Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Sculpt test problem analysis.

This report details Sculpt's implementation from a user's perspective. Sculpt is an automatic hexahedral mesh generation tool developed at Sandia National Labs by Steve Owen. 54 predetermined test cases are studied while varying the input parameters (Laplace iterations, optimization iterations, optimization threshold, number of processors) and measuring the quality of the resultant mesh. This information is used to determine the optimal input parameters to use for an unknown input geometry. The overall characteristics are covered in Chapter 1. The speci c details of every case are then given in Appendix A. Finally, example Sculpt inputs are given in B.1 and B.2.

Sweetser, John David↗

Using Ultrasonics to Optimize the Processing Parameters of Thermoset Polymers [Slides]

Ultrasonics is used as a non-destructive evaluation method to improve our understanding of polymers. Coupling ultrasonics and FTIR can help determine which bonds are more relevant to the mechanical properties of the polymer. Modeling the cure kinetics can determine if the curing process of a sample deviates from the baseline. Cure kinetics influence the final chemical structure of the polymer. This method opens a new pathway to design and adapt polymers for high demanding applications.

36 MATERIALS SCIENCE↗

Systems and methods for estimation and prediction of battery health and performance

Systems and computer-implemented methods are used for analyzing battery information. The battery information may be acquired from both passive data acquisition and active data acquisition. Active data may be used for feature extraction and parameter identification responsive to the input data relative to an electrical equivalent circuit model to develop geometric-based parameters and optimization-based parameters. These parameters can be combined with a decision fusion algorithm to develop internal battery parameters. Analysis processes including particle filter analysis, neural network analysis, and auto regressive moving average analysis can be used to analyze the internal battery parameters and develop battery health metrics. Additional decision fusion algorithms can be used to combine the internal battery parameters and the battery health metrics to develop state-of-health estimations, state-of-charge estimations, remaining-useful-life predictions, and end-of-life predictions for the battery.

97 MATHEMATICS AND COMPUTING↗

Device for optimization of experimental parameters on synchrotron beam lines

Enhanced methods and a device enabling a plurality of tools for implementing a plurality of procedures for the accurate alignment and calibration of multiple components of the experimental set up at a synchrotron beam line are provided. The device includes an alignment pin or needle for centering a sample rotation axis. The device includes a YAG crystal for visualization of the beam and beam alignment and a metal foil for transmission or fluorescence measurements used for the monochromator calibration. The same, or different foils, or powders, or polymers, can be used for obtaining powder rings for finding the direct beam coordinates, for centering the beamstop on the direct beam and for calibration of the sample-to-detector distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An optimization-based approach to parameter learning for fractional type nonlocal models

Nonlocal operators of fractional type are a popular modeling choice for applications that do not adhere to classical diffusive behavior; however, one major challenge in nonlocal simulations is the selection of model parameters. In this study we propose an optimization-based approach to parameter identification for fractional models with an optional truncation radius. We formulate the inference problem as an optimal control problem where the objective is to minimize the discrepancy between observed data and an approximate solution of the model, and the control variables are the fractional order and the truncation length. For the numerical solution of the minimization problem we propose a gradient-based approach, where we enhance the numerical performance by an approximation of the bilinear form of the state equation and its derivative with respect to the fractional order. Several numerical tests in one and two dimensions illustrate the theoretical results and show the robustness and applicability of our method.

97 MATHEMATICS AND COMPUTING↗

An optimization-based approach to parameter learning for fractional type nonlocal models

Nonlocal operators of fractional type are a popular modeling choice for applications that do not adhere to classical diffusive behavior; however, one major challenge in nonlocal simulations is the selection of model parameters. In this work we propose an optimization-based approach to parameter identification for fractional models with an optional truncation radius. We formulate the inference problem as an optimal control problem where the objective is to minimize the discrepancy between observed data and an approximate solution of the model, and the control variables are the fractional order and the truncation length. For the numerical solution of the minimization problem we propose a gradient-based approach, where we enhance the numerical performance by an approximation of the bilinear form of the state equation and its derivative with respect to the fractional order. Several numerical tests in one and two dimensions illustrate the theoretical results and show the robustness and applicability of our method.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-583: Optimizing the MLC Model Parameters for IMRT in the RayStation Treatment Planning System

