Development and evaluation of integrated infrared arrays for astronomical applications

The status of a technology program to evaluate existing infrared detector arrays, and to develop improved ones for low background astronomical applications, is described. For applications such as the Shuttle Infrared Telescope Facility, arrays that cover as much of the 1-1000 micron range as possible are of interest. Low background test results for a 2 x 64 Si:Bi charge-injection-device, and 1 x 20 InSb charge-coupled-device arrays, are included. As a result of the present testing, improved, astronomy-optimized extrinsic silicon arrays in both linear and area formats are planned. Efforts to develop accumulation mode MOSFETs specifically for liquid helium temperatures, and cryogenic amplifier and multiplexer circuits, are discussed.

Mccreight, C. R.↗

Observation of collective modes of excitations in 59 Co, 59 Ni, and 61 Co and the influence of the $g_{9/2}$ orbital

High-spin states in 59 Co (Z = 27), 59 Ni (Z = 28), and 61 Co have been populated by the fusion evaporation reactions, 48 Ti( 14 C, p2n ) 59 Co, 48 Ti( 14 C, 3 n ) 59 Ni, and 50 Ti( 14 C, p2n ) 61 Co. The 9 MV tandem accelerator at the John D. Fox Laboratory, Florida State University (FSU) was used to accelerate the 14 C beam and the deexciting γ rays were detected by the FSU detector array consisting of six high-purity germanium (HPGe) clover detectors and three single crystals. Directional correlation of the $γ$ rays deexciting oriented states (DCO ratios) and polarization asymmetry measurements helped to establish spin and parities of the excited states whenever possible. The level scheme of 59 Co has been expanded with the inclusion of positive-parity states up to 31/2 + at around 11 MeV. The 59 Ni positive-parity states known from previous study were verified with modifications to some of the spins and parities. On the other hand, the negative-parity states were extended to 31/2 at an excitation energy of 12 MeV. No new transition was observed for 61 Co, but one of the major bands has been reassigned as consisting of positive-parity states by reason of this study. Importantly, excitations observed within the f 7/2 , p 3/2 , f 5/2 , and p 1/2 orbitals, and also across the N = 40 subshell closure into the g 9/2 orbital was established by comparison with large-scale shell-model calculations for the three nuclei studied.

59 ≤ A ≤ 89↗

Majorana Demonstrator Bolted Joint Mechanical and Thermal Analysis

The MAJORANA DEMONSTRATOR is designed to probe for neutrinoless double-beta decay, an extremely rare process with a half-life in the order of 10 26 years. The experiment uses an ultra-low background, high-purity germanium detector array. The germanium crystals are both the source and the detector in this experiment. Operating these crystals as ionizing radiation detectors requires having them under cryogenic conditions (below 90 K). A liquid nitrogen thermosyphon is used to extract the heat from the detectors. The detector channels are arranged in strings and thermally coupled to the thermosyphon through a cold plate. The cold plate is joined to the thermosyphon by a bolted joint. This circular plate is housed inside the cryostat can. This document provides a detailed study of the bolted joint that connects the cold plate and the thermosyphon. An analysis of the mechanical and thermal properties of this bolted joint is presented. The force applied to the joint is derived from the torque applied to each one of the six bolts that form the joint. The thermal conductivity of the joint is measured as a function of applied force. The required heat conductivity for a successful experiment is the combination of the thermal conductivity of the detector string and this joint. The thermal behavior of the joint is experimentally implemented and analyzed in this study.

Aguayo Navarrete, Estanislao↗

Environmental testing of high Tc superconductive thermal isolators for space-borne cryogenic detector systems

Thick films of superconductive material on low thermal conductivity substrates (e.g., yttria-stabilized zirconia and fused silica) are considered as a replacement for the existing electrical connections between the detector array and data acquisition and storage electronics in the cryogenic detector systems being developed by NASA. The paper describes some of the design constraints on the superconducting device and presents results of a preliminary analysis of the effects of vibration, gamma irradiation, and long-term exposure to high vacuum and liquid nitrogen encountered in operating such a device in space.

