Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Extension and Validation of the Pendulum Model for Longitudinal Solar Prominence Oscillations

Context. Longitudinal oscillations in prominences are common phenomena on the Sun. These oscillations can be used to infer the geometry and intensity of the filament magnetic field. Previous theoretical studies of longitudinal oscillations made two simplifying assumptions: uniform gravity and semicircular dips on the supporting flux tubes. However, the gravity is not uniform and realistic dips are not semicircular. Aims. Our aim is to understand the effects of including the nonuniform solar gravity on longitudinal oscillations and explore the validity of the pendulum model with different flux-tube geometries. Methods. We first derived the equation describing the motion of the plasma along the flux tube including the effects of nonuniform gravity, yielding corrections to the original pendulum model. We also computed the full numerical solutions for the normal modes and compared them with the new pendulum approximation. Results. We find that the nonuniform gravity introduces a significant modification in the pendulum model. We also found a cut-off period; i.e., the longitudinal oscillations cannot have a period longer than 167 min. In addition, considering different tube geometries, the period depends almost exclusively on the radius of curvature at the bottom of the dip. Conclusions. We conclude that nonuniform gravity significantly modifies the pendulum model. These corrections are important for prominence seismology, because the inferred values of the radius of curvature and minimum magnetic-field strength differ substantially from those of the old model. However, we find that the corrected pendulum model is quite robust and is still valid for noncircular dips.

Sun: corona↗

Spine Stereotactic Body Radiotherapy Utilizing Cone-Beam CT Image-Guidance With a Robotic Couch: Intrafraction Motion Analysis Accounting for all Six Degrees of Freedom

Purpose: To evaluate the residual setup error and intrafraction motion following kilovoltage cone-beam CT (CBCT) image guidance, for immobilized spine stereotactic body radiotherapy (SBRT) patients, with positioning corrected for in all six degrees of freedom. Methods and Materials: Analysis is based on 42 consecutive patients (48 thoracic and/or lumbar metastases) treated with a total of 106 fractions and 307 image registrations. Following initial setup, a CBCT was acquired for patient alignment and a pretreatment CBCT taken to verify shifts and determine the residual setup error, followed by a midtreatment and posttreatment CBCT image. For 13 single-fraction SBRT patients, two midtreatment CBCT images were obtained. Initially, a 1.5-mm and 1 Degree-Sign tolerance was used to reposition the patient following couch shifts which was subsequently reduced to 1 mm and 1 Degree-Sign degree after the first 10 patients. Results: Small positioning errors after the initial CBCT setup were observed, with 90% occurring within 1 mm and 97% within 1 Degree-Sign . In analyzing the impact of the time interval for verification imaging (10 {+-} 3 min) and subsequent image acquisitions (17 {+-} 4 min), the residual setup error was not significantly different (p > 0.05). A significant difference (p = 0.04) in the average three-dimensional intrafraction positional deviations favoring a more strict tolerance in translation (1 mm vs. 1.5 mm) was observed. The absolute intrafraction motion averaged over all patients and all directions along x, y, and z axis ({+-} SD) were 0.7 {+-} 0.5 mm and 0.5 {+-} 0.4 mm for the 1.5 mm and 1 mm tolerance, respectively. Based on a 1-mm and 1 Degree-Sign correction threshold, the target was localized to within 1.2 mm and 0.9 Degree-Sign with 95% confidence. Conclusion: Near-rigid body immobilization, intrafraction CBCT imaging approximately every 15-20 min, and strict repositioning thresholds in six degrees of freedom yields minimal intrafraction motion allowing for safe spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface hopping outperforms secular Redfield theory when reorganization energies range from small to moderate (and nuclei are classical)

We evaluate the accuracy of Tully’s surface hopping algorithm for the spin-boson model in the limit of small to moderate reorganization energy. We calculate transition rates between diabatic surfaces in the exciton basis and compare against exact results from the hierarchical equations of motion; we also compare against approximate rates from the secular Redfield equation and Ehrenfest dynamics. We show that decoherence-corrected surface hopping performs very well in this regime, agreeing with secular Redfield theory for very weak system-bath coupling and outperforming secular Redfield theory for moderate system-bath coupling. Surface hopping can also be extended beyond the Markovian limits of standard Redfield theory. Given previous work [B. R. Landry and J. E. Subotnik, J. Chem. Phys. 137, 22A513 (2012)] that establishes the accuracy of decoherence-corrected surface-hopping in the Marcus regime, this work suggests that surface hopping may well have a very wide range of applicability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prostate Planning Treatment Volume Margin Calculation Based on the ExacTrac X-Ray 6D Image-Guided System: Margins for Various Clinical Implementations

