Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Experimental validation of a radio frequency photogun as external electron injector for a laser wakefield accelerator

A purpose-built RF-photogun as external electron injector for a laser wakefield accelerator has been thoroughly tested. Different properties of the RF-photogun have been measured such as energy, energy spread and transverse emittance. The focus of this study is the investigation of the smallest possible focus spot and focus stability at the entrance of the plasma channel. For an electron bunch with 10 pC charge and 3.7 MeV kinetic energy, the energy spread was 0.5% with a shot-to-shot stability of 0.05%. After focusing the bunch by a pulsed solenoid lens at 140 mm from the middle of the lens, the focal spot was 40 {mu}m with a shot-to-shot stability of 5 {mu}m. Higher charge leads to higher energy spread and to a larger spot size, due to space charge effects. All properties were found to be close to design values. Given the limited energy of 3.7 MeV, the properties are sufficient for this gun to serve as injector for one particular version of laser wakefield acceleration, i.e., injection ahead of the laser pulse. These measured electron bunch properties were then used as input parameters for simulations of electron bunch injection in a laser wakefield accelerator. The arrival time jitter was deduced from measurements of the energy fluctuation, in combination with earlier measurements using THz coherent transition radiation, and is around 150 fs in the present setup. The bunch length in the focus, simulated using particle tracking, depends on the accelerated charge and goes from 100 fs at 0.1 pC to 1 ps at 50 pC. When simulating the injection of the 3.7 MeV electron bunch of 10 pC in front of a 25 TW laser pulse with a waist of 30 {mu}m in a plasma with a density of 0.7 x 10{sup 24} m{sup -3}, the maximum accelerated charge was found to be 1.2 pC with a kinetic energy of {approx}900 MeV and an energy spread of {approx}5%. The experiments combined with the simulations show the feasibility of external injection and give a prediction of the output parameters that can be expected from a laser wakefield accelerator with external injection of electrons.

43 PARTICLE ACCELERATORS↗

Studies with Cluster upstream and downstream of the bow shock: An experimenter's perspective

Some open questions in the physics of bow shock formation, the evolution of the particle distributions from solar wind into the magnetosheath, and the acceleration of ions at the moment of the shock are summarized. A layout of the current situation is presented in view of recent theoretical developments and the new diagnostic tools provided by the Cluster mission. The transition of ions across the quasi-perpendicular bow shock and their downstream thermalization are discussed. The processes and spatial scales are found to be species dependent and are discussed for H(+), He(2+), and He(+). The theory of particle acceleration at quasi-parallel shocks are reviewed. It is shown how Cluster can study the time variable structures of the shock as predicted by hybrid simulation. It is emphasized that high time resolution measurement with simultaneous species separation is necessary for the study of the ion acceleration. Suggestions for the spacecraft separations at the bow shock are suggested.

Moebius, E.↗

Multiplexed Electrochemical Immunoassay of Phosphorylated Proteins Based on Enzyme-Functionalized Gold Nanorod Labels and Electric Field-Driven Acceleration

A multiplexed electrochemical immunoassay integrating enzyme amplification and electric field-driven strategy was developed for fast and sensitive quantification of phosphorylated p53 at Ser392 (phospho-p53 392), Ser15 (phospho-p53 15), Ser46 (phospho-p53 46) and total p53 simultaneously. The disposable sensor array has four spatially separated working electrodes and each of them is modified with different capture antibody, which enables simultaneous immunoassay to be conducted without cross-talk between adjacent electrodes. The enhanced sensitivity was achieved by multi-enzymes amplification strategy using gold nanorods (AuNRs) as nanocarrier for co-immobilization of horseradish peroxidase (HRP) and detection antibody (Ab2) at high ratio of HRP/Ab2, which produced an amplified electrocatalytic response by the reduction of HRP oxidized thionine in the presence of hydrogen peroxide. The immunoreaction processes were accelerated by applying +0.4 V for 3 min and then -0.2 V for 1.5 min, thus the whole sandwich immunoreactions could be completed in less than 5 min. The disposable immunosensor array shows excellent promise for clinical screening of phosphorylated proteins and convenient point-of-care diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement and Control of Beam Energy at the Fermilab 400 MeV Transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped of the extra electrons to become protons. Tuning Linac is performed using diagnostics to ensure stable intensity and energy while minimizing uncontrolled particle loss. I have been revisiting diagnostics in the Linac in order to understand their signals and to ensure their data is reliable. I revisited Beam Loss Monitors (BLMs) for the loss data confidence. For the confidence of energy data there were two approaches. The first approach was time-of-flight measurements using Beam Position Monitors (BPMs) and beam velocity stripline pick-up that provides beam phase data. The second approach used the relation between beam position data from BPMs and dispersion values from MAD-X simulation to calculate energy. Our goal after understanding the data from the Linac diagnostics and finding the data reliable is to control the L inac parameters using Machine Learning techniques to increase the reliability and quality of beam delivered from Linac.

