Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Characterization of Temperature Heterogeneity in Utility-Scale Power Plant Boilers by Spatially Distributed Ultrasonic Measurements

In extreme environments, even hardened insertion sensors fail quickly. For such environments, we have developed an ultrasonic (US) method for measuring the spatial distribution of temperatures in solid materials and, specifically, across containments of extreme processes. By deploying US sensors in multiple locations, spatial heterogeneity in temperatures inside harsh environments may be characterized. In this note, we update our progress on testing the developed approach in an industrial setting and its performance in describing the temperature distribution inside a 500 MW (electrical) coalfired utility boiler of an electrical power generation plant. We use waveguides (WG) structured to contain echogenic features that produce a train of echoes in response to an excitation pulse. The time of flight between echoes encodes the information on the temperature distribution in the corresponding segment of the WG, which we reconstruct using its parametrization. Five waveguides were welded to the boiler’s heat exchange surface (waterwall) and different locations at the same boiler elevation and produced reliable US waveforms 18 months after the installation. For several weeks during the latest trial, we performed US measurements in five locations spanning half of the boiler’s 14-meter width. The measurements were acquired during regular operation, including load cycling to adjust for demand and intermittent contributions of renewable power sources, and during boiler shutdown for emergency maintenance and the subsequent restart. The interpretation of US waveforms by signal processing resulted in an accurate estimation of temperature distribution along the waveguides. We captured daily cyclical variations in demand-following load. Measurements performed in multiple locations revealed unexpected temperature variations across the boiler. We conclude that an array of developed sensors can provide responsive and spatial temperature measurements while maintaining functionality despite prolonged exposure to an extreme environment.

Walton, Kenneth↗

Exploring the Use of FHWA Truck Traffic Volume and Weight Data to Support National Truck Freight Mobility Study

The goal of this exploratory study was to investigate alternative data sources and develop methodologies to estimate trends and adjustment factors that could be applied to calibrate statistics generated from the outdated 2002 VIUS. The main focus of this study was on utilizing the FHWA’s traffic data (i.e., VTRIS and TMAS), along with other supplemental freight data (i.e., FAF and CFS), to examine changes in truck volumes and truck weight distributions over time. Ultimately, this effort seeks to develop certain adjustments/factors that could be used to realign perspective VIUS data. Unfortunately, as pointed out previously in this technical memorandum, there are no readily available data sources that could be used to explicitly validate the estimated results from this study. This study compared the estimated distributions from the 2002 VTRIS to the 2002 VIUS data to establish linkages between the two datasets. With distributions and patterns generated based on VTRIS and TMAS data series for additional years, trend factors were then estimated and applied to “update” VIUS-based information. This study resulted in three key highlights: (1) Updated estimates on truck volume and truck VMT can be utilized to better estimate on energy uses by truck. (2) Vehicle class distribution, percent/share of empty trucks, and average truck payload could be updated by utilizing more current annual data series such as VTRIS and TMAS. (3) Additional information could be estimated (e.g., distance distribution by operational type) by integrating other data sources, such as CFS and FAF, instead of relying on the 2002 VIUS data.

33 ADVANCED PROPULSION SYSTEMS↗

Estimating Air Chemical Emissions from Research Activities Using Stack Measurement Data

Current methods of estimating air emissions from research and development (R&D) activities use a wide range of release fractions or emission factors with bases ranging from empirical to semi-empirical. Although considered conservative, the uncertainties and confidence levels of the existing methods have not been reported. Chemical emissions were estimated from sampling data taken from four research facilities over ten years. The approach was to use a Monte Carlo technique to create distributions of annual emission estimates for target compounds detected in source test samples. Distributions were created for each year and building sampled for compounds with sufficient detection frequency to qualify for the analysis. The results using the Monte Carlo technique without applying a filter to remove negative emission values showed almost all distributions spanning zero, and forty percent of the distributions having a negative mean. This indicates that emissions are so low as to be indistinguishable from building background. Application of a filter to allow only positive values in the distribution provided a more realistic value for emissions and increased the distribution mean by an average of sixteen percent. Release fractions were calculated by dividing the emission estimates by a building chemical inventory quantity. Two variations were used for this quantity: chemical usage, and chemical usage plus one-half standing inventory. Filters were applied so that only release fraction values from zero to one were included in the resulting distributions. Release fractions had a wide range among chemicals and among data sets for different buildings and/or years for a given chemical. Regressions of release fractions to molecular weight and vapor pressure showed weak correlations. Similarly, regressions of mean emissions to chemical usage, chemical inventory, molecular weight and vapor pressure also gave weak correlations. These results highlight the difficulties in estimating emissions from R&D facilities using chemical inventory data.

