Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Object-Based Evaluation of Tropical Precipitation Systems in DYAMOND Simulations over the Maritime Continent

The present study uses an object-based evaluation metric to examine the precipitation bias over the Maritime Continent in the global cloud-resolving models. We specifically focus on the difference between the models that directly resolve convection and those using convection parameterization. The 40-day hindcast experiments of the DYnamics of the Atmospheric general circulation Modeled On Non-hydrostatic Domain (DYAMOND) intercomparison project are evaluated against the high-resolution satellite rainfall products. The hindcast of the Central Weather Bureau Global Forecast System (CWBGFS) under the DYAMOND protocol is also included. The results indicate that most models simulate insufficient numbers of large precipitation system [object-based precipitation system (OPS), > 370 km in scale], indicating weaker convection organization. The observation indicates that the maximum precipitation within the OPS intensifies with increasing object size. All of the models capture this positive relationship, but most of them overestimate the sensitivity. Most of the models overestimate both the frequency and intensity of small OPS (< 160 km), except for the models with convection parameterization [i.e., CWBGFS, European Centre for Medium-Range Weather Forecasts Integrated Forecasting System (IFS)-9 km]. Although most of the models can reproduce the observed peak time of diurnal precipitation over the land area in the Maritime Continent, the simulated fractional contribution of different sizes of OPS to the total precipitation varies from model to model, and their peak times do not follow the observed ones with delayed peak times as the size of OPS increases from small, mid-size, to large categories. Most of the models reasonably capture the mean diurnal cycle peak time, but only the models with convection parameterization and Model for Prediction Across Scales (MPAS) can represent the diurnal evolution of fractional contribution from different OPSs. The implications of the current results to the upscale processes of the tropical convection systems in the global models are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Costs to Automate Demand Response - Taxonomy and Results from Field Studies and Programs

During the past decade, the technology to automate demand response (DR) in buildings and industrial facilities has advanced significantly. Automation allows rapid, repeatable, reliable operation. This study focuses on costs for DR automation in commercial buildings with some discussion on residential buildings and industrial facilities. DR automation technology relies on numerous components, including communication systems, hardware and software gateways, standards-based messaging protocols, controls and integration platforms, and measurement and telemetry systems. This report compares cost data from several DR automation programs and pilot projects, evaluates trends in the cost per unit of DR and kilowatts (kW) available from automated systems, and applies a standard naming convention and classification or taxonomy for system elements. Median costs for the 56 installed automated DR systems studied here are about $200/kW. The deviation around this median is large with costs in some cases being an order of magnitude great or less than the median. This wide range is a result of variations in system age, size of load reduction, sophistication, and type of equipment included in cost analysis. The costs to automate fast DR systems for ancillary services are not fully analyzed in this report because additional research is needed to determine the total cost to install, operate, and maintain these systems. However, recent research suggests that they could be developed at costs similar to those of existing hot-summer DR automation systems. This report considers installation and configuration costs and does include the costs of owning and operating DR automation systems. Future analysis of the latter costs should include the costs to the building or facility manager costs as well as utility or third party program manager cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Y-12 National Security Complex Biological Monitoring and Abatement Program—2024 Calendar Year Report

This report provides the results of the CY 2024 sampling of East Fork Poplar Creek (EFPC) as part of the Y-12 National Security Complex (Y-12) Biological Monitoring and Abatement Program (BMAP). The results are presented in the context of historical trends. The Y-12 BMAP was developed in 1985 to demonstrate that the effluent limits established for Y-12 protected the classified uses of the receiving stream, particularly the growth and propagation of aquatic life (Loar et al. 1989). Over the years, the BMAP has become an important and valuable long-term measure of stream conditions resulting from actions and activities at the Y-12 Complex. The BMAP currently consists of three tasks: (1) bioaccumulation monitoring, (2) benthic macroinvertebrate community monitoring, and (3) fish community monitoring. The benthic macroinvertebrate community monitoring task includes studies to evaluate the receiving stream’s biological integrity annually in comparison with Tennessee Water Quality Criteria following Tennessee Department of Environment and Conservation (TDEC) protocols. In addition to presenting the EFPC biological monitoring results, this report includes results from Comprehensive Environmental Response, Compensation, and Liability Act–funded BMAP programs in Bear Creek and McCoy Branch (presented in Appendixes A and B, respectively), as required in the Y-12 National Pollutant Discharge Elimination System (NPDES) permit. Additional biological testing at the Y-12 Complex includes toxicity testing of select storm drains as required in the NPDES permit. Although toxicity testing is not formally part of the BMAP, toxicity testing results from 2024 are provided in Appendix C.

