Search NASA⌕ Search

SEARCH · Search NASA

Results for “field protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Sci—Fri PM: Topics — 08: The Role and Benefits of Electromagnetic Needle-Tracking Technologies in Brachytherapy

In modern brachytherapy, application of large doses of ionizing radiation in a limited number of fractions is frequent. Furthermore, as with any surgical procedures, brachytherapy is subject to learning curve effects. In this context, there could be advantages of integrating real-time tracking of needles/catheters to existing protocols given the recent prominent advances in tracking technologies. In this work, we review the use of an electromagnetic tracking system (EMTS) based on the second generation Aurora® Planar Field Generator (Northern Digital Inc) and custom design needles (Philips Healthcare) for brachytherapy applications. The position and orientation information is obtained from 5 degrees of freedom sensors. Basic system performance characterization is performed in well-controlled conditions to establish accuracy and reproducibility as well as potential interference from standard brachytherapy equipment. The results show that sensor locations can be tracked to within 0.04mm (la) when located within 26cm of the generator. Orientation accuracy of the needle remained within ±1° in the same region, but rose quickly at larger distances. The errors on position and orientation strongly dependent the sensor position in the characterization volume (500×500×500mm{sup 3}). The presence of an ultrasound probe was shown to have negligible effects on tracking accuracy. The use of EMTS for automatic catheter/applicator reconstruction was also explored. Reconstruction time was less than 10 sec/channel and tips identification was within 0.69±0.29mm of the reference values. Finally, we demonstrate that hollow needle designs with special EM adaptation also allow for real-time seed drop position estimation. In phantom experiments showed that drop positions were on average within 1.6±0.9mm of the reference position measured from μCT. Altogether, EMTS offer promising benefits in a wide range of brachytherapy applications.

60 APPLIED LIFE SCIENCES↗

Mapping Environmental Contaminants at Ray Mine, AZ

Airborne Visible and InfraRed Imaging Spectrometer (AVIRIS) data was collected over Ray Mine as part of a demonstration project for the Environmental Protection Agency (EPA) through the Advanced Measurement Initiative (AMI). The overall goal of AMI is to accelerate adoption and application of advanced measurement technologies for cost effective environmental monitoring. The site was selected to demonstrate the benefit to EPA in using advanced remote sensing technologies for the detection of environmental contaminants due to the mineral extraction industry. The role of the Jet Propulsion Laboratory in this pilot study is to provide data as well as performing calibration, data analysis, and validation of the AVIRIS results. EPA is also interested in developing protocols that use commercial software to perform such work on other high priority EPA sites. Reflectance retrieval was performed using outputs generated by the MODTRAN radiative transfer model and field spectra collected for the purpose of calibration. We are presenting advanced applications of the ENVI software package using n-Dimensional Partial Unmixing to identify image-derived endmembers that best match target materials reference spectra from multiple spectral libraries. Upon identification of the image endmembers the Mixture Tuned Match Filter algorithm was applied to map the endmembers within each scene. Using this technique it was possible to map four different mineral classes that are associated with mine generated acid waste.

McCubbin, Ian↗

Development of a Web-Based Visualization Platform for Climate Research Using Google Earth

Recently, it has become easier to access climate data from satellites, ground measurements, and models from various data centers, However, searching. accessing, and prc(essing heterogeneous data from different sources are very tim -consuming tasks. There is lack of a comprehensive visual platform to acquire distributed and heterogeneous scientific data and to render processed images from a single accessing point for climate studies. This paper. documents the design and implementation of a Web-based visual, interoperable, and scalable platform that is able to access climatological fields from models, satellites, and ground stations from a number of data sources using Google Earth (GE) as a common graphical interface. The development is based on the TCP/IP protocol and various data sharing open sources, such as OPeNDAP, GDS, Web Processing Service (WPS), and Web Mapping Service (WMS). The visualization capability of integrating various measurements into cE extends dramatically the awareness and visibility of scientific results. Using embedded geographic information in the GE, the designed system improves our understanding of the relationships of different elements in a four dimensional domain. The system enables easy and convenient synergistic research on a virtual platform for professionals and the general public, gr$tly advancing global data sharing and scientific research collaboration.

