Investigation of the effect of low energy ion beam irradiation on mono-layer graphene

In this paper, the effect of low energy irradiation on mono-layer graphene was studied. Mono-layer graphene films were irradiated with B, N and F ions at different energy and fluence. X-ray photoelectron spectroscopy indicates that foreign ions implanted at ion energies below 35 eV could dope into the graphene lattice and form new chemical bonds with carbon atoms. The results of Raman measurement indicate that ion beam irradiation causes defects and disorder to the graphene crystal structure, and the level of defects increases with increasing of ion energy and fluence. Surface morphology images also prove that ion beam irradiation creates damages to graphene film. The experiment results suggest that low-energy irradiation with energies of about 30 eV and fluences up to 5·10{sup 14} cm{sup −2} could realize small amount of doping, while introducing weak damage to graphene. Low energy ion beam irradiation, provides a promising approach for controlled doping of graphene.

36 MATERIALS SCIENCE↗

Overview of High-Resolution Nondestructive Inspection of the Space Shuttle External Tank (ET) Spray-on-Foam Insulation (SOFI) and Acreage Heat tiles using Focused, Synthetic and Holographical Millimeter Wave Techniques

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank (ET) and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the recent Space Shuttle Discovery's flight. From immediately after the Columbia accident, microwave and millimeter wave nondestructive testing methods were considered as potential effective inspection tools for evaluating the integrity of the SOFI. To this end and as a result of these efforts, both real-focused, synthetic focusing and holographical techniques, at a wide range of frequencies covering 24 GHz to 150 GHz, have been developed for this purpose. Images of various complex SOFI panels with a wide range of embedded anomalies (representing real potential defects) have been produced using these techniques, including relatively small anomalies located near complex structural features representative of the external tank. These real-focused and 3D holographical images have effectively demonstrated the utility of these methods for SOFI inspection as being viable, robust, repeatable, simple, portable and relatively inexpensive (tens of $K as opposed to hundreds of $K). In addition, the potential viability of these methods for inspecting acreage heat tiles have has been demonstrated. This paper presents an overview of these activities, representative images of these panels using all of the imaging techniques used and a discussion of the practical attributes of these inspection methods.

Kharkovsky, S.↗

Role of defects in ultra-high gain in fast planar tin gallium oxide UV-C photodetector by MBE

Here we report ultra-high responsivity of epitaxial (Sn x Ga 1–x ) 2 O 3 (TGO) Schottky UV-C photodetectors and experimentally identified the source of gain as deep-level defects, supported by first principles calculations. Epitaxial TGO films were grown by plasma-assisted molecular beam epitaxy on (–201) oriented n-type β-Ga 2 O 3 substrates. Fabricated vertical Schottky devices exhibited peak responsivities as high as 3.5 ×10 4 A/W at –5 V applied bias under 250 nm illumination with sharp cutoff shorter than 280 nm and fast rise/fall time in milliseconds order. Hyperspectral imaging cathodoluminescence (CL) spectra were examined to find the mid-bandgap defects, the source of this high gain. Irrespective of different tin mole fractions, the TGO epilayer exhibited extra CL peaks at the green band (~2.20 eV) not seen in β-Ga 2 O 3 along with enhancement of the blue emission-band (~2.64 eV) and suppression of the UV emission-band. Based on hybrid functional calculations of the optical emission expected for defects involving Sn in β-Ga 2 O 3 , V Ga –Sn complexes are proposed as potential defect origins of the observed green and blue emission-bands. Such complexes behave as acceptors that can efficiently trap photogenerated holes and are predicted to be predominantly responsible for the ultra-high photoconductive gain in the Sn-alloyed Ga 2 O 3 devices by means of thermionic emission and electron tunneling. Regenerating the V Ga –Sn defect complexes by optimizing the growth techniques, we have demonstrated a planar Schottky UV-C photodetector of the highest peak responsivity.

36 MATERIALS SCIENCE↗

Compositional and Structural Study of Gd Implanted ZnO Films

We report a compositional and structural study of ZnO films implanted with 30 keV Gd ions. The depth profile of the implanted ions, measured by Rutherford backscattering spectrometry, matches predictions of DYNAMIC-TRIM calculations. However, after annealing at temperatures above 550 deg. C the Gd ions are observed to migrate towards the bulk, and at the same time atomic force microscope images of the film surfaces show significant roughening. Raman spectroscopy shows that the annealed films have a reduced number of crystalline defects. The overall results are useful for developing an implantation-annealing regime to produce well characterized samples to investigate magnetism in the ZnO:Gd system.