54 ENVIRONMENTAL SCIENCES↗

Online and Offline Analytical Techniques to Quantify Chloride Salts

This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.

Polke, Amber↗

SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and investigate other cross-platform treatment delivery options.

60 APPLIED LIFE SCIENCES↗

MO-G-BRF-02: Enhancement of Texture-Based Metastasis Prediction Models Via the Optimization of PET/MRI Acquisition Protocols

Purpose: We have previously identified a prediction model of lung metastases at diagnosis of soft-tissue sarcomas (STS) that is composed of two textural features extracted from FDG-PET and T1-weighted (T1w) MRI scans. The goal of this study is to evaluate whether the optimization in FDGPET and MRI acquisition parameters would enhance the prediction performance of texture-based models. Methods: Ten FDG-PET and T1w- MRI digitized tumor models were generated from imaging data of STS patients who underwent pre-treatment clinical scans between 2005 and 2011. Five of ten patients eventually developed lung metastases. Numerically simulated MR images were produced using echo times (TE) of 2 and 4 times the nominal clinical parameter (TEc), and repetition times (TR) of 0.5, 0.67, 1.5 and 2 times the nominal clinical parameter (TRc) found in the DICOM headers (TEc range: 9–13 ms, TRc range: 410-667 ms). PET 2D images were simulated using Monte-Carlo and were reconstructed using an ordered-subsets expectation maximization (OSEM) algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. For all possible combinations of PET and MRI acquisition parameters, the prediction model was constructed using logistic regression with new coefficients, and its associated prediction performance for lung metastases was evaluated using the area under the ROC curve (AUC). Results: The prediction performance over all simulations yielded AUCs ranging from 0.7 to 1. Notably, TR values below or equal to TRc and higher PET post-reconstruction filter widths yielded higher prediction performance. The best results were obtained with a combination of 4*TEc, TRc, 30 OSEM iterations and 2mm filter width. Conclusion: This work indicates that texture-based metastasis prediction models could be improved using optimized choices of FDG-PET and MRI acquisition protocols. This principle could be generalized to other texture-based models.

60 APPLIED LIFE SCIENCES↗

Synthesis and Characterization of Mixed-Conducting Corrosion Resistant Oxide Supports

