Search NASA⌕ Search

SEARCH · Search NASA

Results for “fiber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

The Acousto‐Optic Effect in Microstructured Optical Fibers

The acousto‐optic effect has been successfully used since the early 80’s in the design and construction of a variety of conventional optical fiber devices such as frequency shifters, couplers, filters and modulators. Acoustic waves can be employed to modulate the spectrum and switch the wavelength of conventional fiber Bragg gratings as well as for controlling the Q‐switching in distributed fiber lasers. Tunable devices induced by acoustic waves have also been demonstrated in photonic crystal fibers (PCF), whereas a resonance dip corresponding to an excited cladding mode can be tuned over the wavelength. In a similar work, but inducing an acoustic excitation over the longitudinal axis, long period gratings can be created in the transmission band of a solid core PCF. Recently, the availability of Bragg gratings in photonic crystal fibers enables several applications, particularly if their properties can be controlled in order to produce modulation or allow tunability. A way of achieving these effects is through the excitation of acoustic waves in the fibre, which allows a rapid method for shifting or modulating the Bragg wavelength. In this work the application of acoustic‐waves to microstructured fibers is reviewed and recent results on the modulation of fiber Bragg gratings in photonic crystal fibers are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized coupling of cold atoms into a fiber using a blue-detuned hollow-beam funnel

We theoretically investigate the process of coupling cold atoms into the core of a hollow-core photonic-crystal optical fiber using a blue-detuned Laguerre-Gaussian beam. In contrast to the use of a red-detuned Gaussian beam to couple the atoms, the blue-detuned hollow beam can confine cold atoms to the darkest regions of the beam, thereby minimizing shifts in the internal states and making the guide highly robust to heating effects. This single optical beam is used as both a funnel and a guide to maximize the number of atoms into the fiber. In the proposed experiment, Rb atoms are loaded into a magneto-optical trap (MOT) above a vertically oriented optical fiber. We observe a gravito-optical trapping effect for atoms with high orbital momentum around the trap axis, which prevents atoms from coupling to the fiber: these atoms lack the kinetic energy to escape the potential and are thus trapped in the laser funnel indefinitely. We find that by reducing the dipolar force to the point at which the trapping effect just vanishes, it is possible to optimize the coupling of atoms into the fiber. Our simulations predict that by using a low-power (2.5 mW) and far-detuned (300 GHz) Laguerre-Gaussian beam with a 20-{mu}m-radius core hollow fiber, it is possible to couple 11% of the atoms from a MOT 9 mm away from the fiber. When the MOT is positioned farther away, coupling efficiencies over 50% can be achieved with larger core fibers.

74 ATOMIC AND MOLECULAR PHYSICS↗

Upscaling of asymmetric hollow fiber‐supported thin film membranes for oxygen separation from air: Proof of concept

Abstract Hollow fiber membranes demonstrate various advantages for high performance oxygen separation. However, the small diameters of hollow fibers and the brittleness of ceramics limit their mechanical strength, imposing great difficulties on stack and module development. Gas‐tight sealing is another challenge for upscaling of hollow fiber membrane technology. Low temperature sealant materials of epoxy resin or silicon are typically used for hollow fiber stacks, requiring that the sealing portions be located out of hot zone. Consequently, only partial length of hollow fibers participates in oxygen permeation. In this study, upscaling of our recently developed asymmetric hollow fiber‐supported thin film membranes is conducted, where individual hollow fibers are assembled in parallel to form a stack. A reliable gas‐tight sealing is obtained by combining ceramic paste with conductive adhesive ink cohesively. Comprehensive oxygen permeation test is conducted with the sealing portions being in hot zone and compared with a single hollow fiber membrane. Fundamental mechanism is discussed to understand the performances and their differences. An accelerated long‐term test (∼320 h, 16 thermal cycles) demonstrates excellent stability and robustness of the stack and sealing. The characterization of post‐test samples further confirms excellent stability and robustness of the phases and microstructures of the stack.

