Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Tagging CO 2 to Enable Quantitative Inventories of Geological Carbon Storage

In the wake of concerns about the long term integrity and containment of sub-surface CO 2 sequestration reservoirs, many efforts have been made to improve the monitoring, verification, and accounting methods for geo-sequestered CO 2 . Our project aimed to demonstrate the feasibility of a system designed to tag CO 2 with carbon isotope 14 C immediately prior to sequestration to a level that is normal on the surface (one part per trillion). Because carbon found at depth is naturally free of 14 C, this tag would easily differentiate pre-existing carbon from anthropogenic injected carbon and provide an excellent handle for monitoring its whereabouts in the subsurface. It also creates an excellent handle for adding up anthropogenic carbon inventories. Future inventories in effect count 14 C atoms. Accordingly, we have developed a 14 C tagging system suitable for use at the part-per-trillion level. This system consists of a gas-exchange apparatus to make disposable cartridges ready for controlled injection into a fast flowing stream of pressurized CO 2 . We built a high-pressure injection and tagging system, and a 14 C detection system. The disposable cartridge and injection system have been successfully demonstrated in the lab with a high-pressure flow reactor, as well as in the field at the CarbFix CO 2 sequestration site in Iceland. The laser-based 14 C detection system originally conceived has been shown to possess inadequate sensitivity for ambient levels. Alternative methods for detecting 14 C, such as saturated cavity absorption ringdown spectroscopy and scintillation counting, may still be suitable.

anthropogenic carbon↗

DHS Regional Reachback: Rapid Expert Radiation Alarm Assistance

Following assessments that attacks with radiological and nuclear weapons are possible or even likely, detection system deployments are being supported at National and local levels. Detection systems include highly sensitive but non-discriminating detectors, as well as detectors and algorithms capable of distinguishing and identifying gamma rays by energy. The latter systems, usually handheld systems based on sodium iodide detectors, also provide analysis of the specific radionuclides present, and are referred to as radioisotope identifiers (RIIDs). Studies have shown that sodium iodide based RIIDs fall far short of 100% accurate identifications. The US Department of Homeland Security initiated the Regional Reachback (RRB) Program in 2006 to provide rapid expert interpretation of gamma spectroscopic data from radiation alarms from detection systems deployed by State and Local authorities. With expert specialists on call 24/7, RRB provides an avenue for Local and state Authorities to verify routine results, interpret unknown identifications, and notify national response assets if needed. Contact with RRB is through the DHS Joint Analysis Center (JAC), which functions as a fusion node for data correlation, transmittal, and analysis. After initial phone contacts, State/Local authorities transmit spectral data and incident information via e-mail or secure website. The JAC alerts the on-call RRB specialists, who are expected to provide an analysis within 30 minutes. This paper will provide details of the RRB program, an outline of the analysis process, a description of the drills and training systems used to maintain specialists response performance, and examples of drills and incidents from the first full year of operation.

Bowerman, Biasys↗

Precise stress measurements with white synchrotron x rays

In situ measurement of stress in polycrystalline samples forms the basis for studies of the mechanical properties of materials with very broad earth science and materials science applications. Synchrotron x rays have been used to define the local elastic strain in these samples, which in turn define stress. Experimental work to date has been carried out on a prototype detection system that provided a strain measurement precision >10{sup -4}, which corresponds to a stress resolution >50 MPa for silicate minerals. Here we report operation of a new, permanent, energy dispersive detection system for white radiation, which has been developed at the National Synchrotron Light Source. The new system provides differential strain measurements with a precision of 3x10{sup -5} for volumes that are 50x50x500 {mu}m{sup 3}. This gives a stress precision of about 10 MPa for silicate minerals.

36 MATERIALS SCIENCE↗

AviSense: A Real-time System for Detection, Classification, and Analysis of Aviation Signals

Wireless systems are an integral part of aviation. Apart from their apparent use in air-to-ground communication, wireless systems play a crucial role in avionic functions including navigation and landing. An interference-free wireless environment is therefore critical for the uninterrupted operation and safety of an aircraft. Hence, there is an urgency for airport facilities to acquire the capability to continuously monitor aviation frequency bands for real-time detection of interference and anomalies. To meet this critical need, we design and build AviSense, an SDR-based real-time, versatile system for monitoring aviation bands. AviSense detects and characterizes signal activities to enable practical and effective anomaly detection. We identify and tackle the challenges posed by a diverse set of critical aviation bands and technologies. We evaluate our methodology with real-world aviation signal measurements and two custom datasets of anomalous signals. We find that our signal classification capability achieves a true positive rate of ~99%, with few exceptions, and a false positive rate of less than 4%. We also demonstrate that AviSense can effectively distinguish between different types of anomalies. We build and evaluate a prototype implementation of AviSense that supports distributed monitoring.

