Search NASA⌕ Search

SEARCH · Search NASA

Results for “fractionalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Measurements of B{yields}({pi},{eta},{eta}{sup '})l{nu}{sub l} Branching Fractions and Determination of |V{sub ub}| with Semileptonically Tagged B Mesons

We report measurements of branching fractions for the decays B{yields}Pl{nu}{sub l}, where P are the pseudoscalar charmless mesons {pi}{sup -}, {pi}{sup 0}, {eta} and {eta}{sup '}, based on 348 fb{sup -1} of data collected with the BABAR detector, using B{sup 0} and B{sup +} mesons found in the recoil of a second B meson decaying as B{yields}D{sup (*)}l{nu}{sub l}. Assuming isospin symmetry, we combine pionic branching fractions to obtain B(B{sup 0}{yields}{pi}{sup -}l{sup +}{nu}{sub l})=(1.54{+-}0.17{sub (stat)}{+-}0.09{sub (syst)})x10{sup -=} 4; we find 3.2{sigma} evidence of the decay B{sup +}{yields}{eta}l{sup +}{nu}{sub l} and measure its branching fraction to be (0.64{+-}0.20{sub (stat)}{+-}0.03{sub (syst)})x10{sup -4}, and determine B(B{sup +}{yields}{eta}{sup '}l{sup +}{nu}{sub l})<0.47x10{sup -4} to 90% confidence level. Using partial branching fractions for the pionic decays in ranges of the momentum transfer and a variety of form factor calculation, we obtain values of the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element |V{sub ub}| in ranging from 3.6x10{sup -3} to 4.1x10{sup -3}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Ratio of the B 0 → D * – τ + ν τ and B 0 → D * – μ + ν μ Branching Fractions Using Three-Prong τ -Lepton Decays

The ratio of branching fractions R( D * – ) ≡ B( B 0 → D * – τ + ν τ )/B( B 0 → D * – μ + ν μ ) is measured using a data sample of proton-proton collisions collected with the LHCb detector at center-of-mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3 fb –1 . For the first time, R( D * – ) is determined using the τ-lepton decays with three charged pions in the final state. The B 0 → D * – τ + ν τ yield is normalized to that of the B 0 → D * – π + π – π + mode, providing a measurement of B( B 0 → D * – τ + ν τ )/B( B 0 → D * – π + π – π + ) = 1.97 ± 0.13 ± 0.18, where the first uncertainty is statistical and the second systematic. The value of B( B 0 → D * – τ + ν τ )=(1.42 ± 0.094 ± 0.129 ± 0.054)% is obtained, where the third uncertainty is due to the limited knowledge of the branching fraction of the normalization mode. Using the well-measured branching fraction of the B 0 → D * – μ + ν μ decay, a value of R( D * – ) = 0.291 ± 0.019 ± 0.026 ± 0.013 is established, where the third uncertainty is due to the limited knowledge of the branching fractions of the normalization and B 0 → D * – μ + ν μ modes. This measurement is in agreement with the standard model prediction and with previous results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kohn-Sham Theory of the Fractional Quantum Hall Effect

We formulate the Kohn-Sham (KS) equations for the fractional quantum Hall effect by mapping the original electron problem into an auxiliary problem of composite fermions that experience a density dependent effective magnetic field. Self-consistent solutions of the KS equations demonstrate that our formulation captures not only configurations with nonuniform densities but also topological properties such as fractional charge and fractional braid statistics for the quasiparticles excitations. Lastly, this method should enable a realistic modeling of the edge structure, the effect of disorder, spin physics, screening, and of fractional quantum Hall effect in mesoscopic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy Gap of the Even-Denominator Fractional Quantum Hall State in Bilayer Graphene

Bernal bilayer graphene hosts even-denominator fractional quantum Hall states thought to be described by a Pfaffian wave function with non-Abelian quasiparticle excitations. Here, in this study, we report the quantitative determination of fractional quantum Hall energy gaps in bilayer graphene using both thermally activated transport and by direct measurement of the chemical potential. We find a transport activation gap of 5.1 K at B = 12 T for a half filled N = 1 Landau level, consistent with density matrix renormalization group calculations for the Pfaffian state. However, the measured thermodynamic gap of 11.6 K is smaller than theoretical expectations for the clean limit by approximately a factor of 2. We analyze the chemical potential data near fractional filling within a simplified model of a Wigner crystal of fractional quasiparticles with long-wavelength disorder, explaining this discrepancy. Our results quantitatively establish bilayer graphene as a robust platform for probing the non-Abelian anyons expected to arise as the elementary excitations of the even-denominator state.

