Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Cone Beam Computed Tomography Number Errors and Consequences for Radiotherapy Planning: An Investigation of Correction Methods

Purpose: The potential of keV cone beam computed tomography (CBCT) for guiding adaptive replanning is well-known. There are impediments to this, one being CBCT number accuracy. The purpose of this study was to investigate CBCT number correction methods and the affect of residual inaccuracies on dose deposition. Four different correction strategies were applied to the same patient data to compare performance and the sophistication of correction-method needed for acceptable dose errors. Methods and Materials: Planning CT and CBCT reconstructions were used for 12 patients (6 brain, 3 prostate, and 3 bladder cancer patients). All patients were treated using Elekta linear accelerators and XVI imaging systems. Two of the CBCT number correction methods investigated were based on an algorithm previously proposed by the authors but only previously applied to phantoms. Two further methods, based on an approach previously suggested in the research literature, were also examined. Dose calculations were performed using scans of a 'worst' subset of patients using the Pinnacle{sup 3} version 9.0 treatment planning system and the patients' clinical plans. Results: All mean errors in CBCT number were <50 HU, and all correction methods performed well or adequately in dose calculations. The worst single dose discrepancy identified for any of the examined methods or patients was 3.0%. Mean errors in the doses to treatment volumes or organs at risk were negatively correlated with the mean error in CT number. That is, a mean CT number that was too large, averaged over the entire CBCT volume, implied an underdosing in a volume-of-interest and vice versa. Conclusions: Results suggest that (1) the correction of CBCT numbers to within a mean error of 50 HU in the scan volume provides acceptable discrepancies in dose (<3%) and (2) this is achievable with even quite unsophisticated correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined selection of the dynamic model and modeling error in nonlinear aeroelastic systems using Bayesian Inference

Here, we report a Bayesian framework for concurrent selection of physics-based models and (modeling) error models. We investigate the use of colored noise to capture the mismatch between the predictions of calibrated models and observational data that cannot be explained by measurement error alone within the context of Bayesian estimation for stochastic ordinary differential equations. Proposed models are characterized by the average data-fit, a measure of how well a model fits the measurements, and the model complexity measured using the Kullback–Leibler divergence. The use of a more complex error models increases the average data-fit but also increases the complexity of the combined model, possibly over-fitting the data. Bayesian model selection is used to find the optimal physical model as well as the optimal error model. The optimal model is defined using the evidence, where the average data-fit is balanced by the complexity of the model. The effect of colored noise process is illustrated using a nonlinear aeroelastic oscillator representing a rigid NACA0012 airfoil undergoing limit cycle oscillations due to complex fluid–structure interactions. Several quasi-steady and unsteady aerodynamic models are proposed with colored noise or white noise for the model error. The use of colored noise improves the predictive capabilities of simpler models.

42 ENGINEERING↗

Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantifying local and global mass balance errors in physics-informed neural networks

Physics-informed neural networks (PINN) have recently become attractive for solving partial differential equations (PDEs) that describe physics laws. By including PDE-based loss functions, physics laws such as mass balance are enforced softly in PINN. This paper investigates how mass balance constraints are satisfied when PINN is used to solve the resulting PDEs. We investigate PINN’s ability to solve the 1D saturated groundwater flow equations (diffusion equations) for homogeneous and heterogeneous media and evaluate the local and global mass balance errors. We compare the obtained PINN’s solution and associated mass balance errors against a two-point finite volume numerical method and the corresponding analytical solution. We also evaluate the accuracy of PINN in solving the 1D saturated groundwater flow equation with and without incorporating hydraulic heads as training data. We demonstrate that PINN’s local and global mass balance errors are significant compared to the finite volume approach. Tuning the PINN’s hyperparameters, such as the number of collocation points, training data, hidden layers, nodes, epochs, and learning rate, did not improve the solution accuracy or the mass balance errors compared to the finite volume solution. Mass balance errors could considerably challenge the utility of PINN in applications where ensuring compliance with physical and mathematical properties is crucial.

