Search NASA⌕ Search

SEARCH · Search NASA

Results for “interrupt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Quench Protection of the First 4-m-Long Prototype of the HL-LHC Nb$_3$Sn Quadrupole Magnet

The quadrupole magnets for the LHC upgrade to higher luminosity are jointly developed by CERN and US-LARP (LHC Accelerator Research Program). These Nb3Sn magnets will be protected against overheating after a quench by a combination of heaters bonded to the coil outer surface and CLIQ (Coupling-Loss Induced Quench) units. The first 4 meter long prototype magnet, called MQXFAP1, was tested at the Brookhaven National Laboratory in stand-alone configuration. The magnet training campaign, consisting of 18 quenches, was interrupted due to the development of a short circuit between one heater strip and the coil. During the campaign, different quench protection schemes were implemented, including heaters attached to outer and inner layers, one CLIQ unit, and the energy-extraction system. The configuration including outer-layer heaters and CLIQ achieved the fastest current discharge, hence the lowest hot-spot temperature. The electro-magnetic and thermal transients after a quench were simulated with the program STEAM-LEDET and found in good agreement.

43 PARTICLE ACCELERATORS↗

Optimal Operation of Grid-Tied Energy Storage Systems Considering Detailed Device-Level Battery Models

The current optimization-based algorithms to operate grid-tied battery energy storage systems (BESS) typically do not look much under the hood of the BESS, i.e., the device-level characteristics of the batteries. This is often due to modeling as well as optimization complexities. However, simplified models may significantly degrade the performance of BESS operation in practice. Therefore, in this article, we propose a new BESS scheduling optimization framework that accounts for features such as cell-to-cell variations in maximum capacity, charge level balance, and internal resistance. The proposed framework is in the form of tractable mixed integer linear programs. Our approach is to estimate and update the device-level battery model parameters continuously, without the need to interrupt BESS normal operation. We validate the performance compared to an offline approach, which is based on dedicated model testing and calibration. To assure accurate performance evaluation, this article also includes developing a power hardware-in-the-loop testbed that allows for flexible operation and detailed monitoring of BESS under different design scenarios.

25 ENERGY STORAGE↗

Uncertainty-Informed Operation Coordination in a Water-Energy Nexus

The widespread deployment of smart heterogeneous technologies and the growing complexity in our modern society calls for effective coordination of the interdependent lifeline networks. In particular, operation coordination of electric power and water infrastructures is urgently needed as the water system is one of the most energy-intensive networks, an interruption in which may quickly evolve into a dramatic societal concern. This paper develops a novel analytic for uncertainty-aware day-ahead operation optimization of the interconnected power and water systems (PaWS). Joint probabilistic constraint (JPC) programming is employed to capture the uncertainties in wind resources and water demand forecasts. The proposed integrated stochastic model is presented as a non-linear non-convex optimization problem, where the non-linear hydraulic constraints in the water network are linearized using piece-wise linearization technique, and the non-convexity is efficiently tackled with a solution methodology to convert the proposed model with JPCs to a tractable mixed-integer linear programming (MILP) formulation that can be quickly solved to optimality. Here, the suggested framework is applied to a 15-node commercial-scale water network jointly operated with a power transmission system using a modified IEEE 57-bus test system. The numerical results demonstrate the of the proposed stochastic framework, resulting in cost reduction (13% on average when compared to the traditional setting) and energy saving of the integrated model under different realizations of uncertain renewable energy sources (RESs) and water demand scenarios. Additionally, the scalability of the proposed model is tested on a modified IEEE 118-bus test system connected to five water networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of a Thin-Wndow Silicon Drift Detector X-Ray Fluorescence Spectrometer