Purpose: To optimize the MLC model parameters for IMRT in the RayStation v.4.0 planning system and for a Varian C-series Linac with a 120-leaf Millennium MLC. Methods: The RayStation treatment planning system models rounded leaf-end MLC with the following parameters: average transmission, leaf-tip width, tongue-and-groove, and position offset. The position offset was provided by Varian. The leaf-tip width was iteratively evaluated by comparing computed and measured transverse dose profiles of MLC-defined fields at dmax in water. The profile comparison was also used to verify the MLC position offset. The transmission factor and leaf tongue width were derived iteratively by optimizing five clinical patient IMRT QA Results: brain, lung, pancreas, head-and-neck (HN), and prostate. The HN and prostate cases involved splitting fields. Verifications were performed with Mapcheck2 measurements and Monte Carlo calculations. Finally, the MLC model was validated using five test IMRT cases from the AAPM TG119 report. Absolute gamma analyses (3mm/3% and 2mm/2%) were applied. In addition, computed output factors for MLC-defined small fields (2×2, 3×3, 4×4, 6×6cm) of both 6MV and 18MV were compared to those measured by the Radiological Physics Center (RPC). Results: Both 6MV and 18MV models were determined to have the same MLC parameters: 2.5% transmission, tongue-and-groove 0.05cm, and leaftip 0.3cm. IMRT QA analysis for five cases in TG119 resulted in a 100% passing rate with 3mm/3% gamma analysis for 6MV, and >97.5% for 18MV. With 2mm/2% gamma analysis, the passing rate was >94.6% for 6MV and >90.9% for 18MV. The difference between computed output factors in RayStation and RPC measurements was less than 2% for all MLCdefined fields, which meets the RPC's acceptance criterion. Conclusion: The rounded leaf-end MLC model in RayStation 4.0 planning system was verified and IMRT commissioning was clinically acceptable. The IMRT commissioning was well validated using guidance from the AAPMTG119 protocol.

60 APPLIED LIFE SCIENCES↗

Simultaneous Optimization of Crystal Plasticity Hardening Parameters

Crystal plasticity models relate macroscopic deformation behavior to the evolution of slip systems strength, but their parameterization is often non-unique, with multiple parameter sets being able to describe the same macroscopic behavior. To address this issue, the present work adopts a Bayesian optimization framework for the parameterization of face-centered cubic plasticity models while simultaneously considering multiple experimental datasets from the literature. For single crystal Cu, parameter optimization was guided by the tensile stress–strain curves along several crystallographic orientations, with an adequate fit being found for five orientations at once. While additional parameters allowed for the consideration of more physical mechanisms, like different slip system interaction strengths or misorientations inherent to the experimental data, the extra dimensionality was found to limit the efficiency of the global minimization procedure. For polycrystalline Ni, multiple grain sizes were considered together in a representative polycrystalline model, with the optimization able to reconcile the model with the data for three grain sizes at once. As meaningful interpretation of parameters relies on the uniqueness of their values, incorporating multiple datasets into this discerning parameterization procedure enables more robust prediction and application of crystal plasticity models.

36 MATERIALS SCIENCE↗

Optimizing Perovskite Thin‐Film Parameter Spaces with Machine Learning‐Guided Robotic Platform for High‐Performance Perovskite Solar Cells

Abstract Simultaneously optimizing the processing parameters of functional thin films remains a challenge. The design and utilization of a fully automated platform called SPINBOT is presented for the engineering of solution‐processed functional thin films. The SPINBOT is capable of performing experiments with high sampling variability through the unsupervised processing of hundreds of substrates with exceptional experimental control. Through the iterative optimization process enabled by the Bayesian optimization (BO) algorithm, the SPINBOT explores an intricate parameter space, continuously improving the quality and reproducibility of the produced thin films. This machine learning (ML)‐guided reliable SPINBOT platform enables the acceleration of the optimization process of perovskite solar cells via a simple photoluminescence characterization of films. As a result, this study arrives at an optimal film that, when processed into a solar cell in an ambient atmosphere, immediately yields a champion power conversion efficiency (PCE) of 21.6% with satisfactory performance reproducibility. The unsealed devices retain 90% of their initial efficiency after 1100 h of continuous operation at 60–65 °C under metal‐halide lamps. It is anticipated that the integration of robotic platforms with the intelligent algorithm will facilitate the widespread adoption of effective autonomous experimentation to address the evolving needs and constraints within the materials science research community.