36 MATERIALS SCIENCE↗

Chern Insulators at Integer and Fractional Filling in Moiré Pentalayer Graphene

The advent of moiré platforms for engineered quantum matter has led to discoveries of integer and fractional quantum anomalous Hall effects, with predictions for correlation-driven topological states based on electron crystallization. Here, we report an array of trivial and topological insulators formed in a moiré lattice of rhomobohedral pentalayer graphene (R5G). At a doping of one electron per moiré unit cell ( ν = 1 ), we see a correlated insulator with a Chern number that can be tuned between C = 0 and + 1 by an electric displacement field. This is accompanied by a series of additional Chern insulators with C = + 1 originating from fractional fillings of the moiré lattice— ν = 1 / 4 , 1 / 3 , and 2 / 3 —associated with the formation of moiré-driven topological electronic crystals. At ν = 2 / 3 the system exhibits an integer quantum anomalous Hall effect at zero magnetic field, but further develops hints of an incipient C = 2 / 3 fractional Chern insulator in a modest field. Our results establish moiré R5G as a fertile platform for studying the competition and potential intertwining of integer and fractional Chern insulators. Published by the American Physical Society 2025

Waters, Dacen (ORCID:0000000335880039)↗

Climate, soil mineralogy and mycorrhizal fungi influence soil organic matter fractions in eastern US temperate forests

Identifying the primary controls of particulate (POM) and mineral-associated organic matter (MAOM) content in soils is critical for determining future stocks of soil carbon (C) and nitrogen (N) across the globe. However, drivers of these soil organic matter fractions are likely to vary among ecosystems in response to climate, soil type and the composition of local biological communities. We tested how soil factors, climate and plant–fungal associations influenced the distribution and concentrations of C and N in MAOM and POM in seven temperate forests in the National Ecological Observatory Network (NEON) across the eastern United States. Samples of upper mineral horizon soil within each forest were collected in plots representing a gradient of dominant tree–mycorrhizal association, allowing us to test how plant and microbial communities influenced POM and MAOM across sites differing in climate and soil conditions. We found that concentrations of C and N in soil organic matter were primarily driven by soil mineralogy, but the relative abundance of MAOM versus POM C was strongly linked to plot-level mycorrhizal dominance. Furthermore, the effect of dominant tree mycorrhizal type on the distribution of N among POM and MAOM fractions was sensitive to local climate: in cooler sites, an increasing proportion of ectomycorrhizal-associated trees was associated with lower proportions of N in MAOM, but in warmer sites, we found the reverse. As an indicator of soil carbon age, we measured radiocarbon in the MAOM fraction but found that within and across sites, Δ 14 C was unrelated to mycorrhizal dominance, climate, or soil factors, suggesting that additional site-specific factors may be primary determinants of long-term SOM persistence. Our results indicate that while soil mineralogy primarily controls SOM C and N concentrations, the distribution of SOM among density fractions depends on the composition of vegetation and microbial communities, with these effects varying across sites with distinct climates. Here we also suggest that within biomes, the age of mineral-associated soil carbon is not clearly linked to the factors that control concentrations of MAOM C and N.

