Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

In Situ Observation of Acicular Ferrite Nucleation and Growth at Different Cooling Rate in Ti-Zr Deoxidized Steel

The effects of cooling rate on acicular ferrite (AF) nucleation, growth, and inclusion characteristics in Ti-Zr deoxidation steel were studied by utilizing the high temperature confocal laser scanning microscope (HT-CLSM). The results indicated that with the increase of cooling rate, the ferrite start nucleation temperature decreased, and the difference of first nucleation temperature between AF and ferrite side plate (FSP) reduced. When the cooling rate increased to 10.0 °C/s, AF and FSP simultaneously nucleated at 564.5 °C. In addition, the AF actual growth rate rose with the increase of cooling rate and reached 30.13 µm/s at 10.0 °C/s cooling rate. The AF ratio in microstructure increased first and then decreased with the cooling rate increase and was up to the maximum 45.83 pct at 1.0 °C/s cooling rate. For inclusion characteristics, cooling rates had no obvious effect on inclusion types, but had a great influence on inclusions size distribution. With the cooling rate increase, the inclusion average diameter reduced, and diminished to 1.39 µm at 10.0 °C/s cooling rate. Finally, the AF nucleation on the Ti-Zr-Mn-O-S + TiN inclusion could be explained by the low lattice misfit between ferrite and TiN that precipitated on the Ti-Zr-Mn-O-S inclusion surface.

36 MATERIALS SCIENCE↗

The effects of magnetic fields on the growth of thermal instabilities in cooling flows

The effects of heat conduction and magnetic fields on the growth of thermal instabilities in cooling flows are examined using a time-dependent hydrodynamics code. It is found that, for magnetic field strengths of roughly 1 micro-Gauss, magnetic pressure forces can completely suppress shocks from forming in thermally unstable entropy perturbations with initial length scales as large as 20 kpc, even for initial amplitudes as great as 60 percent. Perturbations with initial amplitudes of 50 percent and initial magnetic field strengths of 1 micro-Gauss cool to 10,000 K on a time scale which is only 22 percent of the initial instantaneous cooling time. Nonlinear perturbations can thus condense out of cooling flows on a time scale substantially less than the time required for linear perturbations and produce significant mass deposition of cold gas while the accreting intracluster gas is still at large radii.

David, Laurence P.↗

Crystalline structure and magnetic behavior of the Ni 41 Mn 39 In 12 Co 8 alloy demonstrating giant magnetocaloric effect

Magnetic cooling is a green cooling technology, which is more energy efficient than existing fluid-compression cooling machines. Ni 41 Mn 39 In 12 Co 8 alloy, which demonstrates promising magnetocaloric performances, was investigated using neutron diffraction and thermomagnetic measurements. The austenite structure is cubic L2 1 $(Fm\bar{3}m),$ while that of the martensite is a mix of 8 and 6 M modulated monoclinic structures $(P\quad 1\quad 2/m\quad 1).$ The austenitic site occupancy refinements reveal that all substituting Co atoms occupy Ni-sites. Most Mn atoms (65%) are in the Mn-sites and the rest go to In-sites (about 35%) and Ni-sites (less than 5%). This disorder of the magnetic atoms (Mn, Ni and Co) in the austenitic phase remains unchanged during the martensitic transition. The distortions of the interatomic distances due to the modulation of the martensitic structures further enhance the disorder in the magnetic interactions. Thermomagnetic measurements indicate that the austenitic phase is ferromagnetic. Cooling to below 250 K, where the alloy loses its ferromagnetic nature, and down to 50 K, the lack of any antiferromagnetic Bragg peaks suggests no antiferromagnetic ordering in the martensitic phase. Here, at very low temperatures in the martensitic phase, spin glass magnetic nature is identified by magnetic measurements, and the spin-glass transition temperature is ~19 K.

36 MATERIALS SCIENCE↗

Cold-air aerodynamic study in a two-dimensional cascade of a turbine stator blade with suction-surface film cooling

The effect on aerodynamic performance of a single row of spanwise-spaced coolant holes located at four positions chordwise along the suction surface was investigated. In addition, multiple-row data were obtained. The data are presented in terms of primary efficiency, coolant-to-primary-flow percentage, and coolant pressure ratio. Primary efficiencies of multirow blade configurations compare satisfactorily with that calculated from the single-row efficiency increments. At any given coolant flow percentage, the efficiency was about the same for all row locations. For a given coolant pressure, the efficiency varied by as much as 1 percent, depending on the row location.

