Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Plasma-controlled metal catalyst saturation and the initial stage of carbon nanostructure array growth

The kinetics of the nucleation and growth of carbon nanotube and nanocone arrays on Ni catalyst nanoparticles on a silicon surface exposed to a low-temperature plasma are investigated numerically, using a complex model that includes surface diffusion and ion motion equations. It is found that the degree of ionization of the carbon flux strongly affects the kinetics of nanotube and nanocone nucleation on partially saturated catalyst patterns. The use of highly ionized carbon flux allows formation of a nanotube array with a very narrow height distribution of half-width 7 nm. Similar results are obtained for carbon nanocone arrays, with an even narrower height distribution, using a highly ionized carbon flux. As the deposition time increases, nanostructure arrays develop without widening the height distribution when the flux ionization degree is high, in contrast to the fairly broad nanostructure height distributions obtained when the degree of ionization is low.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dot arrays of L1{sub 1} type Co-Pt ordered alloy perpendicular films

Magnetic properties of dot arrays of L1{sub 1} type Co-Pt ordered alloy perpendicular films were studied. L1{sub 1}-Co-Pt films with a large uniaxial magnetic anisotropy K{sub u} of the order of 10{sup 7} erg/cm{sup 3} were fabricated at a substrate temperature of 360 deg. C using ultrahigh vacuum sputter film deposition. Dot patterns with dot diameters of 70-200 nm were made using high resolution e-beam lithography and reactive ion etching (RIE). The values of K{sub u} were measured by the GST method using the Anomalous Hall Effect; we observed the averaged signals of 6000 dots. The values of K{sub u} for dot arrays of 10-nm-thick L1{sub 1}-Co{sub 50}Pt{sub 50} films deposited on MgO(111) substrates (single crystal films) and glass disks (polycrystalline films) were nearly the same as those of the original films independent of D, indicating no significant etching damage by the RIE process. Magnetic force microscopy images revealed that all dots were single domains in the present D region. The coercivity H{sub c} of the dot arrays was 25.0 kOe [MgO(111) substrate, D=70 nm] and 14.3 kOe (glass disks, D=80 nm). The switching field distribution {sigma}/H{sub c} was relatively small, {sigma}/H{sub c}=0.15, even for dot arrays fabricated on glass disks, indicating the homogeneous formation of a L1{sub 1} type ordered structure in the Co{sub 50}Pt{sub 50} layers.

36 MATERIALS SCIENCE↗

Underground Prototype Water Cherenkov Muon Detector with the Tibet Air Shower Array

We are planning to build a 10,000 m{sup 2} water-Cherenkov-type muon detector (MD) array under the Tibet air shower (AS) array. The Tibet AS+MD array will have the sensitivity to detect gamma rays in the 100 TeV region by an order of the magnitude better than any other previous existing detectors in the world. In the late fall of 2007, a prototype water Cherenkov muon detector of approximately 100 m{sup 2} was constructed under the existing Tibet AS array. The preliminary data analysis is in good agreement with our MC simulation. We are now ready for further expanding the underground water Cherenkov muon detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics of Multi-Planar and Compact Cylindrical Wire Arrays Implosions on University-Scale Z-pinch Generators

The presented research focuses on investigation of Z-pinch plasma formation, implosion, and radiation characteristics as a function of the load configuration. The single planar and multi-planar wire arrays as well as compact cylindrical wire arrays were studied on the 1.3 MA UNR Zebra and 1 MA Cornell COBRA generators. The largest yields and powers were found for W and Mo double planar and compact wire arrays. A possibility of radiation pulse shaping was demonstrated. Two types of bright spots were observed in plasmas. A comparison of Mo double planar and compact wire array data indicates the possibility that the same heating mechanism operates during the final implosion and stagnation stages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Conical Wire Array Z-Pinch Stability with a Center Wire

Adding a center wire on the axis of a conical wire array produces conditions suitable for studying shear flow stabilization of the Z-pinch. The conical wire array produces and axial plasma flow while the center wire introduces a radial variation of the axial velocity. Experiments of this array configuration were preformed on the 1 MA Zebra Z-pinch generator and showed stabilization of the kink instability when a center wire was present. Comparison with equivalent cylindrical wire arrays indicates that the shear flow stabilization plays a role in the stabilization of the kink instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of an Axial Wire on Conical Wire Array Z-Pinch Radiation