An extensive search and evaluation of electrochemically stable catalyst supports (including metal oxides like RuO2-SiO2, RuO2-TiO2, and ITO was perfomed during the 4 years of the project. The suports were also catalyzed by deposition of Pt and tested for its performance and electrochemical stability in RDE and fuel cell experiments. For testing the electrochemical stability and fuel cell performance of the catalysts and supports, we have employed the protocols in use at the Department of Energy and Nissan Technological Center North America (NTCNA). The use of such procedures allows a precise and reproducible estimation of the performance and stability of the materials and permits comparisons among laboratories and DOE funded projects. RuO2-SiO2 catalyst supports showed no loss in surface area during start-stop stability tests that were performed by cycling the electrode potential between 0 V to 1.8 V for 1000 cycles. Catalyzed support (40% Pt/RuO2-SiO2; 1:1 mole ratio) were tested in a PEFC, resulting in a current density of 750 mA/cm2 at 0.6 Volts, and a maximum power density of 570 mW/cm2. Measurements were conducted at 80 ºC with 75% relative humidity of the inlet gases (H2/O2); Pt loadings were 0.4 mg/cm2 at the cathode and 0.2 mg/cm2 at the anode. Start-stop stability tests for support and catalyzed support performed in RDE and PEFC set-ups have confirmed RuO2-TiO2 support stability. The beginning of life performance was exactly equal to end of life performance (in an MEA that has been subjected to severe start-stop cycling for 10,000 start/stop cycles between 1 V to 1.5 V). This result was in sharp contrast to baseline Pt/C catalyst that showed significant performance deterioration after accelerated stability tests. The Pt/TRO showed minimal loss in performance upon exposure to start-stop cycles. The loss in cell voltage at 1 A/cm2 at 100% RH was almost 700 mV for Pt/C whereas it was only ca. 15 mV for Pt/TRO. 40% RH data (of inlet gases) revealed a similar trend in terms of stability – exceptional stability for Pt/TRO as opposed to very poor stability for Pt/HSAC. These observations were attributed to the much higher stability of the TRO support compared to Carbon. The carbon dioxide concentration in the cathode exit stream during the accelerated degradation test with Pt/TRO (start-stop protocol) was extremely low (between 3 to 10 ppm of CO2). In contrast, the CO2 emission levels from a conventional Pt/C catalyst were found to be approx. 200 ppm. This observation was a clear indicator that the main source of carbon being oxidized to carbon dioxide in an MEA was the carbon catalyst support, and not the gas diffusion layer or the graphite flow fields. Indium tin oxide (ITO) was also evaluated as a catalyst support for PEFCs. Pt/ITO was very stable under start-up/shutdown accelerated degradation protocol (RDE tests in perchloric acid). The ECSA change was less than 4% over 10,000 cycles. The load cycling accelerated protocol (from 0.6 to 0.95 V vs. RHE) resulted in a loss of approximately 34% of the initial ECSA after 10,000 cycles. However, fuel cell testing resulted in a very low performing catalyst. XPS spectroscopy was employed to investigate the changes in the catalysts occuring during fuel cell operation. It was observed a shift of In 3d5/2 and In 3d3/2 peaks towards higher binding energies. This can be explained by the formation of hydroxides or oxy-hydroxides in the surface of the catalyst. O1s spectrum for Pt/ITO catalyst after being operated in the fuel cell, also confirmed the formation of significant amounts of surface hydroxides (12 to 16%). The presence of surface hydroxides in the catalyst increased the electrode resistivity affecting fuel cell performance. NTCNA performed a detailed analysis of transport phenomena (reactants and products to/from the Pt active sites) in both commercial catalyst and Pt/RTO (in order to have a better understanding at the basic level). The proton resistance (Rionomer) in Pt/C and Pt/RTO cathode catalyst layers were 150 and 12 mΩ-cm2, respectively. Pt/RTO catalyst layer has about an order or magnitude lower proton transfer resistance than Pt/C catalyst layer. Since the ionomer/support ratio that was used in formulating the ink for both catalysts was the same (0.9), it is expected that the volumetric coverage of ionomer of both catalysts will be significantly different due to the disparity in the surface areas (Pt/C had ~ 800 m2/g, while Pt/RTO had ~ 50 m2/g). The differences in the ionomer volumetric coverage and the ionomer film thickness may explain the significantly higher proton conductivity in the Pt/RTO catalyst layer when compared to Pt/HSAC. It is therefore very important to optimize the ionomer loadings when synthesizing new catalyst supports (and never rely on values for carbon-based commercial catalysts). Finally, NTCNA has elaborated a cost model for non-carbon support materials considering their durability benefits. Material costs for production of Pt/ RuO2-TiO2 electrodes were compared to Pt/C. RuO2-TiO2 support was more expensive than carbon but the total material cost was still dominated by platinum cost. Though ruthenium is considered a precious metal, its cost is far less than platinum. It should also be noted that ruthenium only makes up 38% of the mass of the support, while the rest is inexpensive TiO2. After considering the durability advantages of Pt/RTO, cost model showed that even with almost double the Pt loading (0.35 vs 0.18 mgPt/cm2), Pt/RTO ($22.7/kWnet) is only slightly more expensive than Pt/C ($21.9/kWnet).