Wise, Stephanie A.↗

NASA Tech Briefs, September 2013

Topics include: ISS Ammonia Leak Detection Through X-Ray Fluorescence; A System for Measuring the Sway of the Vehicle Assembly Building; Fast, High-Precision Readout Circuit for Detector Arrays; Victim Simulator for Victim Detection Radar; Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot; Quasi-Linear Circuit; High-Speed, High-Resolution Time-to-Digital Conversion; Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities; Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes; High-Powered, Ultrasonically Assisted Thermal Stir Welding; Next-Generation MKIII Lightweight HUT/Hatch Assembly; Centrifugal Sieve for Gravity-Level-Independent Size; Segregation of Granular Materials; Ion Exchange Technology Development in Support of the Urine Processor Assembly; Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material; UltraSail CubeSat Solar Sail Flight Experiment; Mechanism for Deploying a Long, Thin-Film Antenna From a Rover; Counterflow Regolith Heat Exchanger; Acquisition and Retaining Granular Samples via a Rotating Coring Bit; Very-Low-Cost, Rugged Vacuum System; Medicine Delivery Device With Integrated Sterilization and Detection; FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D; Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs; Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer; Complementary Barrier Infrared Detector (CBIRD) Contact Methods; Autonomous Control of Space Nuclear Reactors; High-Power, High-Speed Electro-Optic Pockels Cell Modulator; Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors; Enigma Version 12; Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program; Spitzer Telemetry Processing System; Planetary Protection Bioburden Analysis Program; Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2); ISSM: Ice Sheet System Model; Automated Loads Analysis System (ATLAS); Integrated Main Propulsion System Performance Reconstruction Process/Models. Phoenix Telemetry Processor; Contact Graph Routing Enhancements Developed in ION for DTN; GFEChutes Lo-Fi; Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service; Software for Generating Troposphere Corrections for InSAR Using GPS and Weather Model Data; Ionospheric Specifications for SAR Interferometry (ISSI); Implementation of a Wavefront-Sensing Algorithm; Sally Ride EarthKAM - Automated Image Geo-Referencing Using Google Earth Web Plug-In; Trade Space Specification Tool (TSST) for Rapid Mission Architecture (Version 1.2); Acoustic Emission Analysis Applet (AEAA) Software; Memory-Efficient Onboard Rock Segmentation; Advanced Multimission Operations System (ATMO); Robot Sequencing and Visualization Program (RSVP); Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies; Raster-Based Approach to Solar Pressure Modeling; Space Images for NASA JPL Android Version; Kinect Engineering with Learning (KEWL); Spacecraft 3D Augmented Reality Mobile App; MPST Software: grl_pef_check; Real-Time Multimission Event Notification System for Mars Relay; SIM_EXPLORE: Software for Directed Exploration of Complex Systems; Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure; Advanced Query and Data Mining Capabilities for MaROS; Jettison Engineering Trajectory Tool; MPST Software: grl_suppdoc; PredGuid+A: Orion Entry Guidance Modified for Aerocapture; Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl; and Space Place Prime.

Source record↗

Explosive Detection in Aviation Applications Using CT

CT scanners are deployed world-wide to detect explosives in checked and carry-on baggage. Though very similar to single- and dual-energy multi-slice CT scanners used today in medical imaging, some recently developed explosives detection scanners employ multiple sources and detector arrays to eliminate mechanical rotation of a gantry, photon counting detectors for spectral imaging, and limited number of views to reduce cost. For each bag scanned, the resulting reconstructed images are first processed by automated threat recognition algorithms to screen for explosives and other threats. Human operators review the images only when these automated algorithms report the presence of possible threats. The US Department of Homeland Security (DHS) has requirements for future scanners that include dealing with a larger number of threats, higher probability of detection, lower false alarm rates and lower operating costs. One tactic that DHS is pursuing to achieve these requirements is to augment the capabilities of the established security vendors with third-party algorithm developers. A third-party in this context refers to academics and companies other than the established vendors. DHS is particularly interested in exploring the model that has been used very successfully by the medical imaging industry, in which university researchers develop algorithms that are eventually deployed in commercial medical imaging equipment. The purpose of this paper is to discuss opportunities for third-parties to develop advanced reconstruction and threat detection algorithms.

42 ENGINEERING↗

Large-Scale Magnetic Microcalorimeter: Modeling and Multiplexing

We will present performance predictions for a large-scale magnetic microcalorimeter detector array intended for a potential future X-ray astrophysics mission. The focal plane comprises three distinct array designs, necessitating over 100,000 pixels to meet the scientific objectives. Our presentation will describe the results of numerical modeling aimed at estimating the energy resolution and detector responses for each array. Additionally, we will discuss the application of microwave multiplexing technology for the comprehensive readout of the entire sensor array.

x-ray↗

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

InSb arrays: Astronomy with a 32x32 CCD/development of a 58x62 DRO

Experience gained in operating infrared detector arrays for high sensitivity astronomical applications at the University of Rochester are summarized. Progress made in operating the 32 x 32 InSb array with bump-bonded Silicon CCD readout is described. Astronomical work done with the 32 x 32 camera is also described. Plans for the future, including improvements for the 32 x 32 camera system as well as implementing a new generation of 58 x 62 InSb array using switched-MOSFET direct readout multiplexing system in the place of the older CCD technology is discussed.

