Search NASA⌕ Search

SEARCH · Search NASA

Results for “orientation distribution function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Effects of temperature and near-substrate plasma density on the structural and electrical properties of dc sputtered germanium thin films

Germanium thin films were deposited by dc reactive magnetron sputtering as a function of substrate temperature and ion flux using an unbalanced magnetron with an external magnetic field. The ion flux and energy distribution were measured using a retarding field energy analyzer (RFEA), a flat probe with a guard ring, and cylindrical Langmuir probes. The RFEA ion flux, the flat probe saturation currents, and the ion densities inferred from the cylindrical probe data are in very good agreement over a wide range of plasma densities, which were varied both by the external coil current and discharge power. The RFEA ion energy distributions are in good agreement with the plasma potentials inferred from the cylindrical probes, and suggest that the nonuniformity of the plasma in the vicinity of the substrate holder should be considered in the interpretation of probe results in these systems. The deposited films were characterized by x-ray diffraction, Raman spectroscopy, optical transmission, resistivity, and Hall effect measurements. Under low ion bombardment conditions, an abrupt onset of the crystalline phase with respect to temperature is observed in the Raman and x-ray diffraction measurements, and the crystal quality increases with increasing temperature above the transition temperature. The transition is also accompanied by a sharp decrease in film resistivity. The microcrystalline films have a strong preferential orientation in the (220) direction, and are p type with carrier densities in the range 10{sup 18} cm{sup -3} and mobilities in the range 15-30 cm{sup 2}/V-s. The structural and electronic properties of the films are sensitive to the ion flux. Near the transition temperature the effects of increasing ion flux can be attributed to the small temperature rise that accompanies the higher plasma density. At higher temperatures the increased ion flux results in a more random crystallographic orientation, with significantly lower carrier concentrations and only slightly lower carrier mobilities, implying either a reduction in acceptor defect density and/or the creation of compensating n-type defects.

36 MATERIALS SCIENCE↗

TU-EF-207-00: Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-01: Introductory Remarks on Recent Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-02: Spectral Mammography Based on Photon Counting Detectors

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-05: Dedicated Cone-beam Breast CT

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Extremum seeking with bounded update rates

In this work, we present a form of extremum seeking (ES) in which the unknown function being minimized enters the system’s dynamics as the argument of a cosine or sine term, thereby guaranteeing known bounds on update rates and control efforts. We present general n-dimensional optimization and stabilization results as well as 2D vehicle control, with bounded velocity and control efforts. For application to autonomous vehicles, tracking a source in a GPS denied environment with unknown orientation, this ES approach allows for smooth heading angle actuation, with constant velocity, and in application to a unicycle-type vehicle results in control ability as if the vehicle is fully actuated. Our stability analysis is made possible by the classic results of Kurzweil, Jarnik, Sussmann, and Liu, regarding systems with highly oscillatory terms. In our stability analysis, we combine the averaging results with a semi-global practical stability result under small parametric perturbations developed by Moreau and Aeyels.

97 MATHEMATICS AND COMPUTING↗

l3d2vtk: An MCNPTools Utility to Enable LNK3DNT File Visualization & Post-Processing