08 HYDROGEN↗

SU-E-J-152: Evaluation of TrueBeam OBI V. 1.5 CBCT Performance in An Adaptive RT Environment

Purpose: To evaluate the image quality and imaging dose of the Varian TrueBeam OBIv.1.5 CBCT system in a clinical adaptive radiation therapy environment, simulated by changing phantom thickness. Methods: Various OBI CBCT protocols(Head, Pelvis, Thorax, Spotlight) were used to acquire images of Catphan504 phantom(nominal phantom thickness and 10 cm additional phantom thickness). The images were analyzed for low contrast detectability(CNR), uniformity(UI), and HU sensitivity. These results were compared to the same image sets for planning CT(pCT)(GE LightSpeed 16- slice). Imaging dose measurements were performed with Gafchromic XRQA2 film for various OBI protocols (Pelvis, Thorax, Spotlight) in a pelvic-sized phantom(nominal thickness and 4cm additional thickness). Dose measurements were acquired in the interior and at the surface of the phantom. Results: The nominal CNR[additional thickness CNR] for OBI was—Pelvis:1.45[0.81],Thorax:0.86[0.48], Spotlight:0.67[0.39],Head:0.28 [0.10]. The nominal CNR[additional thickness CNR] for pCT was— Pelvis:0.87[0.41],Head:0.60[0.22]. The nominal UI[additional thickness UI] for OBI was—Pelvis:11.5[24.1],Thorax:17.0[20.6], Spotlight:23.2[23.2], Head:15.6[59.9]. The nominal UI[additional thickness UI] for pCT was— Pelvis:9.2[8.6],Head:2.1[2.9]. The HU difference(averaged over all material inserts) between nominal and additional thickness scans for OBI: 8.26HU(Pelvis), 33.39HU(Thorax), 178.98HU(Head), 108.20HU (Spotlight); for pCT: 16.00HU(Pelvis), 19.85HU(Head). Uncertainties in electron density were calculated based on HU values with varying phantom thickness. Average electron-density deviations (ρ(water)=1)for GE-Pelvis, GE-Head, OBI-Pelvis, OBI-Thorax, OBI-Spotlight, and OBI-Head were: 0.0182, 0.0180, 0.0058, 0.0478, 0.2750, and 0.3115, respectively.The average phantom interior dose was(OBI-nominal):2.35cGy(Pelvis), 0.60cGy(Thorax), 1.87cGy(Spotlight); OBI-increased thickness: 1.77cGy(Pelvis), 0.43cGy(Thorax), 1.53cGy (Spotlight). Average surface dose(OBI-nominal): 2.29cGy(Pelvis), 0.56cGy(Thorax), 1.79cGy (Spotlight); OBI-increased thickness: 1.94cGy(Pelvis), 0.48cGy(Thorax), 1.47cGy (Spotlight). Conclusion: The OBI-Pelvis protocol offered comparable CNR and HU constancy to pCT for each geometry; other protocols, particularly Spotlight and Head, exhibited lower HU constancy and CNR. The uniformity of pCT was superior to OBI for all protocols. CNR and UI were degraded for both systems/scan types with increased thickness. The OBI interior dose decreased by approximately 30% with additional thickness. This work was funded, in part, under a grant with the Pennsylvania Department of Health. The Department of Health specifically declaims responsibility for any analyses, interpretations, or conclusions.