Brown, D. B.↗

Experimental Investigation on Additively Manufactured Transpiration and Film Cooling Structures

The last 50 years has witnessed significant improvement in film cooling technologies while transpiration cooling is still not implemented in turbine airfoil cooling. Although transpiration cooling could provide higher cooling efficiency with less coolant consumption compared to film cooling, the fine pore structure and high porosity in transpiration cooling metal media always raised difficulties in conventional manufacturing. Recently, the rapid development of additive manufacturing (AM) has provided a new perspective to address such challenge. With the capability of the innovative powder bed selective laser metal sintering (SLMS) AM technology, the complex geometries of transpiration cooling part could be precisely fabricated and endued with improved mechanical strength. This study utilized the SLMS AM technology to fabricate the transpiration cooling and film cooling structures with Inconel 718 superalloy. Five different types of porous media including two perforated plates with different hole pitches, metal sphere packing, metal wire mesh, and blood vessel shaped passages for transpiration cooling were fabricated by EOS M290 system. One laidback fan-shaped film cooling coupon was also fabricated with the same printing process as the control group. Heat transfer tests under three different coolant mass flow rates and four different mainstream temperatures were conducted to evaluate the cooling performance of the printed coupons. The effects of geometry parameters including porosity, surface outlet area ratio, and internal solid–fluid interface area ratio were investigated as well. The results showed that the transpiration cooling structures generally had higher cooling effectiveness than film cooling structure. The overall average cooling effectiveness of blood vessel-shaped transpiration cooling reached 0.35, 0.5, and 0.57, respectively, with low (1.2%), medium (2.4%), and high (3.6%) coolant injection ratios. The morphological parameters analysis showed the major factor that affected the cooling effectiveness most was the internal solid–fluid interface area ratio for transpiration cooling. This study showed that additive manufactured transpiration cooling could be a promising alternative method for turbine blade cooling and worthwhile for further investigations.

Engineering↗

Effects of Controlled Cooling-Induced Ferrite–Pearlite Microstructure on the Cold Forgeability of XC45 Steel

The combination of hot/warm and cold forging with an intermediate controlled cooling process is a promising approach to saving costs in the manufacture of automobile parts. In this work, the effects of the ferrite–pearlite microstructure, which formed after controlled cooling, on the cold forgeability of a medium-carbon steel were investigated. Different specimens for both normal and notched tensile tests were directly heated to high temperature and then cooled down at different cooling rates, producing different ferrite volume fractions, ranging from 6.69 to 40.53%, in the ferrite–pearlite microstructure. The yield strength, ultimate tensile strength, elongation rate, percentage reduction of area, and fracture strain were measured by tensile testing. The yield strength, indicating deformation resistance, and fracture strain, indicating formability, were used to evaluate the cold forgeability. As the ferrite volume fraction increased, the cold forgeability of the dual-phase ferritic–pearlitic steel improved. A quantitatively relationship between the ferrite volume fraction and the evaluation indexes of cold forgeability for XC45 steel was obtained from the test data. To validate the mathematical relationship, different tensile specimens machined from real hot-forged workpieces were tested. There was good agreement between the predicted and measured values. Our predictions from the relationship for cold forgeability had an absolute error less than 5%, which is acceptable for industrial applications and will help to guide the design of combined forging processes.

