Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

731 records · Page 41

Quantifying Streambed Grain Size, Uncertainty, and Hydrobiogeochemical Parameters Using Machine Learning Model YOLO

Abstract Streambed grain sizes control river hydro‐biogeochemical (HBGC) processes and functions. However, measuring their quantities, distributions, and uncertainties is challenging due to the diversity and heterogeneity of natural streams. This work presents a photo‐driven, artificial intelligence (AI)‐enabled, and theory‐based workflow for extracting the quantities, distributions, and uncertainties of streambed grain sizes from photos. Specifically, we first trained You Only Look Once, an object detection AI, using 11,977 grain labels from 36 photos collected from nine different stream environments. We demonstrated its accuracy with a coefficient of determination of 0.98, a Nash–Sutcliffe efficiency of 0.98, and a mean absolute relative error of 6.65% in predicting the median grain size of 20 ground‐truth photos representing nine typical stream environments. The AI is then used to extract the grain size distributions and determine their characteristic grain sizes, including the 10th, 50th, 60th, and 84th percentiles, for 1,999 photos taken at 66 sites within a watershed in the Northwest US. The results indicate that the 10th, median, 60th, and 84th percentiles of the grain sizes follow log‐normal distributions, with most likely values of 2.49, 6.62, 7.68, and 10.78 cm, respectively. The average uncertainties associated with these values are 9.70%, 7.33%, 9.27%, and 11.11%, respectively. These data allow for the computation of the quantities, distributions, and uncertainties of streambed HBGC parameters, including Manning's coefficient, Darcy‐Weisbach friction factor, top layer interstitial velocity magnitude, and nitrate uptake velocity. Additionally, major sources of uncertainty in grain sizes and their impact on HBGC parameters are examined.

58 GEOSCIENCES↗

Combustion energy frontier research center (CEFRC) final report (August 1, 2009 – July 31, 2016)

The Combustion Energy Frontier Research Center (CEFRC) was established to tackle the single overarching grand challenge of energy sustainability, energy security and global warming: to develop a “validated, predictive, multi-scale, combustion modeling capability to optimize the design and operation of evolving fuels in advanced engines for transportation applications,” as identified in the DOE report on “Basic Energy Needs for Clean and Efficient Combustion of 21st Century Transportation Fuels”. The challenge is particularly daunting since energy conversion efficiencies and exhaust emissions are governed by coupled chemical and transport processes at multiple length scales ranging from electron excitation to molecular rearrangements to nanoscale particulate formation to turbulent fuel/air mixing. To tackle this challenge, the CEFRC assembled a world-class team of 15 principal investigators, with the objectives to: 1) develop and test theoretical models to predict elementary reaction rates, molecule thermalization rates, chemical bond dissociation energies, and nonequilibrium transport properties using quantum chemistry calculations that account for strong electron correlation and multiple electronic potential energy surfaces; 2) develop automated kinetic mechanism generation, reduction, and error control methods for predicting alternative fuel including biofuel oxidation, fuel droplet decomposition, and NOx and particulate formation; 3) validate and improve the predictions of these models by measuring ignition delay times, species profiles, flame structures, burning limits, turbulence-kinetic coupling, and NOx and soot emissions at high-pressures and near-limit conditions, by using advanced experimental diagnostic techniques including multiple laser techniques, molecular beam sampling and synchrotron photoionization, and by conducting the measurements in high-pressure shock tubes, jet-stirred and flow reactors, flame bombs, counterflow flames, and advanced-design rapid compression ignition instruments; and 4) develop a suite of validated petascale high-fidelity simulation and modeling capabilities to understand and predict chemistry-turbulence-radiation coupling for new fuels in new regimes, including the high pressure, low-temperature combustion in advanced engine and turbine designs, and 5) establish a knowledge highway between researchers and engineers in academia, national laboratories, and industry to facilitate the dissemination and exchange of knowledge on national and international levels, and enrich the talent pool and capabilities of the next generation of combustion scientists and engineers. The technical activities of the CEFRC were conducted through three Disciplinary Working Groups – Chemistry Theory, Experiment and Mechanism, and Reacting Flows, which coordinated the Center’s research on the development of combustion chemistry of Foundation Fuels (C0–C4 hydrocarbons), Alcohols, and Biodiesel through three corresponding Mechanism Thrust Groups. Such a two-dimensional coordinated and tightly interwoven research structure has been proven to be highly effective in assuring the interplay between the developments of the fundamentals of combustion science and the utilization of the various categories of fuels. The Center has accomplished the above goals over the five year period (August 1, 2009 – July 31, 2014) with appropriated funding, followed by two additional no-cost-extension (NCE) years. The research results are documented in 230 journal publications, with six legacy review papers on the study of combustion chemistry using shock tubes, flow reactors, rapid compression machines, and flames, on uncertainty quantification, and on theoretical reaction dynamics and chemical modeling of combustion. A robust outreach program complemented these PI-led research activities, consisting of: 1) a roving post-doc program comprised of a corps of Center-appointed, co- or multi-sponsored post-doctoral fellows with rotating assignments to conduct seed projects initiated by at least two PIs, in residence with these sponsoring PIs, to rapidly pursue new and high-risk, high-payoff interdisciplinary ideas; 2) an annual summer school on combustion heavily attended (~200) by senior graduate students and practicing researchers covering advanced topics on chemical kinetics, fluid mechanics, turbulent combustion, engine combustion, new technologies, etc.; 3) a robust open web-site providing Center and community information as well as the lecture videos and notes of the summer school; and 4) widely distributed biannual newsletters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of lump characteristics on self-shielding corrections of active neutron interrogation on fissile material in waste - 15405