60 APPLIED LIFE SCIENCES↗

Development of a Research Reactor Protocol for Neutron Multiplication Measurements

Establishing a protocol for measurements on research reactors is the next step in advanced subcritical neutron multiplication inference measurements. Such measurements can help identify deficiencies and quantify uncertainties in nuclear data and validate predictive Monte Carlo radiation transport simulation capabilities related to subcritical neutron multiplication inference techniques. This work expands on previous benchmark-quality efforts performed at the National Criticality Experiments Research Center (NCERC) located in Nevada, including subcritical experiments with a 4.5-kg {alpha}-phase plutonium sphere surrounded by copper, tungsten and nickel. Evaluations of the nickel and tungsten measurements have both been accepted into the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The nickel benchmark was the first ICSBEP-accepted evaluation of measurements using the Feynman Variance-to-Mean method based on the Hage-Cifarelli formulism, and was the culmination of many years of subcritical experiment research. To help establish a protocol for research reactor-based subcritical measurements, a series of Critical and Subcritical {Phi}-Power Experiments at Rensselaer (CaSPER) have been designed. This neutron multiplication measurement series will be executed at the Rensselaer Polytechnic Institute Walthousen Reactor Critical Facility (RPI-RCF) in upstate New York. The RPI reactor facility can provide benchmark-quality integral experimental configurations where different reactivity states can be achieved by varying the control rod height/water height in the reactor. The diversity of achievable configurations are also unique in contrast to previous subcritical benchmark measurements in that they are spatially complex, involve different materials (fuel, moderator), and are characterized by system-specific neutron cross section sensitivities (various energy ranges and neutron reaction contributions). It is worth noting that previous proof-of-concept subcritical measurements have been performed on thermal systems at NCERC, at a variety of reactivity states by separation distance, yet it was not possible to know the reactivity of various configurations accurately for benchmarking (there are no control rod worth curves as there are no control rods). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols

Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatric patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.

60 APPLIED LIFE SCIENCES↗

Synthesis, characterization, and in vitro anticancer evaluation of 2-substituted 5-arylsulfonyl-1,3-oxazole-4-carbonitriles

In this series, six new 2-substituted 5-arylsulfonyl-1,3-oxazole-4-carbonitriles were synthesized and characterized by IR, {sup 1}H NMR, {sup 13}C NMR spectroscopy, elemental analysis and chromato-mass-spectrometry. The anticancer activities of the compounds were evaluated via single high dose (10{sup −5}M) against 60 cancer cell lines by the National Cancer Institute according to its own screening protocol. In the next phase, the compounds have been selected for five-dose assay. All synthesized compounds displayed growth inhibitory (GI50) and cytostatic activities (TGI) against the most sensitive cell lines at submicromolar (0.2–0.6 μM) and micromolar concentrations (1–3 μM), respectively. Cytotoxic activity (LC{sub 50}) of these compounds, with the exception of 4d, against the most sensitive cell lines was also high (5–6 μM). All compounds exhibit high selectivity towards leukemia cell lines, and among them, 4e and 4f showed the best antiproliferative and cytostatic selectivity. Compounds 4c and 4f displayed considerable cytotoxic selectivity towards the renal and breast cancer subpanels. Our results provided evidence for anticancer activities of novel 2-substituted 5-arylsulfonyl-1,3-oxazole-4-carbonitriles which could be useful for developing new anticancer drugs. These substances could also be used as an excellent framework in anticancer research that may lead to discovery of potent antitumor agents.

60 APPLIED LIFE SCIENCES↗

Aggregate attack surface management for network discovery of operational technology

Interconnectivity has become a substratum of technology as the benefits of data-driven functionality are being realized in nearly all industries. Increased connectivity of Operational Technology (OT) exacerbates cyber risks because Industrial Control Systems (ICS) are becoming exposed to the Internet. These exposures are often done inadvertently through misconfigurations as additional network devices come online. Attack surface management (ASM) platforms can be used to identify vulnerabilities by performing external network discovery over the Internet using web spiders. These web spiders enable big data analytics of Internet of Things (IoT) devices as identifiable information of Internet-exposed equipment are archived in searchable databases that are made publicly available. There are a multitude of ASM service providers on the market. Here, this study was conducted to evaluate several commonly known tools to determine the aggregate attack surface of control systems. Queries were crafted by targeting commonly known manufacturers and communication protocols found in OT networks. Identified devices were that categorized based on technology types. Each query was replicated between several tools to target identical ICS equipment. Findings in this paper suggested a significant variance in the exposures discovered by each tool, but unique contributions were identified for each tool when a merged attack surface was derived. Therefore, all tools should be used in aggregate.