This paper describes recent work to develop and incorporate a utility program into the MCNPTools package that enables LNK3DNT file visualization & post-processing. A LNK3DNT file is a binary Cartesian, cylindrical, or spherical structured mesh file that describes material and material relative density distributions by mesh voxel. This mesh file format is principally used by the PARTISN discrete-ordinates radiation-transport code. However, the MCNP ® Monte Carlo radiation-transport code can use LNK3DNT files to specify geometry, and the MCNP code can produce LNK3DNT files representing a user-defined region of the MCNP constructive solid geometry (CSG). Because of the use of LNK3DNT files as MCNP input and output and with other computer codes, improving the ability to visualize and/or quantitatively post-process LNK3DNT files benefits end users. In particular, it is helpful to visually verify that the material and density distributions are as expected. Also, an analyst can orient viewers with respect to other in formation, e.g., by co-plotting a voxelized representation of MCNP CSG with mesh tally and/or particle track results. However, until now, the only capability to interactively interrogate LNK3DNT files is through a 2-D slice plotter provided by the Monte Carlo Application ToolKit (MCATK), which is not currently distributed outside of Los Alamos National Laboratory. The utility created as part of this work converts LNK3DNT binary files to an ASCII XML-based StructuredMesh VTK (.vts) file. The geometries supported are 1-D spherical and cylindrical ( r ), 1-D Cartesian ( x ), 2-D cylindrical ( r-z and r-θ ) and Cartesian ( x-y ), and 3-D cylindrical ( r-z-θ ) and Cartesian ( x-y-z ). This file format is chosen to minimize external dependencies (e.g., on an HDF5 library) and to provide a file that can be interrogated by the user in a text editor or standard visualization applications (e.g., ParaView or VisIt). However, other file formats may provide more utility such as XDMF, which can use HDF5 and is discussed further as something to explore as future work. This paper is organized as follows: a brief introduc tion to the MCNPTools library and utility programs is given, the LNK3DNT-to-VTK (l3d2vtk) utility functionality is de scribed, and then an example post-processing workflow using the ParaView application is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spherulitic Growth of Coral Skeletons and Synthetic Aragonite: Nature’s Three-Dimensional Printing

Coral skeletons were long assumed to have a spherulitic structure, that is, a radial distribution of acicular aragonite (CaCO 3 ) crystals with their c-axes radiating from series of points, termed centers of calcification (CoCs). This assumption was based on morphology alone, not on crystallography. In this paper, we measure the orientation of crystals and nanocrystals and confirm that corals grow their skeletons in bundles of aragonite crystals, with their c-axes and long axes oriented radially and at an angle from the CoCs, thus precisely as expected for feather-like or “plumose” spherulites. Furthermore, we find that in both synthetic and coral aragonite spherulites at the nanoscale adjacent crystals have similar but not identical orientations, thus demonstrating by direct observation that even at nanoscale the mechanism of spherulite formation is non-crystallographic branching (NCB), as predicted by theory. Finally, synthetic aragonite spherulites and coral skeletons have similar angle spreads, and angular distances of adjacent crystals, further confirming that coral skeletons are spherulites. This is important because aragonite grows anisotropically, 10 times faster along the c-axis than along the a-axis direction, and spherulites fill space with crystals growing almost exclusively along the c-axis, thus they can fill space faster than any other aragonite growth geometry, and create isotropic materials from anisotropic crystals. Greater space filling rate and isotropic mechanical behavior are key to the skeleton’s supporting function and therefore to its evolutionary success. Finally, in this sense, spherulitic growth is Nature’s 3D printing.

