Verification of Doppler coherence imaging for 2D ion velocity measurements on DIII-D

Coherence Imaging Spectroscopy (CIS) has emerged as a powerful tool for investigating complex ion phenomena in the boundary of magnetically confined plasma devices. The combination of Fourier-transform interferometry and high-resolution fast-framing cameras has made it possible to make sensitive velocity measurements that are also spatially resolved. However, this sensitivity makes the diagnostic vulnerable to environmental effects including thermal drifts, vibration, and magnetic fields that can influence the velocity measurement. Additionally, the ability to provide an absolute calibration for these geometries can be impacted by differences in the light-collection geometry between the plasma and reference light source, spectral impurities, and the presence of thin-films on in-vessel optics. This work discusses the mitigation of these effects and demonstration that environmental effects result in less than 0.5 km/s error on the DIII-D CIS systems. A diagnostic comparison is used to demonstrate agreement between CIS and traditional spectroscopy once tomographic artifacts are accounted for.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asymmetrisation of the profile of a thin dynamic holographic grating in a TV-locked optical feedback loop

A system for recording a dynamic holographic grating in an optically addressed liquid-crystal spatial light modulator is studied. The system provides the asymmetrisation of the grating profile by using a TV-locked optical feedback loop (nonlinear or adaptive interferometer). (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smoothing of the spectrum of fibre Bragg gratings in the Lloyd-interferometer recording scheme

The possibility of apodization of fibre Bragg gratings (FBGs) recorded in the region of interference of the two parts of a Gaussian beam in a Lloyd interferometer is considered. The reflection spectra of FBGs are numerically simulated for different parameters of the recording beam and its displacement with respect to the dividing axis in the interferometer. Aconsiderable suppression of sidelobe resonances in the FBG spectrum during the displacement of the beam centre with respect to the dividing axis by half the beam radius is predicted and experimentally demonstrated. It is shown that this is caused by the equating of the mean value of the refractive index in the FBG region. (fibres)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acousto-optic gyrotropic-crystal-based modulator with a rotating polarisation vector

We study the influence of ellipticity of gyrotropic-crystal eigenwaves on the output characteristics of an acousto-optic (AO) modulator based on the interferometer scheme. The schemes of AO modulators are considered, which provide the polarisation vector rotation frequency fn /2, where f is the frequency of the acoustic wave, and n is the integer. Preference is given to the scheme combining cascade and polarisation-independent diffraction. An experimental layout of the AO modulator operating at f = 44.5 MHz is described, the modulation frequency of the output laser light intensity being 89 MHz. The frequency of the electrical signal from the photodetector is equal to 179.5 MHz. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband Laser Ranging: Signal Analysis and Interpretation

Broadband laser ranging (BLR) is essentially a spectral interferometer used to infer distance to a moving target. The light source is a mode-locked fiber laser, and chromatic dispersion maps the spectral interference pattern into the time domain, yielding chirped beat signals at the detector. A BLR record is a sequence of these chirped signals, representing consecutive target positions. To infer distance to a target, each underlying pulse envelope must be consistently registered and subtracted despite environmentally-induced variability. Then, nonlinear transformation of the phase is applied to remove the chirp, an FFT is performed to determine the peak frequency of the de-chirped signal, and a calibration factor relating de-chirped frequency to distance results in target position. This article discusses these analysis steps are in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

Using a Neural Network to Determine the Hatch Status of the AERI at the ARM North Slope of Alaska Site

The fore-optics of the Atmospheric Emitted Radiance Interferometer (AERI) are protected by an automated hatch to prevent precipitation from fouling the instrument's scene mirror (Knuteson et al. 2004). Limit switches connected with the hatch controller provide a signal of the hatch state: open, closed, undetermined (typically associated with the hatch being between fully open or fully closed during the instrument's sky view period), or an error condition. The instrument then records the state of the hatch with the radiance data so that samples taken when the hatch is not open can be removed from any subsequent analysis. However, the hatch controller suffered a multi-year failure for the AERI located at the ARM North Slope of Alaska (NSA) Central Facility in Barrow, Alaska, from July 2006-February 2008. The failure resulted in misreporting the state of the hatch in the 'hatchOpen' field within the AERI data files. With this error there is no simple solution to translate what was reported back to the correct hatch status, thereby making it difficult for an analysis to determine when the AERI was actually viewing the sky. As only the data collected when the hatch is fully open are scientifically useful, an algorithm was developed to determine whether the hatch was open or closed based on spectral radiance data from the AERI. Determining if the hatch is open or closed in a scene with low clouds is non-trivial, as low opaque clouds may look very similar spectrally as the closed hatch. This algorithm used a backpropagation neural network; these types of neural networks have been used with increasing frequency in atmospheric science applications.