36 MATERIALS SCIENCE↗

Recombination imaging of III-V solar cells

An imaging technique based on the radiative recombination of minority carriers in forward-biased solar cells has been developed for characterization of III-V solar cells. When used in mapping whole wafers, it has helped identify three independent loss mechanisms (broken grid lines, shorting defects, and direct-to-indirect bandgap transitions), all of which resulted in lower efficiencies. The imaging has also led to improvements in processing techniques to reduce the occurrence of broken gridlines as well as surface defects. The ability to visualize current mechanisms in solar cells is an intuitive tool which is powerful in its simplicity.

Virshup, G. F.↗

Imaging of a van der Waals spin-orbit torque system using spin ensembles in hBN

Recently, optically active spin defects embedded in two-dimensional (2D) van der Waals (vdW) crystals have emerged as a transformative quantum sensing platform to explore cutting-edge materials science. Taking advantage of excellent solid-state integrability, this new class of spin defects can be readily arranged in nanoscale proximity to target materials, showing great promise for realizing in-situ quantum sensing of microscopic spin and charge behaviors in vdW heterostructures. Here we report hexagonal boron nitride-based quantum imaging of field-free deterministic magnetic switching and electric current distributions in an all-vdW spin-orbit torque (SOT) system. By visualizing variations of nanoscale magnetic stray field profile of room-temperature 2D magnet Fe 3 GaTe 2 under different SOT conditions, we show how the magnetic switching evolves from deterministic to stochastic behavior due to the interplay between spin orientations, anisotropy and Joule heating. Micromagnetic simulations rationalize our results well, revealing the role of field-like SOT in inhibiting thermal fluctuation driven stochastic switching and chaotic multi-domain competition. This understanding, which is otherwise difficult to access by conventional transport measurements, offers valuable insights into material design, testing, and performance evaluation of next-generation vdW spintronic devices.

Imaging techniques↗

Effect of flask vibration time on casting integrity, Surface Penetration and Coating Inclusion in lost foam casting of Al-Si Alloy

The paper presents the result of an experimental investigation conducted on medium aluminum silicon alloy casting- LM6, using no-vacuum assisted lost foam casting process. The study is directed for establishing the relationship between the flask vibrations times developed for molded sample on the casting integrity, surface penetration and coating inclusion defects of the casting. Four different flask vibration times namely 180, 120, 90 and 60 sec. were investigated. The casting integrity was investigated in terms of fulfilling in all portions and edges. The surface penetration was measured using optical microscope whilst image analyzer was used to quantify the percentage of coating inclusion in the casting. The results show that vibration time has significant influence on the fulfilling as well as the internal integrity of the lost foam casting. It was found that the lower vibration time produced comparatively sound casing.

36 MATERIALS SCIENCE↗

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

Aim: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF). Methods: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting {sup 99m}Tc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and {sup 18}F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually. Results: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT. Conclusion: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Emitters Induced by High Pressure and UV Laser Irradiation in Multilayer GaSe

In this work, we report on defect generation in multilayer GaSe through hydrostatic pressure quenching and UV laser irradiation. The Raman line width from the UV 266 nm irradiated sample is much wider than that in pressure-quenched GaSe, corresponding to a wider defect energy distribution range in the former sample than the latter. After quenching from 11.2 GPa, three photoluminescence (PL) peaks from defect states are observed at 657, 681, and 695 nm at a low temperature of 93 K. Defect-related peaks at 649, 694, 750, and 774 nm also appear in low-temperature PL spectra after UV laser irradiation, with a nonmonotonous intensity dependence on irradiation duration. There are common features in defects produced by these two methods: the PL peaks with the lowest energy are sharp, and their PL intensities increase linearly with the excitation laser power and saturate above a certain excitation laser power. These two features are similar to those in defects for single-photon emission (SPE) in other 2D materials at even lower temperatures. Fluorescence lifetime imaging shows distinguished short (2.3 ns) and long (75.6 nm) lifetimes of the 695 nm PL line in pressure-quenched GaSe. The density functional theory predicts defect energy levels related to Se vacancy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of a novel load-bearing trabecular Nitinol scaffold on rabbit radius bone regeneration