Sun, Xiaojuan↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called WiSe Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring

Wireless Sensor Network↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called Wi-Se Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring.

Wireless Sensor Network↗

Open-source Wireless Sensor Network (Wi-Se Net) for Flexible Deployment

Wireless sensors, especially if battery powered, have a number of advantages over wired sensors for flexible or temporary diagnostic deployment in a field or lab setting. Recent advances in wireless technology and microprocessor boards have produced a variety of inexpensive off-the shelf chips which can communicate wirelessly with simple protocols. This paper describes the design and implementation of a highly customizable wireless sensor network (called WiSe Net) using inexpensive open-source hardware components as wireless nodes. These wireless sensor nodes can transmit data at a rate <250 Hz, can be battery powered, and have a small footprint (2x5 cm). In addition, a preliminary over-the-air programming system was developed to allow for simple wireless configuration when active. The network performance was demonstrated by taking distributed and electrically isolated temperature measurements on a high-voltage lab apparatus. Although this test case is in a laboratory setting, this network architecture could be easily repurposed for various other forms of monitoring.

Wireless Sensor Network↗

Siemens Multileaf Collimator Characterization and Quality Assurance Approaches for Intensity-Modulated Radiotherapy

Application of the multileaf collimator (MLC) has evolved from replacing blocks to create treatment fields to creating photon fluence modulation for intensity-modulated radiotherapy (IMRT). Multileaf collimator system performance requirements are far more stringent for such applications and will require increased performance for future applications, such as motion tracking. This article reviews Siemens MLC systems, including a technical description and dosimetric characteristics of 56-, 82-, and 160-leaf designs. Routine quality assurance of MLC for IMRT necessitates frequent and critical assessment of MLC leaf position calibration errors that can present in many different ways (e.g., accuracy, reproducibility, longevity, hysteresis, and collimator/gantry angle dependencies). Several techniques for measuring these errors are presented, along with qualitative and quantitative techniques for analyzing results. In particular, increased accuracy of leaf position measurement at variable gantry angles is enabled by spatial transformations to electronic portal imaging device position quantified by calibration protocols introduced with megavoltage cone beam. Measured values of X-ray transmission (intra-leaf, inter-leaf, and through abutting leaf pairs) and penumbra (leaf end, leaf tongue, leaf groove) are presented with an evaluation of their characterization by a treatment-planning system. The dosimetric impact of planning system model inadequacies is demonstrated for collimator scatter, dose profile values within 30 mm of the field edge, and the resultant effect demonstrated on clinical cases. Finally, a description of automated quality assurance delivery, analysis, and calibration protocols applicable for the specific vendor's system is provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗

Medical Response, Search and Recovery during the Space Shuttle Columbia Accident Investigation

On February 1, 2003, the Space Shuttle Columbia broke apart during atmospheric re-entry on mission STS-107. After an event such as this, with high visibility and international interest, the operational challenge of recovering the crewmembers could not be underestimated. The Space Shuttle Program is organized to respond to a vehicle mishap using the resources of the Mishap Investigation Team (MIT). On the afternoon of Feb. 1, 2003, the MIT deployed to Barksdale Air Force Base (AFB), Louisiana. This location became the investigative center and interim storage location for crewmembers received from the Lufkin, Texas Disaster Field Office (DFO). The Lufkin DFO served as the primary area for all operations, including staging assets and deploying field teams for search, recovery and security of crewmember remains. More than 2,000 people from numerous organizations were involved with the recovery of the crew. All seven crewmembers of STS-107 were recovered and ceremonial last rights were administered. Astronaut and military personnel escorted the crew with honor to the MIT at Barksdale AFB, Louisiana. At Barksdale AFB a temporary morgue was established in an aircraft hangar and operated for approximately two weeks during which time coordination with the DFO field recovery teams, Armed Forces Institute of Pathology (AFIP) medical personnel, and the crew surgeons was on going. Families of crewmembers and NASA management were notified daily of the current findings. Working under the leadership of the MIT Lead, the medical team developed and executed a short-term plan to identify and relocate the crew with a military honor guard and protocol to the medical examiner at the Armed Forces Port Mortuary, Dover AFB, Delaware. After operations at Barksdale AFB were concluded the medical team transitioned back to Houston and a long-term plan was developed and implemented which involved the Air Force Mortuary Affairs at Randolph AFB, Texas. This plan was coordinated with search teams in the field, Barksdale AFB Mortuary Affairs, KSC security, AFIP, and the crew surgeons at JSC.