Purpose: To assess the prostate motion from day-to-day setup, as well as during irradiation time, to calculate planning target volume (PTV) margins. PTV margins differ depending on the clinical implementation of an image-guided system. Three cases were considered in this study: daily bony anatomy match, center of gravity of the implanted marker seeds calculated with a limited number of imaged days, and daily online correction based on implanted marker seeds. Methods and Materials: A cohort of 30 nonrandomized patients and 1,330 pairs of stereoscopic kV images have been used to determine the prostate movement. The commercial image guided positioning tool employed was ExacTrac X-Ray 6D (BrainLAB AG, Feldkirchen, Germany). Results: Planning target volume margins such that a minimum of 95% of the prescribed dose covers the clinical target volume for 90% of the population are presented. PTV margins based on daily bony anatomy match, including intrafraction correction, would be 11.5, 13.5, and 4.5 mm in the anterior-posterior, superior-inferior, and right-left directions, respectively. This margin can be further reduced to 8.1, 8.6, and 4.8 mm (including intrafraction motion) if implanted marker seeds are used. Finally, daily on line correction based on marker seeds would result in the smallest of the studied margins: 4.7, 6.2, and 1.9 mm. Conclusion: Planning target volume margins are dependent on the local clinical use of the image-guided RT system available in any radiotherapy department.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mixed-Precision Spectral Deferred Correction: Preprint

Convergence of spectral deferred correction (SDC), where low-order time integration methods are used to construct higher-order methods through iterative refinement, can be accelerated in terms of computational effort by using mixed-precision methods. Using ideas from multi-level SDC (in turn based on FAS multigrid ideas), some of the SDC correction sweeps can use function values computed in reduced precision without adversely impacting the accuracy of the final solution. This is particularly beneficial for the performance of combustion solvers such as S3D [6] which require double precision accuracy but are performance limited by the cost of data motion.

97 MATHEMATICS AND COMPUTING↗

Motion of 1/3<111> dislocations on Σ3 (112) twin boundaries in nanotwinned copper

The atomic structure of Σ3 (112) ITBs in nanotwinned Cu is investigated by using aberration-corrected high resolution transmission electron microscopy (HRTEM) and in situ HRTEM observations. The Σ3 (112) ITBs are consisted of periodically repeated three partial dislocations. The in situ HRTEM results show that 1/3[111] partial dislocation moves on the Σ3 (112) incoherent twin boundary (ITB), which was accompanied by a migration of the ITB. A dislocation reaction mechanism is proposed for the motion of 1/3[111] Frank partial dislocation, in which the 1/3[111] partial dislocation exchanges its position with twin boundary dislocations in sequence. In this way, the 1/3[111] dislocation can move on the incoherent twin boundary in metals with low stacking fault energy. Meanwhile, the ITB will migrate in its normal direction accordingly. These results provide insight into the reaction mechanism of 1/3[111] dislocations and ITBs and the associated migration of ITBs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experiences at the Paul Scherrer Institute With a Remote Patient Positioning Procedure for High-Throughput Proton Radiation Therapy

