Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Ultra-Low Noise Laser and Optical Frequency Comb-Based Timing System for the Event Horizon Explorer (EHE) Mission

Very Long Baseline Interferometry (VLBI) requires a highly stable time reference and synchronization system to maintain coherence between observations recorded independently at multiple stations – for example, the array of ground-based radio telescopes that comprise the Event Horizon Telescope (EHT). Instability in the time reference or inaccuracy in the synchronization impacts phase conference and reduces the performance of the VLBI system. For space-based telescopes like the Event Horizon Explorer (EHE) mission, the precision timing system must meet the size, weight, and power (SWaP) constraints of the spacecraft platform and be capable of operating in the space environment. The EHE mission is a proposed extension to the EHT that can improve the angular and time resolution of observations by enabling longer interferometric baselines than are possible on the Earth and sampling a wide range of Fourier spatial frequencies throughout the orbital motion. In this effort, we demonstrate the performance of one option for the EHE mission: the use of a space-qualified, ultra-low noise laser developed as part of the Laser Interferometer Space Antenna (LISA) mission as the timing reference, and an optical frequency comb to transfer the stability of this laser to the microwave regime for instrumentation use. We describe the implementation of the microwave down-conversion, in which the LISA cavity-stabilized laser is locked to a self-referenced optical frequency comb to divide the optical frequency down to 100 MHz. The phase noise of the 100 MHz signal is measured and validated using a phase noise analyzer that is referenced to a separate laboratory ultra-stable laser system. We present the results of this experiment, which demonstrates that the performance of this system meets the EHE requirement: a relative frequency error of 1e-14 from 1 to 30 seconds.

Hannah Tomio↗

Noise power spectral density of a fibre scattered-light interferometer with a semiconductor laser source

Spectral characteristics of the noise intensity fluctuations at the output of a scattered-light interferometer, caused by phase fluctuations of semiconductor laser radiation are considered. This kind of noise is one of the main factors limiting sensitivity of interferometric sensors. For the first time, to our knowledge, the expression is obtained for the average noise power spectral density at the interferometer output versus the degree of a light source coherence and length of the scattering segment. Also, the approximate expressions are considered which determine the power spectral density in the low-frequency range (up to 200 kHz) and in the limiting case of extended scattering segments. The expression obtained for the noise power spectral density agrees with experimental normalised power spectra with a high accuracy. (interferometry of radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electro-optic modulation of a laser at microwave frequencies for interferometric purposes

A multi-point microwave interferometer (MPMI) concept was previously proposed by the authors for spatially-resolved, non-invasive tracking of a shock, reaction, or detonation front in energetic media [P. Specht et al., AIP Conf. Proc. 1793, 160010 (2017).]. The advantage of the MPMI concept over current microwave interferometry techniques is its detection of Doppler shifted microwave signals through electro-optic (EO) modulation of a laser. Since EO modulation preserves spatial variations in the Doppler shift, collecting the EO modulated laser light into a fiber array for recording with an optical heterodyne interferometer yields spatially-resolved velocity information. This work demonstrates the underlying physical principle of the MPMI diagnostic: the monitoring of a microwave signal with nanosecond temporal resolution using an optical heterodyne interferometer. For this purpose, the MPMI concept was simplified to a single-point construction using two tunable 1550 nm lasers and a 35.2 GHz microwave source. A (110) ZnTe crystal imparted the microwave frequency onto a laser, which was combined with a reference laser for determination of the microwave frequency in an optical heterodyne interferometer. A single, characteristic frequency associated with the microwave source was identified in all experiments, providing a means to monitor a microwave signal on nanosecond time scales. Lastly, areas for improving the frequency resolution of this technique are discussed, focusing on increasing the phase-modulated signal strength.

Specht, Paul E. (ORCID:000000027007000X)↗

LISA Optics Model

The LISA experiment has six telescopes, in three spacecraft, in orbit about the sun. There is a continuous laser link between all of the spacecraft. Because of the large, 5 million kilometer distances, between the spacecraft and the need to perform picometer level interferometry and the fact that the optical system is dynamic precludes the use of standard optical codes in the design and analysis of this optical system. A detailed description of the approach used to model all of the optics, in the spacecraft in orbit, is presented and the ability of this model to analyze requirements is discussed. A dynamic computer simulation will be shown to illustrate the laser link and the effects of this dynamic environment on the interferometry.