97 MATHEMATICS AND COMPUTING↗

Analysis of sensitivity and rapid hybridization of a multiplexed Microbial Detection Microarray

Microarrays have proven to be useful in rapid detection of many viruses and bacteria. Pathogen detection microarrays have been used to diagnose viral and bacterial infections in clinical samples and to evaluate the safety of biological drug materials. A multiplexed version of the Lawrence Livermore Microbial Detection Array (LLMDA) was developed and evaluated with minimum detectable concentrations for pure unamplified DNA viruses, along with mixtures of viral and bacterial DNA subjected to different whole genome amplification protocols. In addition the performance of the array was tested when hybridization time was reduced from 17 h to 1 h. The LLMDA was able to detect unamplified vaccinia virus DNA at a concentration of 14 fM, or 100,000 genome copies in 12 μL of sample. With amplification, positive identification was made with only 100 genome copies of input material. When tested against human stool samples from patients with acute gastroenteritis, the microarray detected common gastroenteritis viral and bacterial infections such as rotavirus and E. coli. Accurate detection was found but with a 4-fold drop in sensitivity for a 1 h compared to a 17 h hybridization. The array detected 2 ng (equivalent concentration of 15.6 fM) of labeled DNA from a virus with 1 h hybridization without any amplification, and was able to identify the components of a mixture of viruses and bacteria at species and in some cases strain level resolution. Sensitivity improved by three orders of magnitude with random whole genome amplification prior to hybridization; for instance, the array detected a DNA virus with only 20 fg or 100 genome copies as input. This multiplexed microarray is an efficient tool to analyze clinical and environmental samples for the presence of multiple viral and bacterial pathogens rapidly.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive Circuit Learning for Quantum Metrology

Quantum sensing is an important application of emerging quantum technologies. We explore whether a hybrid system of quantum sensors and quantum circuits can surpass the classical limit of sensing. In particular, we use optimization techniques to search for encoder and decoder circuits that scalably improve sensitivity under given application and noise characteristics. Furthermore, our approach uses a variational algorithm that can learn a quantum sensing circuit based on platform-specific control capacity, noise, and signal distribution. The quantum circuit is composed of an encoder which prepares the optimal sensing state and a decoder which gives an output distribution containing information of the signal. We optimize the full circuit to maximize the Signal-to-Noise Ratio (SNR). Furthermore, this learning algorithm can be run on real hardware scalably by using the "parameter-shift" rule which enables gradient evaluation on noisy quantum circuits, avoiding the exponential cost of quantum system simulation. We demonstrate up to 13.12x SNR improvement over existing fixed protocol (GHZ), and 3.19x Classical Fisher Information (CFI) improvement over the classical limit on 15 qubits using IBM quantum computer. More notably, our algorithm overcomes the decreasing performance of existing entanglement-based protocols with increased system sizes.