36 MATERIALS SCIENCE↗

Water Management In PEM Fuel Cell -“ A Lattice-Boltzmann Modeling Approach

In Proton Exchange Membrane Fuel Cells (PEMFCs), water management and the effective transport of water through the gas-diffusion-layer (GDL) are key issues for improved performance at high power density and for durability during freeze-thaw cycles. The diffusion layer is a thin (~150-350{micro}m), porous material typically composed of a web of carbon fibers and particles, and is usually coated with hydrophobic Teflon to remove the excess water through capillary action. In-situ diagnostics of water movement and gas-reactant transport through this thin opaque substrate is challenging. Numerical analyses are typically based on simplified assumptions, such as Darcy's Law and Leverett functions for the capillary pressure. The objective of this work is to develop a high fidelity CFD modeling and analysis tool to capture the details of multiphase transport through the porous GDL. The tool can be utilized to evaluate GDL material design concepts and optimize systems based on the interactions between cell design, materials, and operating conditions. The flow modeling is based on the Lattice Boltzmann Method (LBM). LBM is a powerful modeling tool to simulate multiphase flows. Its strength is in its kinetic theory based foundation, which provides a fundamental basis for incorporating intermolecular forces that lead to liquid-gas phase separation and capillary effects without resorting to expensive or ad-hoc interface reconstruction schemes. At the heart of the solution algorithm is a discrete form of the well-known Boltzmann Transport Equation (BTE) for molecular distribution, tailored to recover the continuum Navier-Stokes flow. The solution advances by a streaming and collision type algorithm, mimicking actual molecular physics, which makes it suitable for porous media involving complex boundaries. We developed a numerical scheme to reconstruct various porous GDL microstructures including Teflon loading. Single and multiphase LBM models are implemented to compute permeability. Predicted values are in good agreement with measured data. The present modeling approach resolves the GDL microstructures and captures the influence of fiber orientation on permeability and the influence of Teflon loading on the development of preferential flow paths through the GDL. These observations can potentially guide the development of novel GDL materials designed for efficient removal of water.

30 DIRECT ENERGY CONVERSION↗

Statistical evaluation of microscale stress conditions leading to void nucleation in the weak shock regime

Here, we investigate the heterogeneity of the stress state driven by anisotropic deformation response at the single crystal level through five statistical volume element (SVE) calculations of polycrystalline BCC tantalum. This work focuses on grain boundaries as a prominent material defect type prone to void nucleation based upon experimental observations of predominantly intergranular void nucleation in this material. The SVEs are constructed to be statistically representative of larger volumes of material and are meshed such that mean and standard deviation of grain size and orientation information is reconstructed. The computational meshes feature hexahedral (brick) elements and smooth conformal grain boundaries where significant stress concentration is known to occur, a tail effect of interest in the extreme events process of dynamic ductile damage. An existing micromechanical crystallographic plasticity model shown to capture the single crystal behavior of BCC tantalum well is used to perform the polycrystal calculations. The model includes representation of the non-Schmid effect of non-planar screw dislocation kinetics in tantalum. A three-dimensional stress state time profile predicted by damage modeling of a flyer plate impact experiment is applied as boundary conditions to each SVE. Resulting grain boundary stress state statistics are strongly non-Gaussian. Significant structural evolution is observed within the compressive hold before unloading into tension in the stress profile. Strong angular dependence of grain boundary traction magnitude with shock direction is observed. Non-Schmid effects continue to suggest their influence on propensity of microstructural defect types to nucleate voids. A general void nucleation criterion is proposed using probability theory. The general framework is specified to polycrystalline BCC tantalum in the weak shock regime to include the SVE calculations and literature molecular dynamics calculations of grain boundary void nucleation strength. Probability density functions (PDFs) are used to describe the interaction between the local stress state heterogeneity and the distributed grain boundary void nucleation strength state. A causation entropy maximization procedure removes the requirement for ad hoc selection of a PDF functional form and provides a rigorous procedure for data-based PDF determination. The resulting physically informed PDF describes the spatial appearance frequency of nucleated voids as a function of applied macroscale pressure. Lower length scale physics are thus packaged in a precise and computationally efficient way to provide computational plasticity insight to macroscale dynamic ductile damage models.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of initial breakdown phase for magnetised toroidal ICRF discharges

