by these suprathermal electrons in individual flares and compare this with the energy contained in the hot thermal plasma. I will point out unsolved problems in deducing both suprathermal electron distributions and the energy content of the thermal plasma, and discuss possible solutions. Finally, I will present evidence that electron acceleration is associated with magnetic reconnection in the corona.

Holman, Gordon D.↗

The Herbig Ae Star HD 163296 in X-Rays

Chandra X-ray imaging spectroscopy of the nearby Herbig Ae star HD 163296 at 100 AU angular resolution is reported. A point-like, soft (kT approximately 0.5 approximately kev), emission-line source is detected at the location of the star with an X-ray luminosity of 4.0e29 erg/s. In addition, faint emission along the direction of a previously-detected Ly-alpha-emitting jet and Herbig-Haro outflow may be present. The relatively low luminosity, lack of a hard spectral component, and absence of strong X-ray variability in HD 163296 can be explained as originating from optically-thin shock-heated gas accreting onto the stellar surface along magnetic field lines. This would require a (dipole) magnetic field strength at the surface of HD 163296 of at least approximately 100 approximately G and perhaps as high as several kG.

Swartz, Douglas A.↗

On stellar X-ray emission

Stellar X-ray astronomy represents an entirely new astronomical discipline which has emerged during the past five years. It lies at the crossroads of solar physics, stellar physics, and general astrophysics. The present review is concerned with the main physical problems which arise in connection with a study of the stellar X-ray data. A central issue is the extent to which the extrapolation from solar physics is justified and the definition (if possible) of the limits to such extrapolation. The observational properties of X-ray emission from stars are considered along with the solar analogy and the modeling of X-ray emission from late-type stars, the modeling of X-ray emission from early-type stars, the physics of stellar X-ray emission, stellar X-ray emission in the more general astrophysical context, and future prospects.

Rosner, R.↗

Roles of Thin Film Stress in Making Extremely Lightweight X-Ray Optics

X-ray optics typically must be coated with one of the noble metals, gold, platinum, or iridium, to enhance their photon collection area. In general, iridium is preferred to the other two because it generates the highest X-ray reflectivity in the I to 10 keV band. Unfortunately, iridium films typically have also the highest stress that can severely degrade the optical figure of the mirror substrate, resulting in a poorer image quality. In this paper we will report our work in understanding this stress and our method to counterbalance it. In particular we will also report on potential ways of using this stress to improve the substrate's optical figure, turning a bug into a desirable feature. This work is done in the context of developing an enabling technology for the International X-ray Observatory which is a collaborative mission of NASA, ESA, and JAXA, and expected to be launched into an L2 orbit in 2021.

Zhang, William W.↗

High energy X-ray and radio studies of Scorpius X-1

The results from extended high energy X-ray observations of Scorpius X-1 from the OSO 8 satellite are reported. The source was observed for a total of 15 days in 1975, 1977, and 1978. Simultaneous 10.7 GHz and 4.75 GHz radio data were obtained during the 1978 observation, and low energy X-ray data during the 1975 and 1978 observations. Detailed studies of the data reveal a lack of any correlation between the high energy X-rays and the other energy ranges. A 3 sigma upper limit of 22% was obtained for any modulation of the high energy flux with the binary period. No high energy tail was observed at any time.

Coe, M. J.↗

Coordinated X-ray and optical observations of Scorpius X-1

We present the results of coordinated, partly simultaneous, optical and X-ray (Ginga) observations of the low-mass X-ray binary Sco X-1. We find that the division between the optically bright and faint state, at a blue magnitude B = 12.8, corresponds to the change from the normal to the flaring branch in the X-ray color-color diagram as proposed by Priedhorsky et al. (1986). From archival Walraven data we find that in both optical states the orbital light curve is approximately sinusoidal, and have a similar amplitudes.

Augusteijn, T.↗

Toward Adaptive X-Ray Telescopes

Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

O'Dell, Stephen L.↗

X-ray imaging of liquid-liquid Mg cavitation

The coupling of dynamic loading platforms with synchrotron light sources have enabled experiments examining void formation in optically opaque materials. Much like spallation in a solid, cavitation occurs when rarefaction waves collide within a liquid. The resulting deformation leads to a complex flow field with numerous voids. It has been suggested that compaction of such a structure may be a significant source of ejecta (i.e. shallow bubble collapse). Experiments imaging supported and unsupported shocks interacting with a free surface in shock melted Mg with synchrotron radiation are presented. Here, the results are used to examine the structure of a cavitation plane that forms in the unsupported case and provide an estimate of the porosity within this region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