42 ENGINEERING↗

A Benthic Habitat Monitoring Approach for Marine and Hydrokinetic Sites (Final Technical Report)

This final technical report summarizes the work completed as part of the Standardized and Cost-Effective Benthic Habitat Mapping and Monitoring Tools for MHK Environmental Assessments project funded by U.S. Department of Energy (DOE) under contract DE-EE007826 to Integral Consulting Inc. The overall goal of this project was to demonstrate a consistent, repeatable, and semi-automated seafloor and sediment mapping approach for rapidly characterizing benthic physical and biological/habitat conditions to support marine environmental assessments for marine and hydrokinetic energy sites. The approach evaluated combines sediment profile imaging and plan view (SPI/PV) technology with multibeam echosounder surveys as an effective and low-cost benthic habitat mapping protocol. A key innovation was the development of a semi-automated computer vision system that standardizes the extraction of data from the SPI/PV images. Other elements of the project were SPI camera hardware modifications, including the design and fabrication of a prototype “power” SPI camera to improve camera prism penetration in firm substrates, and outreach to agency regulators and other stakeholders on this habitat mapping approach. This technical report consists of five main subsections that summarize: 1) the benthic mapping approach; 2) benthic mapping results from the three areas’ surveys; 3) the development and performance of the image processing algorithms; 4) SPI camera hardware improvements and prototype testing; and 5) the regulatory outreach efforts.

16 TIDAL AND WAVE POWER↗

The REPACT Tool: User Manual [Slides]

Reuse of Existing Pipelines for Adapted Carbon Transport (REPACT) is an Excel-based screening tool. This tool enables the user to determine whether a pipeline originally deployed for natural gas transport, can be reused for CO 2 transport. The tool along with its associated users manual walk through an intended usage statement, setup instructions, a list of inputs and outputs in the tool, and frequently used protocols. Please note that this is a first-pass screening tool. The approach presented within this tool is valid for high-level evaluation only and should not be used to make engineering, financial, and/or regulatory decisions. Access the tool here: https://www.netl.doe.gov/energy-analysis/details?id=c699a604-ded1-45cd-b1c0-247b1405aeeb

03 NATURAL GAS↗

ETF Grout Expansion: Effects of Different Slags and Struvite Precipitation Protocols (Stirring Time)

The ETF ammonia tolerant grout waste form was developed by the Vitreous State Laboratory (VSL) to stabilize ammonium and thereby prevent emission of ammonia vapor during solidification of an ammonium-rich, concentrated sodium sulfate aqueous waste stream generated at the Hanford Effluent Treatment Facility (ETF). VSL personnel did not observe expansion in samples prepared during the waste form development work. However, Savannah River National Laboratory (SRNL) personnel detected expansion, in a few ETF grout samples, up to ~ 20 percent vertical expansion, while preforming work scope to evaluate the effect of ETF brine compositional ranges on the precipitation and solidification processes. The initial work requests can be found in Washington River Protection Services (WRPS) Statement of Work (SOW, Requisitions #: 339922 Revisions 0 and 1, March 11, 2021, and November 2021, respectively. As a result of the waste form expansion observed by SRNL, additional evaluation was requested by WRPS SOW Requisitions #: 356730 Revision 0 and Revision 1, February 1, 2022, and July 11, 2022, respectively. The goal of these requests was to determine whether differences in the slags and / or in sample preparation protocols used by VSL and SRNL were the cause of the expansion observed in the SRNL samples. G. Chen, WRPS, arranged a materials exchange between VSL and SRNL and coordinated the VSL protocol(s) for grouting and curing 1L batches of Base Case ETF base case simulant. Materials were exchanged between VSL and SRNL. Both laboratories performed the VSL struvite precipitation-solidification protocol and cured samples for at least 28 days. Differences in VSL and SRNL slag compositions, mineralogy and particle size results in themselves or combined were determined to not be the cause of the expansion because all samples expanded regardless of whether the VSL or SRNL slags were used. The fundamental cause of the observed expansion could not be attributed to minor variations in the following: 1) chemistry of the slag and other reagents, 2) container wall thickness, 3) ambient bench top curing conditions at VSL and SRNL, 4) pH adjustments to 7 ± a few tenths of unit, nor 5) stirring time between the precipitation and solidification process steps. Additional observations include: grout samples prepared with VSL slag expanded less than those prepared with the SRNL slag and, based on a very limited sample set, some samples stirred for longer times expanded less than those stirred for 20 minutes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