Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Measurement of CP Violation in B Anti-B Mixing on the Recoil of Partially Reconstructed Anti-B0 to D* L- Anti-Nu/L Using Kaon Tags

After its formulation in 1960's the Standard Model of Fundamental Interactions has gone through an impressive series of successes, begun with the discovery of neutral weak currents [1] and the experimental observations of the massive carriers of weak interactions, the W ± and Z 0 bosons [2], [3]. High precision measurements performed at LEP and SLAC test the validity of the theory to an unprecedented level of accuracy and do not show any significant deviations with respect to the Standard Model predictions. One of the attractive features of the Standard Model is the description of the phenomena which violate the matter-antimatter symmetry (CP), and this violation uniquely depends (in the quark sector) on a weak phase in the matrix describing the couplings among different quark flavors. CP-violation was discovered in 1964 as a tiny effect in the mixing of the K 0 - $\bar{K}$ 0 system [12] but, after a few decades of study of the physics of K mesons, no strong confirmation of the Standard Model can be obtained on the mechanism which generates CP-violation. On the other hand the physics of B mesons is suitable for a pretty large number of measurements which can confirm or disprove this aspect of the theory. The main goal of the BABAR and Belle experiments physics program is to test the description of CP-violation and flavor physics mainly from the decays of B u and B d mesons. Soon after the beginning of data-taking in 1999, CP-violation was discovered in the interference between mixing and decay in the golden channel B 0 → J/Ψ}K 0 [17] [18], while in 2004 a large direct charge asymmetry was observed in the B 0 → K + π - channel [16]. There is a third kind of CP-violation which can be exhibited by the B d - $\bar{B}$ d system, the so called CP-violation in mixing. The Standard Model predicts this asymmetry to be small, possibly out of reach of current experiments, but several New Physics models contain new particles and couplings which can enhance it up to detectable levels. In this thesis we search for CP-violation in B d - $\bar{B}$ d mixing at the BABAR experiment. We reconstruct one of the two B mesons produced at the PEP-II electromagnetic collider using the partial reconstruction technique, while the flavor of the other B is inferred by the charge of a kaon identified among its decay products. Given the smallness of the physical asymmetry we want to measure, a crucial aspect of this analysis is the control of spurious charge asymmetries arising from the interaction of particles with the detector material. We accomplish this by using a control sample of charged kaons on the same data we use in our analysis. After a brief introduction of the theoretical framework and the phenomenology of the decays of B mesons at a B-factory (chapters 1 and 2), we will review in chapter 3 the current experimental results on this topic. We will then describe the characteristics of the collider and the experimental apparatus (chapter 4) used to perform our measurement. The available dataset and the event pre-selection techniques are treated in chapter 5, while the analysis method is discussed in detail in the following one. In chapters 7 and 8 the definitions of the probability density functions used to model each component of our sample are given and then they are tested in samples of simulated data. Toy and reweighted Monte Carlo data are used in chapter 9 to test the sensitivity of our fitting procedure to the physical parameters related to CP violation; chapter 10 discusses the possibility of modeling some of the components of our sample directly on the data. Finally the fit on the real data sample is described in chapter 11 and the treatment of systematic uncertainties is done in chapter 12, while the final result is given in chapter 13.

43 PARTICLE ACCELERATORS↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Ion thruster performance calibration.

The calibration of a typical 20-cm diameter ion thrustor was examined to determine performance penalties that must be assessed in projecting measured performance into a space environment. Four specific areas were investigated. These include (1) double ion content of the beam, (2) back ingestion from the vacuum facility, (3) beam spreading, and (4) propellant flow rate measurements. The double ion content was measured and found to be as high as 5.5% at an arc voltage of 35 volts. Back ingestion was observed to become significant above tank pressures of 6 microtorr. Beam spreading reduced effective thrust on the order of 2.5%.

