At least 739 records · Page 41

Radioactivities in returned lunar materials and in meteorites

Carbon 14 terrestial ages were determined with low level minicomputers and accelerator mass spectrometry on 1 Yamato and 18 Allan Hills and nearby sited meteorites. Techniques for an accelerator mass spectrometer which make C(14) measurements on small samples were developed. Also Be(10) concentrations were measured in Byrd core and Allan Hills ice samples.

Fireman, E. L.↗

CORE SHAPES AND ORIENTATIONS OF CORE-SÉRSIC GALAXIES

The inner and outer shapes and orientations of core-Sérsic galaxies may hold important clues to their formation and evolution. We have therefore measured the central and outer ellipticities and position angles for a sample of 24 core-Sérsic galaxies using archival Hubble Space Telescope (HST) images and data. By selecting galaxies with core-Sérsic break radii R{sub b} —a measure of the size of their partially depleted core—that are ≳ 0.''2, we find that the ellipticities and position angles are quite robust against HST seeing. For the bulk of the galaxies, there is a good agreement between the ellipticities and position angles at the break radii and the average outer ellipticities and position angles determined over R {sub e}/2 < R < R {sub e}, where R {sub e} is the spheroids' effective half light radius. However there are some interesting differences. We find a median ''inner'' ellipticity at R{sub b} of ε{sub med} = 0.13 ± 0.01, rounder than the median ellipticity of the ''outer'' regions ε{sub med} = 0.20 ± 0.01, which is thought to reflect the influence of the central supermassive black hole at small radii. In addition, for the first time we find a trend, albeit weak (2σ significance), such that galaxies with larger (stellar deficit-to-supermassive black hole) mass ratios—thought to be a measure of the number of major dry merger events—tend to have rounder inner and outer isophotes, suggesting a connection between the galaxy shapes and their merger histories. We show that this finding is not simply reflecting the well known result that more luminous galaxies are rounder, but it is no doubt related.

79 ASTRONOMY AND ASTROPHYSICS↗

On the effects of filtering on convective-core statistics

Analysis of convective events north of Australia during the equatorial Monsoon Experiment (EMEX) reinforces accumulating evidence that convective cores over the tropical ocean are weak, with small diameters and vertical velocities. Superposition of smaller-scale turbulence on the convective core signal could yield artificially small cores, and thus produce sampling bias by aircraft. To investigate this potential source of bias, a side-by-side analysis of filtered and unfiltered vertical velocity data was performed while investigating the EMEX convective cores. Data were collected by the NOAA P3 and NCAR Electra using filtered (Graham filter) and non-filtered cores. The effects of filtering vertical velocity data to identify updraft and downdraft cores were noticeable but smaller than expected. Updraft cores had a vertical velocity greater than 1 m/sec for at least 500 m, and downdraft cores were defined analogously so that the filter eliminated events with less than a 500 m apparent diameter. Median and 10 percent core diameters were increased by 20-25 percent at most, with larger increases at higher levels (fewer small events). The maximum vertical velocity was changed only by changing the individual events in the distribution, but changes were detectable. At the lower levels, where many small, weak cores are introduced by filtering, average vertical velocity for the updraft cores was lowered by up to around 10 percent. Mass flux was changed the least, since diameter and mean vertical velocity respond to filtering in opposite ways. The filtering procedure increased total mass flux slightly due to inclusion of more upward moving air into the sample.

