Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

A novel semi-structured kinetic model of methanotroph-photoautotroph cocultures for biogas conversion

Through metabolic coupling of methane oxidation and oxygenic photosynthesis, methanotroph-photoautotroph (M-P) cocultures offer a highly promising technology platform for biogas conversion. However, there has not been any quantitative modeling of the coculture growth kinetics. This is mainly due to the inherent difficulty associated with real time characterization of the M-P cocultures and the complex interactions such as the cross-feeding mechanism within the coculture. To address this challenge, we recently developed a novel experimental-computational (E-C) protocol to accurately characterize the M-P coculture in real-time, and validated its accuracy through cell counting. Enabled by the E-C protocol, this work presents the very first kinetic model for M-P cocultures. By explicitly modeling the exchange of in situ produced O 2 /CO 2 within the M-P coculture and coupling the individual biomass growth with mass transfer between the gas and liquid phases, the semi-structured kinetic model accurately predicts the growth dynamics of the M-P coculture under a wide range of growth conditions. The proposed model is validated by a series of wet-lab experiments using Methylomicrobium buryatense 5GB1 - Arthrospira platensis as the model coculture. Although it has been speculated that there may exist other emergent metabolic interactions within the M-P coculture, in addition to the exchange of in situ produced O 2 /CO 2 , there has not been any experimental validation prior to this study. By integrating designed experiments with the semi-structured kinetic model, this study is the first to confirm the existence of the additional emergent metabolic exchanges within the coculture. Furthermore, this study further quantifies the effect of these unknown metabolic interactions on the growth of both species in the model coculture, supporting further research to identify these exchanged metabolites for metabolic engineering.

42 ENGINEERING↗

Bright sub-20-nm cathodoluminescent nanoprobes for electron microscopy

Electron microscopy has been integral in our understanding of complex biological systems. Although electron microscopy reveals cellular morphology with nanoscale resolution, it does not provide information on the location of different types of proteins. An electron-microscopy-based bioimaging technology capable of localizing individual proteins and resolving protein-protein interactions with respect to cellular ultrastructure would provide important insights into the molecular biology of a cell. In this report, we synthesize small lanthanide-doped nanoparticles and measure the absolute photon emission rate of individual nanoparticles resulting from a given electron excitation flux (cathodoluminescence). Our results indicate that the optimization of nanoparticle composition, synthesis protocols and electron imaging conditions can lead to sub-20-nm nanolabels that would enable high signal-to-noise localization of individual biomolecules within a cellular context. In ensemble measurements, these labels exhibit narrow spectra of nine distinct colours, so the imaging of biomolecules in a multicolour electron microscopy modality may be possible.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Direct measurement of absorbed dose to water in HDR {sup 192}Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43

Purpose: Gafchromic film and ionometric calibration procedures for HDR {sup 192}Ir brachytherapy sources in terms of dose rate to water are presented and the experimental results are compared to the TG-43 protocol as well as with the absolute dose measurement results from a water calorimetry-based primary standard. Methods: EBT-1 Gafchromic films, an A1SL Exradin miniature Shonka thimble type chamber, and an SI HDR 1000 Plus well-type chamber (Standard Imaging, Inc., Middleton, WI) with an ADCL traceable S{sub k} calibration coefficient (following the AAPM TG-43 protocol) were used. The Farmer chamber and Gafchromic film measurements were performed directly in water. All results were compared to direct and absolute absorbed dose to water measurements from a 4 deg. C stagnant water calorimeter. Results: Based on water calorimetry, the authors measured the dose rate to water to be 361{+-}7 {mu}Gy/(h U) at a 55 mm source-to-detector separation. The dose rate normalized to air-kerma strength for all the techniques agree with the water calorimetry results to within 0.83%. The overall 1-sigma uncertainty on water calorimetry, ionization chamber, Gafchromic film, and TG-43 dose rate measurement amounts to 1.90%, 1.44%, 1.78%, and 2.50%, respectively. Conclusions: This work allows us to build a more realistic uncertainty estimate for absorbed dose to water determination using the TG-43 protocol. Furthermore, it provides the framework necessary for a shift from indirect HDR {sup 192}Ir brachytherapy dosimetry to a more accurate, direct, and absolute measurement of absorbed dose to water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