Pawlik, E. V.↗

Real-World Quantum Sensors: Evaluating Resources for Precision Measurement

Quantum phenomena present in many experiments signify nonclassical behavior, but do not always imply superior performance. Quantifying the enhancement achieved from quantum behavior needs careful analysis of the resources involved. We analyze the case of parameter estimation using an optical interferometer, where increased precision can in principle be achieved using quantum probe states. Common performance measures are examined and some are shown to overestimate the improvement. For the simplest experimental case we compare the different measures and exhibit this overestimation explicitly. We give the preferred analysis of these experiments and calculate benchmark values for experimental parameters necessary to realize a precision enhancement. Our analysis shows that unambiguous real-world enhancements in optical quantum metrology with fixed photon number are yet to be attained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The MPI_T events interface: An early evaluation and overview of the interface

Understanding the behavior of parallel applications that use the Message Passing Interface (MPI) is critical for optimizing communication performance. Performance tools for MPI currently rely on the PMPI Profiling Interface or the MPI Tool Information Interface, MPI_T, for portably collecting information for performance measurement and analysis. While tools using these interfaces have proven to be extremely valuable for performance tuning, these interfaces only provide synchronous information, i.e., when an MPI or an MPI_T function is called. There is currently no option for collecting information about asynchronous events from within the MPI library. Here, we propose a callback-driven interface for event notification from MPI implementations. Our approach is integrated in the existing MPI_T interface and provides a portable API for tools to discover and register for events of interest. We implement our MPI_T Events interface in Open MPI and demonstrate its functionality and usability with a small logging tool (MEL) as well as an early integration into the comprehensive measurement infrastructure Score-P.

97 MATHEMATICS AND COMPUTING↗

Measurements of prompt radiation induced conductivity of alumina and sapphire

We performed measurements of the prompt radiation induced conductivity in thin samples of Alumina and Sapphire at the Little Mountain Medusa LINAC facility in Ogden, UT. Five mil thick samples were irradiated with pulses of 20 MeV electrons, yielding dose rates of 1E7 to 1E9 rad/s. We applied variable potentials up to 1 kV across the samples and measured the prompt conduction current. Analysis rendered prompt conductivity coefficients between 1E 10 and 1E 9 mho/m/(rad/s), depending on the dose rate and the pulse width for Alumina and 1E 7 to 6E 7 mho/m/(rad/s) for Sapphire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparisons of Force Measurement Methods for DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators with cylindrical exposed electrodes, as the electrode diameter decrease the force efficiencies increase much faster than a previously reported linear trend. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. Actuators with rectangular cross-section exposed electrodes do not show the same rapid increase at small thicknesses. We have also shown that the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Federated Machine Learning-Based Anomaly Detection System for Synchrophasor Network Using Heterogeneous Data Sets: Preprint

Synchrophasor technology is widely deployed in the energy management system to monitor the grid health at micro level and perform necessary corrective actions in real time; however, integrated phasor devices and data aggregators are exposed to several cybersecurity threats. This paper proposes a federated ML(FML)-based ADS to detect several data integrity attacks in the synchrophasor network. The proposed approach integrates the horizontal FML technique and consists of substation-based local models and a control center-based global model. The proposed methodology includes training local models using heterogeneous data sets that include network and grid information and updating the global model through multiple iterations by sharing model gradients. Finally, the trained global model is applied to identify cyberattacks, normal operation, and physical events. To validate the proof of concept, we used synthetic data sets generated by Mississippi State University and Oak Ridge National Laboratory for training and testing the classification models using the National Renewable Energy Laboratory's high performance computing resources. Our experimental results, computed through several performance measures, reveal that the proposed approach shows consistent performance during the binary, three-class, and multiclass classifications while ensuring privacy of synchrophasor data.