36 MATERIALS SCIENCE↗

Precipitation of aluminum nitride in a high strength maraging steel with low nitrogen content

In the present work, aluminum nitride (AlN) precipitation was investigated in a X23NiCoCrMoAl13-6-3 maraging steel with low nitrogen content (wt.% N = 5.5 ppm). A reliable and robust automatic method by scanning electron microscopy observations coupled with energy dispersive X-ray spectroscopy was developed for the quantification of AlN precipitates. The first stage was to identify the solvus temperature and to develop a heat treatment able to dissolve the AlN precipitates. The experimental determination of equilibrium conditions and solvus temperature show good agreement with ThermoCalc® simulation. Then, from this AlN-free state, the cooling rate, isothermal holding time and temperature were the subject of an intensive investigation in the austenite region of this maraging steel. In spite of the high temperatures used during heat treatments, the growth kinetic of the largest AlN precipitates (> 1 μm) is slow. The cooling rate has a major effect on the size and the number density of AlN due to a higher driving force for nucleation at low temperatures. At last, quenching prior to isothermal annealing at high temperatures leads to fine and dense AlN precipitation, resulting from the martensite to austenite transformation. Experimental results will be discussed and compared with kinetic data obtained with the mobility database MobFe2 implemented in Dictra® software. - Highlights: • Slow dissolution kinetic of AlN precipitates due to both their large size and small chemical driving force • Significant effects of cooling rate prior isothermal heat treatment, holding time and temperature on AlN precipitation • Size of AlN precipitates can be reduced by quenching prior isothermal holding. • Fine precipitation of AlN related to the α → γ transformation.

36 MATERIALS SCIENCE↗

Goertler vortices in supersonic boundary layers

The problem of Goertler vortices in compressible boundary layers over concave walls is studied by solving parabolic partial differential equations. The numerical scheme used is based upon a fourth-order accurate compact difference scheme. The results show that both the velocity and temperature fluctuations may lead to a Goertler vortex. The vortex growth rates determined from the present method are found to differ somewhat from those given by normal mode solution. The effects of cooling, heating and pressure gradient are also studied. At a Mach number of 3.5, cooling has a small destabilizing effect. The effect of adverse pressure gradient is also found to be destabilizing on a Mach 8 boundary layer.

Spall, R. E.↗

Plasma-induced collective effects in muon ionization cooling

Muon ionization cooling is a critical process that determines the achievable beam brightness and overall performance of a muon collider. In this study, we investigate collective effects induced by high-intensity muon beams inside the absorber, effects that have not been included in previous ionization cooling simulations. We show that beam-induced plasma can neutralize the beam space-charge field, while the self-generated azimuthal magnetic field can introduce additional beam focusing through a z-pinch-like mechanism. We also demonstrate that sufficiently high plasma densities may modify the stopping-power rate. The implications of these plasma-induced phenomena for ionization cooling performance are discussed.

Yonehara, Katsuya [Fermilab] (ORCID:00000002544041↗

Effect of packaging and cooling plates on mechanical response and failure characteristics of automotive Li-ion battery modules

When a battery pack is subjected to external mechanical load, i.e. as in the case of crash, the individual cells experience significant deformations leading to the internal short circuit and possibly fire. The current investigation looks into effects of the inactive components (i.e. cooling plates and module protective enclosure) on deformation and failure of individual pouch cells. Experiments on large spherical indentation of electric vehicle battery module with and without such components have been performed. The results show that the presence of cooling plates overall reduces the force under out-of-plane indentation by approximately a factor of 1.5. It was established however that the failure in cells occurs at the same displacement of the indenter, regardless of the presence of the inactive elements in battery module structure. This underlines the necessity for formulation of the failure criterion based on critical strain, rather than critical stress measure. The findings suggest possibility of utilizing such battery modules in impact energy absorption scenarios, due to reduction in force by the cooling components. X-Ray computed tomography (XCT) has been performed on the cells as a non-destructive analysis of internal failure and the differences of failure mode induced by introduction of structural components are discussed.

25 ENERGY STORAGE↗

Study of the effects of fuel vortex film cooling on high temperature coating durability

A report on the effects of fuel vortex film cooling on high temperature coating durability is presented. The program evaluated candidate high temperature oxidation resistant reaction control system engine thrust chamber material. As a result of the evaluation, the current and future programs may be optimized from the materials standpoint. Engine firing data for the evaluation of one material system is generated. The subjects considered are: (1) screening of materials, (2) thrust chamber fabrication, (3) engine testing, and (4) analysis of the data.

