Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

TU-F-CAMPUS-T-01: Calculation of KQ for a Variety of Commercially Available Ionization Chambers in the Presence of An External Magnetic Field for MR-Linac Dosimetry

Purpose: The strong magnetic fields associated with MRI have a significant impact on the dosimetry of radiotherapy beams as well as on the response of the detectors used to measure it. In order to calibrate the dose delivered by these beams, it is necessary to correct for these effects when performing measurements with ionization chambers. Methods: Detailed models of 16 commercially-available ionization chambers were implemented in Geant4. To validate these models, calculations of the beam quality correction factor kQ (defined by TG-51) were performed using the spectrum from a 6 MV Elekta SL25. kQ values were then recalculated for each detector with a 1.5 T external magnetic field applied uniformly across the geometry. Chamber, beam and B-field were all orthogonal. Results: The comparison between the kQ calculations and TG-51 showed agreement within 1.4%. The B-field calculations indicate that the change in kQ values due to the B-field is strongly affected by the volume and material of the ionization chamber. All large volume (>0.5 cm {sup 3}) ionization chambers had lower kQ values when used in a B-field. The kQ values for small volume chambers were very sensitive to the chambers’ collecting volume and could be higher or lower when used in a B-field. Conclusions: Of the chambers tested, the PTW 30011 demonstrated the smallest correction of just 1.2%. The next step is to calculate kQ using the energy spectrum from an actual MR-linac. Further validation of these results against measurements will be paramount before they can be used. Funding provided by Elekta Limited. The MR-linac spectrum will be provided by Elekta Limited based on a machine they have designed.

60 APPLIED LIFE SCIENCES↗

Recombination in liquid-filled ionization chambers beyond the Boag limit

Purpose: The high mass density and low mobilities of charge carriers can cause important recombination in liquid-filled ionization chambers (LICs). Saturation correction methods have been proposed for LICs. Correction methods for pulsed irradiation are based on Boag equation. However, Boag equation assumes that the charge ionized by one pulse is fully collected before the arrival of the next pulse. This condition does not hold in many clinical beams where the pulse repetition period may be shorter than the charge collection time, causing overlapping between charge carriers ionized by different pulses, and Boag equation is not applicable there. In this work, the authors present an experimental and numerical characterization of collection efficiencies in LICs beyond the Boag limit, with overlapping between charge carriers ionized by different pulses. Methods: The authors have studied recombination in a LIC array for different dose-per-pulse, pulse repetition frequency, and polarization voltage values. Measurements were performed in a Truebeam Linac using FF and FFF modalities. Dose-per-pulse and pulse repetition frequency have been obtained by monitoring the target current with an oscilloscope. Experimental collection efficiencies have been obtained by using a combination of the two-dose-rate method and ratios to the readout of a reference chamber (CC13, IBA). The authors have also used numerical simulation to complement the experimental data. Results: The authors have found that overlap significantly increases recombination in LICs, as expected. However, the functional dependence of collection efficiencies on the dose-per-pulse does not change (a linear dependence has been observed in the near-saturation region for different degrees of overlapping, the same dependence observed in the nonoverlapping scenario). On the other hand, the dependence of collection efficiencies on the polarization voltage changes in the overlapping scenario and does not follow that of Boag equation, the reason being that changing the polarization voltage also affects the charge collection time, thus changing the amount of overlapping. Conclusions: These results have important consequences for saturation correction methods for LICs. On one hand, the two-dose-rate method, which relies on the functional dependence of the collection efficiencies on dose-per-pulse, can also be used in the overlapping situation, provided that the two measurements needed to feed the method are performed at the same pulse repetition frequency (monitor unit rate). This result opens the door to computing collection efficiencies in LICs in many clinical setups where charge overlap in the LIC exists. On the other hand, correction methods based on the voltage-dependence of Boag equation like the three-voltage method or the modified two-voltage method will not work in the overlapping scenario due to the different functional dependence of collection efficiencies on the polarization voltage.