Several sets of hexagonal Silicon Drift Detector (SDD) arrays were produced by Brookhaven National Laboratory (BNL) and by the commercial vendor, KETEK. These detector arrays were tested at BNL. Each array consists of 14 independent SDD detectors (pixels) and two additional test pixels located at two corners of the array. The side of the detector upon which the X-ray radiation is incident (window side) has a thin junction covering the entire active area. The opposite side (device side) contains a drift-field electrode structure in the form of a hexagonal spiral and an electron collecting anode. There are four guard rings surrounding the 14-pixel array area on each side of the detector. Within each array, seven pixels have aluminum field plates - interrupted spirals that stabilize the electric potential under the Si-SiO{sub 2} interface, while the other seven do not. Three bias voltages are applied to control the drift field in the silicon volume; one is applied to a rectifying contact surrounding the central anode (one for each pixel), one is applied to the detector entrance window (common to the full array), and a third bias is applied to a contact on the outer portion of the spiral, common to all pixels in the array. Some arrays were recently tested in NSLS beam line U3C at BNL. For this work, we installed the complete assemblies in the vacuum and cooled them to -27degC. During this beam run, we collected spectra for energies ranging between 350 and 900 eV in several pixels, some with field plates and others without. The detailed testing results of several arrays are reported here.

79 ASTRONOMY AND ASTROPHYSICS↗

Achieving High Performance With TCP Over 40 GbE on NUMA Architectures for CMS Data Acquisition

TCP and the socket abstraction have barely changed over the last two decades, but at the network layer there has been a giant leap from a few megabits to 100 gigabits in bandwidth. At the same time, CPU architectures have evolved into the multicore era and applications are expected to make full use of all available resources. Applications in the data acquisition domain based on the standard socket library running in a Non-Uniform Memory Access (NUMA) architecture are unable to reach full efficiency and scalability without the software being adequately aware about the IRQ (Interrupt Request), CPU and memory affinities. During the first long shutdown of LHC, the CMS DAQ system is going to be upgraded for operation from 2015 onwards and a new software component has been designed and developed in the CMS online framework for transferring data with sockets. This software attempts to wrap the low-level socket library to ease higher-level programming with an API based on an asynchronous event driven model similar to the DAT uDAPL API. It is an event-based application with NUMA optimizations, that allows for a high throughput of data across a large distributed system. This paper describes the architecture, the technologies involved and the performance measurements of the software in the context of the CMS distributed event building.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural Networks for Modeling and Control of Particle Accelerators

Particle accelerators are host to myriad nonlinear and complex physical phenomena. They often involve a multitude of interacting systems, are subject to tight performance demands, and should be able to run for extended periods of time with minimal interruptions. Often times, traditional control techniques cannot fully meet these requirements. One promising avenue is to introduce machine learning and sophisticated control techniques inspired by artificial intelligence, particularly in light of recent theoretical and practical advances in these fields. Within machine learning and artificial intelligence, neural networks are particularly well-suited to modeling, control, and diagnostic analysis of complex, nonlinear, and time-varying systems, as well as systems with large parameter spaces. Consequently, the use of neural network-based modeling and control techniques could be of significant benefit to particle accelerators. For the same reasons, particle accelerators are also ideal test-beds for these techniques. Many early attempts to apply neural networks to particle accelerators yielded mixed results due to the relative immaturity of the technology for such tasks. The purpose of this paper is to re-introduce neural networks to the particle accelerator community and report on some work in neural network control that is being conducted as part of a dedicated collaboration between Fermilab and Colorado State University (CSU). We describe some of the challenges of particle accelerator control, highlight recent advances in neural network techniques, discuss some promising avenues for incorporating neural networks into particle accelerator control systems, and describe a neural network-based control system that is being developed for resonance control of an RF electron gun at the Fermilab Accelerator Science and Technology (FAST) facility, including initial experimental results from a benchmark controller.

