Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Observations of a plectonemic configuration in a stable magnetized plasma jet

Astrophysical jets are collimated high-speed outflows emerging from spinning and accreting matter around celestial objects and may spontaneously result from self-organized processes. Magnetic self-organization is commonly observed in laboratory plasma physics experiments; however, they require close-fitting flux conservers to constrain and stabilize the toroidal or cylindrical structures. Here we report the first observations of a long, stable, free-boundary plasma jet far from chamber walls, embedding a double-helix magnetic structure resembling a force-free plectonemic Taylor state. The jets arise from an experimental setup that mimics an accretion disk and has no close-fitting solid flux conserver. The results support the hypothesis that self-organization could be a universal, intrinsic explanation for jet formation, collimation, and stability and may help explain double-helix features in celestial observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

The crucial role of diagnostics in achieving ignition on the National Ignition Facility (NIF)

Well over 100 diagnostics can operate on the National Ignition Facility (NIF) as a result of several decades of development on NIF, and before that on Nova, OMEGA, and earlier LLNL lasers. A subset of these have guided the approach to achieving ignition on the NIF in 2022 [H. Abu-Shawareb et al. (Indirect Drive ICF Collaboration), Phys. Rev. Lett. 129(7), 075001 (2022)]. Achieving ignition on NIF has required many types of experiments with this core set of diagnostics, some constraining known unknowns and some revealing surprises—arguably unknown unknowns. Early design work realized that the extreme precision required for ignition on NIF would require fine-tuning by experiment, that is, measuring and adjusting known unknowns. Many examples are given where the use of the core set of ignition diagnostics in experimental arrangements called platforms demonstrated control of the key theoretical parameters defined as shape, adiabat, velocity, and mix. The direction of the adjustments to input conditions is found either by trend analysis or, in many cases, by observing from the diagnostic data the direction to make an adjustment. In addition, diagnostics have revealed some unexpected or neglected known issues, which degrade performance, or unexpected issues, unknown unknowns. Some of these factors had been previously considered, but underestimated or difficult to calculate at the time. The overall methodology can be described as a variant of Popper's falsifiability philosophy [K. Popper, The Logic of Scientific Discovery (Hutchinson, 1974)]. This paper summarizes the role of ignition diagnostics in terms of falsification or validation of theory or experimental setup as well as uncovering unexpected issues. The journey to ignition started in the seventies with a 1-µm wavelength laser producing disastrous results. Diagnostics have guided us to the recent multi-decadal goal of demonstrating ignition and burn in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lasing characteristics of the Ar - Xe and He - Ar - Xe mixtures pumped by fission fragments

The lasing characteristics of the Ar - Xe and He - Ar - Xe mixtures emitting at the transitions of the Xe atom at 1.73 and 2.026 mkm upon pumping by fission fragments in the BARS-6 pulsed reactor are studied. We describe an experimental setup and methods for measuring laser beam parameters and characteristics of the active medium of the nuclear-pumped laser in the free-running and master oscillator - amplifier regimes. The dependences of the laser pulse energy on the resonator parameters and the composition and pressure of the working mixture are studied in the free-running regime. A method of modulating the input signal of a single-pass amplifier is proposed for obtaining lasing characteristics of active mixtures. The lasing characteristics of the Ar - Xe and He - Ar - Xe mixtures (the unsaturated gain, saturation intensity, conversion efficiency, etc.) are determined from experiments in the amplifier - oscillator regime and compared with the results reported in other papers. (lasers)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Angular distribution of light scattered from heavily doped silica fibres

This paper describes an experimental setup for precision measurements of the angular distribution of light scattered by optical fibres in a wide angular range and demonstrates that the models of anomalous scattering proposed to date need to be refined. We have found and interpreted a discrepancy between the Rayleigh scattering coefficients measured by different techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of an average output power of a CuBr laser

We have studied the pump parameters of a CuBr laser (pulse repetition rate of 14 kHz) with an independent heating of the active medium and an additional excitation source, providing an operational control of the radiation parameters in a given time interval. We have fabricated an experimental setup that makes it possible to change the average output power by applying a control pulse which is ahead of the main pulse by 0.12 - 20 {mu}s. It is shown that to ensure the effective control of the laser power, the voltage amplitude of the additional excitation pulse should be within 12 % - 28 % of the main pulse amplitude. In this case, the proposed control regime allows a 2.5-fold decrease in the time delay between the control and main excitation pulses due to a higher energy of the additional pulse compared to self-heating regime of the laser operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

