Search NASA⌕ Search

SEARCH · Search NASA

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Simulation of the Effects of Hard Limiting on Image Quality of Synthetic Aperture Radar

Starting with a magnetic tape of a scene viewed by the Landsat satellite, the radar return of reflectors whose average intensity matched that of the picture elements in the scene has been simulated. The returns were processed in three ways: normally or with no quantization, with a procedure simulation IF hard limiting, and with a procedure simulating video (baseband) hard limiting. For each type of processing an image for a one, two, and four-look system has been developed. It was found that IF limiting is slightly better than video limiting, while both can be reasonable trade-offs of image quality for reduced data rates when the number of looks is four or less. These conclusions are supported by photographs representing the different processing techniques.

Lipes, R. G.↗

Cone Beam Computed Tomography: The Challenges and Strategies in Its Application for Dose Accumulation

Online image guidance using cone beam computed tomography (CBCT) has greatly improved the geometric precision of radiotherapy. Changes in anatomy are common during a course of fractionated treatment, resulting in dose deviation from the planned distribution. There is increased interest in performing dose accumulation to compute the actual delivered dose and to adapt the treatment when necessary. This can be achieved by delineating the volume of interest and by generating “dose of the day” through dose computation on the CBCT. However, the image quality and the accuracy of the CT number of CBCT are deemed to be inferior to fan beam CT, which increases the uncertainty associated in this process. A review of literature was conducted to assess the reliability of and to examine strategies for overcoming the challenges in using CBCT for volume delineation and dose computation. The review demonstrates that the uncertainty varies across body sites, and different strategies have been recommended to generate comparable results to images from CT simulators. This facilitates a better understanding of the potential and the limitation of using CBCT for dose accumulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Flow Behavior Inside the Submerged Entry Nozzle

According to various authors, the surface quality of steel depends on the dynamic conditions that occur within the continuous casting mold’s upper region. The meniscus, found in that upper region, is where the solidification process begins. The liquid steel is distributed into the mold through a submerged entry nozzle (SEN). In this paper, the dynamic behavior inside the SEN is analyzed by means of physical experiments and numerical simulations. The particle imaging velocimetry technique was used to obtain the vector field in different planes and three-dimensional flow patterns inside the SEN volume. Moreover, large eddy simulation was performed, and the turbulence model results were used to understand the nonlinear flow pattern inside the SEN. Using scaled physical and numerical models, quasi-periodic behavior was observed due to the interaction of two three-dimensional vortices that move inside the SEN lower region located between the exit ports of the nozzle.

36 MATERIALS SCIENCE↗

Rain, fog, and clouds for aircraft simulators

Environmental chamber creates realistic fog and rain effects in aircraft simulator. It reproduces clouds, homogeneous fog, patches of fog, rain and fog, and rain only. It is used with real time digital computer, color computer generated image display that simulates airport lights, or color television camera that produces moving display of airport runway as depicted on model terrain board.

Chase, W. D.↗

NASA's GMAO Atmospheric Motion Vectors Simulator: Description and Application to the MISTiC Winds Concept