36 MATERIALS SCIENCE↗

Development of a flexible optical fiber based high resolution integrated PET/MRI system

Purpose: The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET/MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce the problem, the authors newly developed flexible optical fiber bundle based block detectors and employed them for a high resolution integrated PET/MRI system. Methods: The flexible optical fiber bundle used 0.5 mm diameter, 80 cm long double clad fibers which have dual 12 mm Multiplication-Sign 24 mm rectangular inputs and a single 24 mm Multiplication-Sign 24 mm rectangular output. In the input surface, LGSO scintillators of 0.025 mol.% (decay time: {approx}31 ns: 0.9 mm Multiplication-Sign 1.3 mm Multiplication-Sign 5 mm) and 0.75 mol.% (decay time: {approx}46 ns: 0.9 mm Multiplication-Sign 1.3 mm Multiplication-Sign 6 mm) were optically coupled in depth direction to form depth-of-interaction detector, arranged in 11 Multiplication-Sign 13 matrix and optically coupled to the fiber bundle. The two inputs of the bundle are bent for 90 Degree-Sign , bound to one, and are optically coupled to a Hamamatsu 1-in. square position sensitive photomultiplier tube. Results: Light loss due to the fiber bundle could be reduced and the performance of the block detectors was improved. Eight optical fiber based block detectors (16 LGSO blocks) were arranged in a 56 mm diameter ring to form a PET system. Spatial resolution and sensitivity were 1.2 mm full-width at half-maximum and 1.2% at the central field-of-view, respectively. Sensitivity change was less than 1% for 2 Degree-Sign C temperature changes. This PET system was integrated with a 0.3 T permanent magnet MRI system which has 17 cm diameter hole at the yoke area for insertion of the PET detector ring. There was no observable interference between PET and MRI. Simultaneous imaging of PET and MRI was successfully performed for small animal studies. Conclusions: The authors confirmed that the developed high resolution PET/MRI system is promising for molecular imaging research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D tomodosimetry using long scintillating fibers: A feasibility study

Purpose: 3D dosimetry is recognized as an ideal for patient-specific quality assurance (QA) of highly conformal radiotherapy treatments. However, existing 3D dosimeters are not straightforward to implement in the clinic, as their read-out procedure is often tedious and their accuracy, precision, and/or sample size exhibit limitations. The purpose of this work is to develop a 3D dosimeter based on the concept of tomodosimetry inside concentric cylindrical planes using long scintillating fibers for the QA of modern radiotherapy techniques such as intensity-modulated radiation therapy (IMRT) or intensity-modulated arc therapy (IMAT).Methods: Using a model-based simulation, scintillating fibers were modeled on three concentric cylindrical planes of radii 2.5, 5.0, and 7.5 cm, inside a 10 cm radius water-equivalent cylinder phantom. The phantom was set to rotate around its central axis, made parallel to the linac gantry axis of rotation. Light acquisitions were simulated using the calculated dose from the treatment planning software and reconstructed in each cylindrical plane at a resolution of 1 mm{sup 2} using a total-variation minimization iterative reconstruction algorithm. The 3D dose was then interpolated from the reconstructed cylindrical plane doses at a resolution of 1 mm{sup 3}. Different scintillating fiber patterns were compared by varying the angle of each fiber in its cylindrical plane and introducing a light-tight cut in each fiber. The precision of the reconstructed cylindrical dose distribution was evaluated using a Poisson modeling of the acquired light signals and the accuracy of the interpolated 3D dose was evaluated using an IMRT clinical plan for a prostate case.Results: Straight scintillating fiber patterns with light-tight cuts were the most accurate in cylindrical dose reconstruction, showing less than 0.5 mm distance-to-agreement in dose gradients and a mean local dose difference of less than 0.2% in the high dose region for a 10 × 10 cm{sup 2} field. The precision attained with this fiber configuration was less than 0.9% in the high dose, low gradient region of an IMRT segment for light acquisitions of 0.1 MU over a 360 degree rotation of the cylinder phantom. 3D dose interpolation for the IMRT clinical plan yielded an overall dose difference with the reference input of less than 1%, except in high dose gradients.Conclusions: Using long scintillating fibers inside rotating, concentric cylindrical planes, the authors demonstrate that their tomodosimetry method has the potential for high resolution, precise, and accurate 3D dosimetry. Moreover, because of its water-equivalence and rotational symmetry, this design should find interesting application for both treatment QA and machine commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-166: On the Nature of the Background Visible Light Observed in Fiber Optic Dosimetry of Proton Beams

