Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Considerations for autofocus of spotlight-mode SAR imagery created using a beamforming algorithm.

In recent papers the authors discussed the advantages of forming spotlight-mode SAR imagery from phase history data via a technique that is rooted in the principles of phased-array beamforming, which is closely related to back-projection. The application of a traditional autofocus algorithm, such as Phase Gradient Autofocus (PGA), requires some care in this situation. Specifically, a stated advantage of beamforming is that it easily allows for reconstruction of the SAR image onto an arbitrary imaging grid. One very useful grid, for example, is a Cartesian grid in the ground plane. Autofocus via PGA for such an image, however, cannot be performed in a straightforward manner, because in PGA a Fourier transform relationship is required between the image domain and the range-compressed phase history, and this is not the case for such an imaging grid. In this paper we propose a strategy for performing autofocus in this situation, and discuss its limitations. We demonstrate the algorithm on synthetic phase errors applied to real SAR imagery.

47 OTHER INSTRUMENTATION↗

FPGA-based Trigger System for the Fermilab SeaQuest Experimentz

The SeaQuest experiment (Fermilab E906) detects pairs of energetic μ + and μ - produced in 120 GeV/c proton–nucleon interactions in a high rate environment. The trigger system we used consists of several arrays of scintillator hodoscopes and a set of field-programmable gate array (FPGA) based VMEbus modules. Signals from up to 96 channels of hodoscope are digitized by each FPGA with a 1-ns resolution using the time-to-digital convertor (TDC) firmware. The delay of the TDC output can be adjusted channel-by-channel in 1-ns step and then re-aligned with the beam RF clock. The hit pattern on the hodoscope planes is then examined against pre-determined trigger matrices to identify candidate muon tracks. Finally, information on the candidate tracks is sent to the 2nd-level FPGA-based track correlator to find candidate di-muon events. The design and implementation of the FPGA-based trigger system for SeaQuest experiment are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure analysis of epitaxially grown self-assembled Ge islands on nanometer-scale patterned SiO{sub 2}/Si substrates by high-resolution transmission electron microscopy

The microstructure of epitaxially grown self-assembled Ge islands on patterned SiO{sub 2}/Si substrates was analyzed using high resolution transmission electron microscopy. The Ge islands were grown by molecular beam epitaxy on hexagonally ordered Si hole arrays with {approx}25 nm diameter and {approx}40 nm center-to-center distance, which are covered by 30 nm thick SiO{sub 2} mask layer patterned using self-assembled diblock copolymers. The Ge islands nucleate preferentially at the edge of overetched Si surface, and subsequently grow selectively on Si surface as opposed to SiO{sub 2} surface with increasing coverage. The lattice planes of some Ge islands are tilted from those of Si substrates. This is believed to be the reason for the observed misalignment of moire fringes. The diameter of the Ge islands is identical to that of Si holes for large Ge coverage due to the selective growth behavior. These islands are found to have dislocations at the interface with the Si substrate. These results highlight the important microstructural issues and growth behavior of quantum dots on patterned substrates.

36 MATERIALS SCIENCE↗

A Study of 13 Powerful Classical Double Radio Galaxies

We have carried out an extensive study of a sample of 13 large, powerful Fanaroff-Riley type II radio galaxies with the Very Large Array in multiple configurations at 330 MHz and 1.4, 5, and 8 GHz. We present the total intensity, polarization, spectral index, and rotation measure maps of the sources. On the whole, the 13 FR II sources have symmetric structures with arm-length ratios close to unity, small misalignment angles, and low values of radio core prominence, suggesting that these radio galaxies lie close to the plane of the sky. We have revisited some well-known radio galaxy correlations using a large combined data set comprising our radio galaxies and others from the literature. We confirm that the hot spot size correlates with the core-hot spot distance. The hot spot spectral index is correlated with and flatter than the lobe spectral index, consistent with the assumptions of spectral aging models. Both the hot spot and lobe spectral index are correlated with redshift. The depolarization asymmetry in the lobes is not correlated with the radio core prominence or misalignment angle, which are statistical indicators of orientation. The 'Liu-Pooley' correlation of lobe depolarization with the lobe spectral index is significant in our radio galaxy sample. Furthermore, the lobe with the steeper spectral index and greater depolarization is shorter and fatter. The arm-length ratio seems to be correlated with the misalignment angle between the two sides of the radio source and strongly anticorrelated with the axial ratio, consistent with environmental effects and/or a change in the outflow direction. In this sample, asymmetries in the local environments and/or motion of the outflow axis are likely to be more important than relativistic beaming effects.