42 ENGINEERING↗

Importance of Contrast-to-Noise Ratio Sensitivity Function in Nondestructive Evaluation

A reliable nondestructive evaluation (NDE) technique provides minimum 90% probability of detection (POD) with 95% confidence for detection of cracklike flaws of a specific size. This requirement comes from fracture control. Fracture control is a risk assessment and control approach for preventing structural failure of fracture critical hardware during its service life. One of the approaches of fracture control is damage tolerance safe life analysis, which assumes that NDE reliably detectable size flaw may exist in the hardware post nondestructive evaluation. Analysis and/or testing are performed to verify that the hardware will not fail during its service life despite existence of such a flaw. NDE methods are conventionally qualified by probability of detection (POD) demonstration testing to ensure reliable flaw detection. Here, a novel and alternative to POD flaw detection reliability approach that uses contrast-to-noise ratio (CNR) is given. The approach uses CNR sensitivity function (SF) and CNR. CNR SF is the minimum CNR needed for reliable flaw detection as a function of certain flaw indication characteristics. Primary difference between POD approaches and CNR flaw detection reliability approach is resolution of flaw detection system. POD approach does not account for the resolution of the system, while CNR approach accounts for the flaw detection resolution. Resolution is determined from the modulation transfer function (MTF) of the flaw detection system. CNR flaw detection reliability approach emphasizes quantitative assessment of “how well each flaw indication is detected”. Therefore, CNR approach is helpful in reducing number of flaws in the sample used in NDE procedure qualification, resulting in cost and time savings. CNR approach is also a case of multi-hit flaw detection analysis which has better flaw detectability size than conventional single-hit flaw detectability. Thus, CNR approach, where applicable, may be superior to conventional POD approach. The paper is an overview of development of CNR modeling, CNR SF modeling and measurement by the author. The paper gives key references to currently used NDE procedure POD qualification approaches including those specific to CNR and CNR SF development in multi-hit flaw detection in NDE. The paper covers core topics in nondestructive evaluation engineering.

Contrast-to-noise ratio↗

Autonomous Sensor System for Wind Turbine Blade Collision Detection

This paper presents an automated blade collision detection system for use on wind turbines, toward the goal of supporting monitoring and quantitative assessment of wind energy impacts on wildlife. A wireless, multisensor module mounted at the blade root measures surface vibrations, and a blade-mounted camera provides image capture of colliding objects. Using sensor data recorded during field testing of the system on an operational wind turbine, we present the development, training, and testing of automated detection algorithms for collision detection using machine-learning approaches. In particular, we compare the use of a new two-step, anomaly-based classification algorithm with conventional adaptive boosting and amplitude-based detection techniques, where the two-step approach improves average precision for the experimental data set. This integrated sensor and classification systems demonstrates a new approach for automated, on-blade collision detection for wind turbines, with broad utility across structural health monitoring applications.

17 WIND ENERGY↗

Method and apparatus for operating a powertrain system upon detecting a stuck-closed clutch

A powertrain system includes a multi-mode transmission having a plurality of torque machines. A method for controlling the powertrain system includes identifying all presently applied clutches including commanded applied clutches and the stuck-closed clutch upon detecting one of the torque-transfer clutches is in a stuck-closed condition. A closed-loop control system is employed to control operation of the multi-mode transmission accounting for all the presently applied clutches.

42 ENGINEERING↗

A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy

Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into different failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.

60 APPLIED LIFE SCIENCES↗

Ion imaging in a high-gradient magnetic guide

We study a photoionization method to detect and image a narrow beam of cold atoms traveling along a high-gradient two-wire magnetic guide that is continuously on. Ions are accelerated in a compact acceleration region, directed through a drift region several centimeters in length, and detected using a position-sensitive ion detector. The potentials of several electrodes can be varied to adjust the imaging properties. Using ion trajectory simulations as well as experiments, we study the passage of the ions through the detection system, the magnification of the detection system, and the time-of-flight characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airborne Windshear Detection and Warning Systems. Fifth and Final Combined Manufacturers' and Technologists' Conference, part 1

The Fifth (and Final) Combined Manufacturers' and Technologists' Airborne Windshear Review Meeting was hosted jointly by the NASA Langley Research Center (LaRC) and the Federal Aviation Administration (FAA) in Hampton, Virginia, on September 28-30, 1993. The purpose of the meeting was to report on the highly successful windshear experiments conducted by government, academic institutions, and industry; to transfer the results to regulators, manufacturers, and users; and to set initiatives for future aeronautics technology research. The formal sessions covered recent developments in windshear flight testing; windshear modeling, flight management, and ground-based systems; airborne windshear detection systems; certification and regulatory issues; development and applications of sensors for wake vortex detection; and synthetic and enhanced vision systems.