Purpose: The nature of the background visible light observed during fiber optic dosimetry of proton beams, whether it is due to Cherenkov radiation or not, has been debated in the literature recently. In this work, experimentally and by means of Monte Carlo simulations, we shed light on this problem and investigated the nature of the background visible light observed in fiber optics irradiated with proton beams. Methods: A bare silica fiber optics was embedded in tissue-mimicking phantoms and irradiated with clinical proton beams with energies of 100–225 MeV at Roberts Proton Therapy Center. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze in detail the emission spectrum of the fiber tip across the visible range of 400–700 nm. Monte Carlo simulation was performed by using FLUKA Monte Carlo code to simulate Cherenkov light and ionizing radiation dose deposition in the fiber. Results: The experimental spectra of the irradiated silica fiber shows two distinct peaks at 450 and 650 nm, whose spectral shape is different from that of Cherenkov radiation. We believe that the nature of these peaks are connected to the point defects of silica including oxygen-deficiency center (ODC) and non-bridging oxygen hole center (NBOHC). Monte Carlo simulations confirmed the experimental observations that Cherenkov radiation cannot be solely responsible for such a signal. Conclusion: We showed that Cherenkov radiation is not the dominant visible signal observed in bare fiber optics irradiated with proton beams. We observed two distinct peaks at 450 and 650 nm whose nature is connected with the point defects of silica fiber including oxygen-deficiency center and non-bridging oxygen hole center.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-07: Measurement of Real-Time Dose for Tandem and Ovoid Brachytherapy Procedures Using a High Precision Optical Fiber Radiation Detector

Purpose: Development of a novel on-line dosimetry tool is needed to move toward patient-specific quality assurance measurements for Ir-192 HDR brachytherapy to verify accurate dose delivery to the intended location. This work describes the development and use of a nano-crystalline yttrium oxide inorganic scintillator based optical-fiber detector capable of acquiring real-time high-precision dose measurements during tandem and ovoid (T&O) gynecological (GYN) applicator Ir-192 HDR brachytherapy procedures. Methods: An optical-fiber detector was calibrated by acquiring light output measurements in liquid water at 3, 5, 7, and 9cm radial source-detector-distances from an Ir-192 HDR source. A regression model was fit to the data to describe the relative light output per unit dose (TG-43 derived) as a function of source-detector-distance. Next, the optical-fiber detector was attached to a vaginal balloon fixed to a Varian Fletcher-Suit-Delclos-style applicator (to mimic clinical setup), and localized by acquiring high-resolution computed tomography (CT) images. To compare the physical point dose to the TPS calculated values (TG-43 and Acuros-BV), a phantom measurement was performed, by submerging the T&O applicator in a liquid water bath and delivering a treatment template representative of a clinical T&O procedure. The fiber detector collected scintillation signal as a function of time, and the calibration data was applied to calculate both real-time dose rate, and cumulative dose. Results: Fiber cumulative dose values were 100.0cGy, 94.3cGy, and 348.9cGy from the tandem, left ovoid, and right ovoid dwells, respectively (total of 443.2cGy). A plot of real time dose rate during the treatment was also acquired. The TPS values at the fiber location were 458.4cGy using TG-43, and 437.6cGy using Acuros-BV calculated as Dm,m (per TG-186). Conclusion: The fiber measured dose value agreement was 3% vs TG-43 and −1% vs Acuros-BV. This fiber detector opens up new possibilities for performing patient-specific quality assurance for Ir-192 HDR GYN procedures. Funding from Coulter Foundation, Duke Bio-medical Engineering. Company is being created around the detector technology. Duke holds patents on the technology.