79 ASTRONOMY AND ASTROPHYSICS↗

RADIO CONTINUUM OBSERVATIONS OF 47 TUCANAE AND {omega} CENTAURI: HINTS FOR INTERMEDIATE-MASS BLACK HOLES?

We present results of deep radio continuum observations of two galactic globular clusters 47 Tucanae (47 Tuc) and {omega} Centauri ({omega} Cen) with the Australia Telescope Compact Array. No statistically significant evidence for radio emission was found from the central region for the two clusters. However, both clusters show a 2.5{sigma} detection near the center that may be confirmed by future deeper radio observations. The 3{sigma} upper limits of the radio observations are 20 and 40 {mu}Jy beam{sup -1} for {omega} Cen and 47 Tuc, respectively. By using the fundamental plane of accreting black holes, which describes the relationship between radio luminosity, X-ray luminosity, and black hole mass, we constrain the mass of a possible intermediate-mass black hole (IMBH) in the globualar clusters. We also compare our results with other globular clusters and discuss the existence of IMBHs in globular clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculated and Measured Dose Distributions in an Anthropomorphic RANDO Phantom - Paper 105

Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Position-Sensitive Magnetic Calorimeter X-ray Detectors

We are developing arrays of position-sensitive magnetic calorimeter (PoSM) X-ray detectors for future astronomy missions. The PoSM consists of multiple absorbers thermally coupled to one magnetic sensor. Each absorber element has a different thermal coupling to the sensor. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. PoSMs are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels without compromising on spatial sampling. Optimizing the performance of PoSMs requires careful design of key parameters such as the thermal conductances between the absorbers, magnetic sensor and the heat sink, as well as the absorber heat capacities. We report on the first experimental results from four-absorber PoSMs, each absorber consisting of a two layer composite of bismuth and gold. The measured energy resolution (FWHM) was less than 5 eV for 6 keV X-rays into all four absorbers. Straightforward position discrimination by means of rise-time is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Damage Detection and Electrical Performance Impact of Flat-Flexible Circuits

Flat-flexible circuits or ‘flex circuits’ have varied applications in electronics and in explosive detonation systems. They pose advantages over conventional coaxial cables in their ability to fit into small mechanical envelopes and routings. A typical flex circuit is composed of a laminated assembly of multiple layers of conductor and dielectric materials. Copper, because of its high electrical conductivity, is one of the primary materials used in flex circuit conductors. The conductor must maintain structural integrity and electrical continuity when the flexible circuit is bent during processing or to fit an application envelope. Under some strain conditions a cable may have degraded electrical performance even though visible damage may not be evident. Dislocation density can increase by mechanisms such as dislocation forest hardening, where gliding dislocations in primary slip planes get pinned at obstacles and form Frank-Read sources. Dislocation density increases within the conductor layers may impact electrical resistivity but would not necessarily result in visible mechanical failure. In some detonation applications, such as for building implosion for demolition, the time for signal transmission and voltage used for firing detonators can be critical. If the resistance in a single flex cable within a building demolition array is too high, the resultant demolition shape may be asymmetric, leading to unplanned damage to nearby structures and potential hazards to public safety. This study will apply non-destructive evaluation techniques to evaluate the detectability of damage accumulation in flat, flexible copper-conductor cables and discuss potential implications to their practical use.

42 ENGINEERING↗

Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion with Validation from Mechanical Testing

Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the U.S. Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-in. IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer-diameter weld beads were removed for the microwave inspection. In two of the four pipes, both the outer and inner weld beads were removed and the pipe joints re-evaluated. The pipes were sectioned and the joints destructively evaluated with the side-bend test by cutting portions of the fusion joint into slices that were planed and bent. The last step in this limited study will be to correlate the fusion parameters, nondestructive, and destructive evaluation results to validate the effectiveness of what each NDE technology detects and what each does not detect. The results of the correlation will be used in identifying any future work that is needed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-scale dynamics of magnetic flux tubes and inverse magnetic energy transfer