air chemical sampling, air emissions, research and↗

Chromatic-free spatially resolved optical emission spectroscopy diagnostics for microplasma

A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 {mu}m is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

H i, CO, and Dust in the Perseus Cloud

Comparison analyses between the gas emission data (H I 21 cm line and CO 2.6 mm line) and the Planck/IRAS dust emission data (optical depth at 353 GHz τ{sub 353} and dust temperature T{sub d}) allow us to estimate the amount and distribution of the hydrogen gas more accurately, and our previous studies revealed the existence of a large amount of optically thick H I gas in the solar neighborhood. Referring to this, we discuss the neutral hydrogen gas around the Perseus cloud in the present paper. By using the J-band extinction data, we found that τ{sub 353} increases as a function of the 1.3th power of column number density of the total hydrogen (N{sub H}), and this implies dust evolution in high density regions. This calibrated τ{sub 353}--N{sub H} relationship shows that the amount of the H I gas can be underestimated to be ∼60% if the optically thin H I method is used. Based on this relationship, we calculated the optical depth of the 21 cm line (τ{sub HI}) and found that 〈τ{sub HI}〉∼0.92 around the molecular cloud. The effect of τ{sub HI} is still significant, even if we take into account the dust evolution. We also estimated a spatial distribution of the CO-to-H{sub 2} conversion factor (X{sub CO}), and we found its average value is 〈X{sub CO}〉∼1.0×10{sup 20} cm{sup −2} K{sup −1} km{sup −1} s. Although these results are inconsistent with some previous studies, these discrepancies can be well explained by the difference of the data and analyses methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Species richness and endemism in the native flora of California

California’s vascular flora is the most diverse and threatened in temperate North America. Previous studies of spatial patterns of Californian plant diversity have been limited by traditional metrics, non-uniform geographic units, and distributional data derived from floristic descriptions for only a subset of species. We revisited patterns of sampling intensity, species richness, and relative endemism in California based on equal-area spatial units, the full vascular flora, and specimen-based distributional data. We estimated richness, weighted endemism (inverse range-weighting of species), and corrected weighted endemism (weighted endemism corrected for richness), and performed a randomization test for significantly high endemism. Possible biases in herbarium data do not obscure patterns of high richness and endemism at the spatial resolution studied. High species richness was sometimes associated with significantly high endemism (e.g., Klamath Ranges) but often not. In Stebbins and Major’s (1965) main endemism hotspot, Southwestern California, species richness is high across much of the Peninsular and Transverse ranges but significantly high endemism is mostly localized to the Santa Rosa and San Bernardino mountains. In contrast, species richness is low in the Channel Islands, where endemism is significantly high, as also found for much of the Death Valley region. Measures of taxonomic richness, even with greater weighting of range-restricted taxa, are insufficient for identifying areas of significantly high endemism that warrant conservation attention. Differences between our findings and those in previous studies appear to mostly reflect the source and scale of distributional data, and recent analytical refinements.