60 APPLIED LIFE SCIENCES↗

Fiber optic quench detection via optimized Rayleigh Scattering in high-field YBCO accelerator magnets

Yttrium barium copper oxide (YBCO) coated conductors are known for their ability to operate in the superconducting state at relatively high temperatures, even above the boiling point of liquid nitrogen (77 K). When these same conductors are operated at lower temperatures, they are able to operate in much higher magnetic fields than traditional superconductors like NiTi or Nb 3 Sn. Thus, YBCO superconducting magnets are one of the primary options for generating the high magnetic fields needed for future high energy physics devices. Due to slow quench propagation, quench detection remains one of the primary limitations to YBCO magnets. Fiber optic sensing, based upon Rayleigh scattering, has the potential for spatial resolution approaching the wavelength of light, or very fast temporal resolution at low spatial resolution, and a continuum of combinations in between. This project has studied, theoretically and experimentally, YBCO magnets and Rayleigh scattering quench detection systems to demonstrate feasibility of the systems for YBCO quench protection systems. Under this grant an experimentally validated 3D quench propagation model was used to accurately define the acceptable range of spatial and temporal resolutions for effective quench detection in YBCO magnets and to evaluate present-day and potentially improved YBCO conductors. The data volume and speed requirements for quench detection via Rayleigh scattering required the development of a high performance fiber optic based quench detection/data acquisition system and its integration with an existing voltage tap/thermo-couple based system. In this project, optical fibers are tightly co-wound into YBCO magnet coils, with the fiber on top of the conductor as turn-to-turn insulation. Local changes in the temperature or strain of the conductor are sensed by the optical fiber, which is in close thermal and mechanical contact with the conductor. Intrinsic imperfections in the fiber reflect Rayleigh backscattered laser signals that are shifted by the changes in the fiber that are induced by a local change in the YBCO temperature or strain. One goal of this project was to show that modern technology can be used to interrogate the signals from a (very expensive) YBCO magnet to detect an impending quench in time to protect it from self-destruction. The results show that Rayleigh-backscattering interrogated optical fibers (RIOF) have significant advantages over traditional techniques, including very high spatial resolution and the ability to detect a hot-spot well before the peak local temperature becomes so high that the conductor can be damaged. RIOF quench detection is intrinsically faster than voltage taps, and this intrinsic advantage is greater as the coil size and/or current margin increases. We describe the development and testing program performed under the grant.

43 PARTICLE ACCELERATORS↗

Precursor Processing Development for Low Cost, High Strength Carbon Fiber for Composite Overwrapped Pressure Vessel Applications

Carbon fiber (CF) is central to produce lightweight, high pressure, composite overwrapped pressure vessels (COPVs), which are used for on-board storage of hydrogen for fuel cell vehicles. In 2015, carbon fiber cost accounted for 62% of the cost of a hydrogen storage system, as COPVs were manufactured with T700S CF at $\$ $29.40/kg CF. The high cost of hydrogen storage, largely attributed to the carbon fiber cost, limits the application of fuel cells in vehicles. Therefore, our team endeavored to develop fiber processing to demonstrate carbon fiber tensile properties similar to T700S with a production cost potential of $\$ $12.60/kg or less. Here, the overarching goal of the project was the development of low cost, high strength carbon fiber for composite overwrapped pressure vessels. Within the project, our team investigated a new low-cost, high-volume, high quality polyacrylonitrile (PAN)-based precursor terpolymer for the production of carbon fiber precursors, methods for increasing water and energy use efficiency in wash-water/solvent separation, and ultimately developed a multifilament spinning and conversion process for the production of hollow carbon fibers from a segmented arc spinneret utilizing a solution spinning method.

08 HYDROGEN↗

Exploring internal structures and properties of terpolymer fibers via real-space characterizations

While significant research has investigated the processing and properties of high-performance terpolymer fibers, much remains to be understood about the internal nano- and microstructures of these fibers, and how these morphologies relate to fiber properties. Here we use a focused ion beam notch technique and multifrequency atomic force microscope mapping to characterize the internal structure and local mechanical properties within Technora ® fibers. We find a highly fibrillated structure that appears to connect with both the fiber’s molecular chemistry and full-fiber mechanical properties. In addition, through detailed comparisons with Kevlar ® K29 fibers, we find remarkable differences between the internal structures of the two fibers, and posit connections between our measurements and multifunctional performance studies from the literature.