The research aim was to evaluate the bone regeneration capability of novel load-bearing NiTi alloy (Nitinol) scaffolds in a critical-size defect (CSD) model. High strength “trabecular Nitinol” scaffolds were prepared by PIRAC (Powder Immersion Reaction Assisted Coating) annealing of the highly porous Ni foam in Ti powder at 900°C. This was followed by PIRAC nitriding to mitigate the release of potentially toxic Ni ions. Scaffolds phase composition and microstructure were characterized by X-ray diffraction and scanning electron microscopy (SEM/EDS), and their mechanical properties were tested in compression. New Zealand white rabbits received bone defect in right radius and were divided in four groups randomly. In the control group, nothing was placed in the defect. In other groups, NiTi scaffolds were implanted in the defect: (i) as produced, (ii) loaded with bone marrow aspirate (BMA), and (iii) biomimetically CaP-coated. The animals were sacrificed after 12 weeks. The forelimbs with scaffolds were resected, fixed, sectioned and examined in SEM. New bone formation inside the scaffold was studied by EDS analysis and by the processing of backscattered electron images. Bone ingrowth into the scaffold was observed in all implant groups, mostly next to the ulna. New bone formation was strongly enhanced by BMA loading and biomimeatic CaP coating, the bone penetrating as much as 1–1.5 mm into the scaffold. The results of this preliminary study demonstrate that the newly developed high strength trabecular Nitinol scaffolds can be successfully used for bone regeneration in critical size defects.

36 MATERIALS SCIENCE↗

Microwave and Millimeter Wave Imaging Using Synthetic Aperture Focusing and Holographical Techniques

Microwave and millimeter wave nondestructive testing and evaluation (NDT&E) methods have shown great potential for determining material composition in composite structures, determining material thickness or debond thickness between two layers, and determining the location and size of flaws, defects, and anomalies. The same testing methods have also shown great potential to produce relatively high-resolution images of voids inside Spray On Foam Insulation (SOFI) test panels using real focused methods employing lens antennas. An alternative to real focusing methods are synthetic focusing methods. The essence of synthetic focusing is to match the phase of the scattered signal to measured points spaced regularly on a plane. Many variations of synthetic focusing methods have already been developed for radars, ultrasonic testing applications, and microwave concealed weapon detection. Two synthetic focusing methods were investigated; namely, a) frequency-domain synthetic aperture focusing technique (FDSAFT), and b) wide-band microwave holography. These methods were applied towards materials whose defects were of low dielectric contrast like air void in SOFI. It is important to note that this investigation used relatively low frequencies from 8.2 GHz to 26.5 GHz that are not conducive for direct imaging of the SOFI. The ultimate goal of this work has been to demonstrate the capability of these methods before they are applied to much higher frequencies such as the millimeter wave frequency spectrum (e.g., 30-300 GHz).

Case, Joseph Tobias↗

Lateral epitaxial growth of germanium on silicon oxide

We have developed a method using local oxidation on silicon to create nanoscale silicon seeds for the lateral epitaxial overgrowth of germanium on silicon oxide. The germanium growth starts selectively from silicon seed lines, proceeds by wetting the SiO{sub 2} layer and coalesces without formation of grain boundary. Analysis by high resolution transmission electron microscopy have shown that Ge layers grown above silicon oxide are perfectly monocrystalline and are free of defect. The only detected defects are situated at the Ge/Si interface. Geometrical phase analyses of the microscopy images have shown that the Ge layer is fully relaxed and homogeneous.

36 MATERIALS SCIENCE↗

Atomic electrostatic maps of 1D channels in 2D semiconductors using 4D scanning transmission electron microscopy

Defects in materials give rise to fluctuations in electrostatic fields that reflect the local charge density, but imaging this with single atom sensitivity is challenging. However, if possible, this provides information about the energetics of adatom binding, localized conduction channels, molecular functionality and their relationship to individual bonds. Here, ultrastable electron-optics are combined with a high-speed 2D electron detector to map electrostatic fields around individual atoms in 2D monolayers using 4D scanning transmission electron microscopy. Simultaneous imaging of the electric field, phase, annular dark field and the total charge in 2D MoS 2 and WS 2 is demonstrated for pristine areas and regions with 1D wires. The in-gap states in sulphur line vacancies cause 1D electron-rich channels that are mapped experimentally and confirmed using density functional theory calculations. We show how electrostatic fields are sensitive in defective areas to changes of atomic bonding and structural determination beyond conventional imaging.