LCLS-II Cryomodule Production at JLAB

The LCLS-II cryomodule construction program leverages the mature XFEL cryomodule design to produce technologically sophisticated cryomodules with a minimum of R&D according to an accelerated manufacturing schedule. Jlab, as one of the partner labs, is producing 18 cryomodules for LCLS-II. To meet the quality and schedule demands of LCLS-II, many upgrades to the JLAB cryomodule assembly infrastructure and techniques have been made. JLab has installed a new cleanroom for string assembly and instituted new protocols to minimize particulate transfer into the cavities during the cryomodule construction process. JLab has also instituted a set of magnetic hygiene protocols to be used during the assembly process to minimize magnetic field impingement on the finished cavity structure. The goal has been to have gradients, both maximum and field emission onset, that do not degrade between the cavity vertical test and final cryomodule qualification, while maximizing the Q0 of each finished cavity. Results from the prototype and first production cryomodule assembly are presented.

Davis, Giles↗

Recommended Best Practices for the Characterization of Storage Properties of Hydrogen Storage Materials

These reports, written by H2 Technology Consulting under contract with the National Renewable Energy Laboratory, provides an introduction to and overview of the recommended best practices in making measurements of the hydrogen storage properties of materials. Sections 1-5 (published in February 2012), Section 6 (published in February 2013), and Section 7 (published in January 2016). The goal in developing this report was to create a reference guide of common methodologies and protocols for measuring critical performance properties of advanced hydrogen storage materials and to serve as a resource to the hydrogen storage materials development community to aid in clearly communicating the relevant performance properties of new materials as they are discovered and tested. Section 1: Introduction Section 2: Kinetics Measurements Section 3: Capacity Measurements Section 4: Thermodynamic Measurements Section 5: Cycle-Life Measurements Section 6: Thermal Properties Measurements Section 7: Mechanical Properties Measurements

08 HYDROGEN↗

Beyond microbial abundance: metadata integration enhances disease prediction in human microbiome studies

Multiple studies have highlighted the interaction of the human microbiome with physiological systems such as the gut, immune, liver, and skin, via key axes. Advances in sequencing technologies and high-performance computing have enabled the analysis of large-scale metagenomic data, facilitating the use of machine learning to predict disease likelihood from microbiome profiles. However, challenges such as compositionality, high dimensionality, sparsity, and limited sample sizes have hindered the development of actionable models. One strategy to improve these models is by incorporating key metadata from both the human host and sample collection/processing protocols. This remains challenging due to sparsity and inconsistency in metadata annotation and availability. In this paper, we introduce a machine learning-based pipeline for predicting human disease states by integrating host and protocol metadata with microbiome abundance profiles from 68 different studies, processed through a consistent pipeline. Our findings indicate that metadata can enhance machine learning predictions, particularly at higher taxonomic ranks like Kingdom and Phylum, though this effect diminishes at lower ranks. Our study leverages a large collection of microbiome datasets comprising 11,208 samples, therefore enhancing the robustness and statistical confidence of our findings. This work is a critical step toward utilizing microbiome and metadata for predicting diseases such as gastrointestinal infections, diabetes, cancer, and neurological disorders.

Mathematics and Computing↗

Real-time feedback control of a mesoscopic superposition

We show that continuous real-time feedback can be used to track, control, and protect a mesoscopic superposition of two spatially separated wave packets. The feedback protocol is enabled by an approximate state estimator and requires two continuous measurements, performed simultaneously. For nanomechanical and superconducting resonators, both measurements can be implemented by coupling the resonators to superconducting qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Ethernet Interface for NSTX-U’s Thomson Scattering Diagnostic (2023)

Here, the multipoint Thomson scattering (MPTS) diagnostic system at the National Spherical Torus Experiment Upgrade (NSTX-U) facility is undergoing an upgrade to operate in real-time and interface with the plasma control system (PCS) for NSTX-U. Previous prototyping efforts have shown that spectral analysis and rapid calculations of electron temperature and density are possible on a real-time Linux machine when using up to a 100-Hz laser pulse repetition rate. A remaining challenge was transferring the real-time data to NSTX-U’s PCS, which utilizes the front panel data port (FPDP) protocol. The original proposed method was to convert the real-time data into analog values, but a new solution was developed to keep the output format digital by using an Ethernet controller with a field-programmable gate array (FPGA). This article focuses on a new input module that has been developed to accept incoming user datagram protocol (UDP) packets sent over Ethernet, convert into FPDP format, and integrate into the existing data stream under NSTX-U’s real-time framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qumode transfer between continuous- and discrete-variable devices