Waluschka, Eugene↗

Fringe localization requirements for three-dimensional flow visualization of shock waves in diffuse-illumination double-pulse holographic interferometry

A theory of fringe localization in rapid-double-exposure, diffuse-illumination holographic interferometry was developed. The theory was then applied to compare holographic measurements with laser anemometer measurements of shock locations in a transonic axial-flow compressor rotor. The computed fringe localization error was found to agree well with the measured localization error. It is shown how the view orientation and the curvature and positional variation of the strength of a shock wave are used to determine the localization error and to minimize it. In particular, it is suggested that the view direction not deviate from tangency at the shock surface by more than 30 degrees.

Decker, A. J.↗

Comparison of terrestrial reference frame velocities determined from SLR and VLBI

The most recent site velocity solutions from the Very Long Baseline Interferometry (VLBI) analysis group at the Goddard Space Flight Center and the Satellite Laser Ranging (SLR) analysis group at the University of Texas Center for Space Research are compared. The results indicate that the horizontal velocities agree, after removing a velocity transformation of a few millimeters per year, to the 2-3 millimeter per year level in an rms sense. The velocities of the best observed sites agree to nearly 1 mm/yr in each horizontal component. In addition, when only sites with adjusted velocities are compared, the agreement of epoch site positions is improved over previous studies to the subcentimeter level in the horizontal components. The sites in the western United States agree at the few millimeter level.

Watkins, M. M.↗

Technology for Space Optical Interferometry

Optical interferometers are expected to provide the next great leap forward in space based astronomy beyond the Hubble Space Telescope. Various systems are envisioned, ranging from large orbiting structures to lunar based facilities to separated spacecraft flying in formation. Regardless of the specific architecture, these systems will present unprecedented challenges in the measurement and control of optical surfaces, hence driving the technological state-of-the-art in the areas of laser metrology and alignment and stabilization of optomechanical systems.

interferometry↗

Density measurements in an expanding flow using holographic interferometry

A nonequilibrium expansion of nitrogen through a 2-dimensional nozzle of a reflected shock tunnel is investigated with laser holography, time resolved pressure measurements and emission spectroscopy to characterize the flow field for vibrational relaxation measurements. A 2D computation is used to simulate the nozzle flow field. Synthetic holograms are generated using the computed density profiles and are compared with the experimental holograms. Also, using a quasi 1-D approximation, populations for each vibrational level are computed by (1) solving the master equations and (2) using the Landau-Teller formulation. Computational accuracy of both models is assessed against the experimental data.

Sharma, Surendra P.↗

Holographic flow visualization at NASA Langley

Holographic flow visualization systems at two NASA Langley facilities, a hypersonic blow-down tunnel using CF4 gas and an expansion tube with very short test time, are described. A pulsed ruby laser is used at a CF4 tunnel for single pulse holography, double pulse with several minutes between exposures, and dual plate holographic interferometry. Shadowgraph, schlieren, and interferograms are reconstructed from the holograms in a separate reconstruction lab. At the expansion tube the short run time of 200 microseconds requires precise triggering of its double pulsed ruby laser. With double pulse capability of 20 to 1200 microseconds pulse separation, one pulse can occur before and one later after flow is established to obtain fringe free background interferograms (perfect infinite fringe) or both pulses can occur during flow in order to study flow instabilities. Holograms are reconstructed at the expansion tube with an in-place setup which makes use of a high power CW Argon laser and common optics for both recording and reconstructing the holograms. The holographic systems at the CF4 tunnel and expansion tube are operated routinely for flow visualization by tunnel technicians. Typical flow visualization photographs from both facilities are presented.

Burner, A. W.↗

Combined single-pulse holography and time-resolved laser schlieren for flow visualization

A pulsed ruby laser and continuous-wave argon ion laser were used in a combined setup at the Langley Expansion Tube for single pulse holography and time resolved laser schlieren with a common optical axis. The systems can be operated simultaneously for a single run. For a single frame, the pulsed holographic setup offers the options of shadowgraph, Schlieren, and interferometry from the reconstructed hologram as well as the advantage of post-run sensitivity adjustments. For flow establishment studies the time resolved laser Schlieren provides visualization of the flow field every 12.5 microns for up to 80 frames with an exposure time per frame of 5.4 microns.