59 BASIC BIOLOGICAL SCIENCES↗

A Graph Convolutional Network for Active Distribution System Anomaly Detection Considering Measurement Spatial-Temporal Correlations

The accuracy of distribution system state estimation may be significantly impacted by the existence of bad measure-ments and unexpected topology errors. This paper proposes a data-driven Graph Convolutional Network (GCN) for anomaly detection, including bad measurements and topology change events. Compared to many existing machine learning approaches, the proposed approach embeds both spatial-temporal measure-ment correlations, which allows us to detect and distinguish different anomalies. Numerical results carried out on the IEEE 37-node system demonstrate that the proposed-based method can obtain high accuracy in detecting bad data and topology changes as compared to other approaches, even in the presence of high PV penetrations.

active distribution system↗

Data-driven, Interpretable Photometric Redshifts Trained on Heterogeneous and Unrepresentative Data

We present a new method for inferring photometric redshifts in deep galaxy and quasar surveys, based on a data-driven model of latent spectral energy distributions (SEDs) and a physical model of photometric fluxes as a function of redshift. This conceptually novel approach combines the advantages of both machine learning methods and template fitting methods by building template SEDs directly from the spectroscopic training data. This is made computationally tractable with Gaussian processes operating in flux–redshift space, encoding the physics of redshifts and the projection of galaxy SEDs onto photometric bandpasses. This method alleviates the need to acquire representative training data or to construct detailed galaxy SED models; it requires only that the photometric bandpasses and calibrations be known or have parameterized unknowns. The training data can consist of a combination of spectroscopic and deep many-band photometric data with reliable redshifts, which do not need to entirely spatially overlap with the target survey of interest or even involve the same photometric bands. We showcase the method on the i -magnitude-selected, spectroscopically confirmed galaxies in the COSMOS field. The model is trained on the deepest bands (from SUBARU and HST ) and photometric redshifts are derived using the shallower SDSS optical bands only. We demonstrate that we obtain accurate redshift point estimates and probability distributions despite the training and target sets having very different redshift distributions, noise properties, and even photometric bands. Our model can also be used to predict missing photometric fluxes or to simulate populations of galaxies with realistic fluxes and redshifts, for example.

79 ASTRONOMY AND ASTROPHYSICS↗

Decentralized Microgrid Protection Through Relative Fault Direction Classification: Preprint

Protection in inverter-based resources (IBRs) dominated microgrids generally face significant challenges due to the low fault current and inconsistent fault behaviors from IBRs. Recently, machine learning-based approaches have attracted considerable attention to address these challenges. This paper introduces a novel decentralized protection strategy for microgrids. The proposed method decomposes the protection challenge into several distributed learning tasks, enabling individual relays to autonomously determine the direction of faults using a binary classification framework based on support vector machine (SVM) algorithms. Following the distributed fault direction estimation, classifier outcomes are shared among neighboring relays, facilitating a local decision-making process to ascertain the presence of faults within the neighborhood. Finally, a tripping signal is generated based on the classifier results of each relay to operate the circuit breaker. To test and validate this approach, a 100% renewable microgrid model is simulated in MATLAB/Simulink. In the numerical analysis, the application of SVM classifiers in our approach yields impressive results: an average relay classification accuracy of 98%, and a 96% accuracy in circuit breaker control. These findings highlight the potential of machine-learning-based approaches in enhancing the efficiency and reliability of microgrid protection systems.

decentralized algorithm↗

SU-E-T-422: Fast Analytical Beamlet Optimization for Volumetric Intensity-Modulated Arc Therapy

Purpose: To implement a fast optimization algorithm on CPU/GPU heterogeneous computing platform and to obtain an optimal fluence for a given target dose distribution from the pre-calculated beamlets in an analytical approach. Methods: The 2D target dose distribution was modeled as an n-dimensional vector and estimated by a linear combination of independent basis vectors. The basis set was composed of the pre-calculated beamlet dose distributions at every 6 degrees of gantry angle and the cost function was set as the magnitude square of the vector difference between the target and the estimated dose distribution. The optimal weighting of the basis, which corresponds to the optimal fluence, was obtained analytically by the least square method. Those basis vectors with a positive weighting were selected for entering into the next level of optimization. Totally, 7 levels of optimization were implemented in the study.Ten head-and-neck and ten prostate carcinoma cases were selected for the study and mapped to a round water phantom with a diameter of 20cm. The Matlab computation was performed in a heterogeneous programming environment with Intel i7 CPU and NVIDIA Geforce 840M GPU. Results: In all selected cases, the estimated dose distribution was in a good agreement with the given target dose distribution and their correlation coefficients were found to be in the range of 0.9992 to 0.9997. Their root-mean-square error was monotonically decreasing and converging after 7 cycles of optimization. The computation took only about 10 seconds and the optimal fluence maps at each gantry angle throughout an arc were quickly obtained. Conclusion: An analytical approach is derived for finding the optimal fluence for a given target dose distribution and a fast optimization algorithm implemented on the CPU/GPU heterogeneous computing environment greatly reduces the optimization time.