An atmospheric wind vectors (AMVs) simulator was developed by NASA's GMAO to simulate observations from future satellite constellation concepts. The synthetic AMVs can then be used in OSSEs to estimate and quantify the potential added value of new observations to the present Earth observing system and, ultimately, the expected impact on the current weather forecasting skill. The GMAO AMV simulator is a tunable and flexible computer code that is able to simulate AMVs expected to be derived from different instruments and satellite orbit configurations. As a case study and example of the usefulness of this tool, the GMAO AMV simulator was used to simulate AMVs envisioned to be provided by the MISTiC Winds, a NASA mission concept consisting of a constellation of satellites equipped with infrared spectral midwave spectrometers, expected to provide high spatial and temporal resolution temperature and humidity soundings of the troposphere that can be used to derive AMVs from the tracking of clouds and water vapor features. The GMAO AMV simulator identifies trackable clouds and water vapor features in the G5NR and employs a probabilistic function to draw a subset of the identified trackable features. Before the simulator is applied to the MISTiC Winds concept, the simulator was calibrated to yield realistic observations counts and spatial distributions and validated considering as a proxy instrument to the MISTiC Winds the Himawari-8 Advanced Imager (AHI). The simulated AHI AMVs showed a close match with the real AHI AMVs in terms of observation counts and spatial distributions, showing that the GMAO AMVs simulator synthesizes AMVs observations with enough quality and realism to produce a response from the DAS equivalent to the one produced with real observations. When applied to the MISTiC Winds scanning points, it can be expected that the MISTiC Winds will be able to collect approximately 60,000 wind observations every 6 hours, if considering a constellation composed of 12 satellites (4 orbital planes). In addition, one of the main expected impacts of the MISTiC Winds concept is the ability to derive water vapor feature tracking AMVs below 500-400 hPa, an unique feature among the water vapor AMVs derived from the current Earth observing system.

Carvalho, David↗

NASA's GMAO Atmospheric Motion Vectors Simulator: Description and Application to the MISTiC Winds Concept

An atmospheric wind vectors (AMVs) simulator was developed by NASA's GMAO to simulate observations from future satellite constellation concepts. The synthetic AMVs can then be used in OSSEs to estimate and quantify the potential added value of new observations to the present Earth observing system and, ultimately, the expected impact on the current weather forecasting skill. The GMAO AMV simulator is a tunable and flexible computer code that is able to simulate AMVs expected to be derived from different instruments and satellite orbit configurations. As a case study and example of the usefulness of this tool, the GMAO AMV simulator was used to simulate AMVs envisioned to be provided by the MISTiC Winds, a NASA mission concept consisting of a constellation of satellites equipped with infrared spectral midwave spectrometers, expected to provide high spatial and temporal resolution temperature and humidity soundings of the troposphere that can be used to derive AMVs from the tracking of clouds and water vapor features. The GMAO AMV simulator identifies trackable clouds and water vapor features in the G5NR and employs a probabilistic function to draw a subset of the identified trackable features. Before the simulator is applied to the MISTiC Winds concept, the simulator was calibrated to yield realistic observations counts and spatial distributions and validated considering as a proxy instrument to the MISTiC Winds the Himawari-8 Advanced Imager (AHI). The simulated AHI AMVs showed a close match with the real AHI AMVs in terms of observation counts and spatial distributions, showing that the GMAO AMVs simulator synthesizes AMVs observations with enough quality and realism to produce a response from the DAS equivalent to the one produced with real observations. When applied to the MISTiC Winds scanning points, it can be expected that the MISTiC Winds will be able to collect approximately 60,000 wind observations every 6 hours, if considering a constellation composed of 12 satellites (4 orbital planes). In addition, one of the main expected impacts of the MISTiC Winds concept is the ability to derive water vapor feature tracking AMVs below 500-400 hPa, an unique feature among the water vapor AMVs derived from the current Earth observing system.

Carvalho, David↗

Laboratory Scale Testing of Ignition Overpressure for Space Vehicle Launch Pad Environments

A scale model of a NASA representative space vehicle is used to develop a refined estimate of the transient pressure loads that are expected to form at the base of the vehicle in the event of a vapor cloud explosion. Flammable vapor clouds are known to form prior to engine startup due to the significant amount of unburned hydrogen that is ejected from the combustion chamber. In the event of a vapor cloud explosion, the vehicle and payload must be able to withstand the resulting overpressure waves. The study comprises an array of pressure sensors located along the base heat shield of the scale model space vehicle as well as the interior wall and throat plug plane of the solid rocket booster. A spark source generator is used to simulate the overpressure wave produced by a vapor cloud explosion while measurements are acquired with and without the effect of a mobile launcher. Time- resolved schlieren images of the simulated vapor cloud explosion reveal the path and impact of both the initial wave and several reflected waves on the various components at the base of the space vehicle. In some instances, the reflected waves superpose to create waves that are higher in amplitude than the initial overpressure wave. A time frequency analysis of the pressure waveforms measured inside the solid rocket booster reveal a ring down tone corresponding to a standing wave that is four times the length of the nozzle.