54 ENVIRONMENTAL SCIENCES↗

Pancreas volume and fat fraction in children with Type 1 diabetes

Abstract Aims People with Type 1 diabetes have smaller pancreases than healthy individuals. Several diseases causing pancreatic atrophy are associated with pancreatic steatosis, but pancreatic fat in Type 1 diabetes has not been measured. This cross‐sectional study aimed to compare pancreas size and fat fraction in children with Type 1 diabetes and controls. Methods The volume and fat fraction of the pancreases of 22 children with Type 1 diabetes and 29 controls were determined using magnetic resonance imaging. Results Pancreas volume was 27% smaller in children with diabetes (median 34.9 cm 3 ) than in controls (47.8 cm 3 ; P < 0.001). Pancreas volume correlated positively with age in controls ( P = 0.033), but not in children with diabetes ( P = 0.649). Pancreas volume did not correlate with diabetes duration, but it did correlate positively with units of insulin/kg body weight/day ( P = 0.048). A linear model of pancreas volume as influenced by age, body surface area and insulin units/kg body weight/day found that insulin dosage correlated with pancreas volume after controlling for both age and body surface area ( P = 0.009). Pancreatic fat fraction was not significantly different between the two groups (1.34% vs. 1.57%; P = 0.891). Conclusions Our findings do not indicate that pancreatic atrophy in Type 1 diabetes is associated with an increased pancreatic fat fraction, unlike some other diseases featuring reduced pancreatic volume. We speculate that our results may support the hypotheses that much of pancreatic atrophy in Type 1 diabetes occurs before the clinical onset of the disease and that exogenous insulin administration decelerates pancreatic atrophy after diabetes onset.

Regnell, S. E.↗

Determination of volume fractions in two-phase flows from sound speed measurement

Accurate measurement of the composition of oil-water emulsions within the process environment is a challenging problem in the oil industry. Ultrasonic techniques are promising because they are non-invasive and can penetrate optically opaque mixtures. This paper presents a method of determining the volume fractions of two immiscible fluids in a homogenized two-phase flow by measuring the speed of sound through the composite fluid along with the instantaneous temperature. Two separate algorithms are developed by representing the composite density as (i) a linear combination of the two densities, and (ii) a non-linear fractional formulation. Both methods lead to a quadratic equation with temperature dependent coefficients, the root of which yields the volume fraction. The densities and sound speeds are calibrated at various temperatures for each fluid component, and the fitted polynomial is used in the final algorithm. We present results when the new algorithm is applied to mixtures of crude oil and process water from two different oil fields, and a comparison of our results with a Coriolis meter; the difference between mean values is less than 1%. Analytical and numerical studies of sensitivity of the calculated volume fraction to temperature changes and calibration errors are also presented.

02 PETROLEUM↗

TH-A-BRF-04: Intra-Fraction Motion Characterization for Early Stage Rectal Cancer Using Cine-MRI

Purpose: To investigate the intra-fraction motion in patients with early stage rectal cancer using cine-MRI. Methods: Sixteen patient diagnosed with early stage rectal cancer underwent 1.5 T MR imaging prior to each treatment fraction of their short course radiotherapy (n=76). During each scan session, three 2D sagittal cine-MRIs were performed: at the beginning (Start), after 9:30 minutes (Mid), and after 18 minutes (End). Each cine-MRI has a duration of one minute at 2Hz temporal resolution, resulting in a total of 3:48 hours of cine-MRI. Additionally, standard T2-weighted (T2w) imaging was performed. Clinical target volume (CTV) an tumor (GTV) were delineated on the T2w scan and transferred to the first time-point of each cine-MRI scan. Within each cine-MRI, the first frame was registered to the remaining frames of the scan, using a non-rigid B-spline registration. To investigate potential drifts, a similar registration was performed between the first frame of the Start and End scans.To evaluate the motion, the distances by which the edge pixels of the delineations move in anterior-posterior (AP) and cranial-caudal (CC) direction, were determined using the deformation field of the registrations. The distance which incorporated 95% of these edge pixels (dist95%) was determined within each cine-MRI, and between Start- End scans, respectively. Results: Within a cine-MRI, we observed an average dist95% for the CTV of 1.3mm/1.5mm (SD=0.7mm/0.6mm) and for the GTV of 1.2mm/1.5mm (SD=0.8mm/0.9mm), in respectively AP/CC. For the CTV motion between the Start and End scan, an average dist95% of 5.5mm/5.3mm (SD=3.1mm/2.5mm) was found, in respectively AP/CC. For the GTV motion, an average dist95% of 3.6mm/3.9mm (SD=2.2mm/2.5mm) was found in AP/CC, respectively. Conclusion: Although intra-fraction motion within a one minute cine-MRI is limited, substantial intra-fraction motion was observed within the 18 minute time period between the Start and End cine-MRI.