60 APPLIED LIFE SCIENCES↗

Structural and Stratigraphic Controls on Methane Hydrate occurrence and distribution: Gulf of Mexico, Walker Ridge 313 and Green Canyon 955: Final Report

The goal of this project was to determine structural and stratigraphic controls on hydrate occurrence and distribution in Green Canyon (GC) 955 and Walker Ridge (WR) 313 blocks using seismic and well data. Gas hydrate was discovered in these blocks in coarse- and fine-grained sediments during the 2009 Joint Industrial project (JIP) Leg 11 drilling expedition. Although the immediate interest of the exploration community is exclusively hydrate which is present in coarse–grained sediments, factors that control hydrate and free gas distribution in the two blocks and whether coarse and fine-grained hydrate-bearing units are related in any manner, formed the core of this research. The project spanned from 10/01/2012 to 07/31/2016. In the project, in both the leased blocks, the interval spanning the gas hydrate stability zone (GHSZ) was characterized using a joint analysis of sparse Ocean Bottom Seismic (OBS) and dense, surface–towed multichannel seismic (MCS) data. The project team had the luxury of calibrating their results with two well logs. Advance processing methods such as depth migration and full-waveform inversion (FWI) were used for seismic data analysis. Hydrate quantification was achieved through interpretation of the FWI velocity field using appropriate rock physics models at both blocks. The seismic modeling/inversion methodology (common to both GC955 and WR313 blocks) was as follows. First, the MCS data were depth migrated using a P-wave velocity (VP) model constructed using inversion of reflection arrival times of a few (four in both cases) key horizons carefully picked in the OBS data to farthest possible offsets. Then, the resolution of the traveltime VP model was improved to wavelength scale by inverting OBS gathers up to the highest frequency possible (21.75 Hz for GC955 and 17.5 for WR313) using FWI. Finally, the hydrate saturation (or the volume fraction) was estimated at the well location assuming one of the other hydrate morphology (filling the primary or the secondary porosity) was extrapolated out from the wells using the FWI VP as a guide. General outcomes were as follows. First and foremost, an imaging methodology using sparse seismic data, which is easily replicable at other sites with similar datasets, has been demonstrated. The end product of this methodology at both the leased blocks is quantitative estimates of hydrate distribution. Second, at both locations there is strong evidence that the base of the GHSZ, which does not appear as a clear Bottom Simulating Reflection (BSR), manifests in the VP perturbations created by FWI, suggesting that FWI is sensitive to subtle compositional changes in shallow sediments and establishes it as a valuable tool for investigations of hydrate-bearing basins. Third, through joint interpretation of the depth migrated image and the FWI VP model, how structure and stratigraphy jointly determine hydrate and free gas distribution in both blocks could be clearly visualized. The joint interpretation also suggests that the coarse and fine grained hydrate-bearing sediments at both leased are connected. Site specific results, in addition to general results, are as follows. At GC955 the overlying fine-grained hydrate-bearing unit could have been sourced from the underlying hydrate coarse-grained channel-levee complex through a chimney feature. The channel-levee system at GC955 is compartmentalized by faults, of which only a few may be impermeable. Although compartmentalized, the channel-levee system in the GC955 as a whole might be in communication except selected zones. At WR313 the overlying fine-grained fracture-filled hydrate unit appears to be sourced from below the GHSZ. The reason that only a particular fine-grained unit has hydrate, despite having lower porosity that the bounding units, could be the presence of secondary porosity (such as those formed from clay dewatering under compaction). In conclusion, the project was a pioneering effort in in joint analysis of OBS and MCS datasets for advancing the knowledge about a hydrate and free–gas system dynamics using advanced processing methods such as FWI and depth migration. Results obtained in this project can greatly advance the tools and techniques used for delineating specific hydrate prospects. Results obtained in this project can also be seamlessly incorporated into other DOE funded project on modeling the potential productivity and commercial viability of hydrate from sand-dominated reservoirs. The OBS and MCS data in this project were acquired in 2012 (after the JIP II drilling) by the USGS and therefore the results are a posteriori. Nonetheless, the seismic inversion workflow established through this project can be used to generate various what-if quantification scenarios even in absence of logs and serve as a valuable tool for guiding drilling operations. Results from this project can augment other DOE sponsored projects on determining the commercial viability of methane production from the Gulf of Mexico.