Transferring quantum information between different types of quantum hardware is crucial for integrated quantum technology. In particular, converting information between continuous variable (CV) and discrete variable (DV) devices enables many applications in quantum networking, quantum sensing, quantum machine learning, and quantum computing. This paper addresses the transfer of CV-encoded information between CV and DV devices. We present a resource-efficient method for encoding CV states and implementing CV gates on DV devices, as well as two measurement-based protocols for transferring CV states between CV and DV devices. The success probability of the transfer protocols depends on the measurement outcome and can be increased to near-deterministic values by adding ancillary qubits to the DV devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric Bike Sharing--System Requirements and Operational Concepts

Bike sharing is an exciting new model of public-private transportation provision that has quickly emerged in the past five years. Technological advances have overcome hurdles of early systems and cities throughout the globe are adopting this model of transportation service. Electric bikes have simultaneously gained popularity in many regions of the world and some have suggested that shared electric bikes could provide an even higher level of service compared to existing systems. There are several challenges that are unique to shared electric bikes: electric-assisted range, recharging protocol, and bike and battery checkout procedures. This paper outlines system requirements to successfully develop and deploy an electric bike sharing system, focusing on system architecture, operational concepts, and battery management. Although there is little empirical evidence, electric bike sharing could be feasible, depending on demand and battery management, and can potentially improve the utility of existing bike sharing systems. Under most documented bike sharing use scenarios, electric bike battery capacity is insufficient for a full day of operation, depending on recharging protocol. Off-board battery management is a promising solution to address this problem. Off-board battery management can also support solar recharging. Future pilot tests will be important and allow empirical evaluation of electric bikesharing system performance. (auth)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Velocity measurement by coherent x-ray heterodyning

Herein, we present a small-angle coherent x-ray scattering technique used for measuring flow velocities in slow moving materials. The technique is an extension of X-ray Photon Correlation Spectroscopy (XPCS): It involves mixing the scattering from moving tracer particles with a static reference that heterodynes the signal. This acts to elongate temporal effects caused by flow in homodyne measurements, allowing for a more robust measurement of flow properties. Using coherent x-ray heterodyning, velocities ranging from 0.1 to 10 μm/s were measured for a viscous fluid pushed through a rectangular channel. We describe experimental protocols and theory for making these Poiseuille flow profile measurements and also develop the relevant theory for using heterodyne XPCS to measure velocities in uniform and Couette flows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molten Salt Corrosion Tests of Additively Manufactured Stainless Steel 316H

Molten salt reactors (MSRs) have drawn considerable interest due to their favorable safety features, high thermal efficiency, and compatibility with different fuel cycles. Yet, the success of MSRs hinges critically on the performance of structural materials to be used in these aggressive molten salt environments, where corrosion and material compatibility remain primary challenges to long-term reliability. Additively manufactured (AM) nuclear structural materials prompt the use of novel geometries and compositions to enhance material performance and reduce costs of constructing MSRs. The rapid solidification conditions inherent to AM processing impart distinctive microstructural features, including cellular sub-structures, dislocation densities, residual stress, and oxide inclusions, which can influence material performance in MSR components. While the mechanical properties of AM stainless steels have been widely studied, their corrosion behavior, particularly in molten salt environments, has received far less attention. Addressing these needs, the Advanced Materials and Manufacturing Technologies (AMMT) program provides a framework for systematically evaluating how unique microstructures produced by AM processes influence the performance of these materials in these demanding environments and for developing reproducible testing workflows that can support future code qualification efforts and standards development. Bridging this knowledge gap is essential for assessing the viability of AM alloys in MSRs and informing qualification strategies. A further challenge is the absence of standardized protocols for molten salt corrosion testing. Accordingly, this report provides an account of the corrosion evaluation of AM 316H stainless steel in NaCl 2 -MgCl 2 molten salt at 550 °C, with exposure times of 100 and 500 hours. It documents the experimental procedures implemented under the AMMT program, including salt preparation, exposure protocols, and post-test characterization methods, to establish reproducibility and transparency. Importantly, the study examines AM 316H samples in the as-fabricated condition, directly reflecting the surface state most relevant to engineering applications, and compares their behavior to machine-cut surfaces. Overall, preliminary evaluations have noted that surface conditions (e.g. morphology, contamination, etc.) have a noticeable impact on the corrosion resiliency. The impact of the corrosion is difficult to detect at 100h, unless, in the case of AM 316H, the specimen surface is decontaminated. After 500 h, as-fabricated surfaces of AM and wrought 316H display evidence of general versus preferential corrosion attack, respectively. Both AM and wrought 316H machine-cut surfaces exhibit a continuous Cr depletion zone, evident of general corrosion. While the estimated extent of corrosion appears within the same order of magnitude regardless of the surface condition, it is apparent that more predictable behavior is observed on machine-cut surfaces. Nonetheless, further investigation is necessary to fully elucidate the corrosion mechanism under these conditions.