54 ENVIRONMENTAL SCIENCES↗

An error-controlled fast multipole method

We present a two-stage error estimation scheme for the fast multipole method (FMM). This scheme can be applied to any particle system. It incorporates homogeneous as well as inhomogeneous distributions. The FMM error as a consequence of the finite representation of the multipole expansions and the operator error is correlated with an absolute or relative user-requested energy threshold. Such a reliable error control is the basis for making reliable simulations in computational physics. Our FMM program on the basis of the two-stage error estimation scheme is available on request.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrected Article: 'An error-controlled fast multipole method' [J. Chem. Phys. 131, 244102 (2009)]

We present a two-stage error estimation scheme for the fast multipole method (FMM). This scheme can be applied to any particle system. It incorporates homogeneous as well as inhomogeneous distributions. The FMM error as a consequence of the finite representation of the multipole expansions and the operator error is correlated with an absolute or relative user-requested energy threshold. Such a reliable error control is the basis for making reliable simulations in computational physics. Our FMM program on the basis of the two-stage error estimation scheme is available on request.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise method of compensating radiation-induced errors in a hot-cathode-ionization gauge with correcting electrode

To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method was approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Notes on power of normality tests of error terms in regression models

Normality is one of the basic assumptions in applying statistical procedures. For example in linear regression most of the inferential procedures are based on the assumption of normality, i.e. the disturbance vector is assumed to be normally distributed. Failure to assess non-normality of the error terms may lead to incorrect results of usual statistical inference techniques such as t-test or F-test. Thus, error terms should be normally distributed in order to allow us to make exact inferences. As a consequence, normally distributed stochastic errors are necessary in order to make a not misleading inferences which explains a necessity and importance of robust tests of normality. Therefore, the aim of this contribution is to discuss normality testing of error terms in regression models. In this contribution, we introduce the general RT class of robust tests for normality, and present and discuss the trade-off between power and robustness of selected classical and robust normality tests of error terms in regression models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer

This paper presents a method to reduce the vapor cell temperature error of the spin-exchange-relaxation-free (SERF) magnetometer. The fluctuation of cell temperature can induce variations of the optical rotation angle, resulting in a scale factor error of the SERF magnetometer. In order to suppress this error, we employ the variation of the probe beam absorption to offset the variation of the optical rotation angle. The theoretical discussion of our method indicates that the scale factor error introduced by the fluctuation of the cell temperature could be suppressed by setting the optical depth close to one. In our experiment, we adjust the probe frequency to obtain various optical depths and then measure the variation of scale factor with respect to the corresponding cell temperature changes. Our experimental results show a good agreement with our theoretical analysis. Under our experimental condition, the error has been reduced significantly compared with those when the probe wavelength is adjusted to maximize the probe signal. The cost of this method is the reduction of the scale factor of the magnetometer. However, according to our analysis, it only has minor effect on the sensitivity under proper operating parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of initial phase on error in electron energy obtained using paraxial approximation for a focused laser pulse in vacuum

We have investigated the effect of initial phase on error in electron energy obtained using paraxial approximation to study electron acceleration by a focused laser pulse in vacuum using a three dimensional test-particle simulation code. The error is obtained by comparing the energy of the electron for paraxial approximation and seventh-order correction description of the fields of Gaussian laser. The paraxial approximation predicts wrong laser divergence and wrong electron escape time from the pulse which leads to prediction of higher energy. The error shows strong phase dependence for the electrons lying along the axis of the laser for linearly polarized laser pulse. The relative error may be significant for some specific values of initial phase even at moderate values of laser spot sizes. The error does not show initial phase dependence for a circularly laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical and systematic errors in the measurement of weak-lensing Minkowski functionals: Application to the Canada-France-Hawaii Lensing Survey

The measurement of cosmic shear using weak gravitational lensing is a challenging task that involves a number of complicated procedures. We study in detail the systematic errors in the measurement of weak-lensing Minkowski Functionals (MFs). Specifically, we focus on systematics associated with galaxy shape measurements, photometric redshift errors, and shear calibration correction. We first generate mock weak-lensing catalogs that directly incorporate the actual observational characteristics of the Canada-France-Hawaii Lensing Survey (CFHTLenS). We then perform a Fisher analysis using the large set of mock catalogs for various cosmological models. We find that the statistical error associated with the observational effects degrades the cosmological parameter constraints by a factor of a few. The Subaru Hyper Suprime-Cam (HSC) survey with a sky coverage of ∼1400 deg{sup 2} will constrain the dark energy equation of the state parameter with an error of Δw {sub 0} ∼ 0.25 by the lensing MFs alone, but biases induced by the systematics can be comparable to the 1σ error. We conclude that the lensing MFs are powerful statistics beyond the two-point statistics only if well-calibrated measurement of both the redshifts and the shapes of source galaxies is performed. Finally, we analyze the CFHTLenS data to explore the ability of the MFs to break degeneracies between a few cosmological parameters. Using a combined analysis of the MFs and the shear correlation function, we derive the matter density Ω{sub m0}=0.256±{sub 0.046}{sup 0.054}.