Delnore, Victor E.↗

3013 Inner Can Lid Leak Test System Development

Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiber-Optic System Would Detect Leaking Liquid H2

Proposed instrument based on optical time-domain reflectometry measures both locations and sizes of leaks in tanks and plumbing storing and transferring liquid hydrogen. Conceived for use in detecting leaks of hydrogen from propulsion system of Space Shuttle, concept applicable to detection of flammable and/or poisonous fumes in chemical-processing plants, fuel-distributing equipment, and other terrestrial applications.

Grove, Charles H.↗

Measuring the Performance of Two Stationary Interrogation Systems for Detecting Downstream and Upstream Movement of PIT-Tagged Salmonids

Abstract We tested the performance of two stationary interrogation systems designed for detecting the movement of fish with passive integrated transponder (PIT) tags. These systems allowed us to determine the direction of fish movement with high detection efficiency and high precision in a dynamic stream environment. We describe an indirect method for deriving an estimate for detection efficiency and the associated variance that does not rely on a known number of fish passing the system. By using six antennas arranged in a longitudinal series of three arrays, we attained detection efficiencies for downstream- and upstream-moving fish exceeding 96% during high-flow periods and approached 100% during low-flow periods for the two interrogation systems we tested. Because these systems did not rely on structural components, such as bridges or culverts, they were readily adaptable to remote, natural stream sites. Because of built-in redundancy, these systems were able to perform even with a loss of one or more antennas owing to dislodgement or electrical failure. However, the reduction in redundancy resulted in decreased efficiency and precision and the potential loss of ability to determine the direction of fish movement. What we learned about these systems should be applicable to a wide variety of other antenna configurations and to other types of PIT tags and transceivers.

Connolly, Patrick J.↗

Feasibility of an onboard wake vortex avoidance system

It was determined that an onboard vortex wake detection system using existing, proven instrumentation is technically feasible. This system might be incorporated into existing onboard systems such as a wind shear detection system, and might provide the pilot with the location of a vortex wake, as well as an evasive maneuver so that the landing separations may be reduced. It is suggested that this system might be introduced into our nation's commuter aircraft fleet and major air carrier fleet and permit a reduction of current landing separation standards, thereby reducing takeoff and departure delays.

Bilanin, Alan J.↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Water system virus detection

The performance of a waste water reclamation system is monitored by introducing a non-pathogenic marker virus, bacteriophage F2, into the waste-water prior to treatment and, thereafter, testing the reclaimed water for the presence of the marker virus. A test sample is first concentrated by absorbing any marker virus onto a cellulose acetate filter in the presence of a trivalent cation at low pH and then flushing the filter with a limited quantity of a glycine buffer solution to desorb any marker virus present on the filter. Photo-optical detection of indirect passive immune agglutination by polystyrene beads indicates the performance of the water reclamation system in removing the marker virus. A closed system provides for concentrating any marker virus, initiating and monitoring the passive immune agglutination reaction, and then flushing the system to prepare for another sample.

Fraser, A. S.↗

EDDY CURRENT SYSTEM FOR DETECTION OF CRACKING BENEATH BRAIDING IN CORRUGATED METAL HOSE

In this paper an eddy current system for the detection of partially-through-the-thickness cracks in corrugated metal hose is presented. Design criteria based upon the geometry and conductivity of the part are developed and applied to the fabrication of a prototype inspection system. Experimental data are used to highlight the capabilities of the system and an image processing technique is presented to improve flaw detection capabilities. A case study for detection of cracking damage in a space shuttle radiator retract flex hoses is also presented.

39↗

Eddy Current System for Detection of Cracking Beneath Braiding in Corrugated Metal Hose

In this paper an eddy current system for the detection of partially-through-the-thickness cracks in corrugated metal hose is presented. Design criteria based upon the geometry and conductivity of the part are developed and applied to the fabrication of a prototype inspection system. Experimental data are used to highlight the capabilities of the system and an image processing technique is presented to improve flaw detection capabilities. A case study for detection of cracking damage in a space shuttle radiator retract flex hoses is also presented.

Wincheski, Buzz↗