The radio-frequency (RF) plasma production technique in the ion cyclotron range of frequency (ICRF) attracts growing attention among fusion experts because of its high potential for solving several basic problems of reactor-oriented superconducting fusion machines, such as ICRF wall conditioning in tokamaks and stellarators (T{sub e} = 3−5eV, n{sub e}<10{sup 12}cm{sup −3}), ICRF-assisted tokamak start-up and target plasma production (n{sub e} = 10{sup 13}cm{sup −3}) in stellarators. Plasma initiation by ICRF has been studied intensively using single particle descriptions and basic analytic models. To further improve the present understanding on plasma production employing the vacuum RF field of ICRF antennas in toroidal devices in presence of the toroidal magnetic field, and its parametric dependencies a Monte Carlo code has been developed. The 1D code RFdinity1D describes the motion of electrons, accelerated by the RF field in front of the ICRF antenna, along one toroidal magnetic field line. Dependent on their individual energies and the related electron collision cross sections (ionisation, excitation and dissociation) weighted by a Monte Carlo procedure, an electron avalanche may occur. Breakdown conditions are discussed as function of RF discharge parameters (i) RF vacuum electric field strength, (ii) RF frequency and (iii) neutral pressure (H2). The slope of the exponential density increase, taken as measure for the breakdown speed, shows qualitative agreement to experimental breakdown times as found in literature and experimental data of the ASDEX upgrade and TEXTOR tokamak, and is interpreted by studying the characteristic electron velocity distribution functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting mesoscale spectral thermal conductivity using advanced deterministic phonon transport techniques

We present a review, demonstration and simulation of phonon transport for the purposes of predicting materials performance at the mesoscale. We focus primarily on the development and implementation of a unified methodology to enable predictive heat transport. We report on the current state of the art as it pertains to deterministic phonon transport methodologies, discussing various topics concerning phonons. In application, we focus on the Self-Adjoint Angular Flux (SAAF) formulation of the Boltzmann transport equation for phonons, and develop the spatial, angular, and material property discretization required to accurately simulate the predictive physics of heat transport in dielectrics. We discuss thermal interfacial resistance and present our formulation of the diffuse mismatch model for simulating phonon interactions at internal boundaries. We have recently developed a deterministic, spectral phonon transport method for predicting effective thermal conductivity ($\kappa_{\textrm{eff}}$), using Bose-Einstein source terms coupled through an average material temperature. In this method, we introduce a closure term to the phonon transport system which acts as a redistribution function for the total energy of the system, and serves as a guide for the amount of non-equilibrium behavior occurring in the system. This method predicts thermal conductivity and equilibrium temperature distributions in homogeneous and heterogeneous materials using data generated by ab initio density functional theory methods. We employ polarization, density of states and full dispersion spectra to resolve thermal conductivity with numerous angular and spatial discretizations. Our implementation utilizes a Richardson iteration on a modified version of the phonon scattering source. The equations associated with this method are solved via a modification of traditional source iteration. We compare the performance of source iteration applied to an existing uncoupled, traditional SAAF method to our new method and comment on the iterative performance of each. We observe ballistic and diffusive phonon scattering as acoustic thickness of the domain changes, and are able to make comparisons between the accuracy and efficiency of both methods.

36 MATERIALS SCIENCE↗

Hydrated goethite ([alpha]-FeOOH) (1 0 0 ) interface structure: Ordered water and surface functional groups

Goethite({alpha}-FeOOH), an abundant and highly reactive iron oxyhydroxide mineral, has been the subject of numerous studies of environmental interface reactivity. However, such studies have been hampered by the lack of experimental constraints on aqueous interface structure, and especially of the surface water molecular arrangements. Structural information of this type is crucial because reactivity is dictated by the nature of the surface functional groups and the structure or distribution of water and electrolyte at the solid-solution interface. In this study we have investigated the goethite (1 0 0) surface using surface diffraction techniques, and have determined the relaxed surface structure, the surface functional groups, and the three dimensional nature of two distinct sorbed water layers. The crystal truncation rod (CTR) results show that the interface structure consists of a double hydroxyl, double water terminated interface with significant atom relaxations. Further, the double hydroxyl terminated surface dominates with an 89% contribution having a chiral subdomain structure on the (1 0 0) cleavage faces. The proposed interface stoichiometry is ((H{sub 2}O)-(H{sub 2}O)-OH{sub 2}-OH-Fe-O-O-Fe-R) with two types of terminal hydroxyls; a bidentate (B-type) hydroxo group and a monodentate (A-type) aquo group. Using the bond-valence approach the protonation states of the terminal hydroxyls are predicted to be OH type (bidentate hydroxyl with oxygen coupled to two Fe{sup 3+} ions) and OH{sub 2} type (monodentate hydroxyl with oxygen tied to only one Fe{sup 3+}). A double layer three dimensional ordered water structure at the interface was determined from refinement of fits to the experimental data. Application of bond-valence constraints to the terminal hydroxyls with appropriate rotation of the water dipole moments allowed a plausible dipole orientation model as predicted. The structural results are discussed in terms of protonation and H-bonding at the interface, and the results provide an ideal basis for testing theoretical predictions of characteristic surface properties such as pK{sub a}, sorption equilibria, and surface water permittivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Expert system decision support for low-cost launch vehicle operations