43 PARTICLE ACCELERATORS↗

Exploiting Redundancy and Application Scalability for Cost-Effective, Time-Constrained Execution of HPC Applications on Amazon EC2

The use of clouds to execute high-performance computing (HPC) applications has greatly increased recently. Clouds provide several potential advantages over traditional supercomputers and in-house clusters. The most popular cloud is currently Amazon EC2, which provides fixed-cost and variable-cost, auction-based options. The auction market trades lower cost for potential interruptions that necessitate checkpointing; if the market price exceeds the bid price, a node is taken away from the user without warning. We explore techniques to maximize performance per dollar given a time constraint within which an application must complete. Specifically, we design and implement multiple techniques to reduce expected cost by exploiting redundancy in the EC2 auction market. We then design an adaptive algorithm that selects a scheduling algorithm and determines the bid price. We show that our adaptive algorithm executes programs up to seven times cheaper than using the on-demand market and up to 44 percent cheaper than the best non-redundant, auction-market algorithm. We extend our adaptive algorithm to incorporate application scalability characteristics for further cost savings. In conclusion, we show that the adaptive algorithm informed with scalability characteristics of applications achieves up to 56 percent cost savings compared to the expected cost for the base adaptive algorithm run at a fixed, user-defined scale.

97 MATHEMATICS AND COMPUTING↗

Development, Demonstration, and Control of a Testbed for Multiterminal HVDC System

This paper presents the development of a scaled four-terminal high-voltage direct current (HVDC) testbed, including hardware structure, communication architecture, and different control schemes. The developed testbed is capable of emulating typical operation scenarios including system start-up, power variation, line contingency, and converter station failure. Some unique scenarios are also developed and demonstrated, such as online control mode transition and station re-commission. In particular, a dc line current control is proposed, through the regulation of a converter station at one terminal. By controlling a dc line current to zero, the transmission line can be opened by using relatively low-cost HVDC disconnects with low current interrupting capability, instead of the more expensive dc circuit breaker. Utilizing the dc line current control, an automatic line current limiting scheme is developed. As a result, when a dc line is overloaded, the line current control will be automatically activated to regulate current within the allowable maximum value.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of Inrush Dynamics for Unbalanced Distribution Systems using Phasor Dynamics

Microgrids are a possible solution to mitigate the extensive interruptions in service to end-use customers caused by abnormal events, such as major natural disasters. Microgrids can be formed by energizing portions of the distribution system to interconnect generator and critical loads. In this scenario, inrush dynamic currents can present a barrier for forming microgrids by preventing the necessary switching operations and/or damaging equipment. Modeling inrush dynamics, through electromagnetic transient tools, presents a challenge when the microgrid represents a large portion of a distribution feeder. This paper uses a phasor dynamics approach to approximate the envelope of inrush dynamics, thus allowing simulations of large systems. The two main contributions of this paper are: a) a new formulation to solve a set of phasor-dynamic differential equations representing an unbalanced distribution system; and b) modeling of transformer saturation in the phasor-dynamics frame. These two contributions allow the in-rush phenomena to be simulated on full size microgrid and/or distribution feeder models. The new formulation and model are implemented in GridLAB-D, and tested on IEEE test systems.

inrush, GridLAB-D, distribution analysis, microgri↗

Evaluating the Performance of the IEEE Standard 1366 Method for Identifying Major Event Days

IEEE Standard 1366 offers a method for segmenting reliability performance data to isolate the effects of major events from the underlying year-to-year trends in reliability. Recent analysis by the IEEE Distribution Reliability Working Group (DRWG) has found that reliability performance of some utilities differs from the expectations that helped guide the development of the Standard 1366 method. This paper proposes quantitative metrics to evaluate the performance of the Standard 1366 method in identifying major events and in reducing year-to-year variability in utility reliability. The metrics are applied to a large sample of utility-reported reliability data to assess performance of the method with alternative specifications that have been considered by the DRWG. We find that none of the alternatives perform uniformly 'better' than the current Standard 1366 method. That is, none of the modifications uniformly lowers the year-to-year variability in System Average Interruption Duration Index without major events. Instead, for any given alternative, while it may lower the value of this metric for some utilities, it also increases it for other utilities (sometimes dramatically). Thus, we illustrate some of the trade-offs that must be considered in using the Standard 1366 method and highlight the usefulness of the metrics we have proposed in conducting these evaluations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Analysis of DC Microgrids under Denial of Service Threats