47 OTHER INSTRUMENTATION↗

Cycle II.5 aircraft aero-optical turbulent boundary-layer/shear-layer measurements

The aero-optical effects associated with propagating a laser beam through aircraft turbulent boundary layers and shear layers were examined. Observed laser optical performance levels were compared with those inferred from aerodynamic measurements of unsteady densities and correlation lengths within these random flows. Optical instrumentation included a fast shearing interferometer (FSI). A 9 cm diameter collimated helium neon laser beam made a double pass through the aircraft random flow via an airfoil mirror located one meter from the fuselage. Typical aircraft turbulent boundary layer thickness measured 0.3 meters. Averaging many FSI generated modulation transfer functions (MTFs) and Fourier transforming, this average yields the expected far field intensity degradation associated with an aircraft mounted laser system. Aerodynamic instrumentation included fine wire probes to measure unsteady temperature and mass flux. A laser doppler velocimeter measured unsteady velocity within the flows. An analysis of these data yielded point measurements of unsteady density and correlation length.

Gilbert, K.↗

Interferometer Measures Broardband Surface Acoustic Waves

Dual differential interferometer uses two pairs of orthogonallypolarized optical beams to measure amplitude and orientation of broadband ultrasonic surface acoustic waves. Instrument modular, and sensitivity limited only by optical detector used.

Claus, R. O.↗

Investigation of thermospheric winds relative to space station orbital altitudes

An investigation of thermospheric winds, relative to the space station orbital altitudes, was made in order to provide information that is useful in an environmental disturbance assessment. Current plans are for this low Earth orbiting facility to orbit at an inclination of 28.5 deg. The orbital altitudes were not yet defined due to the evolutionary configuration of the Space Station. The upper and lower bounds of the orbital altitudes will be based on constraints set by the drag and expected orbital decay and delivery altitude capability of the Shuttle. The orbital altitude will be estimated on the order of 500 km. Neutral winds in the region from about 80 to 600 km which were derived from satellite drag data, Fabry-Perot interferometers, sounding rockets, ground-based optical Doppler techniques, incoherent scatter radar measurements from Millstone Hill combined with the mass spectrometer and lithium trail neutral wind measurements are examined. The equations of motion of the low Earth orbiting facility are also discussed.

Susko, M.↗

High spectral resolution lidar to measure optical scattering properties of atmospheric aerosols. II - Calibration and data analysis

The high spectral resolution lidar (HSRL) measures optical properties of atmospheric aerosols by interferometically separating the elastic aerosol backscatter from the Doppler broadened molecular contribution. Calibration and data analysis procedures developed for the HSRL are described. Data obtained during flight evaluation testing of the HSRL system are presented with estimates of uncertainties due to instrument calibration. HSRL measurements of the aerosol scattering cross section are compared with in situ integrating nephelometer measurements.

Sroga, J. T.↗

Improved Skin Friction Interferometer

An improved system for measuring aerodynamic skin friction which uses a dual-laser-beam oil-film interferometer was developed. Improvements in the optical hardware provided equal signal characteristics for each beam and reduced the cost and complexity of the system by replacing polarization rotation by a mirrored prism for separation of the two signals. An automated, objective, data-reduction procedure was implemented to eliminate tedious manual manipulation of the interferometry data records. The present system was intended for use in two-dimensional, incompressible flows over a smooth, level surface without pressure gradient, but the improvements discussed are not limited to this application.