Here, we report on an analytical and numerical study of the dynamics of a three-dimensional array of identical magnetic flux tubes in the reduced-magnetohydrodynamic description of the plasma. We propose that the long-time evolution of this system is dictated by flux-tube mergers, and that such mergers are dynamically constrained by the conservation of the pertinent (ideal) invariants, viz. the magnetic potential and axial fluxes of each tube. We also propose that in the direction perpendicular to the merging plane, flux tubes evolve in a critically balanced fashion. These notions allow us to construct an analytical model for how quantities such as the magnetic energy and the energy-containing scale evolve as functions of time. Of particular importance is the conclusion that, like its two-dimensional counterpart, this system exhibits an inverse transfer of magnetic energy that terminates only at the system scale. We perform direct numerical simulations that confirm these predictions and reveal other interesting aspects of the evolution of the system. We find, for example, that the early time evolution is characterized by a sharp decay of the initial magnetic energy, which we attribute to the ubiquitous formation of current sheets. We also show that a quantitatively similar inverse transfer of magnetic energy is observed when the initial condition is a random, small-scale magnetic seed field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of an LED Simulator for Single- and Multi-Junction PV Cell Performance Testing

We present the evaluation of a solar simulator comprising a Light Emitting Diode (LED) array as its light source. While multiple applications can be envisioned for such a light source, here we focus on its use for performance testing of solar cells at Standard Test Conditions. With this in mind, we present characterization of the spatial uniformity of the irradiance and its temporal stability as well as the spectral range and spectral class. For a multisource simulator, the spectral uniformity across the test plane should also be evaluated and we discuss a method for performing this evaluation that is well suited to a solar cell performance testing application. One major advantage of this simulator is the ability to easily adjust the spectral output as needed in multijunction PV cell measurements and we also discuss this application here.

LED↗

Swift and NuSTAR observations of GW170817: Detection of a blue kilonova

With the first direct detection of merging black holes in 2015, the era of gravitational wave (GW) astrophysics began. However, a complete picture of compact object mergers requires the detection of an electromagnetic (EM) counterpart. Here, we report ultraviolet (UV) and x-ray observations by Swift and the Nuclear Spectroscopic Telescope ARray (NuSTAR) of the EM counterpart of the binary neutron star merger GW 170817. The bright, rapidly fading ultraviolet emission indicates a high mass (≈ 0.03 solar masses) wind-driven outflow with moderate electron fraction (Ye ≈ 0.27). Combined with the x-ray limits, we favor an observer viewing angle of ≈30° away from the orbital rotation axis, which avoids both obscuration from the heaviest elements in the orbital plane and a direct view of any ultra-relativistic, highly collimated ejecta (a γ-ray burst afterglow).

79 ASTRONOMY AND ASTROPHYSICS↗

THE MAGNETIC FIELD MORPHOLOGY OF THE CLASS 0 PROTOSTAR L1157-mm

We present the first detection of polarization around the Class 0 low-mass protostar L1157-mm at two different wavelengths. We show polarimetric maps at large scales (10'' resolution at 350 {mu}m) from the SHARC-II Polarimeter and at smaller scales (1.''2-4.''5 at 1.3 mm) from the Combined Array for Research in Millimeter-wave Astronomy (CARMA). The observations are consistent with each other and show inferred magnetic field lines aligned with the outflow. The CARMA observations suggest a full hourglass magnetic field morphology centered about the core; this is only the second well-defined hourglass detected around a low-mass protostar to date. We apply two different methods to CARMA polarimetric observations to estimate the plane-of-sky magnetic field magnitude, finding values of 1.4 and 3.4 mG.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of underground gravity gradients from stochastic seismic fields

We present results obtained from a finite-element simulation of seismic displacement fields and of gravity gradients generated by those fields. The displacement field is constructed by a plane-wave model with a 3D isotropic stochastic field and a 2D fundamental Rayleigh field. The plane-wave model provides an accurate representation of stationary fields from distant sources. Underground gravity gradients are calculated as the acceleration of a free test mass inside a cavity. The results are discussed in the context of gravity-gradient noise subtraction in third generation gravitational-wave detectors. Error analysis with respect to the density of the simulated grid leads to a derivation of an improved seismometer placement inside a 3D array which would be used in practice to monitor the seismic field.