This paper develops a resilience analysis framework to study the fault ride-through capability of direct current (DC) microgrids in unknown denial of service (DoS) cyber incidents. DoS can be a frequent threat to DC microgrids with advanced controllers that hinge on active information exchanges: it can paralyze data communications and cause control ineptness or even system instability. Furthermore, we show that temporal DoS incidents render the DC microgrid cyber-physical topology and parameters time-varying and cause them to jump between faulty conditions. As existing DC microgrid stability analysis results are primarily developed from time-invariant systems, they might not be valid for the DoS interrupted systems. In this paper, we seek to study whether a DC microgrid is resilient against time-varying unknown DoS incidents. The problem is formulated as a stability analysis problem for a system with randomly switching dynamics. Scalable conditions are developed to provide provable resilience guarantees. In addition, we exploit the special structure of the conditions to yield quantified resilience measure by convex optimization techniques. As a result, the measure can be used for the evaluation of the resilience of different DC microgrid design against DoS incidents. We demonstrate the effectiveness of the proposed work using simulation case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Resilience Enhancement in Typhoons Using a Three-Stage Day-Ahead Unit Commitment

In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Evaluation and Enhancement for Island City Integrated Energy Systems

Extreme natural hazards, such as hurricanes or earthquakes, have a high probability of threatening energy supply security and causing high-order contingencies to island city-integrated energy systems (IC-IESs). To better evaluate and enhance resilience, a novel approach is proposed in this work for IC-IESs. The resilience of an IC-IES is analyzed from both the system level and the component level. At the system level, the impacts of extreme natural disasters are quantified. At the component level, the importance of individual components is analyzed through pre-failure and post-failure indices. The pre-failure index identifies the system’s weak links before an energy interruption, and the post-failure index determines the optimal repair strategy to restore the service. The proposed indices are solved by the impact increment method (IIM), which significantly improves computational efficiency without much affecting result accuracy. Numerical simulation studies are conducted on the modified Barry Island IES and IES E123-G48-H32 test systems. Furthermore, the results validate the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Segment Decentralized Control Strategies for Renewables-Rich Microgrids in Extreme Conditions

Microgrids provide a promising approach to accommodating various distributed energy resources (DERs), while requiring significant communication infrastructures that may be affected by extreme conditions such as natural disasters and cyber-attacks. In this paper, a fully decentralized control strategy without the need for communication is proposed for islanded microgrids with high renewables penetration. First, special multi-segment power/frequency characteristic curves are designed, so that different DERs can be automatically coordinated in a prioritized manner such as renewables first to maintain power balance while DER frequencies are regulated at their reference values. Second, piecewise linear served load versus frequency models are designed to prioritize loads according to their significance, so that only noncritical loads will be curtailed as needed while critical loads are supplied without any interruptions during power deficiency. The proposed strategy can effectively deal with various normal and extreme system conditions including 100% renewables penetration, loads and renewables variations, power deficiencies requiring load curtailments, disconnection of existing DERs, connection of new DERs as well as network sectionalization and reconfiguration. As a result, the proposed control strategy is validated in the real-time digital simulator (RTDS) model of the IIT Campus Microgrid to demonstrate its effectiveness in enhancing the resiliency of renewables-rich microgrids in extreme conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VDiSC: An Open Source Framework for Distributed Smart City Vision and Biometric Surveillance Networks