03 NATURAL GAS↗

Exploring the Mass-loss Histories of the Red Supergiants

We report mid- to far-infrared imaging and photometry from 7 to 37 μm with SOFIA/FORCAST and 2 μm adaptive optics imaging with LBTI/LMIRCam of a large sample of red supergiants (RSGs) in four Galactic clusters: RSGC1, RSGC2 = Stephenson 2, RSGC3, and NGC 7419. The RSGs in these clusters cover their expected range in luminosity and initial mass from ≈9 to more than 25 M {sub ⊙}. The population includes examples of very late-type RSGs such as MY Cep, which may be near the end of the RSG stage, high-mass-losing maser sources, yellow hypergiants, and post-RSG candidates. Many of the stars and almost all of the most luminous have spectral energy distributions (SEDs) with extended infrared excess radiation at the longest wavelengths. To best model their SEDs, we use the DUSTY code with a variable radial density distribution function to estimate their mass-loss rates. Our M-dot –luminosity relation for 42 RSGs basically follows the classical de Jager curve, but at luminosities below 10{sup 5} L{sub ⊙}, we find a significant population of RSGs with M-dot below the de Jager relation. At luminosities above 10{sup 5} L {sub ⊙}, there is a rapid transition to higher mass-loss rates that approximates and overlaps the de Jager curve. We recommend that instead of using a linear relation or single curve, the empirical M-dot –luminosity relation is better represented by a broad band. Interestingly, the transition to much higher M-dot at about 10{sup 5} L {sub ⊙} corresponds approximately to an initial mass of 18–20 M {sub ⊙}, which is close to the upper limit for RSGs becoming Type II supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on primordial non-Gaussianity from galaxy-CMB lensing cross correlation

Recent studies have shown that the primordial non-Gaussianity affects the clustering of dark matter halos through a scale-dependent bias, and various constraints on the non-Gaussianity through this scale-dependent bias have been placed. Here, we introduce the cross correlation between the CMB lensing potential and the galaxy angular distribution to effectively extract information about the bias from the galaxy distribution. Then, we estimate the error of the nonlinear parameter, f{sub NL}, for the ongoing CMB experiments and galaxy surveys, such as Planck and Hyper Suprime-Cam. We found that for the constraint on f{sub NL} with Planck and Hyper Suprime-Cam, the wide field galaxy survey is preferable to the deep one, and the expected error on f{sub NL} can be as small as {Delta}f{sub NL{approx}}80 for b{sub 0}=2 and {Delta}f{sub NL{approx}}30 for b{sub 0}=4, where b{sub 0} is the linear bias parameter. It is also found that a future wide field galaxy survey could achieve {Delta}f{sub NL{approx}}5 with cosmic microwave background prior to Planck, if one could observe highly biased objects at higher redshift (z{approx}2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric impact of an {sup 192}Ir brachytherapy source cable length modeled using a grid-based Boltzmann transport equation solver