Stepaniak, Philip C.↗

Coherent transfer by adiabatic passage in two-dimensional lattices

Coherent tunneling by adiabatic passage (CTAP) is a well-established technique for robust spatial transport of quantum particles in linear chains. Here we introduce two exactly-solvable models where the CTAP protocol can be extended to two-dimensional lattice geometries. Such bi-dimensional lattice models are synthesized from time-dependent second-quantization Hamiltonians, in which the bosonic field operators evolve adiabatically like in an ordinary three-level CTAP scheme thus ensuring adiabatic passage in Fock space. - Highlights: • New ways of coherent transport by adiabatic passage (CTAP) in 2D lattices. • Synthesis of exactly-solvable 2D lattices from a simple three-well model. • CTAP in 2D lattices can be exploited for quantum state transfer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling inclusive electron-nucleus scattering with Bayesian artificial neural networks

We introduce a Bayesian protocol based on artificial neural networks that is suitable for modeling inclusive electron-nucleus scattering on a variety of nuclear targets with quantified uncertainties. Unlike previous applications in the field, which directly parameterize the cross sections, our approach employs artificial neural networks to represent the longitudinal and transverse response functions. In contrast to cross sections, which depend on the incoming energy, scattering angle, and energy transfer, the response functions are determined solely by the energy and momentum transfer to the system, allowing the angular component to be treated analytically. We assess the accuracy and predictive power of our framework against the extensive data in the quasielastic inclusive electron-scattering database. Additionally, we present novel extractions of the longitudinal and transverse response functions and compare them with previous experimental analysis and nuclear ab-initio calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying Antibiotic Distribution in Solid and Liquid Fractions of Manure Using a Two-Step, Multi-Residue Antibiotic Extraction

Antibiotic distribution and analysis within liquid and solid fractions of manure are highly variable due to each compound’s respective physiochemical properties. This study developed and evaluated a uniform method extracting 10 antibiotics from 4 antibiotic classes (tetracycline, sulfonamides, macrolides, and β-lactam) from unprocessed manure, solid–liquid separated manure, and composted solids. Through systematic manipulation of previously published liquid chromatography tandem mass spectrometry methods; this study developed an extraction protocol with optimized recovery efficiencies for varied manure substrates. The method includes a two-step, liquid-solid extraction using 10 mL of 0.1 M EDTA-McIlviane buffer followed by 10 mL of methanol. Antibiotics recoveries from unprocessed manure, separated liquids, separated solids, and heat-treated solids using the two-step extraction method had relative standard deviations < 30% for all but ceftiofur. Total antibiotic recoveries were 67–131% for tetracyclines, 56% for sulfonamide, 49–53% for macrolides, and 1.3–66% for β-lactams. This is the first study to use one protocol to assess four classes of antibiotics in liquid and solid manure fractions. This study allowed for more precise risk assessment of antibiotic transport in manure waste stream applied to fields as a liquid or solid compost.

59 BASIC BIOLOGICAL SCIENCES↗

Developing a Standard Method for Link-Layer Security of CCSDS Space Communications

Communications security for space systems has been a specialized field generally far removed from considerations of mission interoperability and cross-support in fact, these considerations often have been viewed as intrinsically opposed to security objectives. The space communications protocols defined by the Consultative Committee for Space Data Systems (CCSDS) have a twenty-five year history of successful use in over 400 missions. While the CCSDS Telemetry, Telecommand, and Advancing Orbiting Systems protocols for use at OSI Layer 2 are operationally mature, there has been no direct support within these protocols for communications security techniques. Link-layer communications security has been successfully implemented in the past using mission-unique methods, but never before with an objective of facilitating cross-support and interoperability. This paper discusses the design of a standard method for cryptographic authentication, encryption, and replay protection at the data link layer that can be integrated into existing CCSDS protocols without disruption to legacy communications services. Integrating cryptographic operations into existing data structures and processing sequences requires a careful assessment of the potential impediments within spacecraft, ground stations, and operations centers. The objective of this work is to provide a sound method for cryptographic encapsulation of frame data that also facilitates Layer 2 virtual channel switching, such that a mission may procure data transport services as needed without involving third parties in the cryptographic processing, or split independent data streams for separate cryptographic processing.