60 APPLIED LIFE SCIENCES↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-01: Inference of Prostate PTV Margins in VMAT Delivery From Intra-Fraction Prostate Motion During SBRT Delivery

Purpose: To retrospectively quantify the intra-fraction prostate motion during stereotactic body radiation therapy (SBRT) treatment using CyberKnife’s target tracking system, which may provide insight into expansion margins from GTV to PTV used in gantry-based treatments. CyberKnife is equipped with an active tracking system (InTempo) that tracks the four fiducials placed in the prostate gland. The system acquires intra-fraction orthogonal kV images at 45° and 315° in a sequential fashion. Methods: A total of 38 patients treated with SBRT using CyberKnife between 2011 and 2013 were studied. Dose-regime was 36.25 Gy in 5 fractions (7.25 Gy/fraction, twice per week) as per RTOG 0938 guidelines. The CyberKnife image tracking logs for all SBRT treatments using InTempo were examined. A total of 13663 images were examined for the superior/inferior (SI), anterior/posterior (AP) and left/right (LR) translation as well as roll, pitch and yaw rotations for the target position relative to the last known model position. Results: The mean ± 2 SD of intra-fraction motion was contained within 3 mm for SI and LR and 4.5 mm for AP directions at 5 minutes into the treatment delivery. It was contained within 4 mm for SI and LR and 5 mm for AP at 10 minutes. At 15 minutes into delivery, all translations were contained within 5 mm. The mean ± 2 SD of prostate roll, pitch and yaw increased with time but were contained within 5 degree at 5, 10 and 15 minutes into treatment. Additionally, target translations and rotations were within ± 1 mm and ± 1 degree for 90% and 78% of the time. Conclusion: The organ motion component of PTV margin for 10 minute VMAT delivery is contained within 4 mm in SI and LR direction and within 5 mm in the AP direction.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-02: A New Intra-Fractional Prostate Motion Tracking Method in Volumetric Modulated Arc Therapy (VMAT) Via 2D/3D Registration

Purpose: Intra-fractional prostate motion leads uncertainty on delivered dose in radiotherapy and may cause significant dose deviation from the planned dose distribution. This is especially a concern in scenarios with a high dose per fraction and hence a long delivery time, e.g. stereotactic body radiotherapy. Knowledge about intra-fractional prostate motion is valuable to address this problem, e.g. by reconstructing delivered dose and performing adaptation. This study proposes a new approach to determine intra-fractional prostate motion in VMAT via 2D/3D maker registration. Methods: At our institution, each patient has three markers implanted in the prostate. During treatment delivery, kV triggered images were taken every three seconds to acquire 2D projection of 3D anatomy at the direction orthogonal to the therapeutic beam. Projected marker locations were identified on each projection image using template matching with geometric constraints. 3D prostate translation and rotation for each triggered image were obtained by solving an optimization problem, such that the calculated marker locations match the measured ones. Inter-image motion smoothness was employed as a constraint. We tested this method in simulation studies with five realistic prostate motion trajectories acquired via Calypso and in real phantom experiments. Results: For the simulation case, the motion range for these patients was 0.5∼6.0 mm. Root mean square (RMS) error of calculated motion along left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) directions were 0.26mm, 0.36mm, and 0.016mm, respectively. The motion range in the phantom study along LR, AP, and CC directions were 15mm, 20mm and 10mm. The mean RMS errors along these directions were 1.99mm, 1.37mm and 0.22mm. Conclusion: A new prostate motion tracking algorithm based on kV triggered images has been developed and validated. Clinically acceptable accuracy has been achieved.