Purpose: To evaluate the dose distributions of an {sup 192}Ir source (model VS2000) in homogeneous water geometry calculated using a deterministic grid-based Boltzmann transport equation solver (GBBS) in the commercial treatment planning system (TPS) (BRACHYVISION-ACUROS v8.8). Methods: Using percent dose differences (%{Delta}D), the GBBS (BV-ACUROS) was compared to the (1) published TG-43 data, (2) MCNPX Monte Carlo (MC) simulations of the {sup 192}Ir source centered in a 15 cm radius water sphere, and (3) TG-43 output from the TPS using vendor supplied (BV-TG43-vendor) and user extended (BV-TG43-extended) 2D anisotropy functions F(r,{theta}). BV-ACUROS assumes 1 mm of NiTi cable, while the TPS TG-43 algorithm uses data based on a 15 cm cable. MC models of various cable lengths were simulated. Results: The MC simulations resulted in >20% dose deviations along the cable for 1, 2, and 3 mm cable lengths relative to 15 cm. BV-ACUROS comparisons with BV-TG43-vendor and BV-TG43-extended yielded magnitude of differences, consistent with those seen in MC simulations. However, differences >20% extended further ({theta}{<=}10 deg.) when using the vendor supplied anisotropy function F{sub ven}(r,{theta}). These differences were also seen in comparisons of F(r,{theta}) derived from the TPS output. Conclusions: The results suggest that %{Delta}D near the cable region is larger than previously estimated. The spatial distribution of the dose deviation is highly dependent on the reference TG-43 data used to compare to GBBS. The differences observed, while important to realize, should not have an impact on clinical dosimetry in homogeneous water.

61 RADIATION PROTECTION AND DOSIMETRY↗

Estimation of end of life mobile phones generation: The case study of the Czech Republic

Highlights: Black-Right-Pointing-Pointer In this paper, we define lifespan of mobile phones and estimate their average total lifespan. Black-Right-Pointing-Pointer The estimation of lifespan distribution is based on large sample of EoL mobile phones. Black-Right-Pointing-Pointer Total lifespan of Czech mobile phones is surprisingly long, exactly 7.99 years. Black-Right-Pointing-Pointer In the years 2010-20, about 26.3 million pieces of EoL mobile phones will be generated in the Czech Republic. - Abstract: The volume of waste electrical and electronic equipment (WEEE) has been rapidly growing in recent years. In the European Union (EU), legislation promoting the collection and recycling of WEEE has been in force since the year 2003. Yet, both current and recently suggested collection targets for WEEE are completely ineffective when it comes to collection and recycling of small WEEE (s-WEEE), with mobile phones as a typical example. Mobile phones are the most sold EEE and at the same time one of appliances with the lowest collection rate. To improve this situation, it is necessary to assess the amount of generated end of life (EoL) mobile phones as precisely as possible. This paper presents a method of assessment of EoL mobile phones generation based on delay model. Within the scope of this paper, the method has been applied on the Czech Republic data. However, this method can be applied also to other EoL appliances in or outside the Czech Republic. Our results show that the average total lifespan of Czech mobile phones is surprisingly long, exactly 7.99 years. We impute long lifespan particularly to a storage time of EoL mobile phones at households, estimated to be 4.35 years. In the years 1990-2000, only 45 thousands of EoL mobile phones were generated in the Czech Republic, while in the years 2000-2010 the number grew to 6.5 million pieces and it is estimated that in the years 2010-2020 about 26.3 million pieces will be generated. Current European legislation sets targets on collection and recycling of WEEE in general, but no specific collection target for EoL mobile phone exists. In the year 2010 only about 3-6% of Czech EoL mobile phones were collected for recovery and recycling. If we make similar estimation using an estimated average EU value, then within the next 10 years about 1.3 billion of EoL mobile phones would be available for recycling in the EU. This amount contains about 31 tonnes of gold and 325 tonnes of silver. Since Europe is dependent on import of many raw materials, efficient recycling of EoL products could help reduce this dependence. To set a working system of collection, it will be necessary to set new and realistic collection targets.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamics of the reaction C({sup 3}P)+SiH{sub 4}: Experiments and calculations