Source record↗

EFFECT OF A RADIATION COOLING AND HEATING FUNCTION ON STANDING LONGITUDINAL OSCILLATIONS IN CORONAL LOOPS

Standing long-period (with periods longer than several minutes) oscillations in large, hot (with a temperature higher than 3 MK) coronal loops have been observed as the quasi-periodic modulation of the EUV and microwave intensity emission and the Doppler shift of coronal emission lines, and they have been interpreted as standing slow magnetoacoustic (longitudinal) oscillations. Quasi-periodic pulsations of shorter periods, detected in thermal and non-thermal emissions in solar flares could be produced by a similar mechanism. We present theoretical modeling of the standing slow magnetoacoustic mode, showing that this mode of oscillation is highly sensitive to peculiarities of the radiative cooling and heating function. We generalized the theoretical model of standing slow magnetoacoustic oscillations in a hot plasma, including the effects of the radiative losses and accounting for plasma heating. The heating mechanism is not specified and taken empirically to compensate the cooling by radiation and thermal conduction. It is shown that the evolution of the oscillations is described by a generalized Burgers equation. The numerical solution of an initial value problem for the evolutionary equation demonstrates that different dependences of the radiative cooling and plasma heating on the temperature lead to different regimes of the oscillations, including growing, quasi-stationary, and rapidly decaying. Our findings provide a theoretical foundation for probing the coronal heating function and may explain the observations of decayless long-period, quasi-periodic pulsations in flares. The hydrodynamic approach employed in this study should be considered with caution in the modeling of non-thermal emission associated with flares, because it misses potentially important non-hydrodynamic effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Demand Shifting with Thermal Mass in Large Commercial Buildings in a California Hot Climate Zone

The potential for using building thermal mass for load shifting and peak energy demand reduction has been demonstrated in a number of simulation, laboratory, and field studies. Previous Lawrence Berkeley National Laboratory research has demonstrated that the approach is very effective in cool and moderately warm climate conditions (California Climate Zones 2-4). However, this method had not been tested in hotter climate zones. This project studied the potential of pre-cooling the building early in the morning and increasing temperature setpoints during peak hours to reduce cooling-related demand in two typical office buildings in hotter California climates ? one in Visalia (CEC Climate Zone 13) and the other in San Bernardino (CEC Climate Zone 10). The conclusion of the work to date is that pre-cooling in hotter climates has similar potential to that seen previously in cool and moderate climates. All other factors being equal, results to date indicate that pre-cooling increases the depth (kW) and duration (kWh) of the possible demand shed of a given building. The effectiveness of night pre-cooling in typical office building under hot weather conditions is very limited. However, night pre-cooling is helpful for office buildings with an undersized HVAC system. Further work is required to duplicate the tests in other typical buildings and in other hot climate zones and prove that pre-cooling is truly effective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effects of TiO opacity on the atmospheric structure of cool stars

A quantitative investigation is conducted concerning the effect of TiO opacities on the atmospheric temperature structure in late-type stars. Model atmospheres are computed, taking into account opacity-sampling (OS) or straight-mean (SM) opacities for three singlet and three triplet band systems of TiO. Model atmospheres using OS and SM opacities for TiO are compared with models having no TiO, giving attention to the effects of TiO opacities on the temperature structures of various atmospheres and the usefulness of straight-mean TiO opacities in model atmosphere calculations. The results of the model-atmosphere calculations are presented in two graphs. TiO opacities produce a global atmospheric heating which may reach several hundred kelvins. It is shown quantitatively that the TiO molecule is an important source of atmospheric opacity in cool stars of solar composition. The relative importance of TiO opacities to the thermal structure of a stellar atmosphere is influenced in the outer layers by CO and H2O cooling effects and in the deeper layers by CO, CN, and metal line absorption.