Lemone, Margaret A.↗

Single and multi-layered core-shell structures based on ZnO nanorods obtained by aerosol assisted chemical vapor deposition

Core–shell nanorod structures were prepared by a sequential synthesis using an aerosol assisted chemical vapor deposition technique. Several samples consisting of ZnO nanorods were initially grown over TiO{sub 2} film-coated borosilicate glass substrates, following the synthesis conditions reported elsewhere. Later on, a uniform layer consisting of individual Al, Ni, Ti or Fe oxides was grown onto ZnO nanorod samples forming the so-called single MO{sub x}/ZnO nanorod core–shell structures, where MO{sub x} was the metal oxide shell. Additionally, a three-layer core–shell sample was developed by growing Fe, Ti and Fe oxides alternately, onto the ZnO nanorods. The microstructure of the core–shell materials was characterized by grazing incidence X-ray diffraction, scanning and transmission electron microscopy. Energy dispersive X-ray spectroscopy was employed to corroborate the formation of different metal oxides. X-ray diffraction outcomes for single core–shell structures showed solely the presence of ZnO as wurtzite and TiO{sub 2} as anatase. For the multi-layered shell sample, the existence of Fe{sub 2}O{sub 3} as hematite was also detected. Morphological observations suggested the existence of an outer material grown onto the nanorods and further microstructural analysis by HR-STEM confirmed the development of core–shell structures in all cases. These studies also showed that the individual Al, Fe, Ni and Ti oxide layers are amorphous; an observation that matched with X-ray diffraction analysis where no apparent extra oxides were detected. For the multi-layered sample, the development of a shell consisting of three different oxide layers onto the nanorods was found. Overall results showed that no alteration in the primary ZnO core was produced during the growth of the shells, indicating that the deposition technique used herein was and it is suitable for the synthesis of homogeneous and complex nanomaterials high in quality and purity. In addition, materials absorptance determined from the total transmittance and reflectance spectra revealed a broader absorption interval including visible light, indicating potential uses of these nanostructures on solar energy appliances. - Graphical abstract: Display Omitted - Highlights: • Uniform ZnO nanorods (core)–metal oxide (shell) were obtained sequentially by AACVD. • Shells were structured of homogeneous single or multi-layered non-mixed metal oxides. • ZnO nanorod core was preserved during the shell synthesis. • Optical absorptance revealed visible interval absorption for FeO{sub x} shell samples. • Materials can be suitable for photocatalytic or photovoltaic applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Collection, Usage, and Preliminary Examination of the Apollo Sample Suite: Lessons for Artemis

Apollo Sample Collection and Usage: From 1969 to 1972 there were six Apollo missions to the surface of the Moon during which the astronauts collected 382 kg of rock and regolith (~2200 samples). The samples collected fall into these general categories: rocks (~66% by mass), rake samples (~4%), bulk regolith (~24%), and specialty regolith (deep drill cores, drive tubes, sealed bulk regolith) samples (~6%). In each category there are a variety of different subtypes available for study, e.g., among the bulk regolith samples there are also skim, trench, and (partially) shaded regolith samples each sampling unique types or depths of regolith. This variety of subsamples has enabled a multitude of different studies over the past 55 years (>3400 individual requests). We are still averaging ~50 unique requests and have allocated >500 individual Apollo samples annually for the past 10 years (2020 excepted). Looking at the 4,675 non-ANGSA (Apollo Next Generation Sample Analysis) samples allocated over the past 10 years, the proportions of allocated samples do not precisely align with the abundance (by mass) of those samples withing the collection: Rock (69.4 %); Rake (10.8 %); Bulk Regolith (15.5 %); Drive Tube (3.3 %); Core/Specialty (1.0 %). Apollo Preliminary Examination (PE): The PE process differs significantly for the various sample types enumerated above; we focus on regolith and rock samples here. During the Apollo mission era, the PE process evolved over the course of the missions; below is what was done for the Apollo 17 mission. For regolith samples, the PE process was: (1) documented bags containing regolith are opened, photographed, and described; (2) large rocks are removed and treated separately; (3) 25% to 33% of the bulk soil is scooped out, weighed, and stored in reserve; (4) the remaining sample is sieved to produce the size fractions <1, 1- 2, 2-4, and 4-10 mm, all of which are weighed. For rock samples, the process is: (1) removing rocks from the container(s) it came back from the Moon in; (2) rematching any materials that spalled off the rock to their original location; (3) numbering, weighing, and basic photographic documentation; (4) dusting with a gentle N2 gas jet; (5) Orthogonal photography; (6) detailed description of the textures and features of the rock; (7) rock modelling and measurement; (8) stereophotography; (9) determination of the orientation of the rock on the lunar surface. Drive tubes and deep drill cores were not characterized during PE beyond an initial weight and a sketch of the interior tube materials derived from 2D medical X-ray images. Catalogs: The ongoing utility of the Apollo samples is enabled by the robust cataloguing process for the samples [3-5], which allows the scientific community to accurately request samples uniquely suited to their proposed studies. A common misconception, however, is the amount of detail that goes into the initial catalog (e.g., [6]) for a collection from the preliminary examination (PE) period, versus what goes into the catalogs that come later in the life cycle of the samples from that mission (e.g., [7]). The only required data for a PE catalog is a weight, a basic photograph, and a description of the nature of the sample. Artemis PE: Over the past few years, the ongoing ANGSA project studied previously unopened Apollo 17 double drive tube samples 73001/2 [1], and a PE of the drive tubes was done. The PE took the existing core dissection process (developed during PE of Apollo cores in the 1970s, 1980s), and modernized it [7]. The main lesson from the ANGSA PE relative to future missions was that the physical work done during PE of lunar samples has not changed much over the past 5 decades. The use of “modern” technology during PE (e.g., XCT; multispectral analyses) resulted in an enhanced initial understanding of the 73001 and 73002 drive tubes, but greatly increased the time required. The lessons learned from recent astromaterial PEs (e.g., ANGSA and OREx) are important to consider when planning for Artemis, but the unique nature of the Artemis Campaign means many lessons learned from these mission will not be applicable. Given the time constraints (6 months) and likely number of samples that will be returned by Artemis (>200), the Artemis PE catalog will necessarily look much more like [4] than [6].