Forrest, W. J.↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

SU-D-BRD-07: Evaluation of the Effectiveness of Statistical Process Control Methods to Detect Systematic Errors For Routine Electron Energy Verification

Purpose: To evaluate the ability of statistical process control methods to detect systematic errors when using a two dimensional (2D) detector array for routine electron beam energy verification. Methods: Electron beam energy constancy was measured using an aluminum wedge and a 2D diode array on four linear accelerators. Process control limits were established. Measurements were recorded in control charts and compared with both calculated process control limits and TG-142 recommended specification limits. The data was tested for normality, process capability and process acceptability. Additional measurements were recorded while systematic errors were intentionally introduced. Systematic errors included shifts in the alignment of the wedge, incorrect orientation of the wedge, and incorrect array calibration. Results: Control limits calculated for each beam were smaller than the recommended specification limits. Process capability and process acceptability ratios were greater than one in all cases. All data was normally distributed. Shifts in the alignment of the wedge were most apparent for low energies. The smallest shift (0.5 mm) was detectable using process control limits in some cases, while the largest shift (2 mm) was detectable using specification limits in only one case. The wedge orientation tested did not affect the measurements as this did not affect the thickness of aluminum over the detectors of interest. Array calibration dependence varied with energy and selected array calibration. 6 MeV was the least sensitive to array calibration selection while 16 MeV was the most sensitive. Conclusion: Statistical process control methods demonstrated that the data distribution was normally distributed, the process was capable of meeting specifications, and that the process was centered within the specification limits. Though not all systematic errors were distinguishable from random errors, process control limits increased the ability to detect systematic errors using routine measurement of electron beam energy constancy.

07 ISOTOPE AND RADIATION SOURCES↗

A high energy Space Station (HESS) array for studying extremely energetic cosmic rays

The scientific aims and design concept of a High-Energy Space Station (HESS) cosmic-ray detector array are discussed. The current state of knowledge on cosmic-ray acceleration and high-energy interactions is briefly reviewed, and the need for observations yielding elemental composition and spectra in the 10-10,000-TeV/nucleon range is demonstrated. It is predicted that 2 yr of observations with a space-borne detector of geometry factor 30 sq m sr would provide adequate data to determine the acceleration mechanism (by comparing the energy level at which the spectra of He nuclei and protons break). A modular HESS array comprising W/scintillator/PM-tube calorimeter modules and Cerenkov charge-sensitive detector modules and weighing about 30 tonnes is described. The array could be assembled on orbit after transport in the Space Shuttle cargo bay, and data could be taken as soon as one or two layers of modules had been attached to the mounting-frame/support-electronics unit.

Ormes, J. F.↗

Fusion-Fission In The {sup 86}Kr+{sup 238}U Reaction

The {sup 86}Kr+{sup 238}U reaction has been studied at krypton beam energies about 30 MeV above the Coulomb barrier. Reaction products were detected by an array of 32 photovoltaic cells coupled to the AFRODITE {gamma}-ray detector array at iThemba LABS. A symmetric fission component has been observed at about 600 MeV total kinetic energy. This could possibly be due to fusion-fission with a cross section of 35{+-}20 mb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

(n,{gamma}) Experiments on tin isotopes

Neutron capture experiments on highly enriched {sup 117,119}Sn isotopes were performed with the DANCE detector array located at the Los Alamos Neutron Science Center. The DANCE detector provides detailed information about the multi-step {gamma}-ray cascade following neutron capture. Analysis of the experimental data provides important information to improve understanding of the neutron capture reaction, including a test of the statistical model, the assignment of spins and parities of neutron resonances, and information concerning the Photon Strength Function (PSF) and Level Density (LD) below the neutron separation energy. Preliminary results for the (n,{gamma}) reaction on {sup 117,119}Sn are presented. Resonance spins of the odd-A tin isotopes were almost completely unknown. Resonance spins and parities have been assigned via analysis of the multi-step {gamma}-ray spectra and directional correlations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A CCD scanned (Hg, Cd)Te array for earth viewing applications

A 9 channel demonstration of 10 micrometer photoconductive mercury cadmium telluride detector array, bipolar preamplifiers, and a Si CCD multiplexer, integrated into a focal plane assembly and operating at 105 K and at 17 Hz is reported. The result of a direct coupling experiment between a 5-micrometer photovoltaic mercury cadmium telluride photodiode and a CCD is revealed. No appreciable degradation in the signal-to-noise ratio was experienced.

Iwasa, S.↗

The on-orbit performance of the STIS detectors

The Space Telescope Imaging Spectrograph (STIS), successfully installed into the Hubble Space Telescope in February 1997, achieves its advances over the first-generation HST spectrographs primarily through the use of modern large-format, two-dimensional array detectors. The performance of the STIS detectors, two Multi-Anode Microchannel Arrays (MAMAS) and one CCD, has been evaluated on-orbit as part of the Servicing Mission Orbital Verification (SMOV) program. All three detectors are functioning well. We report highlights of the results to date here.

Kimble, Randy A.↗

High-resolution detectors for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of pulse-counting imaging array detectors designed specifically for astrophysical investigations in space. The MAMAs have a number of unique performance characteristics which make them particularly suitable for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths. First, they employ 'solar blind' photocathodes eliminating the 'red leak' problem associated with solid state arrays such as the CCDs. Second, they operate with zero readout noise, yielding photon-statistics limited signals. Third, they utilize a random readout technique and can determine both the location of a detected photon and also its arrival time to an accuracy of the order of 100 ns. This paper gives an overview of the construction, mode of operation, and performance characteristics of the MAMA detectors and describes the current status of the development program.

Timothy, J. G.↗