43 PARTICLE ACCELERATORS↗

Quasimonochromatic x-ray backlighting on the COrnell Beam Research Accelerator (COBRA) pulsed power generator

Monochromatic x-ray backlighting has been employed with great success for imaging of plasmas with strong self-emission such as x-pinches and wire array z-pinches. However, implementation of a monochromatic backlighting system typically requires extremely high quality spherically bent crystals which are difficult to manufacture and can be prohibitively expensive. Furthermore, the crystal must have a direct line of sight to the object, which typically emits copious amounts of radiation and debris. We present a quasimonochromatic x-ray backlighting system which employs an elliptically bent mica crystal as the dispersive element. In this scheme a narrow band of continuum radiation is selected for imaging, instead of line radiation in the case of monochromatic imaging. The flat piece of mica is bent using a simple four-point bending apparatus that allows the curvature of the crystal to be adjusted in situ for imaging in the desired wavelength band. This system has the advantage that it is very cost effective, has a large aperture, and is extremely flexible. The principles of operation of the system are discussed and its performance is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency-Domain Streak Camera and Tomography for Ultrafast Imaging of Evolving and Channeled Plasma Accelerator Structures

We demonstrate a prototype Frequency Domain Streak Camera (FDSC) that can capture the picosecond time evolution of the plasma accelerator structure in a single shot. In our prototype Frequency-Domain Streak Camera, a probe pulse propagates obliquely to a sub-picosecond pump pulse that creates an evolving nonlinear index 'bubble' in fused silica glass, supplementing a conventional Frequency Domain Holographic (FDH) probe-reference pair that co-propagates with the 'bubble'. Frequency Domain Tomography (FDT) generalizes Frequency-Domain Streak Camera by probing the 'bubble' from multiple angles and reconstructing its morphology and evolution using algorithms similar to those used in medical CAT scans. Multiplexing methods (Temporal Multiplexing and Angular Multiplexing) improve data storage and processing capability, demonstrating a compact Frequency Domain Tomography system with a single spectrometer.

43 PARTICLE ACCELERATORS↗

Development of an X-ray Micro-Laminography System at SPring-8

An x-ray micro-laminography system has been developed at SPring-8 and applied to measurements of planar objects that cannot be observed by x-ray computed tomography. To reconstruct a sectional image parallel to the planar surface, a filtered back-projection technique considering the inclination angle of a rotational axis was developed. Experimental conditions suitable for laminography measurements in this system were investigated. Spatial resolution in the reconstructed plane was almost determined by the detector resolution, while the spatial resolution perpendicular to the planar surface tended to be worse by the artifacts inherent of the laminographic scanning and reconstruction method. A laminated test sample was clearly observed in three dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

Optical emission spectroscopy of the Linac4 and superconducting proton Linac plasma generators