79 ASTRONOMY AND ASTROPHYSICS↗

DETERMINING THE ABSOLUTE ASTROMETRIC ERROR IN CHANDRA SOURCE CATALOG POSITIONS

Although relative errors can readily be calculated, the absolute astrometric accuracy of the source positions in the Chandra Source Catalog (CSC), version 1.0, is a priori unknown. However, the cross-match with stellar objects from the Sloan Digital Sky Survey offers the opportunity to compare the apparent separations of the cross-matched pairs with the formally calculated errors. The analysis of these data allowed us to derive a value of 0.''16 for the residual absolute astrometric error in CSC positions. This error will be added to the published position errors in the CSC from now on, starting with CSC, version 1.1.

79 ASTRONOMY AND ASTROPHYSICS↗

Taylor approximation variance reduction for approximation errors in PDE-constrained Bayesian inverse problems

In numerous applications, surrogate models are used as a replacement for accurate parameter-to-observable mappings when solving large-scale inverse problems governed by partial differential equations (PDEs). The surrogate model may be a computationally cheaper alternative to the accurate parameter-to-observable mappings and/or may ignore additional unknowns or sources of uncertainty. The Bayesian approximation error (BAE) approach provides a means to account for the induced uncertainties and approximation errors, i.e. the errors between the accurate parameter-to-observable mapping and the surrogate. The statistics of these errors are, however, in general unknown a priori, and are thus calculated using Monte Carlo sampling. Although the sampling is typically carried out offline, i.e. before considering the data, the process can still represent a computational bottleneck. In this work, we develop a scalable computational approach for reducing the costs associated with the sampling stage of the BAE approach. Specifically, we consider the Taylor expansion of the accurate and surrogate forward models with respect to the uncertain parameter fields either as a control variate for variance reduction or as a means to directly and efficiently approximate the mean and covariance of the approximation errors. We propose efficient methods for evaluating the expressions for the mean and covariance of the Taylor approximations based on linear(-ized) PDE solves. Furthermore, the proposed approach is independent of the dimension of the uncertain parameter, depending instead on the intrinsic dimension of the data, ensuring scalability to high-dimensional problems. The potential benefits of the proposed approach are demonstrated for two high-dimensional inverse problems governed by PDE examples, namely for the estimation of a distributed Robin boundary coefficient in a linear diffusion problem, and for a coefficient estimation problem governed by a nonlinear diffusion problem.

Bayesian approximation error↗

Estimation and Control of Modeling Error: A General Approach to Multiscale Modeling

This chapter describes a class of computational methods designed to handle multiscale modeling of large atomistic or molecular systems. The key to this approach is the estimation of relative modeling error in which errors in quantities of interest produced by averaging or homogenization are computed using a posteriori error estimates. The error is judged to be the relative error between the fine-scale base model and any number of surrogates produced by homogenization. Features of modeling the atomistic to continuum interface are also addressed. Specific applications of the methodology are described that involve analyzing polymer etch barriers that are used in nano-manufacturing of semi-conductors. The basic adaptive modeling strategy employs goal-oriented adaptation in which fine-scale information is systematically added to hybrid molecular-continuum models until the appropriate level of accuracy in certain quantities of interest is achieved.

97 MATHEMATICS AND COMPUTING↗

Estimating the parameters of nonspinning binary black holes using ground-based gravitational-wave detectors: Statistical errors