anomaly detection system↗

The Value of Regression Models in Determining Industrial Energy Savings

Determination of industrial facility energy savings is commonly undertaken to comply with legal requirements, meet sustainability goals, and quantify greenhouse gas emissions, cost savings, and as one way to demonstrate energy performance improvement per the requirements of an energy management system standard, such as ISO 50001. At their most basic level, energy savings are determined through a process of accounting for baseline and reporting period energy consumption followed by a calculation of energy savings as the difference in the levels of energy consumption between the two periods. The determination of industrial facility-wide energy savings can be undertaken in a wide variety of ways and in relation to energy performance improvement, energy savings can be expressed as any number of energy performance indicators (EnPIs). Energy savings values will vary depending upon if an absolute, intensity, or regression basis of calculation is selected for use. The use of one of the three basis of energy savings calculation will alter the relevance, meaning, and comparability of the resulting energy savings values To increase consistency in the determination of energy savings values, standards such as the International Performance Measurement and Verification Protocol (IPMVP), ISO 17747 – Determination of Energy Savings in Organization, and the U.S. Department of Energy (U.S. DOE) Superior Energy Performance (SEP) program Measurement and Verification Protocol (SEP M&V Protocol) have been published. Industrial facilities in the United States, Mexico, and Canada are certified to the U.S. DOE SEP program after becoming ISO 50001 certified and verification by a third party of calculated energy savings per the SEP M&V Protocol. This paper discusses some of the different meanings energy savings values will have when calculated by using the three different bases. Additionally, data from five SEP certified industrial facilities are used to calculate energy savings values using the three bases and compared as energy performance improvement percentage (EPI %) values. Discussion of why a large degree in variation in EPI % values are seen for any given set of data is provided. Ultimately, while each energy saving calculation basis has merit and can be used appropriately in its own context, the regression basis is shown to best translates energy savings values into contextualized energy performance improvement values by conveying comparable information regarding operational and behavioural improvements not otherwise observable with the absolute or intensity bases.

Therkelsen, Peter↗

SU-E-J-271: A Feasibility Study to Utilize XR-QA2 Radiochromic Films as An Alternative Tool for Measuring Beam Parameters of Kilovoltage CBCT Systems

Purpose: The beam parameters of the x-ray beams used in image guidance are difficult to measure in water due to the low exposure. This study is to investigate if XR-QA2 radiochromic films can be used in obtaining beam parameters, such as beam profiles and outputs for kV-CBCT systems. Methods: The kV-CBCT beams were from a Varian OBI system. The films used were XR-QA2-GAFCHROMICTM films placed in the middle of two Plastic -Water slab phantoms at isocenter. The scanner used to analyze the films was an Epson Expression 1680 flat-bed scanner. Pre and 24 h-post-irradiated scans of films were obtained by using the reflective mode. The corresponding pixel-by-pixel dose in the films was obtained using a dose calibration equation as a function of net reflectance from the literature. Beam profiles of different scan protocols with and without bow-tie filters were measured. Monte Carlo simulations were used to compare the accuracy of the measured dose profiles. Results: The beam profiles measured from XR-QA2 films for different clinical default kV-CBCT scan protocols were benchmarked against Monte Carlo simulated profiles which have been validated by measurements performed in water phantom. We confirmed that a minimum post-irradiated time of 24 hours is necessary to pass to scan the films to account for light scatter stability. We found that the uncertainties of the results depend on the scan orientation of the film when analyzed in different directions. Conclusion: The XR-QA2 radiochromic films are sensitive to measure the x-ray beam profiles with irradiated dose ranging 1–5 cGy. The film measurements can be performed with an easy setup compared to ion chamber measurements in a water phantom. These films provide an alternative method to obtain the beam profiles for kV-CBCT beams.

60 APPLIED LIFE SCIENCES↗

ThickBrick: optimal event selection and categorization in high energy physics. Part I. Signal discovery

We provide a prescription called ThickBrick to train optimal machine-learning-based event selectors and categorizers that maximize the statistical significance of a potential signal excess in high energy physics (HEP) experiments, as quantified by any of six different performance measures. For analyses where the signal search is performed in the distribution of some event variables, our prescription ensures that only the information complementary to those event variables is used in event selection and categorization. This eliminates a major misalignment with the physics goals of the analysis (maximizing the significance of an excess) that exists in the training of typical ML-based event selectors and categorizers. In addition, this decorrelation of event selectors from the relevant event variables prevents the background distribution from becoming peaked in the signal region as a result of event selection, thereby ameliorating the challenges imposed on signal searches by systematic uncertainties. Our event selectors (categorizers) use the output of machine-learning-based classifiers as input and apply optimal selection cutoffs (categorization thresholds) that are functions of the event variables being analyzed, as opposed to flat cutoffs (thresholds). These optimal cutoffs and thresholds are learned iteratively, using a novel approach with connections to Lloyd’s k-means clustering algorithm. We provide a public, Python implementation of our prescription, also called ThickBrick, along with usage examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of top quark mass measurements in CMS