60 APPLIED LIFE SCIENCES↗

Fluctuations of induced charge in ionization detectors

Fluctuations of charge induced by charge carriers on the detector electrodes make a significant contribution to the energy resolution of ionization detectors, namely, semiconductor detectors and gas and liquid ionization chambers. These fluctuations are determined by the capture of charge carriers, as they drift in the bulk of the detector under the action of an electric field, by traps. In this study, we give a correct mathematical description of charge induction on electrodes of an ionization detector for an arbitrary electric field distribution in the detector with consideration of charge carrier capture by traps. The characteristic function obtained in this study yields the general expression for the distribution function of the charge induced on the detector electrodes. The formulas obtained in this study are useful for analysis of the influence of charge carrier transport on energy resolution of ionization detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some Problems of Measurements of Ionization Yields for Nuclear Recoils in Liquid Argon Using Neutron Scattering in a Two-Phase Detector

Measurement of the ionization yields for nuclear recoils is related to the energy calibration of dark matter and low-energy neutrino detectors. In this study, some results of the previous measurements of the ionization yields for nuclear recoils in liquid argon using the neutron scattering technique in the two-phase detector are discussed. The methods to increase light collection of scintillation (S{sub 1}) and ionization (S{sub 2}) signals in the two-phase detector using SiPM matrices and THGEM electrodes with increased optical transparency are proposed. These steps are necessary to implement the neutron double-scattering technique, which will provide measurement of the ionization yield of recoiling nuclei in the unexplored energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of resonant charge exchange on the viscosity of partially ionized plasma in a magnetic field

The influence of resonant charge exchange for ion-atom interaction on the viscosity of partially ionized plasma embedded in the magnetic field is investigated. The general system of equations used to derive the viscosity coefficients for an arbitrary plasma component in the 21-moment approximation of Grad’s method is presented. The expressions for the coefficients of total and partial viscosities of a multicomponent partially ionized plasma in the magnetic field are obtained. As an example, the coefficients of the parallel and transverse viscosities for the ionic and neutral components of the partially ionized hydrogen plasma are calculated. It is shown that the account for resonant charge exchange can lead to a substantial change of the parallel and transverse viscosity of the plasma components in the region of low degrees of ionization on the order of 0.1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defect of the well-known (classical) expression for the ionization rate in gas-discharge plasma and its modification

A critical analysis is given of the well-known expression for the electron-impact ionization rate constant α{sub i} of neutral atoms and ions, derived by linearization of the ionization cross section σ{sub i}(ε) as a function of the electron energy near the threshold I and containing the characteristic factor (I + 2kT). Using the classical Thomson expression for the ionization cross section, it is shown that in addition to the linear slope of σ{sub i}(ε), it is also necessary to take into account the large negative curvature of this function near the threshold. In this case, the second term in parentheses changes its sign, which means that the commonly used expression for α{sub i} (∼4kT/I) already at moderate values of the temperature (kT/I ∼ 0.1). The source of this error lies in a mathematical mistake in the original approach and is related to the incorrect choice of the sequential orders of terms small in the parameter kT/I. On the basis of a large amount of experimental data and considerations similar to the Gryzinski theory, a universal two-parameter modification of the Thomson formula (as well as the Bethe—Born formula) is proposed and a new simple expression for the ionization rate constant for arbitrary values of kT/I is derived.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epicyclic helical channels for parametric resonance ionization cooling

Proposed next-generation muon colliders will require major technical advances to achieve rapid muon beam cooling requirements. Parametric-resonance Ionization Cooling (PIC) is proposed as the final 6D cooling stage of a high-luminosity muon collider. In PIC, a half-integer parametric resonance causes strong focusing of a muon beam at appropriately placed energy absorbers while ionization cooling limits the beam’s angular spread. Combining muon ionization cooling with parametric resonant dynamics in this way should then allow much smaller final transverse muon beam sizes than conventional ionization cooling alone. One of the PIC challenges is compensation of beam aberrations over a sufficiently wide parameter range while maintaining the dynamical stability with correlated behavior of the horizontal and vertical betatron motion and dispersion. We explore use of a coupling resonance to reduce the dimensionality of the problem and to shift the dynamics away from non-linear resonances. PIC simulations are presented.