Adding a wire on the axis of wire arrays significantly affects the x-ray emission of the conical arrays, and much less that of the cylindrical ones. The radiation of the conical wire arrays increases with the thickness of the central wire, surpassing that of the equivalent cylindrical arrays. Significant energy is emitted early on, around the time of the conical shock formation, before the pinch stagnation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling of Radiation Parameters of Planar and Compact Cylindrical Wire Arrays at the 1 MA Zebra Generator

Analysis is presented on scaling of radiated x-ray power, energy and implosion timing of single planar wire arrays (SPWA), double planar wire array (DPWA), and compact cylindrical wire array (CCWA) loads (diameter is 3 and 6 mm) of Mo and W with respect to current peak (0.8-1.4 MA), mass and array dimensions at 100 ns current pulse. Such scaling investigations are important for understanding the potential of these loads as an ICF radiation source{sup 7}. These data are used to identify promising directions to pursue with regard to highest x-ray output, smallest load size, and most consistent shot-to-shot performance. It is shown that W SPWA and DPWA total energy yield and peak power increased near-quadratically with current. DPWA scans of inter-planar gaps from 1.5 mm to 9 mm show an output maximum at 1.5 mm with decreasing output for 6 mm and 9 mm. A DPWA width scan shows that radiation yields decrease slowly as the width is decreased, which may allow for more compact loads without significant sacrifice to the output radiation. A mass scan of several W loads show that the implosion timing increases with mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Field Measurements in Wire-Array Z-Pinches using Magneto-Optically Active Waveguides

Understanding the magnetic field topology in wire-array Z-pinches as a function of time is of great significance to understanding these high-energy density plasmas especially for their ultimate application to stockpile stewardship and inertial confinement fusion. We are developing techniques to measure magnetic fields as a function of space and time using Faraday rotation of a single longitudinal mode (SLM) laser through a magneto-optically active bulk waveguide (multicomponent terbium borate glass) placed adjacent to, or within, the wire array in 1 MA experiments. We have measured fields >10 T with 100 ns rise times outside of a wire-array for the entire duration of the current pulse and as much as {approx}2 T inside a wire-array for {approx}40 ns from the start of current. This is the first time that such rapidly varying and large fields have been measured using these materials. In a dense Z-pinch, these sensing devices may not survive for long but may provide the magnetic field at the position of the sensor that can be used to corroborate magnetic probes, with which we compare our results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface modification of highly ordered TiO{sub 2} nanotube arrays for efficient photoelectrocatalytic water splitting

An efficient visible-light-sensitive heterostructure photoanode of CdS nanoparticles/ZnO shell/TiO{sub 2} nanotube (CdS/ZnO-TiNT) arrays were investigated for solar water splitting. Highly ordered arrays of TiNT were grown vertically on Ti foil by electrochemical anodization. Both aqueous solution routes were used in turn to coat a thin recombination barrier of ZnO shell and narrow band gap CdS nanoparticles to the surface of the TiNT arrays. As a result of strong absorption within solar spectrum and effective suppression of electron-hole pair recombination in CdS/ZnO-TiNT arrays, a significant improvement in solar-to-hydrogen conversion efficiency from 0.39% to 1.30% was obtained.

36 MATERIALS SCIENCE↗

A 1372-element Large Scale Hemispherical Ultrasound Phased Array Transducer for Noninvasive Transcranial Therapy

Noninvasive transcranial therapy using high intensity focused ultrasound transducers has attracted high interest as a promising new modality for the treatments of brain related diseases. We describe the development of a 1372 element large scale hemispherical ultrasound phased array transducer operating at a resonant frequency of 306 kHz. The hemispherical array has a diameter of 31 cm and a 15.5 cm radius of curvature. It is constructed with piezoelectric (PZT-4) tube elements of a 10 mm in diameter, 6 mm in length and 1.4 mm wall thickness. Each element is quasi-air backed by attaching a cork-rubber membrane on the back of the element. The acoustic efficiency of the element is determined to be approximately 50%. The large number of the elements delivers high power ultrasound and offers better beam steering and focusing capability. Comparisons of sound pressure-squared field measurements with theoretical calculations in water show that the array provides good beam steering and tight focusing capability over an efficient volume of approximately 100x100x80 mm{sup 3} with nominal focal spot size of approximately 2.3 mm in diameter at -6 dB. We also present its beam steering and focusing capability through an ex vivo human skull by measuring pressure-squared amplitude after phase corrections. These measurements show the same efficient volume range and focal spot sizes at -6 dB as the ones in water without the skull present. These results indicate that the array is sufficient for use in noninvasive transcranial ultrasound therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying Radiation from Z-pinch Wire Array and X-Pinch Plasmas: K-shell Mg to M-shell Mo