J Gross↗

Second group of irradiation capsules: property data of irradiated welded stainless steel 347 and irradiated, welded, and hydrogen charged Zircaloy-4 for SHINE

Zircaloy-4 and AISI 347 stainless steel were irradiated to low doses (10 20 and 10 21 n/cm 2 ) at low temperature (~60°C) in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). These materials were under consideration for some of the structural components of the medical isotope production facility developed by SHINE Technologies. Zircaloy-4 base metal, as welded, welded and post-weld heat treated (PWHT), and hydrogen charged samples were irradiated. AISI 347 base metal from Sandmeyer Steel, Penn Stainless, and Rolled Alloys suppliers were irradiated. AISI 347 gas tungsten arc welding (GTAW) and flux-cored arc welding (FCAW) samples of Penn Stainless and Rolled Alloys were also irradiated. The irradiated materials were tested with microhardness and tensile tests at room temperature in air. The AISI 347 materials had more elongation after irradiation than the Zircaloy-4 materials. In fact, the Zircaloy-4 welded without PWHT and with H charging had the lowest elongation of any of the materials. This report is the final in a series of reports on this project.

36 MATERIALS SCIENCE↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

36 MATERIALS SCIENCE↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

Portable chemical detection platform for on-site monitoring of odorant levels in natural gas

The adequate odorization of natural gas is critical to identify gas leaks and to reduce accidents. To ensure odorization, natural gas utility companies collect samples to be processed at core facilities or a trained human technician smells a diluted natural gas sample. In this work, we report a detection platform that addresses the lack of mobile solutions capable of providing quantitative analysis of mercaptans, a class of compounds used to odorize natural gas. Detailed description of the platform hardware and software components is provided. Designed to be portable, the platform hardware facilitates extraction of mercaptans from natural gas, separation of individual mercaptan species, and quantification of odorant concentration, with results reported at point-of-sampling. The software was developed to accommodate skilled users as well as minimally trained operators. Detection and quantification of six commonly used mercaptan compounds (ethyl mercaptan, dimethyl sulfide, n-propylmercaptan, isopropyl mercaptan, tert–butyl mercaptan, and tetrahydrothiophene) at typical odorizing concentrations of 0.1–5 ppm was performed using the device. We demonstrate the potential of this technology to ensure natural gas odorizing concentrations throughout distribution systems.