Westphal, R. V.↗

On the role of convective motion during dendrite growth: Experiments under variable gravity, revised

Experiments show the effect of self induced convection on individual dendrite growth in uniformly supercooled samples and solidification of the resulting mush under conditions of high and low g. Convection is visualized by a Schlieren optical system or a Mach Zender interferometer. For ice crystals growing from the vapor in air, a slight reduction in linear growth rate occur under low g. For ice crystals growing from NaCl solution, dendrite tip velocities are unchanged, but subsequent mush solidification is enhanced through drainage channels under higher g. By contrast, sodium sulfate decahydrate dendrites growing from solution produce convective plumes which lead to higher tip growth rate only as the crystal growth direction approaches that of gravity. Convective plumes are laminar for small crystals under conditions of these experiments; the rise velocity of such plumes is greater than individual vortex rings under identical conditions. Convection effects are only present in solution under a critical supercooling less than about 5 C for sodium sulfate and 2 C for ice in NaCl since at higher supercooling the crystallization velocity, proportional to the square of the supercooling, exceeds the convective velocity, proportional to the square root of the supercooling. The role of convective velocity in bulk solidification is to give a large scale flow which under extreme cases may lead to extensive secondary crystal production, which alters the resulting crystal texture of the completely solidified melt.

Hallett, J.↗

Compact in-line laser radial shear interferometer

A compact in-line radial shearing interferometer using laser as a light source is presented. The interferometer is made out of a cube-type beam splitter so that the two opposite surfaces are generated with different curvatures while the normal to the entrance and exit surfaces are in the same line. The interferometer is simple to make and easy to align. Aberration analysis of the interferometer is also presented. Some applications of the interferometer for testing lenses and infrared optical systems and for accessing the quality of an emerging wave front from the exit slit of a monochromator are suggested.

Shukla, R. P.↗

Optical design and testing of a fast, large aperture, infrared space telescope

An optical design study for a next generation infrared space telescope has been performed. The concept is that of a passively cooled telescope of minimum aperture 2.5 m with an F/1.2 primary and wavelength coverage from 2 to as least 40 microns, and possibly to 100 microns. Compactness, low thermal emission from the optics and structure, diffraction limited imaging at 2 microns, and sensitivity to misalignment aberrations and manufacturing errors were the main considerations for this study. Ray tracing results are presented showing the characteristics of the various designs considered. A preliminary investigation of stray light properties is also given. Special emphasis has been placed on the testing of such a fast primary, and optical systems using a lateral shearing interferometer are described for testing both the primary and the primary/secondary combination.

Humphries, C. M.↗

Cryogenic optical systems and instruments V; Proceedings of the Meeting, San Diego, CA, July 23, 24, 1992

Topics discussed in this volume include cryogenic system design and optical technology; cryogenic instruments; cryogenic/IR mechanisms, testing, and performance; and space cryogenic dewars and coolers. Papers included are on the SIRTF cryooptics technology plan, the development of the SPIRIT III sensor, the design of a rapidly cooled cryogenic mirror, the cryogenic Michelson interferometer on the Space Shuttle, a reflective optical system for a hemispherical field radiometer, and infrared filters for cryogenic radiometers. Attention is also given to the development of a variable-profile scan mirror mechanism, a direct-drive digitally commutated filter wheel positioning system for cryogenic optical applications, a high-performance chopping secondary mirror for infrared astronomy, recent developments in compressor-based Joule-Thomson cooling, a radiative cryogenic cooler for the pressure modulator IR radiometer, and SIRTF thermal design modifications to increase lifetime.

Melugin, Ramsey K.↗

Pushing the limits of spatial resolution with the Kuiper Airborne observatory

The study of astronomical objects at high spatial resolution in the far-IR is one of the most serious limitations to our work at these wavelengths, which carry information about the luminosity of dusty and obscured sources. At IR wavelengths shorter than 30 microns, ground based telescopes with large apertures at superb sites achieve diffraction-limited performance close to the seeing limit in the optical. At millimeter wavelengths, ground based interferometers achieve resolution that is close to this. The inaccessibility of the far-IR from the ground makes it difficult, however, to achieve complementary resolution in the far-IR. The 1983 IRAS survey, while extraordinarily sensitive, provides us with a sky map at a spatial resolution that is limited by detector size on a spatial scale that is far larger than that available in other wavelengths on the ground. The survey resolution is of order 4 min in the 100 micron bandpass, and 2 min at 60 microns (IRAS Explanatory Supplement, 1988). Information on a scale of 1' is available on some sources from the CPC. Deconvolution and image resolution using this database is one of the subjects of this workshop.