University-scale Z-pinch generators are able to produce plasmas with a broad range of temperatures, densities, and opacity properties depending on the type, size, and mass of wire-array loads and wire materials. Experiments with very different Z-pinch loads were performed on the 1 MA Zebra generator at UNR and analyzed during the last five years including Single and Nested Cylindrical, Conical, and various types of Planar Wire Arrays. It is shown that such wire arrays are good sources of x-rays and that they produce significant radiation yield (up to 25 kJ) on a ns time scale, and generate bright spots of sub-mm size. They can be used for studying radiative properties of moderate density (between 10{sup 18} cm{sup -3} and 5x10{sup 21} cm{sup -3}) and temperature (<=1.5 keV) plasmas. In addition, X-pinches generated higher density (>10{sup 22} cm{sup -3}) and temperature (>2 keV) plasmas on scales as small as a few mum to several mm in size. Wire materials with a broad range of nuclear charge Z were used, ranging from low-Z, such as alloyed Al wires with varying concentrations of Mg, to mid-Z, such as Stainless steel, Cu, Brass, and Mo. Uniform (made from one wire material) as well as combined (made from two wire materials with almost equal wire masses) wire arrays were considered. Uniform, combined, symmetric and asymmetric X-pinches (some of which included a small fraction of tracer Al wires) were also considered. Non-LTE kinetic models to account for K- and L-shell radiation were employed to understand radiative properties of Z-pinch and X-pinch plasmas. Implosion characteristics of such loads are discussed using the wire dynamics and MHD models. Opacity effects of Z-pinch plasmas are studied and benefits of using alloyed and tracer wires are highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth and saturation of the axial instability in low wire number wire array Z pinches

The growth of the axial instability in low wire number wire array Z pinches using a 100 ns rise time, 1 MA pulsed power accelerator is examined. The axial instability manifests itself as a quasiperiodic variation of the radius of the coronal plasma along each wire and a consequent modulation of the rate of ablation of material from the dense wire core. The dominant wavelength of the modulation becomes constant late in time. In this work laser shadowgraphy is used to measure the growth of the wavelength and amplitude of the instability as well as the size of the coronal plasma in aluminum wire arrays from the time of plasma formation to the time the wavelength seen late in time is reached. Using magnetic probes, the distribution of current and magnetic topology are also investigated. It is found that a distinct change in magnetic field topology associated with the onset of advection of current to the array axis by the streaming wire-ablation plasma appears to be responsible for ending the growth of the axial instability and initiating the quasisteady state ablation phase of the wire array Z pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress Toward Corrugated Feed Horn Arrays in Silicon

We are developing monolithic arrays of corrugated feed horns fabricated in silicon for dual-polarization single-mode operation at 90, 145 and 220 GHz. The arrays consist of hundreds of platelet feed horns assembled from gold-coated stacks of micro-machined silicon wafers. As a first step, Au-coated Si waveguides with a circular, corrugated cross section were fabricated; their attenuation was measured to be less than 0.15 dB/cm from 80 to 110 GHz at room temperature. To ease the manufacture of horn arrays, electrolytic deposition of Au on degenerate Si without a metal seed layer was demonstrated. An apparatus for measuring the radiation pattern, optical efficiency, and spectral band-pass of prototype horns is described. Feed horn arrays made of silicon may find use in measurements of the polarization anisotropy of the cosmic microwave background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results On The Imaging Capabilities Of A DROID Array In The UV/Visible