43 PARTICLE ACCELERATORS↗

Partially Ionized Plasma Physics and Technological Applications

Partially ionized plasma physics has attracted increased attention recently due to numerous technological applications made possible by the increased sophistication of computer modelling, the depth of the theoretical analysis, and the technological applications to a vast field of manufacturing for computer components. Partially ionized plasma is characterized by a significant presence of neutral particles in contrast to the fully ionized plasma. The theoretical analysis is based upon solutions of the kinetic Boltzmann equation, yielding the non-Maxwellian electron energy distribution function (EEDF), thereby emphasizing the difference with a fully ionized plasma. The impact of the effect on discharges in inert and molecular gases is described in detail, yielding the complex nonlinear phenomena resulting in plasma selforganization. A few examples of such phenomena are given, including the non-monotonic EEDFs in the discharge afterglow in a mixture of argon with the molecular gas NF3; the explosive generation of cold electron populations in capacitive discharges, hysteresis of EEDF in inductively coupled plasmas. Recently, highly advanced computer codes were developed in order to address the outstanding challenges in plasma technology. These developments are briefly described in general terms.

non-Maxwellian electron energy distribution functi↗

HEATING OF THE WARM IONIZED MEDIUM BY LOW-ENERGY COSMIC RAYS

In light of evidence for a high ionization rate due to low-energy cosmic rays (LECR) in diffuse molecular gas in the solar neighborhood, we evaluate their heat input to the warm ionized medium (WIM). LECR are much more effective at heating plasma than they are at heating neutrals. We show that the upper end of the measured ionization rates corresponds to a local LECR heating rate sufficient to maintain the WIM against radiative cooling, independent of the nature of the ionizing particles or the detailed shape of their spectrum. Elsewhere in the Galaxy the LECR heating rates may be higher than those measured locally. In particular, higher fluxes of LECR have been suggested for the inner Galactic disk, based on the observed hard X-ray emission, with correspondingly larger heating rates implied for the WIM. We conclude that LECR play an important and perhaps dominant role in the thermal balance of the WIM.

79 ASTRONOMY AND ASTROPHYSICS↗

The connection between reddening, gas covering fraction, and the escape of ionizing radiation at high redshift

Using a large sample of spectroscopically confirmed z∼3 galaxies, we establish an empirical relationship between reddening (E(B−V)), neutral gas covering fraction (f{sub cov}(H I)), and the escape of ionizing (Lyman continuum, LyC) photons. Our sample includes 933 galaxies at z∼3,121 of which have deep spectroscopic observations (≳7 hr) at 850≲λ{sub rest}≲1300 Å with the Low Resolution Imaging Spectrograph on Keck. The high covering fraction of outflowing optically thick H I indicated by the composite spectra of these galaxies implies that photoelectric absorption, rather than dust attenuation, dominates the depletion of LyC photons. By modeling the composite spectra as the combination of an unattenuated stellar spectrum including nebular continuum emission with one that is absorbed by H I and reddened by a line-of-sight extinction, we derive an empirical relationship between E(B−V) and f{sub cov}(H I). Galaxies with redder UV continua have larger covering fractions of H I characterized by higher line-of-sight extinctions. We develop a model which connects the ionizing escape fraction with E(B−V), and which may be used to estimate the ionizing escape fraction for an ensemble of galaxies. Alternatively, direct measurements of the escape fraction for our sample allow us to constrain the intrinsic LyC-to-UV flux density ratio to be 〈S(900 A-ring )/S(1500 A-ring )〉{sub int}≳0.20, a value that favors stellar population models that include weaker stellar winds, a flatter initial mass function, and/or binary evolution. Last, we demonstrate how the framework discussed here may be used to assess the pathways by which ionizing radiation escapes from high-redshift galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Turbulent dynamo in a conducting fluid and a partially ionized gas