The top quark mass is one of the most intriguing parameters of the standard model (SM). Its value indicates a Yukawa coupling close to unity, and the resulting strong ties to Higgs physics make the top quark mass a crucial ingredient for understanding essential aspects of the electroweak sector of the SM. This review offers the first comprehensive overview of the top quark mass measurements performed by the CMS Collaboration using the data collected at centre-of-mass energies of 7, 8, and 13 TeV. Moreover, a detailed description of the top quark event reconstruction is provided and dedicated studies of the dominant uncertainties in the modelling of the signal processes are discussed. The interpretation of the experimental results on the top quark mass in terms of the SM Lagrangian parameter is challenging and is a focus of an ongoing discussion in the theory community. The CMS Collaboration has performed two main types of top quark mass measurements, addressing this challenge from different perspectives: highly precise ‘direct’ measurements, based on reconstructed top quark decay products and relying exclusively on Monte-Carlo simulations, as well as ‘indirect’ measurements, where the simulations are employed to determine parton-level cross sections that are compared to fixed-order perturbative calculations. Recent mass extractions using Lorentz-boosted top quarks open a new avenue of measurements based on top quark decay products contained in a single particle jet, with promising prospects for accurate theoretical interpretations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation Evaluation of a Large-Scale Implementation of Virtual-Phase Link-Based Model Predictive Control

Traffic congestion is a serious problem in the US, and traffic signal control is one of the effective solutions to congestion. Previous research on model predictive control (MPC)-based traffic signal control showed substantial benefits over conventional methods. This study focused on implementing MPC over a large-scale network with complex intersections and the impact of cycle length, network size, and imperfect state estimation on performances. This study implemented a virtual phase link (VPL)-based model predictive control method which used the number of vehicles in each VPL as input state variables and was suitable for National Electrical Manufacturing Association (NEMA) ring-barrier control. To test the impact of network size, the performance of distributed MPC (36 intersections in the network are divided into five subnetworks) was compared with that of MPC over the full network for a set of cycle lengths. To test the impact of imperfect state estimation, we synthetically infused estimation error and developed two scenarios, MPC-error and MPC-error narrow, which had higher and lower estimation errors, respectively. The performance of these MPC methods was compared with that of the existing time-of-day (TOD) method and an offline method that used Webster's method for split and MULTIBAND for cycle length and offset optimization. Trajectory and linkwise signal performance measures were collected from the simulation to evaluate performance. The distributed MPC method with perfect state estimation had the lowest delay and highest energy efficiency of all the methods. The performance of MPC decreased as the prediction inaccuracy increased. MPC-error had 7% and 11% more delay than MPC-error narrow in the morning and evening peaks, respectively. Overall, simulation results suggest that even with imperfect state estimation, MPC methods will outperform offline methods significantly.

large-scale simulation↗

Real-time feedback control of a mesoscopic superposition

We show that continuous real-time feedback can be used to track, control, and protect a mesoscopic superposition of two spatially separated wave packets. The feedback protocol is enabled by an approximate state estimator and requires two continuous measurements, performed simultaneously. For nanomechanical and superconducting resonators, both measurements can be implemented by coupling the resonators to superconducting qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance and rotor loads measurements of the Lynx XZ170 helicopter with rectangular blades

This report presents the results of a series of flight tests on the Lynx XZ170 helicopter with rectangular blades. The test objectives were to explore the flight envelope and to measure the performance and structural loads of the Lynx main-rotor system. The tests were conducted as part of the British Experimental Rotor Program (BERP) under a contract with the Ministry of Defense in England. Data were acquired for steady-level flights at five weight coefficients. Some flight conditions were tested at beyond the retreating-blade stall boundary, which was defined by a predetermined limit on the pitchlink vibratory load. In addition to documenting the flight conditions and data, this report describes the aircraft, particularly the rotor system, in detail.

Lau, Benton H.↗