Progress in assessing the feasibility, benefits, and risks associated with AI expert systems applied to low cost expendable launch vehicle systems is described. Part one identified potential application areas in vehicle operations and on-board functions, assessed measures of cost benefit, and identified key technologies to aid in the implementation of decision support systems in this environment. Part two of the program began the development of prototypes to demonstrate real-time vehicle checkout with controller and diagnostic/analysis intelligent systems and to gather true measures of cost savings vs. conventional software, verification and validation requirements, and maintainability improvement. The main objective of the expert advanced development projects was to provide a robust intelligent system for control/analysis that must be performed within a specified real-time window in order to meet the demands of the given application. The efforts to develop the two prototypes are described. Prime emphasis was on a controller expert system to show real-time performance in a cryogenic propellant loading application and safety validation implementation of this system experimentally, using commercial-off-the-shelf software tools and object oriented programming techniques. This smart ground support equipment prototype is based in C with imbedded expert system rules written in the CLIPS protocol. The relational database, ORACLE, provides non-real-time data support. The second demonstration develops the vehicle/ground intelligent automation concept, from phase one, to show cooperation between multiple expert systems. This automated test conductor (ATC) prototype utilizes a knowledge-bus approach for intelligent information processing by use of virtual sensors and blackboards to solve complex problems. It incorporates distributed processing of real-time data and object-oriented techniques for command, configuration control, and auto-code generation.

Szatkowski, G. P.↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

Formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

The formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗

Molecular Dynamics Simulations of Microstructural Effects on Austenite-Martensite Interfaces in NiTi

Formation and migration of austenite-martensite interfaces plays the key role in reversible martensitic transformations of shape memory alloys (SMAs). How these interfaces interact with the SMA microstructure is a primary determining factor in important functional properties such as hysteresis and transformation span. As such, successful microstructural engineering of SMAs requires in-depth knowledge of interface behavior. The rapid nature of martensitic transformations makes experimental observations of moving austenite-martensite interfaces challenging. Molecular dynamics (MD) simulation is a unique tool which can probe the atomic-scale details of austenite-martensite interfaces as they migrate through different microstructures. However, in focusing on the entire transformation process, including the nucleation of new phases, MD studies are usually performed so far from equilibrium that their relevance to experiment is questionable. Here, we demonstrate new MD techniques to generate energetically preferred austenite-martensite interfaces in NiTi under near-equilibrium conditions. The interfaces are semi-coherent, exhibiting a series of structural disconnections, and they can migrate rapidly through single crystals under only small thermodynamic driving forces. In contrast, when interfaces migrate in polycrystals, their motion is impeded by thermoelastic effects as well as changes in orientation relationships at grain boundaries. Microstructures which accumulate large amounts of elastic energy tend to release some fraction through irreversible, hysteresis-inducing mechanisms. We demonstrate that engineering microstructures with less constraints is a viable strategy to produce SMAs with reduced hysteresis and transformation span. Similar thermoelastic and hysteresis-inducing mechanisms also arise when austenite-martensite interfaces encounter precipitates and can be controlled by tuning characteristics of the precipitate distribution.

Gabriel Plummer↗