36 MATERIALS SCIENCE↗

Unilateral lower limb suspension does not mimic bed rest or spaceflight effects on human muscle fiber function

We used Ca2+-activated skinned muscle fibers to test the hypothesis that unilateral lower leg suspension (ULLS) alters cross-bridge mechanisms of muscle contraction. Soleus and gastrocnemius biopsies were obtained from eight subjects before ULLS, immediately after 12 days of ULLS (post-0 h), and after 6 h of reambulation (post-6 h). Post-0 h soleus fibers expressing type I myosin heavy chain (MHC) showed significant reductions in diameter, absolute and specific peak Ca2+-activated force, unloaded shortening velocity, and absolute and normalized peak power. Fibers obtained from the gastrocnemius were less affected by ULLS, particularly fibers expressing fast MHC isoforms. Post-6 h soleus fibers produced less absolute and specific peak force than did post-0 h fibers, suggesting that reambulation after ULLS induced cell damage. Like bed rest and spaceflight, ULLS primarily affects soleus over gastrocnemius fibers. However, in contrast to these other models, slow soleus fibers obtained after ULLS showed a decrease in unloaded shortening velocity and a greater reduction in specific force.

NASA Discipline Musculoskeletal↗

Single mode fiber array for planet detection using a visible nulling interferometer

We report the design, fabrication, and testing of a coherent large mode field diameter fiber array to be used as a spatial filter in a planet finding visible nulling interferometer. The array is a key component of a space instrument for visible-light detection and spectroscopy of Earth like extrasolar planets. In this concept, a nulling interferometer is synthesized from a pupil image of a single aperture which is then spatially filtered by a coherent array of single mode fibers to suppress the residual scattered star light. The use of the fiber array preserves spatial information between the star and planet. The fiber array uses a custom commercial large mode field or low NA step-index single mode fiber to relax alignment tolerances. A matching custom micro lens array is used to couple light into the fibers, and to recollimate the light out of the fiber array. The use of large mode field diameter fiber makes the fabrication of a large spatial filter array with 300 to 1000 elements feasible.

fiber arrays↗

Time-Dependent Stress Rupture Strength Degradation of Hi-Nicalon Fiber-Reinforced Silicon Carbide Composites at Intermediate Temperatures

The stress rupture strength of silicon carbide fiber-reinforced silicon carbide composites with a boron nitride fiber coating decreases with time within the intermediate temperature range of 700 to 950 degree Celsius. Various theories have been proposed to explain the cause of the time-dependent stress rupture strength. The objective of this paper is to investigate the relative significance of the various theories for the time-dependent strength of silicon carbide fiber-reinforced silicon carbide composites. This is achieved through the development of a numerically based progressive failure analysis routine and through the application of the routine to simulate the composite stress rupture tests. The progressive failure routine is a time-marching routine with an iterative loop between a probability of fiber survival equation and a force equilibrium equation within each time step. Failure of the composite is assumed to initiate near a matrix crack and the progression of fiber failures occurs by global load sharing. The probability of survival equation is derived from consideration of the strength of ceramic fibers with randomly occurring and slow growing flaws as well as the mechanical interaction between the fibers and matrix near a matrix crack. The force equilibrium equation follows from the global load sharing presumption. The results of progressive failure analyses of the composite tests suggest that the relationship between time and stress-rupture strength is attributed almost entirely to the slow flaw growth within the fibers. Although other mechanisms may be present, they appear to have only a minor influence on the observed time-dependent behavior.

Progressive Failure Analysis↗

Thermomechanical Modeling of Woven Materials With Particle-Based, Explicit-Fiber Simulations