Purpose: To describe a remote positioning system for accurate and efficient proton radiotherapy treatments. Methods and Materials: To minimize positioning time in the treatment room (and thereby maximize beam utility), we have adopted a method for remote patient positioning, with patients positioned and imaged outside the treatment room. Using a CT scanner, positioning is performed using orthogonal topograms with the measured differences to the reference images being used to define daily corrections to the patient table in the treatment room. Possible patient movements during transport and irradiation were analyzed through periodic acquisition of posttreatment topograms. Systematic and random errors were calculated for this daily positioning protocol and for two off-line protocols. The potential time advantage of remote positioning was assessed by computer simulation. Results: Applying the daily correction protocol, systematic errors calculated over all patients (n = 94) were below 0.6 mm, whereas random errors were below 1.5 mm and 2.5 mm, respectively, for bite-block and for mask immobilization. Differences between pre- and posttreatment images were below 2.8 mm (SD) in abdominal/pelvic region, and below 2.4 mm (SD) in the head. Retrospective data analysis for a subset of patients revealed that off-line protocols would be significantly less accurate. Computer simulations showed that remote positioning can increase patient throughput up to 30%. Conclusions: The use of a daily imaging and correction protocol based on a 'remote' CT could reduce positioning errors to below 2.5 mm and increase beam utility in the treatment room. Patient motion between imaging and treatment were not significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Schrödinger cat states of a nuclear spin qudit in silicon

High-dimensional quantum systems are a valuable resource for quantum information processing. They can be used to encode error-correctable logical qubits, which has been demonstrated using continuous-variable states in microwave cavities or the motional modes of trapped ions. For example, high-dimensional systems can be used to realize ‘Schrödinger cat’ states, which are superpositions of widely displaced coherent states that can be used to illustrate quantum effects at large scales. Recent proposals have suggested encoding qubits in high-spin atomic nuclei, which are finite-dimensional systems that can host hardware-efficient versions of continuous-variable codes. Here, in this study, we demonstrate the creation and manipulation of Schrödinger cat states using the spin-7/2 nucleus of an antimony atom embedded in a silicon nanoelectronic device. We use a multi-frequency control scheme to produce spin rotations that preserve the symmetry of the qudit, and we constitute logical Pauli operations for qubits encoded in the Schrödinger cat states. Our work demonstrates the ability to prepare and control non-classical resource states, which is a prerequisite for applications in quantum information processing and quantum error correction, using our scalable, manufacturable semiconductor platform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gains From Real-Time Tracking of Prostate Motion During External Beam Radiation Therapy

Purpose: To study the gains from real-time tracking of prostate motion and threshold-based intervention and the feasibility of margin reduction for external beam radiation therapy of prostate cancer. Methods and Materials: Prostate intrafractional motion data from 775 randomly selected treatment fractions (105 prostate patients) were analyzed. Statistical distributions of prostate intrafractional displacement from baseline were used for treatment margin calculation together with other geometrical uncertainties for all patients and a subset of 7 patient who exhibited the largest intrafractional motion. Compared with treatment without any intrafractional intervention, potential reductions in treatment margins were evaluated for treatments with 5-mm and 3-mm threshold-based intervention and four-dimensional (4D) treatments with and without prostate rotation correction. Results: The percentage of time of prostate displacement from the baseline by 3 mm and 5 mm in any direction was 13.4% and 1.8%, respectively, for the general patient population. The ratios were 41% and 15% for the 7 selected patients. Reductions in the posterior margin were 0.2, 0.5, 1.3, and 3.1 mm from the original 7.7 mm, respectively, for 5-mm and 3-mm threshold-based treatments and 4D treatments with and without prostate rotation correction for all patients. They were 1.3, 1.9, 3.1 and 4.9 mm from the original 9.5 mm, corresponding to the 7 selected patients. The treatment margin reductions in other directions were even smaller. Conclusions: Real-time motion tracking and threshold-based intrafractional intervention may play a significant roll in treatment margin reduction for a small fraction of patients but not for the general patient population. Four-dimensional treatments with prostate rotation correction can reduce the treatment margin more significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of a Robotic 6-Degree of Freedom Treatment Couch for Frameless Radiosurgery