By following the Kazantsev theory and taking into account both microscopic and turbulent diffusion of magnetic fields, we develop a unified treatment of the kinematic and nonlinear stages of a turbulent dynamo process, and we study the dynamo process for a full range of magnetic Prandtl number P {sub m} and ionization fractions. We find a striking similarity between the dependence of dynamo behavior on P {sub m} in a conducting fluid and R (a function of ionization fraction) in a partially ionized gas. In a weakly ionized medium, the kinematic stage is largely extended, including not only exponential growth but a new regime of dynamo characterized by a linear-in-time growth of magnetic field strength, and the resulting magnetic energy is much higher than the kinetic energy carried by viscous-scale eddies. Unlike the kinematic stage, the subsequent nonlinear stage is unaffected by microscopic diffusion processes and has a universal linear-in-time growth of magnetic energy with the growth rate as a constant fraction 3/38 of the turbulent energy transfer rate, showing good agreement with earlier numerical results. Applying the analysis to the first stars and galaxies, we find that the kinematic stage is able to generate a field strength only an order of magnitude smaller than the final saturation value. But the generation of large-scale magnetic fields can only be accounted for by the relatively inefficient nonlinear stage and requires longer time than the free-fall time. It suggests that magnetic fields may not have played a dynamically important role during the formation of the first stars.

79 ASTRONOMY AND ASTROPHYSICS↗

The highly ionized circumgalactic medium is kinematically uniform around galaxies

The circumgalactic medium (CGM) traced by O vi λλ1031,1037 doublet absorption has been found to concentrate along the projected major and minor axes of the host galaxies. This suggests that O vi traces accreting and outflowing gas, respectively, which are key components of the baryon cycle of galaxies. We investigate this further by examining the kinematics of 29 O vi absorbers associated with galaxies at 0.13<z{sub gal}<0.66 as a function of galaxy color, inclination, and azimuthal angle. Each galaxy was imaged with the Hubble Space Telescope (HST), and the absorption was detected in COS/HST spectra of nearby (D<200 kpc) background quasars. We use the pixel-velocity two-point correlation function to characterize the velocity spread of the absorbers, which is a method used previously for a sample of Mg ii absorber–galaxy pairs. The absorption velocity spread for O vi is more extended than Mg ii, which suggests that the two ions trace differing components of the CGM. Again, in contrast to Mg ii, the O vi absorption velocity spreads are similar regardless of galaxy color, inclination, and azimuthal angle. This indicates that the kinematics of the high-ionization gas is not strongly influenced by the current star formation activity in the galaxy. The kinematic homogeneity of O vi absorption and its tendency to be observed mainly along the projected galaxy major and minor axes is likely due to varying ionization conditions and gas densities about the galaxy. Gas in intermediate azimuthal angles may be ionized out of the O vi phase, possibly resulting in an azimuthal angle dependence of the distribution of gas in higher ionization states.