Recent global growth in the interest of smart cities has led to trillions of dollars of investment toward research and development. These connected cities have the potential to create a symbiosis of technology and society and revolutionize the cost of living, safety, ecological sustainability, and quality of life of societies on a world-wide scale. Some key components of the smart city construct are connected smart grids, self-driving cars, federated learning systems, smart utilities, large-scale public transit, and proactive surveillance systems. While exciting in prospect, these technologies and their subsequent integration cannot be attempted without addressing the potential societal impacts of such a high degree of automation and data sharing. Additionally, the feasibility of coordinating so many disparate tasks will require a fast, extensible, unifying framework. To that end, we propose the Distributed Smart City framework for Vision, or VDiSC. VDiSC serves as a unified biometric API harness that allows for seamless evaluation, deployment, and simple pipeline creation for heterogeneous biometric software. VDiSC additionally provides a fully declarative capability for defining and coordinating custom machine learning and sensor pipelines, allowing the distribution of processes across otherwise incompatible hardware and networks. VDiSC ultimately provides a way to quickly configure, hot-swap, and expand large coordinated or federated systems online without interruptions for maintenance. Because much of the data collected in a smart city contains Personally Identifying Information (PII), VDiSC also provides built-in tools and layers to ensure secure and encrypted streaming, storage, and access of PII data across distributed systems.

Brogan, Joel↗

Utilization of lasso peptides for biodegradation of polycyclic aromatic hydrocarbons

Abstract Many microbial genes involved in degrading recalcitrant environmental contaminants such as polycyclic aromatic hydrocarbons (PAHs) have been identified and characterized. However, all molecular mechanisms required for PAH utilization have not yet been elucidated. In this work, we demonstrate the proposed involvement of lasso peptides in the utilization of the PAH phenanthrene in Sphingomonas BPH. Transpositional mutagenesis of Sphingomonas BPH with the miniTn5 transposon yielded 3 phenanthrene utilization deficient mutants, #257, #1778, and #1782. In mutant #1782, Tn5 had inserted into the large subunit of the naph/bph dioxygenase gene. In mutant #1778, Tn5 had inserted into the B2 protease gene of a lasso peptide cluster. This finding is the first report on the role of lasso peptides in PAH utilization. Our studies also demonstrate that interruption of the lasso peptide cluster resulted in a significant increase in the amount of biosurfactant produced in the presence of glucose when compared to the wild‐type strain. Collectively, these results suggest that the mechanisms Sphingomonas BPH utilizes to degrade phenanthrene are far more complex than previously understood and that the #1778 mutant may be a good candidate for bioremediation when glucose is applied as an amendment due to its higher biosurfactant production.

59 BASIC BIOLOGICAL SCIENCES↗

The older plant gets the sun: Age-related changes in Miscanthus × giganteus phenology

Age-related changes are usually overlooked in perennial grass research; when they are considered it is usually as a change in plant size (e.g., biomass). Whether other physiological or developmental aspects change as stands age, and how those aspects may impact long-term stand dynamics, remains unclear. Conventional experimental designs study a single stand over multiple growing seasons and thereby confound age-related changes with growing season conditions. Here we used a staggered-start experimental design with three repeated planting years over two growing seasons to isolate growing season effects. We studied changes in Miscanthus × giganteus phenology during its yield-building stage (first 3 years) and estimated age, growing season and nitrogen (N) effects on development using nonlinear regression parameters. Stand age clearly changed plant growth; faster developmental rates were usually seen in 1-year-old stands (young), but because 2- and 3-year-old stands (mature) emerged 3 months earlier than newly planted stands they produced ~30% more stems with 30%–60% more leaves. Nitrogen fertilization modulated some age-related phenological changes. Fertilized 2-year-old stands reached similar stem densities as unfertilized 3-year-old stands and had fewer number of senesced leaves like 1-year-old stands. In addition, N fertilization had no effect on young M. × giganteus , but extended mature stands’ growing season more than 2 weeks by hastening emergence and delaying senescence. It also delayed flowering regardless of stand age. Our results suggest that, along with changes in size, M. × giganteus stands showed shifts in developmental strategies: young stands emerged later and developed faster, while mature stands grew for longer but more slowly. In temperate regions, where hard frost events are likely to interrupt development in late autumn, rapid early development is critical to plant survival. Nonlinear regression parameter differences proved effective in identifying phenological shifts.

59 BASIC BIOLOGICAL SCIENCES↗