Purpose: To evaluate the added value of 6-degree of freedom (DOF) patient positioning with a robotic couch compared with 4DOF positioning for intracranial lesions and to estimate the immobilization characteristics of the BrainLAB frameless mask (BrainLAB AG, Feldkirchen, Germany), more specifically, the setup errors and intrafraction motion. Methods and Materials: We enrolled 40 patients with 66 brain metastases treated with frameless stereotactic radiosurgery and a 6DOF robotic couch. Patient positioning was performed with the BrainLAB ExacTrac stereoscopic X-ray system. Positioning results were collected before and after treatment to assess patient setup error and intrafraction motion. Existing treatment planning data were loaded and simulated for 4DOF positioning and compared with the 6DOF positioning. The clinical relevance was analyzed by means of the Paddick conformity index and the ratio of prescribed isodose volume covered with 4DOF to that obtained with the 6DOF positioning. Results: The mean three-dimensional setup error before 6DOF correction was 1.91 mm (SD, 1.25 mm). The rotational errors were larger in the longitudinal (mean, 0.23 Degree-Sign ; SD, 0.82 Degree-Sign ) direction compared with the lateral (mean, -0.09 Degree-Sign ; SD, 0.72 Degree-Sign ) and vertical (mean, -0.10 Degree-Sign ; SD, 1.03 Degree-Sign ) directions (p < 0.05). The mean three-dimensional intrafraction shift was 0.58 mm (SD, 0.42 mm). The mean intrafractional rotational errors were comparable for the vertical, longitudinal, and lateral directions: 0.01 Degree-Sign (SD, 0.35 Degree-Sign ), 0.03 Degree-Sign (SD, 0.31 Degree-Sign ), and -0.03 Degree-Sign (SD, 0.33 Degree-Sign ), respectively. The mean conformity index decreased from 0.68 (SD, 0.08) (6DOF) to 0.59 (SD, 0.12) (4DOF) (p < 0.05). A loss of prescribed isodose coverage of 5% (SD, 0.08) was found with the 4DOF positioning (p < 0.05). Half a degree for longitudinal and lateral rotations can be identified as a threshold for coverage loss. Conclusions: With a mask immobilization, patient setup error and intrafraction motions need to be evaluated and corrected for. The 6DOF patient positioning with a 6DOF robotic couch to correct translational and rotational setup errors improves target positioning with respect to treatment isocenter, which is in direct relation with the clinical outcome, compared with the 4DOF positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Performance Improvements of the Prototype Open Core Flywheel Energy Storage System

A prototype magnetically suspended composite flywheel energy storage (FES) system is operating at the University of Maryland. This system, designed for spacecraft applications, incorporates recent advances in the technologies of composite materials, magnetic suspension, and permanent magnet brushless motor/generator. The current system is referred to as an Open Core Composite Flywheel (OCCF) energy storage system. This paper will present design improvements for enhanced and robust performance. Initially, when the OCCF prototype was spun above its first critical frequency of 4,500 RPM, the rotor movement would exceed the space available in the magnetic suspension gap and touchdown on the backup mechanical bearings would occur. On some occasions it was observed that, after touchdown, the rotor was unable to re-suspend as the speed decreased. Additionally, it was observed that the rotor would exhibit unstable oscillations when the control system was initially turned on. Our analysis suggested that the following problems existed: (1) The linear operating range of the magnetic bearings was limited due to electrical and magnetic saturation; (2) The inductance of the magnetic bearings was affecting the transient response of the system; (3) The flywheel was confined to a small movement because mechanical components could not be held to a tight tolerance; and (4) The location of the touchdown bearing magnifies the motion at the pole faces of the magnetic bearings when the linear range is crucial. In order to correct these problems an improved design of the flywheel energy storage system was undertaken. The magnetic bearings were re-designed to achieve a large linear operating range and to withstand load disturbances of at least 1 g. The external position transducers were replaced by a unique design which were resistant to magnetic field noise and allowed cancellation of the radial growth of the flywheel at high speeds. A central rod was utilized to ensure the concentricity of the magnetic bearings, the motor/generator, and the mechanical touchdown bearings. In addition, the mechanical touchdown bearings were placed at two ends of the magnetic bearing stack to restrict the motion at pole faces. A composite flywheel was made using a multi-ring interference assembled design for a high specific energy density. To achieve a higher speed and better efficiency, a permanent magnet DC brushless motor was specially designed and fabricated. A vacuum enclosure was constructed to eliminate windage losses for testing at high speeds. With the new improvements the OCCF system was tested to 20,000 RPM with a total stored energy of 15.9 WH and an angular momentum of 54.8 N-m-s (40.4 lb-ft-s). Motor current limitation, caused by power loss in the magnetic bearings, was identified as causing the limit in upper operating speed.