79 ASTRONOMY AND ASTROPHYSICS↗

HST/COS observations of ionized gas accretion at the disk-halo interface of M33

We report the detection of accreting ionized gas at the disk–halo interface of the nearby galaxy M33. We analyze Hubble Space Telescope/Cosmic Origins Spectrograph absorption-line spectra of seven ultraviolet-bright stars evenly distributed across the disk of M33. We find Si iv absorption components consistently redshifted relative to the bulk M33's ISM absorption along all the sightlines. The Si iv detection indicates an enriched, disk-wide, ionized gas inflow toward the disk. This inflow is most likely multi-phase as the redshifted components can also be observed in ions with lower ionization states (e.g., S ii, P ii, Fe ii, Si ii). Kinematic modeling of the inflow is consistent with an accreting layer at the disk–halo interface of M33, which has an accretion velocity of 110{sub −20}{sup +15} km s{sup −1} at a distance of 1.5{sub −1.0}{sup +1.0} kpc above the disk. The modeling indicates a total mass of ∼3.9 × 10{sup 7} M {sub ⊙} for the accreting material at the disk–halo interface on the near side of the M33 disk, with an accretion rate of ∼2.9 M {sub ⊙} yr{sup −1}. The high accretion rate and the level of metal enrichment suggest the inflow is likely to be the fallback of M33 gas from a galactic fountain and/or the gas pulled loosed during a close interaction between M31 and M33. Our study of M33 is the first to unambiguously reveal the existence of a disk-wide, ionized gas inflow beyond the Milky Way, providing a better understanding of gas accretion in the vicinity of a galaxy disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-fluid Approach to High-frequency Waves in Plasmas. II. Small-amplitude Regime in Partially Ionized Media

The presence of neutral species in a plasma has been shown to greatly affect the properties of magnetohydrodynamic waves. For instance, the interaction between ions and neutrals through momentum transfer collisions causes the damping of Alfvén waves and alters their oscillation frequency and phase speed. When the collision frequencies are larger than the frequency of the waves, single-fluid magnetohydrodynamic approximations can accurately describe the effects of partial ionization, since there is a strong coupling between the various species. However, at higher frequencies, the single-fluid models are not applicable and more complex approaches are required. Here, we use a five-fluid model with three ionized and two neutral components, which takes into consideration Hall’s current and Ohm’s diffusion in addition to the friction due to collisions between different species. We apply our model to plasmas composed of hydrogen and helium, and allow the ionization degree to be arbitrary. By analyzing the corresponding dispersion relation and numerical simulations, we study the properties of small-amplitude perturbations. We discuss the effect of momentum transfer collisions on the ion-cyclotron resonances and compare the importance of magnetic resistivity, and ion–neutral and ion–ion collisions on the wave damping at various frequency ranges. Applications to partially ionized plasmas of the solar atmosphere are performed.

79 ASTRONOMY AND ASTROPHYSICS↗

Which Stars Are Ionizing the Orion Nebula?

The common assumption that θ{sup 1} Ori C is the dominant ionizing source for the Orion Nebula is critically examined. This assumption underlies much of the existing analysis of the nebula. In this paper we establish through comparison of the relative strengths of emission lines with expectations from Cloudy models and through the direction of the bright edges of proplyds that θ{sup 2} Ori A, which lies beyond the Bright Bar, also plays an important role. θ{sup 1} Ori C does dominate ionization in the inner part of the Orion Nebula, but outside of the Bright Bar as far as the southeast boundary of the Extended Orion Nebula, θ{sup 2} Ori A is the dominant source. In addition to identifying the ionizing star in sample regions, we were able to locate those portions of the nebula in 3D. This analysis illustrates the power of MUSE spectral imaging observations to identify sources of ionization in extended regions.

79 ASTRONOMY AND ASTROPHYSICS↗

A Theoretical Study of the Outer Layers of Eight Kepler F-stars: The Relevance of Ionization Processes

We have analyzed the theoretical model envelopes of eight Kepler F-stars by computing the phase shift of the acoustic waves, α(ω), and its related function, β(ω). The latter is shown to be a powerful probe of the external stellar layers since it is particularly sensitive to the partial ionization zones located in these upper layers. We found that these theoretical envelopes can be organized into two groups, each of which is characterized by a distinct β(ω) shape that we show to reflect the differences related to the magnitudes of ionization processes. Since β(ω) can also be determined from the experimental frequencies, we compared our theoretical results with the observable β(ω). Using the function β(ω), and with the purpose of quantifying the magnitude of the ionization processes occurring in the outer layers of these stars, we define two indexes, Δβ{sub 1} and Δβ{sub 2}. These indexes allow us to connect the microphysics of the interior of the star with macroscopic observable characteristics. Motivated by the distinct magnetic activity behaviors of F-stars, we studied the relation between the star’s rotation period and these indexes. We found a trend, in the form of a power-law dependence, that favors the idea that ionization is acting as an underlying mechanism, which is crucial for understanding the relation between rotation and magnetism and even observational features such as the Kraft break.