CERN's superconducting proton Linac (SPL) study investigates a 50 Hz high-energy, high-power Linac for H{sup -} ions. The SPL plasma generator is an evolution of the DESY ion source plasma generator currently operated at CERN's Linac4 test stand. The plasma generator is a step towards a particle source for the SPL, it is designed to handle 100 kW peak RF-power at a 6% duty factor. While the acquisition of an integrated hydrogen plasma optical spectrum is straightforward, the measurement of a time-resolved spectrum requires dedicated amplification schemes. The experimental setup for visible light based on photomultipliers and narrow bandwidth filters and the UV spectrometer setup are described. The H{sub {alpha}}, H{sub {beta}}, and H{sub {gamma}} Balmer line intensities, the Lyman band and alpha transition were measured. A parametric study of the optical emission from the Linac4 ion source and the SPL plasma generator as a function of RF-power and gas pressure is presented. The potential of optical emission spectrometry coupled to RF-power coupling measurements for on-line monitoring of short RF heated hydrogen plasma pulses is discussed.

43 PARTICLE ACCELERATORS↗

Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels

Purpose: This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices.Methods: The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons).Results: For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning.Conclusions: Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT/VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Review of collective beam instabilities in electron-positron storage rings

The review of studies of collective beam instabilities in electron-positron storage rings is presented. The processes of excitation and suppression of the longitudinal microwave instability, transverse mode coupling instability, longitudinal and transverse multi-bunch instabilities, and instabilities induced by an interaction of a beam with ions or electron clouds are discussed. Important equations for estimation of the threshold beam currents and the rise time of instabilities, as well as the references to the major original works are given. The methods for diagnostics and suppression of instabilities are considered using specific examples.

43 PARTICLE ACCELERATORS↗

Electrodeless, Non-Invasive X-Ray Flux Monitor

Flux monitoring is a must at modern x-ray light sources for alignment, measurement feedback and calibration. Dedicated x-ray flux monitors occupy space, absorb part of the beam and cannot be easily relocated. At the same time numerous x-ray beamline elements (vacuum windows, monochromators, refractive lenses, zone plates to name a few) inevitably absorb portion of the x-ray beam which is proportional to incoming flux. At present there are no devices which can measure flux non-invasively based on this parasitic absorption

43 PARTICLE ACCELERATORS↗

The Operation of the Tevatron Vacuum System

Outline: Tevatron Overview and Some History; Vacuum Upgrades; Cryogenic Upgrades; Maintenance and Records; Vacuum Diagnostics; Failures; Lessons Learned

43 PARTICLE ACCELERATORS↗

Development of optical diagnostics for performance evaluation of arcjet thrusters

Laser and optical emission-based measurements have been developed and implemented for use on low-power hydrogen arcjet thrusters and xenon-propelled electric thrusters. In the case of low power hydrogen arcjets, these laser induce fluorescence measurements constitute the first complete set of data that characterize the velocity and temperature field of such a device. The research performed under the auspices of this NASA grant includes laser-based measurements of atomic hydrogen velocity and translational temperature, ultraviolet absorption measurements of ground state atomic hydrogen, Raman scattering measurements of the electronic ground state of molecular hydrogen, and optical emission based measurements of electronically excited atomic hydrogen, electron number density, and electron temperature. In addition, we have developed a collisional-radiative model of atomic hydrogen for use in conjunction with magnetohydrodynamic models to predict the plasma radiative spectrum, and near-electrode plasma models to better understand current transfer from the electrodes to the plasma. In the final year of the grant, a new program aimed at developing diagnostics for xenon plasma thrusters was initiated, and results on the use of diode lasers for interrogating Hall accelerator plasmas has been presented at recent conferences.