Burner, A. W.↗

An apparatus for the characterization of warm, dense deuterium with inelastic x-ray scattering

Here, we present an instrument platform for studying shock-compressed deuterium on moderately sized laser facilities. The target is designed for cryogenic liquid deuterium to be compressed with a sub-kJ laser pulse. The x-ray probe is the narrow band 2005 eV Si Ly-α resonance produced by a 200J laser incident on a Si 3 N 4 foil. Scattered x-ray collection occurs in the backward and forward directions; spectral dispersion with Bragg crystals yields the plasma conditions of density and temperature. Additionally, the shock is probed with velocity interferometry. Combined with the electron density measurements from forward scattering, this allows average ionization state to be inferred. Proof of principle experiments demonstrate the viability of this technique for studies of the ionization of deuterium along the Hugoniot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-chord fiber-coupled interferometry of supersonic plasma jets (invited)

A multi-chord fiber-coupled interferometer is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment. The long coherence length of the laser (>10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which both positive and negative phase shift values are observed depending on the ionization fraction. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity ({approx}15-50 km/s), jet length ({approx}20-100 cm), and 3D expansion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic Flow Visualization at NASA Langley

Holographic flow visualization systems at two NASA Langley facilities, a hypersonic blow-down tunnel using CF4 gas and an expansion tube with very short test time, are described. A pulsed ruby laser is used at a CF4 tunnel for single pulse holography, double pulse with several minutes between exposures, and dual plate holographic interferometry. Shadow-graph, schlieren, and interferograms are reconstructed from the holograms in a separate reconstruction lab. At the expansion tube the short run time of 200 microseconds requires precise triggering of its double pulsed ruby laser. With pulse separation, one pulse can occur before and one after flow is established to obtain fringe free background interferograms (perfect infinite fringe) or both pulses can occur during flow in order to study flow instabilities. Holograms are reconstructed at the expansion tube with an in-place setup which makes use of a high power CW Argon laser and common optics for both recording and reconstructing the holograms. The holographic systems at the CF4 tunnel and expansion tube are operated routinely for flow visualization by tunnel technicians. Typical flow visualization photographs from both facilities are presented.

Burner, A. W.↗

Present status and future prospects for NASA's program in geodynamics

An overview of NASA's involvement in developing systems for precise determination of polar motion, earth rotation, and position on the earth's surface is given. The observational methods discussed are laser ranging to the moon and to artificial satellites, and very long baseline microwave interferometry. A plan for a geodynamics program to apply space technology to research in earth dynamics is outlined.

Flinn, E. A.↗

Dynamics of the plumes produced by ultrafast laser ablation of metals

We have analyzed ultrafast laser ablation of a metallic target (Nickel) in high vacuum addressing both expansion dynamics of the various plume components (ionic and nanoparticle) and basic properties of the ultrafast laser ablation process. While the ion temporal profile and ion angular distribution were analyzed by means of Langmuir ion probe technique, the angular distribution of the nanoparticulate component was characterized by measuring the thickness map of deposition on a transparent substrate. The amount of ablated material per pulse was found by applying scanning white light interferometry to craters produced on a stationary target. We have also compared the angular distribution of both the ionic and nanoparticle components with the Anisimov model. While the agreement for the ion angular distribution is very good at any laser fluence (from ablation threshold up to {approx_equal}1 J/cm{sup 2}), some discrepancies of nanoparticle plume angular distribution at fluencies above {approx_equal}0.4 J/cm{sup 2} are interpreted in terms of the influence of the pressure exerted by the nascent atomic plasma plume on the initial hydrodynamic evolution of the nanoparticle component. Finally, analyses of the fluence threshold and maximum ablation depth were also carried out, and compared to predictions of theoretical models. Our results indicate that the absorbed energy is spread over a length comparable with the electron diffusion depth L{sub c} ({approx_equal}30 nm) of Ni on the timescale of electron-phonon equilibration and that a logarithmic dependence is well-suited for the description of the variation in the ablation depth on laser fluence in the investigated range.

36 MATERIALS SCIENCE↗