36 - MATERIALS SCIENCE↗

Less Is More: Oligomer Extraction and Hydrothermal Annealing Increase PDMS Adhesion Forces for Materials Studies and for Biology-Focused Microfluidic Applications

Cues in the micro-environment are key determinants in the emergence of complex cellular morphologies and functions. Primary among these is the presence of neighboring cells that form networks. For high-resolution analysis, it is crucial to develop micro-environments that permit exquisite control of network formation. This is especially true in cell science, tissue engineering, and clinical biology. We introduce a new approach for assembling polydimethylsiloxane (PDMS)-based microfluidic environments that enhances cell network formation and analyses. We report that the combined processes of PDMS solvent-extraction and hydrothermal annealing create unique conditions that produce high-strength bonds between solvent-extracted PDMS (E-PDMS) and glass—properties not associated with conventional PDMS. Extraction followed by hydrothermal annealing removes unbound oligomers, promotes polymer cross-linking, facilitates covalent bond formation with glass, and retains the highest biocompatibility. Herein, our extraction protocol accelerates oligomer removal from 5 to 2 days. Resulting microfluidic platforms are uniquely suited for cell-network studies owing to high adhesion forces, effectively corralling cellular extensions and eliminating harmful oligomers. We demonstrate the simple, simultaneous actuation of multiple microfluidic domains for invoking ATP- and glutamate-induced Ca 2+ signaling in glial-cell networks. These E-PDMS modifications and flow manipulations further enable microfluidic technologies for cell-signaling and network studies as well as novel applications.

36 MATERIALS SCIENCE↗

Technical Feasibility Aspects of the Geothermal Resource Reporting Methodology (GRRM)

This paper reviews the technical assessment of the Geothermal Research Reporting Methodology (GRRM, http://en.openei.org/wiki/GRRM) being developed for reporting geothermal resources and project progress. The goal of the methodology is to provide the U.S. Department of Energy's Geothermal Technologies Office (GTO) with a consistent and comprehensible means of evaluating the impacts of its funding programs. The GRRM is designed to provide uniform assessment criteria for geothermal resource grades and developmental phases of geothermal resource exploration and development. This resource grade system provides information on twelve attributes of geothermal resource locations (e.g., temperature, permeability, land access) to indicate potential for geothermal development. The GTO plans to use these Protocols to help quantitatively identify the greatest barriers to geothermal development, develop measureable program goals that will have the greatest impact to geothermal deployment, objectively evaluate proposals based (in part) on a project's ability to contribute to program goals, monitor project progress, and report on GTO portfolio performance. The GRRM assesses three areas of geothermal potential: geological, socio-economic, and technical. Previous work and publications have discussed the work done on the geological aspects of this methodology (Young et al. 2015c); this paper details the development of the technical assessment of the GRRM. Technical development attributes considered include: reservoir management, drilling, logistics, and power conversion.

15 GEOTHERMAL ENERGY↗

2012 Geothermal Technologies Peer Review Summary: Mapping Diffuse Seismicity

The purpose of this project as it relates to GTP goals is to create a methodology that can be successfully implemented at an EGS site to aid in the successful creation of an EGS reservoir. The MFP technique would allow developers to obtain better seismic information for input when characterizing the hazard and risk associated with induced seismic events and when creating and monitoring the EGS reservoir. The purpose of this project as it relates to the geothermal industry / market is to create a method by which certain recommendations within the 2012 Protocol for Addressing Induced Seismicity Associated with Enhanced Geothermal Systems can be more easily implemented. The particular recommendation referred to is that seismic instrumentation should be able to detect events at least as small as M1.0 and preferably down to M0.0. This technique has been shown to decrease the magnitude completeness threshold of existing seismic networks, and as such should positively impact implementation of the above recommendation.

15 GEOTHERMAL ENERGY↗