Cappelli, Mark A.↗

A proof of concept investigation: A unique mobility spectrometer for In Situ diagnostics of positive and negative ion distributions in the mesosphere and lower ionosphere

We have carried out a proof-of-concept development and test effort that not only promises the reduction of parasitic effects of surface contamination (therefore increasing the integrity of 'in situ' measurements in the 60-130 km regime), but promises a uniquely expanded measurement set that includes electron densities, plasma conductivities, charged-particle mobilities, and mass discrimination of positive and negative ion distributions throughout the continuum to free-molecular-flow regimes. Three different sensor configurations were designed, built and tested, along with specialized driving voltage, electrometer and channeltron control electronics. The individual systems were tested in a variety of simulated space environments ranging from pressures near the continuum limit of 100 mTorr to the collisionless regime at 10(exp -6) Torr. Swept modes were initially employed to better understand ion optics and ion 'beam' losses to end walls and to control electrodes. This swept mode also helped better understand and mitigate the influences of secondary electrons on the overall performance of the PIMS design concept. Final results demonstrated the utility of the concept in dominant single-ion plasma environments. Accumulated information, including theoretical concepts and laboratory data, suggest that multi-ion diagnostics are fully within the instrument capabilities and that cold plasma tests with minimized pre-aperture sheath acceleration are the key ingredients to multi-ion success.

Szuszczewicz, Edward P.↗

Traffic-Light-Preemption Vehicle-Transponder Software Module

A prototype wireless data-communication and control system automatically modifies the switching of traffic lights to give priority to emergency vehicles. The system, which was reported in several NASA Tech Briefs articles at earlier stages of development, includes a transponder on each emergency vehicle, a monitoring and control unit (an intersection controller) at each intersection equipped with traffic lights, and a central monitoring subsystem. An essential component of the system is a software module executed by a microcontroller in each transponder. This module integrates and broadcasts data on the position, velocity, acceleration, and emergency status of the vehicle. The position, velocity, and acceleration data are derived partly from the Global Positioning System, partly from deductive reckoning, and partly from a diagnostic computer aboard the vehicle. The software module also monitors similar broadcasts from other vehicles and from intersection controllers, informs the driver of which intersections it controls, and generates visible and audible alerts to inform the driver of any other emergency vehicles that are close enough to create a potential hazard. The execution of the software module can be monitored remotely and the module can be upgraded remotely and, hence, automatically

Bachelder, Aaron↗

Particle Impact Simulation and Ignition Prediction

An experimentally calibrated tool is needed to predict if a system is susceptible to failure by particle impact ignition (PI) based on use conditions, materials, and flow geometry. This tool will accelerate new components, evaluating existing hardware, and help disposition anomalies. Conduct particle impact testing with in-situ diagnostics and complementary simulations on subset of key engineering materials (IN718, M400, 316L, 6061, Ti64, Zr) to develop a proof-of-concept predictive tool for assessing the risk of PI for idealized geometries (spherical particles) in realistic environments. Assess particle/target interactions (coefficient of restitution, ignition, kindling) using instrumented particle impact rigs while systematically varying key parameters (materials, particle size, environment, target configuration). Determine key field variables (temperature, strain, stress) in particle impacts using Multiphysics finite element and hydrocode simulations validated through comparison with experimental measurements and observations. Synthesize experiments and simulations into constitutive models for PI that can be integrated with existing computational fluid dynamics (CFD) and Debris Transport Analysis (DTA) tools in future efforts

particle impact↗

Particle Impact Simulation and Ignition Prediction

An experimentally calibrated tool is needed to predict if a system is susceptible to failure by particle impact ignition (PI) based on use conditions, materials, and flow geometry. This tool will accelerate new components, evaluating existing hardware, and help disposition anomalies. - Conduct particle impact testing with in-situ diagnostics and complementary simulations on subset of key engineering materials (IN718, M400, 316L, 6061, Ti64, Zr) to develop a proof-of-concept predictive tool for assessing the risk of PI for idealized geometries (spherical particles) in realistic environments. - Assess particle/target interactions (coefficient of restitution, ignition, kindling) using instrumented particle impact rigs while systematically varying key parameters (materials, particle size, environment, target configuration). - Determine key field variables (temperature, strain, stress) in particle impacts using Multiphysics finite element and hydrocode simulations validated through comparison with experimental measurements and observations. - Synthesize experiments and simulations into constitutive models for PI that can be integrated with existing computational fluid dynamics (CFD) and Debris Transport Analysis (DTA) tools in future efforts.

Jonathan Tylka↗