Biggerstaff, Craig↗

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC↗

Quantum Enhanced Cavity QED Interferometer with Partially Delocalized Atoms in Lattices

Herein, we propose a quantum enhanced interferometric protocol for gravimetry and force sensing using cold atoms in an optical lattice supported by a standing-wave cavity. By loading the atoms in partially delocalized Wannier-Stark states, it is possible to cancel the undesirable inhomogeneities arising from the mismatch between the lattice and cavity fields and to generate spin squeezed states via a uniform one-axis twisting model. The quantum enhanced sensitivity of the states is combined with the subsequent application of a compound pulse sequence that allows us to separate atoms by several lattice sites. This, together with the capability to load small atomic clouds in the lattice at micrometric distances from a surface, make our setup ideal for sensing short-range forces. We show that for arrays of 10 4 atoms, our protocol can reduce the required averaging time by a factor of 10 compared to unentangled lattice-based interferometers after accounting for primary sources of decoherence.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low Cost Open-Path Instrument for Monitoring Atmospheric Carbon Dioxide at Sequestration Sites

In the past 48 months of the project, we have accomplished all objectives outlined in the proposal. In the first year, we demonstrated the technology for remote sensing on a bench top scale. The core electronics are designed and fabricated. We achieved results that will safely deliver the specifications outlined in the proposal. In the 2nd year, 2 major technical tasks outlined in the Statement of Objectives, i.e. Build a field test ready prototype of a long-range CO2 monitor, and characterize its performance in the short term and demonstrate that the monitor characteristics meet the goals set in the initial proposal, have been accomplished. We also conducted simulation work that defines the different deployment strategies for our sensors at sequestration sites. In the 3rd year, Specifications and Testing protocols have been developed for the CO2 monitor. 1% accuracy had been demonstrated in short period tests ({approx}1 hour). Unattended system operation and stability over a period of a week has been demonstrated with and without EDFA (laser power amplifier). The sensitivity of the instrument to CO2 leaks has been demonstrated. In the 4th no-cost extension year, we further field tested the system and the experience we accumulated give us a clear picture of what else are needed for final field deployment. These results have shown all the objectives of the project have been fulfilled. In July 2008, along with our commercial partner we won the DOE STTR phase I award to commercialize the instrument developed in this project - a testimony to the achievement of this research.

47 OTHER INSTRUMENTATION↗

The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors

We introduce a Xilinx RF System-on-Chip (RFSoC)-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short), which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC field-programmable gate array, custom firmware, and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average gate fidelity of ℱ avg =99.93%. All of the schematics, firmware, and software are open-source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward high-throughput defect density quantification: A comparison of techniques for irradiated samples

Transmission electron microscopy (TEM) is an established tool used for the investigation of defects in materials. Traditionally, diffraction contrast techniques—two-beam bright-field and weak-beam dark-field—have been used to image defects due to contrast sensitivity from weak lattice strains. Use of these methods entail an intricate tilt series of imaging using different diffracting vectors, g, to verify the g•b invisibility criterion relative to the different defect types and habit planes inherent to the material. Recently, the addition of down-zone imaging and STEM imaging has also proven to be effective imaging techniques for defect density analysis. Interest in nanocrystalline (NC) materials, spurred by their conjectured superior properties compared to their coarse-grain counterparts, has been thriving and the investigation of their defect morphologies is essential. Maneuvering within NC samples in the TEM adds another layer of difficulty making the aforementioned techniques not practical for application to specimens with complex microstructures. For this reason, we have devised a protocol for identifying NC grains optimally oriented for quantitative analysis using NanoMegas ASTAR automated crystal orientation mapping (ACOM) in the TEM. In this work, we conduct a series of experiments assessing the effectiveness of conventional two-beam bright-field, weak-beam dark-field, and down-zone STEM imaging. Here, we also evaluate an ACOM-assisted multibeam imaging method and compare defect density results obtained using each technique in an irradiated nanocrystalline Au sample.

36 MATERIALS SCIENCE↗