Within the SCAM project of the European Space Agency the next step in the development of a cryogenic optical photon counting imaging spectrometer would be to increase the field of view using DROIDs (Distributed Read-Out Imaging Detector). We present the results of the first system test using an array of 60 360x33.5 {mu}m{sup 2} DROIDs in a 3x20 format for optical photon detection. This is an increase in area by a factor of 5.5 compared to the successful S-Cam 3 detector. The responsivity of the DROID array tested is too low for actual use on the telescope. However the spatial resolution of {approx}35 {mu}m is just above the size of a virtual pixel and imaging capabilities of the array can be demonstrated. With increasing responsivity this will improve, yielding a DROID array which can be used as an astronomical optical photon counting imaging spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of magnetic field in the transition to streaming ablation in wire arrays

In wire array Z-pinches, the magnetic field configuration and the global field penetration of individual wires play a key role in the ablation plasma dynamics. Knowledge of the magnetic field configuration is necessary to understand the ablation plasma acceleration process near the wires. Two-dimensional resistive magnetohydrodynamics simulations show that a change in the global magnetic field configuration is critical to initiating inward flow of the ablation plasma. Analysis of these simulations show that the initially compressive JxB force around a wire in its vacuum field configuration undergoes a transition to a configuration in which the Lorentz force can accelerate plasma toward the array axis. This transition is achieved through a low magnetic Reynolds number diffusive flow in which the plasma and the magnetic field are decoupled. The plasma current follows the expanding plasma toward the array axis and, after traveling a critical distance scaling with the array radius divided by the wire number, the global magnetic field threads the wire core, thereby allowing JxB coronal acceleration into ablation streams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical studies of ablated-plasma dynamics and precursor current of wire-array Z-pinches

The dynamics of ablated plasmas of wire-array Z-pinches are studied numerically in (r,{theta}) geometry by using the magnetohydrodynamic (MHD) simulation model in which the mass injection boundary conditions are presented, and two-dimensional spatio-temporal distributions of magnetic field and precursor current during the ablation phase are obtained. The ablated-plasma dynamics contains four processes: drifting toward the axis, arriving at the axis and forming the precursor column, and contraction and expansion of the precursor column. The relationship among the maximum inward velocity of ablated plasma streams and the initial wire array parameters is analyzed and it is found that this velocity is relatively sensitive to the change of inter-wire separation but weakly depends on the original array radius. The results are in reasonable agreement with the experiments on MAGPIE facility. The origin of the current flow in the precursor plasmas is analyzed from the point of view of the B-field convection in (r,{theta}) plane. The dynamics of ablation streams determine the distribution of magnetic field and the current density J{sub z} inside the wire array. The precursor current can be approximately calculated by the integral of J{sub z} inside the region of a radius near to the column. In this model, the fraction of precursor current is less than 10% of the total current, which is close to the experimental results. When the current waveform is fixed, the increase of the inter-wire gap or decrease of the initial radius will lead to the increase of the precursor current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a twin crystal membrane coupled conformable phased array for the inspection of austenitic welds

The inspection of welded austenitic stainless steel components can be challenging. Austenitic welds contain an anisotropic, inhomogeneous grain structure which causes attenuation, scattering and beam bending. The inspection of components where the weld cap has not been removed is even more difficult due to the irregularity of the surface geometry. A twin crystal membrane coupled device has now been produced containing two linear phased arrays positioned adjacent to one another within the same housing. The arrays are angled relative to one another so that the transducer provides a pseudo-focusing effect at a depth corresponding to the beam crossing point. This type of design is used to improve the signal to noise ratio of the defect response in comparison to simple linear phased array transducer designs and to remove an internal noise signal found in linear phased array devices. Experimental results obtained from the through weld inspection of an austenitic stainless steel component with an undressed weld cap using the twin crystal membrane device are presented. These results demonstrate that small lack of side wall fusion defects can be reliably detected in large complex structures.

42 ENGINEERING↗

A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application

The authors report a carbon nanotube (CNT) field emission multipixel x-ray array source for microradiotherapy for cancer research. The developed multipixel x-ray array source has 50 individually controllable pixels and it has several distinct advantages over other irradiation source including high-temporal resolution (millisecond level), the ability to electronically shape the form, and intensity distribution of the radiation fields. The x-ray array was generated by a CNT cathode array (5x10) chip with electron field emission. A dose rate on the order of >1.2 Gy/min per x-ray pixel beam is achieved at the center of the irradiated volume. The measured dose rate is in good agreement with the Monte Carlo simulation result.

43 PARTICLE ACCELERATORS↗