14 SOLAR ENERGY↗

Analytical gradient-based optimization of CALPHAD model parameters

The calibration of CALPHAD (CALculation of PHAse Diagrams) models involves the solution of a very challenging high-dimensional multiobjective optimization problem. Traditional approaches to parameter fitting predominantly rely on gradient-free methods, which while robust, are computationally inefficient and often scale poorly with model complexity. In this work, we introduce and demonstrate a generalizable framework for analytic gradient-based optimization of the parameters of the CALPHAD model enabled by the recently formalized Jansson derivative technique. This method allows for efficient evaluation of gradients of thermodynamic properties at equilibrium with respect to model parameters, even in the presence of arbitrarily complex internal degrees of freedom. Leveraging these semi-analytic gradients, we employ the conjugate gradient (CG) method to optimize thermodynamic model parameters for four binary alloy systems: Cu-Mg, Fe-Ni, Cr-Ni, and Cr-Fe. Across all systems, CG achieves comparable or superior optimality relative to Bayesian ensemble Markov Chain Monte Carlo (MCMC) with improvements in computational efficiency ranging from one to three orders of magnitude. Furthermore, our results establish a new paradigm for CALPHAD assessments in which high fidelity data-rich model calibration becomes tractable using deterministic gradient-informed algorithms.

CALPHAD↗

Real-Time Nitrate Ion Monitoring with Poly(3,4-ethylenedioxythiophene) (PEDOT) Materials

Nitrate (NO 3 ) pollution in groundwater, caused by various factors both natural and synthetic, contributes to the decline of human health and well-being. Current techniques used for nitrate detection include spectroscopic, electrochemical, chromatography, and capillary electrophoresis. It is highly desired to develop a simple cost-effective alternative to these complex methods for nitrate detection. Therefore, a real-time poly (3,4-ethylenedioxythiophene) (PEDOT)-based sensor for nitrate ion detection via electrical property change is introduced in this study. Vapor phase polymerization (VPP) is used to create a polymer thin film. Variations in specific parameters during the process are tested and compared to develop new insights into PEDOT sensitivity towards nitrate ions. Through this study, the optimal fabrication parameters that produce a sensor with the highest sensitivity toward nitrate ions are determined. With the optimized parameters, the electrical resistance response of the sensor to 1000 ppm nitrate solution is 41.79%. Furthermore, the sensors can detect nitrate ranging from 1 ppm to 1000 ppm. The proposed sensor demonstrates excellent potential to detect the overabundance of nitrate ions in aqueous solutions in real time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autopilot for frequency-modulation atomic force microscopy

One of the most challenging aspects of operating an atomic force microscope (AFM) is finding optimal feedback parameters. This statement applies particularly to frequency-modulation AFM (FM-AFM), which utilizes three feedback loops to control the cantilever excitation amplitude, cantilever excitation frequency, and z-piezo extension. These loops are regulated by a set of feedback parameters, tuned by the user to optimize stability, sensitivity, and noise in the imaging process. Optimization of these parameters is difficult due to the coupling between the frequency and z-piezo feedback loops by the non-linear tip-sample interaction. Four proportional-integral (PI) parameters and two lock-in parameters regulating these loops require simultaneous optimization in the presence of a varying unknown tip-sample coupling. Presently, this optimization is done manually in a tedious process of trial and error. Here, we report on the development and implementation of an algorithm that computes the control parameters automatically. The algorithm reads the unperturbed cantilever resonance frequency, its quality factor, and the z-piezo driving signal power spectral density. It analyzes the poles and zeros of the total closed loop transfer function, extracts the unknown tip-sample transfer function, and finds four PI parameters and two lock-in parameters for the frequency and z-piezo control loops that optimize the bandwidth and step response of the total system. Implementation of the algorithm in a home-built AFM shows that the calculated parameters are consistently excellent and rarely require further tweaking by the user. The new algorithm saves the precious time of experienced users, facilitates utilization of FM-AFM by casual users, and removes the main hurdle on the way to fully automated FM-AFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