Tinney, Charles E.↗

A digital Seasat SAR correlation-simulation program

A correlation-simulation program for processing Seasat SAR data is presented, featuring the use of FORTRAN code to allow simple transference to another computer. The highest attainable azimuthal resolution for Seasat SAR experiments and the ability to generate images with varying quality by varying resolution or the number of looks are additional features. A fiber optics link transfers the Seasat data from high intensity digital tapes to an SEL 32/55 computer, and the least significant bits of the 5 bit data samples are truncated, thus the input data have 4 bits per sample. A total 8192 echoes are processed each time and stored on 8 separate data files on the disk. In addition, a program operating on 1-look high resolution images for performance simulations of proposed radar systems and processing schemes has been completed. Finally, the coding is simple, and 8 hours are required to process one image using this program.

Li, F.↗

Generating CAHV and CAHVOR Images with Shadows in ROAMS

Part of the Rover Analysis, Modeling and Simulation (ROAMS) software that synthesizes images of terrain has been augmented to make the images more realistic. [ROAMS was described in "Simulating Operation of a Planetary Rover" (NPO-30722), NASA Tech Briefs, Vol. 28, No. 9 (September 2004), page 52. ROAMS simulates the operation of a robotic vehicle (rover) exploring terrain on a remote planet.] The images are needed for modeling responses of rover cameras that provide sensory inputs for machine-vision-based algorithms for controlling the motion of the rover. The augmented image-synthesizing part of the ROAMS software supports terrain geometry and texture specifiable by the user, CAHV and CAHVOR camera models, and more-realistic shadowing (see figure). (The letters in "CAHV" represent vectors in a standard photogrammetric model of a pinhole camera. Letters O and R in "CAHVOR" represent vectors used to model distortions.) A contemplated future version of ROAMS would support the CAHVORE model, which represents more-general cameras, including those having fish-eye or other wide-field-of-view lenses. (Letter E in "CAHVORE" represents a vector used to model apparent motion of a camera entrance pupil.)

Madison, Richard↗

Energetic neutral atom image of a storm-time ring current

Energetic neutral atom (ENA) images of a storm-time ring current produced from direct measurements and model simulations are presented and analyzed. An ENA image of the storm-time ring current was obtained with the Medium Energy Particles Instrument (MEPI) mounted on ISEE 1 on September 29, 1978, and a zero-order model of the ring current ion was employed to simulate the ENA image. The simulated instrument response is compared with actual ENA measurements. It is observed that the spatial distribution of singly charged ions detected from the ENA images displays equatorial midnight/noon asymmetry in differential ion intensity with a midnight/noon ratio of greater than or equal to 20:1; peak ion fluxs, H(+) and O(+), in the midnight sector are greater than 10 to the 6th/(sq cm s sr keV); and ENA fluxes from the brighter areas of the image exceed greater than 1000/(sq cm s sr keV). It is noted that the ENA image from MEPI data correlates with the morphology of the simulated response of MEPI calculated from the model.