99 GENERAL AND MISCELLANEOUS↗

Method of fabricating a scalable nanoporous membrane filter

A method of fabricating a nanoporous membrane filter having a uniform array of nanopores etch-formed in a thin film structure (e.g. (100)-oriented single crystal silicon) having a predetermined thickness, by (a) using interferometric lithography to create an etch pattern comprising a plurality array of unit patterns having a predetermined width/diameter, (b) using the etch pattern to etch frustum-shaped cavities or pits in the thin film structure such that the dimension of the frustum floors of the cavities are substantially equal to a desired pore size based on the predetermined thickness of the thin film structure and the predetermined width/diameter of the unit patterns, and (c) removing the frustum floors at a boundary plane of the thin film structure to expose, open, and thereby create the nanopores substantially having the desired pore size.

36 MATERIALS SCIENCE↗

Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: In vivo evaluation under MR guidance

The purpose of this study was to explore the feasibility and performance of a multi-sectored tubular array transurethral ultrasound applicator for prostate thermal therapy, with potential to provide dynamic angular and length control of heating under MR guidance without mechanical movement of the applicator. Test configurations were fabricated, incorporating a linear array of two multi-sectored tubular transducers (7.8-8.4 MHz, 3 mm OD, 6 mm length), with three 120 deg. independent active sectors per tube. A flexible delivery catheter facilitated water cooling (100 ml min{sup -1}) within an expandable urethral balloon (35 mm longx10 mm diameter). An integrated positioning hub allows for rotating and translating the transducer assembly within the urethral balloon for final targeting prior to therapy delivery. Rotational beam plots indicate {approx}90 deg. - 100 deg. acoustic output patterns from each 120 deg. transducer sector, negligible coupling between sectors, and acoustic efficiencies between 41% and 53%. Experiments were performed within in vivo canine prostate (n=3), with real-time MR temperature monitoring in either the axial or coronal planes to facilitate control of the heating profiles and provide thermal dosimetry for performance assessment. Gross inspection of serial sections of treated prostate, exposed to TTC (triphenyl tetrazolium chloride) tissue viability stain, allowed for direct assessment of the extent of thermal coagulation. These devices created large contiguous thermal lesions (defined by 52 deg. C maximum temperature, t{sub 43}=240 min thermal dose contours, and TTC tissue sections) that extended radially from the applicator toward the border of the prostate ({approx}15 mm) during a short power application ({approx}8-16 W per active sector, 8-15 min), with {approx}200 deg. or 360 deg. sector coagulation demonstrated depending upon the activation scheme. Analysis of transient temperature profiles indicated progression of lethal temperature and thermal dose contours initially centered on each sector that coalesced within {approx}5 min to produce uniform and contiguous zones of thermal destruction between sectors, with smooth outer boundaries and continued radial propagation in time. The dimension of the coagulation zone along the applicator was well-defined by positioning and active array length. Although not as precise as rotating planar and curvilinear devices currently under development for MR-guided procedures, advantages of these multi-sectored transurethral applicators include a flexible delivery catheter and that mechanical manipulation of the device using rotational motors is not required during therapy. This multi-sectored tubular array transurethral ultrasound technology has demonstrated potential for relatively fast and reasonably conformal targeting of prostate volumes suitable for the minimally invasive treatment of BPH and cancer under MR guidance, with further development warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear oscillations of magnetization for ferromagnetic particles in the vortex state and their ordered arrays

The dynamics of magnetization oscillations with a considerable amplitude and a radial symmetry in small ferromagnetic particles in the form of a thin disk with a magnetic vortex has been investigated. The collective variables that describe radially symmetric oscillations of the magnetization dynamics for particles in the vortex state are introduced, and the dependence of the particle energy is studied as a function of these variables. The analytical expressions describing the frequency of magnetization oscillations with a radial symmetry, including nonlinear oscillations, are derived using the collective variables. It is shown that the presence of a magnetic field oriented perpendicular to the particle plane reduces the oscillation frequency and can lead to hybridization of this mode with other modes of spin oscillations, including the mode of translational oscillations of the vortex core. The soliton solutions describing the propagation of collective oscillations along the chain of magnetic particles are found.

36 MATERIALS SCIENCE↗