Non-destructive active neutron assay techniques such as active neutron coincidence counting, differential die away analysis or the californium shuffler method rely on the interrogation of fissile nuclear materials by an external neutron source. Whether it is a spontaneous fission or (α,n) neutron source, like {sup 252}Cf or AmLi; or a fusion neutron generator, all of these techniques rely on induced secondary fission events to provide prompt or delayed neutron signals that serve as the basis for the fissile material quantification. The accuracy of these fissile mass measurements is therefore dependent on the neutron interrogation efficiencies determined for calibration reference standards and whether the measured items are comparable to the calibration condition. In such favorable conditions, it is possible to establish a reliable empirical non-linear relationship between apparent (uncorrected) and real or true fissile mass. However, in waste measurements, this is unlikely to be the case; thus a calibration approach that takes account of the neutron self-shielding effect is required. By incorporating the Self-Shielding Factor (SSF) of the calibration reference standards, a linear mass calibration factor [s{sup -1}. {sup 239}Pu{sub eq} g{sup -1}] can be found; this calibration is accurate for waste in which the fissile material is 'infinitely dilute' i.e. the waste exhibits no self-shielding; this is assumed to be representative of dispersed material. The self-shielding correction and its systematic uncertainty are then left to be treated as part of the Total Measurement Uncertainty (TMU) evaluation associated with the assay result. The derivation of the TMU contribution associated with the self-shielding effect in nuclear waste is a complex problem for which a reliable evaluation has to be performed. This is usually based on assuming 'worst case scenarios' for the distribution of material that can arise in a particular waste stream. Such an approach is conservative, but often very penalizing, especially if one considers larger lumps (those containing grams of fissile material); for such lumps, the self-shielding correction becomes very significant, potentially altering the mass of {sup 239}Pu{sub eq} by over an order of magnitude. A worst case 'nuclear safety value' may not be the most appropriate choice for building a consignment best estimate or repository sentencing value for an item. In the present work the authors describe a numerical approach to study the variability of neutron self-shielding factors associated with distributions of a wide range of lump characteristics in terms of size, shape, chemical composition, density and isotopic composition. The described novel calculation tool is capable of accurately predicting the real impact of random distribution of lumps in a waste material, and allowed to show that given reasonable, defensible, assumptions on the composition of the lumps in waste stream, the systematic error component of the DDA TMU can be significantly reduced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automatic anatomy recognition in whole-body PET/CT images

Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process, to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object.