Pang, D.↗

High-resolution imaging with a tip-tilt Cassegrain secondary

A prototype adaptive secondary mirror has been developed on a 2.3-m telescope to stabilize rapid motion caused by atmospheric turbulence. The instantaneous position of an image's centroid, or brightest speckle, is measured by a near-infrared camera system which enables the tip-tilt mirror to recenter the image. Correction is accomplished at closed-loop frequencies of less than or = 100 Hz on guide stars with K (2.2 micrometers) magnitudes less than or = 8. Image motion is reduced to less than 0.1 sec rms, removing over 90% of low-frequency (f less than or = 5 Hz) tilt power, leaving less than or = 1 rad exp 2 mean square wave front tilt phase error. In seeing conditions where D/r sub o approximately = 4, long exposures in the H band (1.6 micrometers) exhibit a nearly diffraction-limited resolution of 0.19 sec full width at half maximum (FWHM) (Strehl ratio aprroximately = 0.14)-a factor of 4 improvement over uncorrected images. Reduction of the present static optical errors will improve the Strehl ratio another factor of 2, leading to approximately 70% of the maximum possible Strehl ratio.

Close, L. M.↗

Atmospheric gas dynamics in the Perseus cluster observed with Hitomi*

Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100 kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the hot gas is remarkably low and mostly uniform. The velocity dispersion reaches maxima of approximately 200 km s -1 toward the central active galactic nucleus (AGN) and toward the AGN inflated north-western ‘ghost’ bubble. Elsewhere within the observed region, the velocity dispersion appears constant around 100 km s -1 . We also detect a velocity gradient with a 100 km s -1 amplitude across the cluster core, consistent with large-scale sloshing of the core gas. If the observed gas motions are isotropic, the kinetic pressure support is less than 10%of the thermal pressure support in the cluster core. The well-resolved optically thin emission lines have Gaussian shapes, indicating that the turbulent driving scale is likely below 100 kpc, which is consistent with the size of the AGN jet inflated bubbles. We also report the first measurement of the ion temperature in the intracluster medium, which we find to be consistent with the electron temperature. In addition, we present a new measurement of the redshift to the brightest cluster galaxy NGC 1275.

79 ASTRONOMY AND ASTROPHYSICS↗

THE PROPER MOTION OF PALOMAR 5

Palomar 5 (Pal 5) is a faint halo globular cluster associated with narrow tidal tails. It is a useful system to understand the process of tidal dissolution, as well as to constrain the potential of the Milky Way. A well-determined orbit for Pal 5 would enable detailed study of these open questions. We present here the first CCD-based proper motion measurement of Pal 5 obtained using SDSS as a first epoch and new Large Binocular Telescope/Large Binocular Camera (LBC) images as a second, giving a baseline of 15 years. We perform relative astrometry, using SDSS as a distortion-free reference, and images of the cluster and also of the Pal 5 stream for the derivation of the distortion correction for LBC. The reference frame is made up of background galaxies. We correct for differential chromatic refraction using relations obtained from SDSS colors as well as from flux-calibrated spectra, finding that the correction relations for stars and for galaxies are different. We obtain μ{sub α} = −2.296 ± 0.186 mas yr{sup −1} and μ{sub δ} = −2.257 ± 0.181 mas yr{sup −1} for the proper motion of Pal 5. We use this motion, and the publicly available code galpy, to model the disruption of Pal 5 in different Milky Way models consisting of a bulge, a disk, and a spherical dark matter halo. Our fits to the observed stream properties (streak and radial velocity gradient) result in a preference for a relatively large Pal 5 distance of around 24 kpc. A slightly larger absolute proper motion than what we measure also results in better matches but the best solutions need a change in distance. We find that a spherical Milky Way model, with V{sub 0} = 220 km s{sup −1} and V{sub 20} {sub kpc}, i.e., approximately at the apocenter of Pal 5, of 218 km s{sup −1}, can match the data well, at least for our choice of disk and bulge parametrization.