60 APPLIED LIFE SCIENCES↗

Measurement of the branching fraction of the ${{B} ^0} {\rightarrow }{{D} ^+_{s}} {{\pi } ^-} $ decay

A branching fraction measurement of the \({{B} ^0} {\rightarrow }{{D} ^+_{s}} {{\pi } ^-} \) decay is presented using proton–proton collision data collected with the LHCb experiment, corresponding to an integrated luminosity of \(5.0\,\text {fb} ^{-1} \) . The branching fraction is found to be \({\mathcal {B}} ({{B} ^0} {\rightarrow }{{D} ^+_{s}} {{\pi } ^-} ) =(19.4 \pm \) \(1.8\pm 1.3 \pm 1.2)\times 10^{-6}\) , where the first uncertainty is statistical, the second systematic and the third is due to the uncertainty on the \({{B} ^0} {\rightarrow }{{D} ^-} {{\pi } ^+} \) , \({{D} ^+_{s}} {\rightarrow }{{K} ^+} {{K} ^-} {{\pi } ^+} \) and \({{D} ^-} {\rightarrow }{{K} ^+} {{\pi } ^-} {{\pi } ^-} \) branching fractions. This is the most precise single measurement of this quantity to date. As this decay proceeds through a single amplitude involving a \(b{\rightarrow }u\) charged-current transition, the result provides information on non-factorisable strong interaction effects and the magnitude of the Cabibbo–Kobayashi–Maskawa matrix element \(V_{ub}\) . Additionally, the collision energy dependence of the hadronisation-fraction ratio \(f_s/f_d\) is measured through \({{\overline{B}} {}^0_{s}} {\rightarrow }{{D} ^+_{s}} {{\pi } ^-} \) and \({{B} ^0} {\rightarrow }{{D} ^-} {{\pi } ^+} \) decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Bimodal Diagnostic Cloud Fraction Parameterization. Part I: Motivating Analysis and Scheme Description

Cloud fraction parameterizations are beneficial to regional, convection-permitting numerical weather prediction. For its operational regional midlatitude forecasts, the Met Office uses a diagnostic cloud fraction scheme that relies on a unimodal, symmetric subgrid saturation-departure distribution. This scheme has been shown before to underestimate cloud cover and hence an empirically based bias correction is used operationally to improve performance. This first of a series of two papers proposes a new diagnostic cloud scheme as a more physically based alternative to the operational bias correction. The new cloud scheme identifies entrainment zones associated with strong temperature inversions. Additionally, for model grid boxes located in this entrainment zone, collocated moist and dry Gaussian modes are used to represent the subgrid conditions. The mean and width of the Gaussian modes, inferred from the turbulent characteristics, are then used to diagnose cloud water content and cloud fraction. It is shown that the new scheme diagnoses enhanced cloud cover for a given gridbox mean humidity, similar to the current operational approach. It does so, however, in a physically meaningful way. Using observed aircraft data and ground-based retrievals over the southern Great Plains in the United States, it is shown that the new scheme improves the relation between cloud fraction, relative humidity, and liquid water content. An emergent property of the scheme is its ability to infer skewed and bimodal distributions from the large-scale state that qualitatively compare well against observations. A detailed evaluation and resolution sensitivity study will follow in Part II.

54 ENVIRONMENTAL SCIENCES↗

Fractionated Radiation Exposure of Rat Spinal Cords Leads to Latent Neuro-Inflammation in Brain, Cognitive Deficits, and Alterations in Apurinic Endonuclease 1

Ionizing radiation causes degeneration of myelin, the insulating sheaths of neuronal axons, leading to neurological impairment. As radiation research on the central nervous system has predominantly focused on neurons, with few studies addressing the role of glial cells, we have focused our present research on identifying the latent effects of single/ fractionated -low dose of low/ high energy radiation on the role of base excision repair protein Apurinic Endonuclease-1, in the rat spinal cords oligodendrocyte progenitor cells ’ differentiation. Apurinic endonuclease-1 is predominantly upregulated in response to oxidative stress by low- energy radiation, and previous studies show significant induction of Apurinic Endonucle- ase-1 in neurons and astrocytes. Our studies show for the first time, that fractionation of pro- tons cause latent damage to spinal cord architecture while fractionation of HZE ( 28 Si) induce increase in APE1 with single dose, which then decreased with fractionation. In conclusion, the oligoden- drocyte progenitor cells differentiation was skewed with increase in immature oligodendro- cytes and astrocytes, which likely cause the observed decrease in white matter, increased neuro-inflammation, together leading to the observed significant cognitive defects

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Experimental Studies and Model Analysis of Noble Gas Fractionation in Porous Media