We assess the statistical errors in estimating the parameters of nonspinning black hole binaries using ground-based gravitational-wave detectors. While past assessments were based on partial information provided by only the inspiral and/or ring-down pieces of the coalescence signal, the recent progress in analytical and numerical relativity enables us to make more accurate projections using complete inspiral-merger-ring-down waveforms. We employ the Fisher information-matrix formalism to estimate how accurately the source parameters will be measurable using a single interferometric detector as well as a network of interferometers. Those estimates are further vetted by full-fledged Monte Carlo simulations. We find that the parameter accuracies of the complete waveform are, in general, significantly better than those of just the inspiral waveform in the case of binaries with total mass M > or approx. 20M{sub {center_dot}}. In particular, for the case of the Advanced LIGO detector, parameter estimation is the most accurate in the M=100-200M{sub {center_dot}} range. For an M=100M{sub {center_dot}} system, the errors in measuring the total mass and the symmetric mass-ratio are reduced by an order of magnitude or more compared to inspiral waveforms. Furthermore, for binaries located at a fixed luminosity distance d{sub L}, and observed with the Advanced LIGO-Advanced Virgo network, the sky-position error is expected to vary widely across the sky: For M=100M{sub {center_dot}} systems at d{sub L}=1 Gpc, this variation ranges mostly from about a hundredth of a square degree to about a square degree, with an average value of nearly a tenth of a square degree. This is more than 40 times better than the average sky-position accuracy of inspiral waveforms at this mass range. For the mass parameters as well as the sky position, this improvement in accuracy is due partly to the increased signal-to-noise ratio and partly to the information about these parameters harnessed through the post-inspiral phases of the waveform. The error in estimating d{sub L} is dominated by the error in measuring the wave's polarization and is roughly 43% for low-mass (M{approx}20M{sub {center_dot}}) binaries and about 23% for high-mass (M{approx}100M{sub {center_dot}}) binaries located at d{sub L}=1 Gpc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ancilla-Free Quantum Error Correction Codes for Quantum Metrology

Quantum error correction has recently emerged as a tool to enhance quantum sensing under Markovian noise. It works by correcting errors in a sensor while letting a signal imprint on the logical state. This approach typically requires a specialized error-correcting code, as most existing codes correct away both the dominant errors and the signal. To date, however, few such specialized codes are known, among which most require noiseless, controllable ancillas. We show here that such ancillas are not needed when the signal Hamiltonian and the error operators commute, a common limiting type of decoherence in quantum sensors. We give a semidefinite program for finding optimal ancilla-free sensing codes in general, as well as closed-form codes for two common sensing scenarios: qubits undergoing dephasing, and a lossy bosonic mode. Lastly, we analyze the sensitivity enhancement offered by the qubit code under arbitrary spatial noise correlations, beyond the ideal limit of orthogonal signal and noise operators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Destructive Error Interference in Product-Formula Lattice Simulation

Quantum computers can efficiently simulate the dynamics of quantum systems. Here, we study the cost of digitally simulating the dynamics of several physically relevant systems using the first-order product-formula algorithm. We show that the errors from different Trotterization steps in the algorithm can interfere destructively, yielding a much smaller error than previously estimated. In particular, we prove that the total error in simulating a nearest-neighbor interacting system of n sites for time t using the first-order product formula with r time slices is O ( n t / r + n t 3 / r 2 ) when n t 2 / r is less than a small constant. Given an error tolerance ϵ , the error bound yields an estimate of max { O ( n 2 t / ϵ ) , O ( n 2 t 3 / 2 / ϵ 1 / 2 ) } for the total gate count of the simulation. The estimate is tighter than previous bounds and matches the empirical performance observed in Childs et al. [ Proc. Natl. Acad. Sci. U.S.A. 115 , 9456 (2018) ]. We also provide numerical evidence for potential improvements and conjecture an even tighter estimate for the gate count.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Error-Detectable Bosonic Entangling Gates with a Noisy Ancilla

Bosonic quantum error correction has proven to be a successful approach for extending the coherence of quantum memories, but to execute deep quantum circuits, high-fidelity gates between encoded qubits are needed. To that end, we present a family of error-detectable two-qubit gates for a variety of bosonic encodings. From a new geometric framework based on a “Bloch sphere” of bosonic operators, we construct ZZ L ⁡(θ) and exponential-swap(θ) gates for the binomial, four-legged cat, dual-rail, and several other bosonic codes. The gate Hamiltonian is simple to engineer, requiring only a programmable beam splitter between two bosonic qubits and an ancilla dispersively coupled to one qubit. This Hamiltonian can be realized in circuit QED hardware with ancilla transmons and microwave cavities. The proposed theoretical framework was developed for circuit QED but is generalizable to any platform that can effectively generate this Hamiltonian. Crucially, one can also detect first-order errors in the ancilla and the bosonic qubits during the gates. We show that this allows one to reach error-detected gate fidelities at the 0.01% level with today’s hardware, limited only by second-order hardware errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