79 ASTRONOMY AND ASTROPHYSICS↗

Clusters of DNA induced by ionizing radiation: formation of short DNA fragments. I. Theoretical modeling

We have developed a general theoretical model for the interaction of ionizing radiation with chromatin. Chromatin is modeled as a 30-nm-diameter solenoidal fiber comprised of 20 turns of nucleosomes, 6 nucleosomes per turn. Charged-particle tracks are modeled by partitioning the energy deposition between primary track core, resulting from glancing collisions with 100 eV or less per event, and delta rays due to knock-on collisions involving energy transfers >100 eV. A Monte Carlo simulation incorporates damages due to the following molecular mechanisms: (1) ionization of water molecules leading to the formation of OH, H, eaq, etc.; (2) OH attack on sugar molecules leading to strand breaks: (3) OH attack on bases; (4) direct ionization of the sugar molecules leading to strand breaks; (5) direct ionization of the bases. Our calculations predict significant clustering of damage both locally, over regions up to 40 bp and over regions extending to several kilobase pairs. A characteristic feature of the regional damage predicted by our model is the production of short fragments of DNA associated with multiple nearby strand breaks. The shapes of the spectra of DNA fragment lengths depend on the symmetries or approximate symmetries of the chromatin structure. Such fragments have subsequently been detected experimentally and are reported in an accompanying paper (B. Rydberg, Radiat, Res. 145, 200-209, 1996) after exposure to both high- and low-LET radiation. The overall measured yields agree well quantitatively with the theoretical predictions. Our theoretical results predict the existence of a strong peak at about 85 bp, which represents the revolution period about the nucleosome. Other peaks at multiples of about 1,000 bp correspond to the periodicity of the particular solenoid model of chromatin used in these calculations. Theoretical results in combination with experimental data on fragmentation spectra may help determine the consensus or average structure of the chromatin fibers in mammalian DNA.

Non-NASA Center↗

TIME-VARYING FLAME IONIZATION SENSING APPLIED TO NATURAL GAS AND PROPANE BLENDS IN A PRESSURIZED LEAN PREMIXED (LPM) COMBUSTOR

In-situ monitoring of combustion phenomena is a critical need for optimal operation and control of advanced gas turbine combustion systems. The concept described in this paper is based on naturally occurring flame ionization processes that accompany the combustion of hydrocarbon fuels. Previous work has shown that flame ionization techniques may be applied to detect flashback, lean blowout, and some aspects of thermo-acoustic combustion instabilities. Previous work has focused on application of DC electric fields. By application of time-varying electric fields, significant improvements to sensor capabilities have been observed. These data have been collected in a lean premixed combustion test rig operating at 0.51-0.76 MPa (5-7.5 atm) with air preheated to 588 K (600°F). Five percent of the total fuel flow is injected through the centerbody tip as a diffusion pilot. The fuel composition is varied independently by blending approximately 5% (volume) propane with the pipeline natural gas. The reference velocity through the premixing annulus is kept constant for all conditions at a nominal value of 70 m/s. The fuel-air equivalence ratio is varied independently from 0.46 – 0.58. Relative to the DC field version, the time-varying combustion control and diagnostic sensor (TV-CCADS) shows a significant improvement in the correlation between the measured flame ionization current and local fuel-air equivalence ratio. In testing with different fuel compositions, the triangle wave data show the most distinct change in flame ionization current in response to an increase in propane content. Continued development of this sensor technology will improve the capability to control advanced gas turbine combustion systems, and help address issues associated with variations in fuel supplies.

03 NATURAL GAS↗