61 RADIATION PROTECTION AND DOSIMETRY↗

Inference of reaction rate parameters based on summary statistics from experiments

Here, we present the results of an application of Bayesian inference and maximum entropy methods for the estimation of the joint probability density for the Arrhenius rate para meters of the rate coefficient of the H 2 /O 2 -mechanism chain branching reaction H + O 2 → OH + O. Available published data is in the form of summary statistics in terms of nominal values and error bars of the rate coefficient of this reaction at a number of temperature values obtained from shock-tube experiments. Our approach relies on generating data, in this case OH concentration profiles, consistent with the given summary statistics, using Approximate Bayesian Computation methods and a Markov Chain Monte Carlo procedure. The approach permits the forward propagation of parametric uncertainty through the computational model in a manner that is consistent with the published statistics. A consensus joint posterior on the parameters is obtained by pooling the posterior parameter densities given each consistent data set. To expedite this process, we construct efficient surrogates for the OH concentration using a combination of Pad'e and polynomial approximants. These surrogate models adequately represent forward model observables and their dependence on input parameters and are computationally efficient to allow their use in the Bayesian inference procedure. We also utilize Gauss-Hermite quadrature with Gaussian proposal probability density functions for moment computation resulting in orders of magnitude speedup in data likelihood evaluation. Despite the strong non-linearity in the model, the consistent data sets all res ult in nearly Gaussian conditional parameter probability density functions. The technique also accounts for nuisance parameters in the form of Arrhenius parameters of other rate coefficients with prescribed uncertainty. The resulting pooled parameter probability density function is propagated through stoichiometric hydrogen-air auto-ignition computations to illustrate the need to account for correlation among the Arrhenius rate parameters of one reaction and across rate parameters of different reactions.

97 MATHEMATICS AND COMPUTING↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial intelligence models, photos, and data associated with the manuscript “Quantifying Streambed Grain Size, Uncertainty, and Hydrobiogeochemical Parameters Using Machine Learning Model YOLO” (v2)

This data package is associated with the manuscript “Quantifying Streambed Grain Size, Uncertainty, and Hydrobiogeochemical Parameters Using Machine Learning Model YOLO” published in Water Resources Research (Chen et al., 2024). This data package includes the training, validation, testing, and prediction data used by the artificial intelligence (AI) model for automated grain size and hydro-biogeochemistry quantification using streambed photos. The grain size data are extracted for each photo using You Look Only Once (YOLO), a pre-trained object detection model. This data package was originally published in October 2023. It was updated August 2025 (v2; new and modified files). File and folder names were not revised to indicate changes. See the change history section in the readme for more details. Please see flmd.csv for a list of all files contained in this data package and descriptions for each. Please see dd.csv for a data dictionary that defines the column headers of .csv files in the data package. This dataset is comprised of one data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; and (4) six subfolders. Subfolders 1 to 4 include the training, validation, testing, and prediction data. Subfolder 5_Summary includes the summary results of different combinations of training, validation, testing, and prediction data. Subfolder 6_SupplementalData includes additional data downloaded from public sources (Kaufman et al., 2023a; Kaufman et al., 2023b; Garefalakis et al., 2023; Mair et al., 2024; https://github.com/river-corridors-sfa/Geospatial_variables). In total, the data package includes 110 folders and 44,283 files. These files include 9,047 .jpg photos, 1 .png photo, 3 .tif photos; 26,639 photo labels and individual grain sizes and probability from AI (.txt); 8,447 grain size distribution data (.dat); and 126 CSV files for results summary, and 14 required metadata files (.xlsx). The summary CSV files contain 68 columns and approximately 2,200 rows that represent photo names, site locations, recording time, GPS coordinates, grains sizes (D10, D50, D60, and D84), number of grains, and additional hydro-biogeochemical data such as water depth, flow velocity, Manning’s coefficient, friction factor, hydraulic conductivity, permeability, streambed interstitial velocity magnitude, mass transfer rate, and nitrate uptake velocity. The photos were obtained from 75 sites in the Yakima River Basin and the Columbia River shorelines, and other associated data from samples and sensors obtained when the photos were taken are publicly available (Fulton et al. 2022; Grieger et al. 2023). All files are .csv, .txt, .dat, .jpg, or .pdf. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