We conducted the reaction C({sup 3}P)+SiH{sub 4} at a collision energy of 4.0 kcal mol{sup -1} in a crossed molecular-beam apparatus measuring time-of-flight mass spectra and selective photoionization. Product ions with m/z=41-43 are associated with two product channels, H{sub 2}SiCH/HSiCH{sub 2}/SiCH{sub 3}+H and H{sub 2}SiC/HSiCH/SiCH{sub 2}+H{sub 2}. Apart from daughter ions and isotopic variants of reaction products, the species observed at m/z=43 is assigned to product H{sub 2}SiCH/HSiCH{sub 2}/SiCH{sub 3} and that at m/z=42 to product H{sub 2}SiC/HSiCH/SiCH{sub 2}. The signals observed at m/z=41 are due to dissociative ionization of silicon-carbon hydrides of these two types. We report time-of-flight spectra of products at specific laboratory angles and theoretical simulations, from which both kinetic-energy and angular distributions of products in the center-of-mass frame were derived. The release of kinetic energy is weakly dependent on the scattering angle for these two reactions. The channels for loss of H and H{sub 2} release average translational energies of 10.5 and 16.7 kcal mol{sup -1}, respectively. As hydrogen transfer before decomposition is facile, products H{sub 2}SiCH/HSiCH{sub 2}/SiCH{sub 3} and H{sub 2}SiC/HSiCH/SiCH{sub 2} exhibit mildly forward/backward preferred and isotropic angular distributions, respectively. We estimate the branching ratios of these channels for loss of H and H{sub 2} to be roughly 6:4. The measurements of release of kinetic energy and ionization thresholds of products indicate that SiCH{sub 3}({sup 2}A{sup ''}) and SiCH{sub 2}({sup 3}A{sub 2}) are dominant among isomeric products. To explore the reaction mechanism, we computed the potential-energy surfaces for the reaction C({sup 3}P)+SiH{sub 4}. The most likely mechanism is that atom C {sup 3}P inserts into bond Si-H of SiH{sub 4} in the entrance channel, and the reaction complex H{sub 3}SiCH subsequently isomerizes to HSiCH{sub 3} followed by decomposition to SiCH{sub 3}({sup 2}A{sup ''})+H and SiCH{sub 2}({sup 3}A{sub 2})+H{sub 2}. We observed no significant evidence for the reaction C({sup 1}D)+SiH{sub 4}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Monte Carlo Technique to Estimate Emissions from R&D Facilities

The Pacific Northwest National Laboratory (PNNL) operates multidisciplinary laboratory Research and Development (R&D) facilities for the U. S. Department of Energy and sampled air chemical emissions from some of these facilities from 1998 until 2008. Although sampling was not required for environmental compliance, PNNL conducted sampling to provide data to compare estimated release fractions to those used for emissions estimates and to verify that methods used to determine compliance with air regulations and permits conservatively predict actual emissions. Sampling also identifies and quantifies air toxics emitted to compare with compliance limits established by the State. The sampling data provides a unique opportunity to quantify emissions and investigate factors potentially impacting emissions. Previous work using this data set include a paper by Woodruff, Benar, and McCarthy1 who summarized the compliance approach used by PNNL and described sampling and analytical measurements for the first sampling campaigns. Conclusions reported in the paper were that none of the measurements of the target compounds exceeded a State acceptable source impact level (ASIL)2 even using significant overestimation factors, and that an average release fraction calculated from the data provided reasonable validation of the factor used in compliance assessments. Other reports using the data include the following: • A metric was developed by Ballinger, Duchsherer, and Metoyer3 to compare chemical signatures. The analysis found similarities in chemical signatures from three of the buildings but a markedly different signature from the fourth building. • A method was developed and used on the data to rank the chemical compounds that present the greatest risk to a potential downstream receptor and to determine whether the sampling parameters and detection limits provided sufficient resolution to verify compliance at potential receptor locations.4 • The stack data from one of the buildings was analyzed using a statistical technique called Positive Matrix Factorization (PMF) to identify the number and composition of major contributing sources to measured stack concentrations.5 In this analysis, a method is described that uses a Monte Carlo technique to produce a distribution of emission estimates from the measured data. The method is applied to one of the chemicals previously identified as more significant than others using the ranking process.4 Variations on the method are investigated and compared to determine their effects on the emission estimates.

Laboratory, air chemical emissions, volatile organ↗