32.8-nm X-ray laser produced in a krypton cluster jet

We have interpreted the well-known experimental quantum yield data for a 32.8-nm X-ray laser operating at the 3d{sup 9}4d (J = 0) – 3d{sup 9}4p (J = 1) transition of Kr{sup 8+} with the use of gaseous krypton or a krypton cluster jet. Proceeding from our model we propose a novel scheme for the 32.8-nm laser produced in a krypton cluster jet. The quantum yield is shown to saturate for a plasma length of ∼300 μm, a krypton ion density n{sub Kr} ∼ (4 – 9) × 10{sup 19} cm{sup -3}, and an electron temperature Te ∼ 5000 eV. In this case, the energy conversion coefficient amounts to ∼5 × 10{sup -3} of the pump pulse energy. We propose the experimental setup for producing a highefficiency subpicosecond X-ray laser in a krypton cluster jet. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of nanovibration amplitudes using frequency-modulated semiconductor laser autodyne

The method for measuring nanovibration amplitudes using the autodyne signal of a semiconductor laser at several laser radiation wavelengths is described. The theoretical description of the frequency-modulated autodyne signal under harmonic vibrations of the reflector is presented and the relations for its spectral components are derived using the expansions into the Fourier and Bessel series. The results of numerical modelling based on the proposed method for measuring the reflector nanovibration amplitudes are presented that make use of the low-frequency spectrum of the autodyne signal from the frequency-modulated laser autodyne and the solution of the appropriate inverse problem. The experimental setup is described; the results of the measurements are presented for the nanovibration amplitudes and the autodyne signal spectra under the reflector nanovibrations. (laser applications and other topics in quantum electronics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simplified algorithm for measuring erythrocyte deformability dispersion by laser ektacytometry

The possibility of measuring the dispersion of red blood cell deformability by laser diffractometry in shear flow (ektacytometry) is analysed theoretically. A diffraction pattern parameter is found, which is sensitive to the dispersion of erythrocyte deformability and to a lesser extent – to such parameters as the level of the scattered light intensity, the shape of red blood cells, the concentration of red blood cells in the suspension, the geometric dimensions of the experimental setup, etc. A new algorithm is proposed for measuring erythrocyte deformability dispersion by using data of laser ektacytometry. (laser applications in medicine)

60 APPLIED LIFE SCIENCES↗

Ionisation response in semiconductor structures exposed to the X-ray radiation of a femtosecond laser-plasma source

The possibilities of applying a femtosecond laser-plasma source of X-ray radiation for modelling the effect of single nuclear particles based on the principle of equivalent charge generation are analysed. The parameters of femtosecond X-ray radiation for the experimental modelling of individual radiation effects are validated. The experimental setup forming the X-ray radiation is described. The results of comparative ionisation response modelling in simple electronic devices using the FLUKA and FEANT codes are presented. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of clustering of CF{sub 3}Br molecules with argon atoms by CO{sub 2} laser radiation in gas-dynamic expansion of a CF{sub 3}Br–Ar mixture: bromine isotope selectivity

We present the study of suppressing the clustering of CF{sub 3}Br molecules with argon atoms under gas-dynamic expansion of the CF{sub 3}Br–Ar mixture at a nozzle exit by a cw CO{sub 2} laser. The main attention is paid to the analysis of possibility of implementing the selective control of bromine isotope clustering. The method relies on the vibrational excitation of molecules with the laser radiation, which leads to the suppression of their clustering with argon atoms. The experimental setup and the method of study are briefly described. The results of evaluation of the efficiency and selectivity of suppression of molecular–atomic clustering for different compositions of the gas above the nozzle and separations between the irradiation zone and the nozzle exit section are presented. It is shown that under the resonance vibrational excitation of gas-dynamically cooled CF{sub 3}Br molecules at the nozzle exit one can implement bromine isotope selective suppression of clustering of molecules with argon atoms. It is found that by controlling the clustering of CF{sub 3}Br molecules with argon atoms one can implement considerably higher enrichment and selectivity factors than in the case of controlling the clustering of CF{sub 3}Br molecules with each other. Thus, using the CF{sub 3}Br–Ar mixture (the ratio of pressures 1 : 100 and 1 : 200) the enrichment factors for the bromine isotopes K{sub enr}({sup 81}Br) = 1.50 ± 0.13 and 1.30 ± 0.09, respectively, were obtained under the conditions of irradiating the jet at the 9R(30) line of the laser (ν = 1084.635 cm{sup −1}). The selectivity α of the suppression of clustering of CF{sub 3}Br molecules with argon atoms, achieved in this case, amounted to 4.02 ± 0.19 and 2.31 ± 0.11, respectively. The results show that the method allows one to selectively control the clustering of molecules, comprising isotopes of heavy elements that possess a small isotopic shift in the IR absorption spectra. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of a fully resolved contour of the carbon dioxide absorption line in a band at λ = 1.605 μm in the atmospheric column using high-resolution heterodyne spectroradiometry