Roelof, Edmond C.↗

SU-F-T-403: Impact of Dose Reduction for Simulation CT On Radiation Therapy Treatment Planning

Purpose: To investigate the feasibility of applying ALARA principles to current treatment planning CT scans. The study aims to quantitatively verify lower dose scans does not alter treatment planning. Method: Gammex 467 tissue characterization phantom with inserts of 14 different materials was scanned at seven different mA levels (30∼300 mA). CT numbers of different inserts were measured. Auto contouring for bone and lung in treatment planning system (Pinnacle) was used to evaluate the effect of CT number accuracy from treatment planning aspect, on the 30 and 300 mA-scanned images. A head CT scan intended for a 3D whole brain radiation treatment was evaluated. Dose calculations were performed on normal scanned images using clinical protocol (120 kVP, Smart mA, maximum 291 mA), and the images with added simulating noise mimicking a 70 mA scan. Plan parameters including isocenter, beam arrangements, block shapes, dose grid size and resolution, and prescriptions were kept the same for these two plans. The calculated monitor units (MUs) for these two plans were compared. Results: No significant degradation of CT number accuracy was found at lower dose levels from both the phantom scans, and the patient images with added noise. The CT numbers kept consistent when mA is higher than 60 mA. The auto contoured volumes for lung and cortical bone show 0.3% and 0.12% of differences between 30 mA and 300 mA respectively. The two forward plans created on regular and low dose images gave the same calculated MU, and 98.3% of points having <1% of dose difference. Conclusion: Both phantom and patient studies quantitatively verified low dose CT provides similar quality for treatment planning at 20–25% of regular scan dose. Therefore, there is the potential to optimize simulation CT scan protocol to fulfil the ALARA principle and limit unnecessary radiation exposure to non-targeted tissues.

60 APPLIED LIFE SCIENCES↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

TH-CD-202-05: DECT Based Tissue Segmentation as Input to Monte Carlo Simulations for Proton Treatment Verification Using PET Imaging

Purpose: To improve agreement of predicted and measured positron emitter yields in patients, after proton irradiation for PET-based treatment verification, using a novel dual energy CT (DECT) tissue segmentation approach, overcoming known deficiencies from single energy CT (SECT). Methods: DECT head scans of 5 trauma patients were segmented and compared to existing decomposition methods with a first focus on the brain. For validation purposes, three brain equivalent solutions [water, white matter (WM) and grey matter (GM) – equivalent with respect to their reference carbon and oxygen contents and CT numbers at 90kVp and 150kVp] were prepared from water, ethanol, sucrose and salt. The activities of all brain solutions, measured during a PET scan after uniform proton irradiation, were compared to Monte Carlo simulations. Simulation inputs were various solution compositions obtained from different segmentation approaches from DECT, SECT scans, and known reference composition. Virtual GM solution salt concentration corrections were applied based on DECT measurements of solutions with varying salt concentration. Results: The novel tissue segmentation showed qualitative improvements in %C for patient brain scans (ground truth unavailable). The activity simulations based on reference solution compositions agree with the measurement within 3–5% (4–8Bq/ml). These reference simulations showed an absolute activity difference between WM (20%C) and GM (10%C) to H2O (0%C) of 43 Bq/ml and 22 Bq/ml, respectively. Activity differences between reference simulations and segmented ones varied from −6 to 1 Bq/ml for DECT and −79 to 8 Bq/ml for SECT. Conclusion: Compared to the conventionally used SECT segmentation, the DECT based segmentation indicates a qualitative and quantitative improvement. In controlled solutions, a MC input based on DECT segmentation leads to better agreement with the reference. Future work will address the anticipated improvement of quantification accuracy in patients, comparing different tissue decomposition methods with an MR brain segmentation. Acknowledgement: DFG-MAP and HIT-Heidelberg Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)

60 APPLIED LIFE SCIENCES↗

Comparing IKONOS and Landsat 7 Images

This work is a continuation of the simulations presented at the previous workshop.INformation is presented on the following: 20 IKONOS images compared with 10 Landsat 7 ETM+VNIR images acquired on the same days. Comparisons are based on simulations of the Landsat 7 images from the IKONOS data. IKONOS and Landsat 7 images used in simulations are on a similar processing level with radiometric correction, georeferenced with cubic-convolution resampling, and UTM projection with WGS-84 datum.