Core Ideas Ambient noble gases in porous media fractionate from through‐flow of other gases. CO 2 fluxes and noble‐gas fractionation are measured in simple sandbox experiments. Modeled fractionation provides indirect proxy, e.g., of steady CO 2 leakage fluxes. The noble gases, which are chemically inert under normal terrestrial conditions but vary systematically across a wide range of atomic mass and diffusivity, offer a multicomponent approach to investigating gas dynamics in unsaturated soil horizons, including transfer of gas between saturated zones, unsaturated zones, and the atmosphere. To evaluate the degree to which fractionation of noble gases in the presence of an advective–diffusive flux agrees with existing theory, a simple laboratory sand column experiment was conducted. Pure CO 2 was injected at the base of the column, providing a series of constant CO 2 fluxes through the column. At five fixed sampling depths within the system, samples were collected for CO 2 and noble gas analyses, and ambient pressures were measured. Both the advection–diffusion and dusty gas models were used to simulate the behavior of CO 2 and noble gases under the experimental conditions, and the simulations were compared with the measured depth‐dependent concentration profiles of the gases. Given the relatively high permeability of the sand column (5 × 10 −11 m 2 ), Knudsen diffusion terms were small, and both the dusty gas model and the advection–diffusion model accurately predicted the concentration profiles of the CO 2 and atmospheric noble gases across a range of CO 2 flux from ∼700 to 10,000 g m −2 d −1 . The agreement between predicted and measured gas concentrations demonstrated that, when applied to natural systems, the multi‐component capability provided by the noble gases can be exploited to constrain component and total gas fluxes of non‐conserved (CO 2 ) and conserved (noble gas) species or attributes of the soil column relevant to gas transport, such as porosity, tortuosity, and gas saturation.

54 ENVIRONMENTAL SCIENCES↗

Iron isotope fractionation between solid and liquid metal in the Fe-P±Ni system: Experimental constraints and implications for meteorites

Iron meteorites record a range of Fe isotope compositions that hold valuable information regarding the evolution of their parent bodies. Interpreting this isotopic variability, however, requires experimental constraints on the equilibrium isotope fractionation between phases. It is thought that the cores of many iron meteorite parent bodies experienced fractional crystallization, during which crystallization of solid iron-nickel occurs from an increasingly non-metal-rich liquid alloy. Phosphorus is one component of this alloy, and this study provides the first constraints on Fe-isotope fractionation between solid and liquid alloys in the Fe-Ni-P system. Experiments comprising Fe and P show a clear enrichment in the light isotopes of Fe in the liquid phase, which increases with the amount of phosphorus. Nickel-bearing samples are offset from the trend defined by Ni-free experiments, which is accounted for by the change in the solid alloy phase from a body-centered cubic to face-centered cubic structure upon the addition of Ni. The increasing light isotope enrichment of the liquid with increasing P content suggests interstitial solution of P, which is known to lengthen Fe-Fe bonds in Fe-P liquids (Waseda and Shiraishi 1977). Results suggest a negligible effect of P on Fe isotope fractionation during planetesimal core crystallization. Iron isotopes may, however, prove useful for identifying the petrogenesis of schreibersite in pallasites and iron meteorites.

58 GEOSCIENCES↗

Limiting noise fraction in PDV measurements

The limiting frequency resolution of a PDV measurement is: σf = $\sqrt\frac{6 η}{fsτ^3π}$ where f s is the sample rate, τ is the analysis time duration, and 11 is the noise fraction. Although T is a strong lever for reducing uncertainty, this parameter must be kept small to preserve time resolution. Consider a PDV measurement with sampled at 80 GS/s and analyzed in 1 ns durations. A 1% noise fraction corresponds to 0.87 MHz of frequency uncertainty, which at 1550 nm works out to 0.68 m/s. A 10% noise fraction has a limiting velocity resolution of about 7 m/s; for comparison, a VISAR system with similar response time (0.5 ns delay, 532 m/s fringe constant) would have a limiting uncertainty of 5-6 m/s. Noise fractions of 10-20% or less are desirable for measurements at this time scale.

42 ENGINEERING↗