We consider the application of the heterodyne signal detection technique to measure the atmospheric transmission spectrum in the near-IR range, which makes it possible to measure for the first time the contour of a separate line of the vibrational – rotational CO{sub 2} band on the solar observation path with a high spectral resolution of λ/δλ = 10{sup 8}. Together with other characteristics of the instrument, this enables us to measure the carbon dioxide content in the atmospheric column with high accuracy. The experimental setup and measurement technique are described. The existing facilities for measuring the content of greenhouse gases in the atmosphere are compared, demonstrating the possibility of using the near-IR heterodyne spectroradiometry to develop a useful and competitive instrument that can be used in building new networks of ground stations to monitor greenhouse gases. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Infrared laser-induced isotope-selective dissociation of mixed (CF{sub 3}Br){sub m}Ar{sub n} van der Waals clusters

The paper presents the results of studies of IR laser-induced bromine-isotope-selective dissociation of small mixed (CF{sub 3}Br){sub m}Ar{sub n} van der Waals clusters (m = 1, 2 and 1 ≤ n ≤ 5 is the number of molecules and atoms in the clusters, respectively). The experiments used a pulsed CO{sub 2} laser to excite clusters and a quadrupole mass spectrometer to detect a molecular cluster beam. The research method is based on the selective vibrational excitation of clusters by IR laser radiation, leading to their predissociation. The possibilities of implementing bromine-isotope-selective dissociation of clusters are considered. The experimental setup and research method are briefly described. The results of determining the cluster dissociation efficiency and selectivity as functions of the energy and frequency of laser radiation are presented. It is shown that resonant vibrational excitation of clusters makes it possible to induce their isotope-selective dissociation. Thus, using a CF{sub 3}Br/Ar mixture with a pressure ratio of 1/200, the enrichment factors of the {sup 79}Br isotope are found to be K{sub enr}({sup 79}Br) = 1.15 ± 0.04 and 0.95 ± 0.03 under cluster irradiation conditions on the 9R(30) (ν = 1084.635 cm{sup −1}) and 9R(24) (ν = 1081.087 cm{sup −1}) lines, respectively The achieved dissociation selectivities for the clusters are, respectively, 1.16 ± 0.05 and 0.95 ± 0.04. The results obtained suggest that this method can be used to separate isotopes in molecules containing isotopes of heavy elements, which have a slight isotopic shift in the IR absorption spectra. (laser isotope separation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Nd : YAG laser radiation (λ = 1.44 mm) on myocardial tissue in the treatment of coronary heart disease by transmyocardial laser revascularisation

We have studied the impact of Nd : YAG laser radiation with a wavelength of λ = 1.44 μm on the myocardial tissue for the formation of channels in the treatment of coronary heart disease by transmyocardial laser revascularisation (TMLR). The mechanism of perforation of the myocardial tissue by a laser pulse is presented and an experimental setup for TMLR is developed. In experiments on biological objects, the optimal parameters of radiation energy and duration necessary for the formation of channels of a given size in a single laser pulse are determined. The exposure regime ensures the adequate character of myocardial tissue destruction, assessed by such criteria as the perforation force, exposure energy, size of the coagulation zone, and level of carbonisation. (laser medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution deep view microscopy of cells and tissues

Methods, experimental setups and perspectives of three-dimensional deep view imaging microscopy of cell or tissue samples are reported. Preliminary biophysical and clinically relevant examples are presented. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