Krupp, B. M.↗

Optimization of concentrator photovoltaic solar cell performance through photonic engineering

The goal of this program was to incorporate two new and innovative design concepts into the design and production of CPV cells that have near zero added cost, yet significantly increase the operational efficiency of CPV modules. The program focused developing luminescent coupling effects and radiative cooling layers to increase efficiency and suppress CPV module power losses due to spectral variations and heating. The major results of the program were: 1) The optics of three commercial refractive (Fresnel) concentrators were characterized and prevent application of radiative cooling concepts due to strong mid-IR absorption (4-12µm) required to effectively radiate blackbody radiation from the cells and provide cooling. Investigation of alternative materials for the concentrator lenses produced only undesirable options—materials with reasonable mid-IR transmission for cooling only had about 30-40 visible transmission, thus reducing incident sunlight by >50%. While our investigation was somewhat limited, our work suggests that the only viable concentrator system that can incorporate radiative cooling utilizes reflective optics. 2) With limited ability to test high concentration CPV cells (requires outdoor testing), we acquired both semi-crystalline and crystalline Si cells and tested them in our outdoor facility and demonstrated 4°C cooling using a simple silica layer coating on the cells. 3) Characterizing Si cells in the IR associated with radiative cooling, we observed very significant near-IR absorption that increases the cell operating temperature by a similar amount, 4-5°C. By appropriate surface layer design, one can produce a layer that is highly reflective in the near-IR (1.5-4µm) and highly emissive in the mid-IR (5-15µm), thus reducing cell operational temperature by 10°C and increasing efficiency by ~1% absolute. The radiative cooling effect in c-Si solar cells might be further improved by providing a higher thermal conductive elastomer for securing the cover glass on top of the AR-coating. Since it was never imagined that the front surface would provide any cooling for solar cells, thermal conductivity of this elastomer was never a design consideration, but, improving the conductivity could decrease cell temperature by another 3-4°C. The combined effect could be an ~1.5% absolute increase in cell and module efficiency, a very significant improvement. 4) Developed a numerical model to explore dependence of luminescent coupling efficiency over a broad range of operating conditions. We developed a novel method and facility to experimentally measure the luminescent coupling that can be used to confirm the dependence of luminescent coupling on multi-junction cell design parameters.

14 SOLAR ENERGY↗

Effective properties of semitransparent radiative cooling materials with spectrally variable properties

Radiative cooling is a promising solid-state, non-vapor-compression technology for passive refrigeration and air conditioning. Although this phenomenon occurs naturally, achieving a significant amount of cooling to make it a technically and economically viable technology requires highly engineered, spectrally selective radiative surfaces. These characteristics make radiative cooling difficult to estimate, particularly when it is integrated with other systems such as photovoltaic panels or building envelopes. The complexity further increases when the substrate also participates in the radiative cooling (along with the radiative coating). Energy estimation is becoming increasingly critical because of the recent focus on the semitransparent radiative coatings that transmit a variety of colors to enhance the aesthetic appeal of the system. In this work, we propose an iterative method to calculate the effective radiative properties, which provides the same net radiative cooling that would be observed using the spectral properties at both the coating and substrate surfaces. Compared to traditional methods that rely on either computationally expensive full spectral analysis or methods for averaging each radiative surface parameter locally, our proposed method focuses on calculating effective properties that provide the same the net cooling effect as a full spectral analysis by accounting the emissivity, absorptivity, and transmissivity collectively, thereby providing an overall estimation error of less than 0.2%. We believe that this study will be beneficial to the engineering communities that employ complex simulation codes and require lumped solar and thermal radiation related parameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Turbine Endwalls for Deposition Resistance with 1400C Combustor Exit Temperatures and Syngas Water Vapor Levels

The primary objective of this multi-year research effort was to explore the possibility of modifying turbine endwall geometries to both increase their aerodynamic performance and reduce the potential for degradation due to deposition. The effort included both experimental and computational components. The experimental work was divided between two reacting flow turbine test facilities: one at BYU and the other at OSU. The facility at BYU was used for high temperature deposition experiments, up to 1400C with film cooling capability. The effects of particle size, surface temperature, gas temperature, and particle flowrate on deposition were all studied in the course of this research program. This facility was also adapted to allow elevated diluent (water vapor) concentrations. The OSU facility provided the capability to test actual turbine vane flowpaths at operating temperatures with film cooling. Effects of film cooling, particle size, gas temperature, and ash composition were all investigated. Experimental data from both facilities provided critical validation for computational models of deposition that were developed under this same research effort. Model development included the refinement of several existing particle sticking models and their incorporation into a commercial CFD package.

Bons, Jeffrey P.↗