Blonski, Slawomir↗

Advances in mapping of x-ray emission from NIF hohlraums

A newly available ns-gated laser-entrance-hole (GLEH) imager in the National Ignition Facility provides a routine, non-perturbative measurement of hohlraum x-ray emission from inner and outer laser beam deposition regions. The GLEH records the x-ray flux integrated over complex interactions of various part of hohlraum plasma that evolves on a sub-nanosecond time scale. In using these images to unravel hohlraum physics, the first step is to pinpoint the origin inside the hohlraum of the observed x-ray image features. By mapping the hohlraum emission to the GLEH images using high-resolution simulations, one can interpret the GLEH images and gain insight into the hohlraum dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of imaging and flight guidance concepts for rotorcraft zero visibility approach and landing

A simulation experiment to explore the use of an augmented pictorial display to approach and land a helicopter in zero visibility conditions was conducted in a fixed base simulator. A literature search was also conducted to determine related work. A display was developed and pilot in-the-loop evaluations were conducted. The pictorial display was a simulated, high resolution radar image, augmented with various parameters to improve distance and motion cues. Approaches and landings were accomplished, but with higher workloads and less accuracy than necessary for a practical system. Recommendations are provided for display improvements and a follow on simulation study in a moving based simulator.

Mckeown, W. L.↗

(abstract) Synthesis of Speaker Facial Movements to Match Selected Speech Sequences

We are developing a system for synthesizing image sequences the simulate the facial motion of a speaker. To perform this synthesis, we are pursuing two major areas of effort. We are developing the necessary computer graphics technology to synthesize a realistic image sequence of a person speaking selected speech sequences. Next, we are developing a model that expresses the relation between spoken phonemes and face/mouth shape. A subject is video taped speaking an arbitrary text that contains expression of the full list of desired database phonemes. The subject is video taped from the front speaking normally, recording both audio and video detail simultaneously. Using the audio track, we identify the specific video frames on the tape relating to each spoken phoneme. From this range we digitize the video frame which represents the extreme of mouth motion/shape. Thus, we construct a database of images of face/mouth shape related to spoken phonemes. A selected audio speech sequence is recorded which is the basis for synthesizing a matching video sequence; the speaker need not be the same as used for constructing the database. The audio sequence is analyzed to determine the spoken phoneme sequence and the relative timing of the enunciation of those phonemes. Synthesizing an image sequence corresponding to the spoken phoneme sequence is accomplished using a graphics technique known as morphing. Image sequence keyframes necessary for this processing are based on the spoken phoneme sequence and timing. We have been successful in synthesizing the facial motion of a native English speaker for a small set of arbitrary speech segments. Our future work will focus on advancement of the face shape/phoneme model and independent control of facial features.

graphics audio digitizing morphing enunciation pho↗

Imaging the kinetics of anisotropic dissolution of bimetallic core–shell nanocubes using graphene liquid cells

Chemical design of multicomponent nanocrystals requires atomic-level understanding of reaction kinetics. Here, we apply single-particle imaging coupled with atomistic simulation to study reaction pathways and rates of Pd@Au and Cu@Au core-shell nanocubes undergoing oxidative dissolution. Quantitative analysis of etching kinetics using in situ transmission electron microscopy (TEM) imaging reveals that the dissolution mechanism changes from predominantly edge-selective to layer-by-layer removal of Au atoms as the reaction progresses. Dissolution of the Au shell slows down when both metals are exposed, which we attribute to galvanic corrosion protection. Morphological transformations are determined by intrinsic anisotropy due to coordination-number-dependent atom removal rates and extrinsic anisotropy induced by the graphene window. Our work demonstrates that bimetallic coreshell nanocrystals are excellent probes for the local physicochemical conditions inside TEM liquid cells. Furthermore, single-particle TEM imaging and atomistic simulation of reaction trajectories can inform future design strategies for compositionally and architecturally sophisticated nanocrystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