03 NATURAL GAS↗

Large-scale replicated field study of maize rhizosphere identifies heritable microbes

Up until now, soil microbes that colonize plant roots and are responsive to differences in plant genotype remain to be ascertained for agronomically important crops. From a very large-scale longitudinal field study of 27 maize inbred lines planted in three fields, with partial replication 5 y later, we identify root-associated microbiota exhibiting reproducible associations with plant genotype. Analysis of 4,866 samples identified 143 operational taxonomic units (OTUs) whose variation in relative abundances across the samples was significantly regulated by plant genotype, and included five of seven core OTUs present in all samples. Plant genetic effects were significant amid the large effects of plant age on the rhizosphere microbiome, regardless of the specific community of each field, and despite microbiome responses to climate events. Seasonal patterns showed that the plant root microbiome is locally seeded, changes with plant growth, and responds to weather events. However, against this background of variation, specific taxa responded to differences in host genotype. If shown to have beneficial functions, microbes may be considered candidate traits for selective breeding.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative Results of Using Different Methods for Discovery of Microorganisms in very Ancient Layers of the Central Antarctic Glacier above the Lake Vostok

The ice sheet of the Central Antarctic is considered by the scientific community worldwide, as a model to elaborate on different methods to search for life outside Earth. This became especially significant in connection with the discovery of the underglacial lake in the vicinity of the Russian Antarctic Station Vostok. Lake Vostok is considered by many scientists as an analog of the ice covered seas of Jupiter's satellite Europa. According to the opinion of many researchers there is the possibility that relict forms of microorganisms, well preserved since the Ice Age, may be present in this lake. Investigations throughout the thickness of the ice sheet above Lake Vostok show the presence of microorganisms belonging to different well-known taxonomic groups, even in the very ancient horizons near close to floor of the glacier. Different methods were used to search for microorganisms that are rarely found in the deep ancient layers of an ice sheet. The method of aseptic sampling from the ice cores and the results of controlled sterile conditions in all stages when conducting these investigations, are described in detail in previous reports. Primary investigations tried the usual methods of sowing samples onto different nutrient media, and the result was that only a few microorganisms grew on the media used. The possibility of isolating the organisms obtained for further investigations, by using modern methods including DNA-analysis, appears to be the preferred method. Further investigations of the very ancient layers of the ice sheet by radioisotopic, luminescence, and scanning electron microscopy methods at different modifications, revealed the quantity and morphological diversity of the cells of microorganisms that were distributed on the different horizons. Investigations over many years have shown that the microflora in the very ancient strata of the Antarctic ice cover, nearest to the bedrock, support the effectiveness of using a combination of different methods to search for signs of life in ancient icy formations, which might play a role in the long-term preservation and transportation of microbial life throughout the Universe.

Abyzov, S. S.↗

Local Resistance Measurement for Degradation of c-Si Heterojunction with Intrinsic Thin Layer (HIT) Solar Modules

Silicon heterojunction with intrinsic thin layer (or HIT) modules typically degrade at a rate of less than 1% annually in solar fields with dominant degradation in open-circuit voltage and some degradation in series resistance. However, detailed mechanisms can differ from module to module. Here, we study increases in local series resistance that occur over long-term field deployment, indicated by cell areas where the photoluminescence intensity does not degrade but the electroluminescence degrades significantly. To directly measure the local series resistance, we have cored out the local electroluminescence-degraded area, and we measured the sheet resistance by 4-point-probe and local nm-scale resistance using scanning spreading resistance microscopy (SSRM). The results by 4-point-probe show scattered sheet resistance that can be caused, for example, by nonuniform current paths through the transparent conductive oxide layer, the a-Si:H emitter, or the near-junction c-Si inversion layer. In contrast, the SSRM results indicate a relatively uniform and non-degraded resistivity on smaller nanometer spatial scales. SSRM is an atomic force microscopy-based two-terminal resistance mapping technique that measures the local resistance in nm-volume beneath the probe. The consistent resistances measured on the control and degraded samples can exclude the degradation of transparent conductive oxide resistance.