Fiber-based materials are extensively used to protect spacecraft during entry. Insulative fibers, often in a fiber network or woven, provide rigidity, strength, and control of material anisotropy and density. Woven thermal protection materials, such as ADEPT (Adaptable, Deployable Entry and Placement Technology), 3D-MAT (3-Dimensional Multifunctional Ablative Thermal Protection), and 3MDCP (3D Woven Mid-Density Carbon Phenolic), enable missions with stronger and denser materials for entry profiles with high shear and heat flux. Vulnerabilities to woven thermal protection materials include manufacturing-induced material property variation, and impact from micrometeoroids. Simulating woven materials under these conditions require models that can resolve hierarchal structures, thermomechanical behavior, and failure. To address this, we simulate weave thermal conduction and mechanical deformation. We simulate the full weave with a coarse-grained yarn model is presented. The model combines a validated, high-resolution single 3MDCP yarn model and phenolic resin model. Instead of modeling every fiber, each yarn ply with order 10, instead of order 1000, fibers. The discrete element bonded particle model (DEM-BPM) of fibers captures the thermal and mechanical behavior within and between fibers. We study the proportion of heat transfer and stress via the contact network, fiber bonds, and overall weave geometry.

bonded particle↗

2013 R&D 100 Award: New tech could mean more power for fiber lasers

An LLNL team of six physicists has developed a new technology that is a stepping stone to enable some of the limitations on high-power fiber lasers to be overcome. Their technology, dubbed "Efficient Mode-Converters for High-Power Fiber Amplifiers," allows the power of fiber lasers to be increased while maintaining high beam quality. Currently, fiber lasers are used in machining, on factory floors and in a number of defense applications and can produce tens of kilowatts of power.The conventional fiber laser design features a circular core and has fundamental limitations that make it impractical to allow higher laser power unless the core area is increased. LLNL researchers have pioneered a design to increase the laser's core area along the axis of the ribbon fiber. Their design makes it difficult to use a conventional laser beam, so the LLNL team converted the beam into a profile that propagates into the ribbon fiber and is converted back once it is amplified. The use of this LLNL technology will permit the construction of higher power lasers for lower costs and increase the power of fiber lasers from tens of kilowatts of power to about 100 kilowatts and potentially even higher.

36 MATERIALS SCIENCE↗

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Single-mode Chalcogenide Optical Fiber for Mid-Infrared Applications

Chalcogenide fibers display a wide transmission window ranging from 2-10.6 μm, ideally suited to the development of passive and active mid-infrared (MIR) sensors. They are essential building blocks for the integration and miniaturization of laser-based MIR optical systems for terrestrial, airborne and space-based sensing platforms. Single-mode chalcogenide fibers have only recently become commercially available and therefore performance data and standard reproducible processing techniques have not been widely reported. In this paper we present a method for producing high quality facets on commercial single-mode As-Se fibers with core and cladding diameters of 28.1 and 169.9μm respectively. The emitted beam profile from these fibers, using the 9.4μm line of a tunable CO 2 laser, showed the presence of leaky cladding modes due to waveguiding conditions created by the protective acrylate jacket. These undesirable cladding modes were easily suppressed by applying a gallium coating on the cladding near both input and output facets. We provide experimental data of efficient mode suppression and the emission of a circular near-perfect Gaussian beam profile from the fiber. A model to determine appropriate placement of gallium coatings to minimize processing while maximizing cladding mode suppression is currently underway. Furthermore, analyses of the beam, acquired by scanning an HgCdTe detector, yielded a 1/e 2 numerical aperture of 0.11 with a full width half maximum divergence of 11° for these fibers. The availability of single-mode MIR fibers, in conjunction with recent advances in room temperature quantum cascade lasers (QCL), could provide compact and light-weight transmitter solutions for several critical defense and nuclear non-proliferation needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Preparation of Mesophase Pitch Feedstock for Carbon Fiber

A filtration process of the low cost mesophase pitch developed by Advanced Carbon Products, LLC (ACP) was developed. The mesophase pitch was melt spun into fiber at the University of Kentucky Center for Applied Energy Research (UKY), and converted to carbon fiber. The melt spinning process was moderately stable, but resulted in some void structure in the green fibers. The tensile properties of the resulting carbon fibers, after graphitization heat treatment, were tested yielding a modulus value of approximately 560 GPa or 81 MSI. This demonstrated that a high modulus graphitic carbon fiber is certainly possible from the ACP 20 mesophase pitch. For future work, a better balance between the softening point temperature, the spinning temperature, and filtering must be met to reduce the volatiles generated in the pitch during spinning. This would reduce voids in the fiber, facilitate spinning, and generate finer, higher performance graphitic fiber.

36 MATERIALS SCIENCE↗