79 ASTRONOMY AND ASTROPHYSICS↗

Column-by-column observation of dislocation motion in CdTe: Dynamic scanning transmission electron microscopy

The dynamics of partial dislocations in CdTe have been observed at the atomic scale using aberration-corrected scanning transmission electron microscopy (STEM), allowing the mobility of different dislocations to be directly compared: Cd-core Shockley partial dislocations are more mobile than Te-core partials, and dislocation cores with unpaired columns have higher mobility than those without unpaired columns. The dynamic imaging also provides insight into the process by which the dislocations glide. Dislocations with dangling bonds on unpaired columns are found to be more mobile because the dangling bonds mediate the bond exchanges required for the dislocations to move. Furthermore, a screw dislocation has been resolved to dissociate into a Shockley partial-dislocation pair along two different directions, revealing a way for the screw dislocation to glide in the material. The results show that dynamic STEM imaging has the potential to uncover the details of dislocation motion not easily accessible by other means. This research was sponsored by the U.S. DOE, Office of Energy Efficiency and Renewable Energy, Foundational Program to Advance Cell Efficiency (F-PACE, DE-FOA-0000492), (CL, YLW, NP, YFY, SJP), the Office of DOE-BES, Materials Science and Engineering Division (ARL), DOE Grant No. DE-FG02-09ER46554 (YYZ, STP), and a user project supported by ORNL's Center for Nanophase Materials Sciences (CNMS), which is also sponsored by DOE-BES. Supercomputer time was provided by the National Center for Supercomputing Applications which is supported by the DOE Office of Science under Contract No. DE-AC02-05CH11231, and the Extreme Science and Engineering Discovery Environment (XSEDE), which is supported by National Science Foundation Grant No. ACI-1053575. Chen Li [No. 656378] and Timothy Pennycook [No.655760] are currently funded by the European Union's Marie Sklodowska-Curie Grants.

36 MATERIALS SCIENCE↗

Simulating a numerical UV completion of quartic Galileons

The Galileon theory is a prototypical effective field theory that incorporates the Vainshtein screening mechanism—a feature that arises in some extensions of general relativity, such as massive gravity. The Vainshtein effect requires that the theory contain higher order derivative interactions, which results in Galileons, and theories like them, failing to be technically well posed. While this is not a fundamental issue when the theory is correctly treated as an effective field theory, it nevertheless poses significant practical problems when numerically simulating this model. These problems can be tamed using a number of different approaches: introducing an active low-pass filter and/or constructing a UV completion at the level of the equations of motion, which controls the high momentum modes. These methods have been tested on cubic Galileon interactions, and have been shown to reproduce the correct low-energy behavior. Here we show how the numerical UV-completion method can be applied to quartic Galileon interactions, and present the first simulations of the quartic Galileon model using this technique. We demonstrate that our approach can probe physics in the regime of the effective field theory in which the quartic term dominates, while successfully reproducing the known results for cubic interactions. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Influence of visual and motion cues on manual lateral stabilization

The ability of humans to detect and control their own lateral acceleration was measured by means of a closed-loop nulling task. Wide-field moving visual cues enhanced the operator's performance in nulling self-motion, especially at lower frequencies. Even visual cues, fixed relative to the operator, resulted in performance improvement relative to self-motion nulling in the dark. Describing function (frequency response) data was obtained for random acceleration conditions consisting of the visual field fixed relative to the laboratory, fixed relative to the subject, moving at constant velocity relative to the subject, and in the dark. The describing function data was corrected for the dynamics of operator manual control strategy. The resulting frequency responses were used to develop a linear model of self-motion detection which required a lead term of 1.5 rad/s to be added to the existing model in order to match the higher sensitivity at higher frequencies.

Huang, J.-K.↗

Model-Based Wavefront Control for CCAT

The 25-m aperture CCAT submillimeter-wave telescope will have a primary mirror that is divided into 162 individual segments, each of which is provided with 3 positioning actuators. CCAT will be equipped with innovative Imaging Displacement Sensors (IDS) inexpensive optical edge sensors capable of accurately measuring all segment relative motions. These measurements are used in a Kalman-filter-based Optical State Estimator to estimate wavefront errors, permitting use of a minimum-wavefront controller without direct wavefront measurement. This controller corrects the optical impact of errors in 6 degrees of freedom per segment, including lateral translations of the segments, using only the 3 actuated degrees of freedom per segment. The global motions of the Primary and Secondary Mirrors are not measured by the edge sensors. These are controlled using a gravity-sag look-up table. Predicted performance is illustrated by simulated response to errors such as gravity sag.

edge sensor↗