41 EE - Solar Energy Technologies Office (EE-4S)↗

WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021 Version 2.0

This submission includes an update to the WHOLESCALESamples2021January.xls file where the strikes and dips initially reported have been corrected to comply with the right hand rule. The updated excel file and a link to the original submission are included in this report. The original submission "WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021" contains information on thirty-six rock samples collected from San Emidio, Nevada during January, 2021 for Subtask 2.3 of the WHOLESCALE project. The following resources include a .zip of rock sample photos taken in the field, a .zip of rock sample photos taken in the laboratory at UW-Madison, and an excel catalog of rock samples with information on sample name, rock type, coordinates of sample location, structural measurements, field notes, observations for plug preparation (e.g., weathering, ability to be cut and cored), and rock descriptions. It should be noted that not every sample was photographed in the field. Names and descriptions of rock formation units are taken from Rhodes et al. (2011). The README.txt file is a description of this submission.

15 GEOTHERMAL ENERGY↗

WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021

This submission contains information on thirty-six rock samples collected from San Emidio, Nevada during January, 2021 for Subtask 2.3 of the WHOLESCALE project. The following resources include a .zip of rock sample photos taken in the field, a .zip of rock sample photos taken in the laboratory at UW-Madison, and an excel catalog of rock samples with information on sample name, rock type, coordinates of sample location, structural measurements, field notes, observations for plug preparation (e.g., weathering, ability to be cut and cored), and rock descriptions. It should be noted that not every sample was photographed in the field. Names and descriptions of rock formation units are taken from Rhodes et al. (2011). The README.txt file is a description of this submission.

15 GEOTHERMAL ENERGY↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

The Impact of Freeze‐Thaw History on Soil Carbon Response to Experimental Freeze‐Thaw Cycles

Abstract Freeze‐thaw is a disturbance process in cold regions where permafrost soils are becoming vulnerable to temperature fluctuations above 0°C. Freeze‐thaw alters soil physical and biogeochemical properties with implications for carbon persistence and emissions in Arctic landscapes. We examined whether different freeze‐thaw histories in two soil systems led to contrasting biogeochemical responses under a laboratory‐controlled freeze‐thaw incubation. We investigated controls on carbon composition through Fourier‐transform ion cyclotron resonance mass spectrometry (FT‐ICR‐MS) to identify nominal carbon oxidation states and relative abundances of aliphatic‐type carbon molecules in both surface and subsurface soils. Soil cores (∼60 cm‐depth) were sampled from two sites in Alaskan permafrost landscapes with different in situ freeze‐thaw characteristics: Healy (>40 freeze‐thaw cycles annually) and Toolik (<15 freeze‐thaw cycles annually). FT‐ICR‐MS was coupled with in situ temperature data and soil properties (i.e., soil texture, mineralogy) to assess (a) differences in soil organic matter composition associated with previous freeze‐thaw history and (b) sensitivity to experimental freeze‐thaw in the extracted cores. Control (freeze‐only) samples showed greater carbon oxidation in Healy soils compared with Toolik, even in lower mineral horizons where freeze‐thaw history was comparable across both sites. Healy showed the most loss of carbon compounds following experimental freeze‐thaw in the lower mineral depths, including a decrease in aliphatics. Toolik soils responded more slowly to freeze‐thaw as shown by intermediary carbon oxidation distributed across multiple carbon compound classes. Variations in the response of permafrost carbon chemistry to freeze‐thaw is an important factor for predicting changes in soil function as permafrost thaws in high northern latitudes.

Rooney, Erin C.↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