36 MATERIALS SCIENCE↗

WE-AB-202-05: Validation of Lung Stress Maps for CT-Ventilation Imaging

Purpose: To date, lung CT-ventilation imaging has been based on quantification of local breathing-induced changes in Hounsfield Units (HU) or volume. This work investigates the use of a stress map resulting from a biomechanical deformable image registration (DIR) algorithm as a metric of the ventilation function. Method: Eight lung cancer patients presenting different kinds of ventilation defects were retrospectively analyzed. Additionally, to the 4DCT acquired for radiotherapy planning, five of them had PET and three had SPECT imaging following inhalation of Ga-68 and Tc-99m, respectively. For each patient, the inhale phase of the 4DCT was registered to the exhale phase using Morfeus, a biomechanical DIR algorithm based on the determination of boundary conditions on the lung surfaces and vessel tree. To take into account the heterogeneity of the tissue stiffness in the stress map estimation, each tetrahedral element of the finite-element model was assigned a Young’s modulus ranging from 60kPa to 12MPa, as a function of the HU in the inhale CT. The node displacements and element stresses resulting from the numerical simulation were used to generate three CT-ventilation maps based on: (i) volume changes (Jacobian determinant), (ii) changes in HU, (iii) the maximum principal stress. The voxel-wise correlation between each CT-ventilation map and the PET or SPECT V image was computed in a lung mask. Results: For patients with PET, the mean (min-max) Spearman correlation coefficients r were: 0.33 (0.19–0.45), 0.36 (0.16–0.51) and 0.42 (0.21–0.59) considering the Jacobian, changes in HU and maximum principal stress, respectively. For patients with SPECT V, the mean r were: 0.12 (−0.12–0.43), 0.29 (0.22–0.45) and 0.33 (0.25–0.39). Conclusion: The maximum principal stress maps showed a stronger correlation with the ventilation images than the previously proposed Jacobian or change in HU maps. This metric thus appears promising for CT-ventilation imaging. This work was funded in part by NIH P01CA059827.

60 APPLIED LIFE SCIENCES↗

Image gathering and digital restoration for fidelity and visual quality

The fidelity and resolution of the traditional Wiener restorations given in the prevalent digital processing literature can be significantly improved when the transformations between the continuous and discrete representations in image gathering and display are accounted for. However, the visual quality of these improved restorations also is more sensitive to the defects caused by aliasing artifacts, colored noise, and ringing near sharp edges. In this paper, these visual defects are characterized, and methods for suppressing them are presented. It is demonstrated how the visual quality of fidelity-maximized images can be improved when (1) the image-gathering system is specifically designed to enhance the performance of the image-restoration algorithm, and (2) the Wiener filter is combined with interactive Gaussian smoothing, synthetic high edge enhancement, and nonlinear tone-scale transformation. The nonlinear transformation is used primarily to enhance the spatial details that are often obscurred when the normally wide dynamic range of natural radiance fields is compressed into the relatively narrow dynamic range of film and other displays.

Huck, Friedrich O.↗

Origin of micrometer-scale dislocation motion during hydrogen desorption

Hydrogen, while being a potential energy solution, creates arguably the most important embrittlement problem in high-strength metals. However, the underlying hydrogen-defect interactions leading to embrittlement are challenging to unravel. Here, we investigate an intriguing hydrogen effect to shed more light on these interactions. By designing an in situ electron channeling contrast imaging experiment of samples under no external stresses, we show that dislocations (atomic-scale line defects) can move distances reaching 1.5 μm during hydrogen desorption. Combining molecular dynamics and grand canonical Monte Carlo simulations, we reveal that grain boundary hydrogen segregation can cause the required long-range resolved shear stresses, as well as short-range atomic stress fluctuations. Thus, such segregation effects should be considered widely in hydrogen research.

36 MATERIALS SCIENCE↗

Non-Destructive In-Process Assessment of Thermal Spray Repairs

This exploratory project, entitled “Non-Destructive In-process Assessment of Thermal Spray Repairs,” evaluated the capabilities and limitations of four non-destructive testing (NDE) technologies for detection of defects in as-sprayed thermal spray coatings: acousto-ultrasonics, vibro-thermography, thermal wave infrared (IR) imaging, and flash IR thermography. The project goal was to identify a single technology suitable for use as an in-process inspection for two common classes of defects in thermal spray coatings, porosity and disbonds. Two rounds of test coupons were fabricated with intentionally seeded defects in AISI 420 stainless steel coatings deposited by twin wire arc (TWA) spray onto gray cast iron substrates. These standardized test coupons allowed the sensitivity of the four NDE methods to be directly compared. The results indicated that the acousto-ultrasonic method will not meet requirements for accuracy, inspection time, and reproducibility, while the vibrothermography method will not meet requirements for integration within remanufacturing cells and process flows. The IR methods, thermal wave imaging and flash thermography, both exhibited acceptable accuracy and reproducibility; however, the former method does not meet the requirement for inspection time. Flash IR thermography met all requirements in the initial round of testing, and that result was confirmed in a second round of testing on samples with a larger, more complex geometry. A final recommendation for further development of flash IR thermography was therefore made based upon i) detection performance, and ii) feasibility of deployment into the target application of resurfacing CAT engine blocks and headers.

36 MATERIALS SCIENCE↗