Search NASA⌕ Search

SEARCH · Search NASA

Results for “qualification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Test Report of Special Form Qualification Testing for the ORNL U ZiPCAN, Rev. 1

This report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by International Standards Organization (ISO) 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4).

42 ENGINEERING↗

Cesium Ion Exchange Using Spherical Resorcinol-Formaldehyde Resin in Support of Waste Qualification Testing for LAWPS

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering solids and processing through ion exchange columns to remove cesium. The ion exchange media is currently targeted to be spherical resorcinol-formaldehyde resin (SRF). This media has been tested in a wide array of simulants and process scales, but testing to date on actual tank waste has been limited to two tank wastes. Washington River Protection Solutions (WRPS) requested a study to determine if a simple batch contact test with SRF can be used to qualify tank waste supernate prior to processing it in the LAWPS. The goal of the batch contact testing would be to determine if there are any issues with the tank waste that would preclude Cs removal by the ion exchanger.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data includes, but is not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DFLAW Glass and Feed Qualifications to Support WTP Start-Up and Flow-Sheet Development (Final Report, Rev. 0)

In each test, a distinct feed composition was used to determine the effects of feed composition changes on the retention of technetium and other species as detailed in the Test Plan for this work. Key operating parameters such as the glass temperature (nominally 1150°C) were held constant to investigate the effect of each new feed composition on the retention of technetium. The processing rate was maintained at ≈2,250 kg/m 2 /day of glass, which corresponds to the “stretch-goal” rate of 22.5 MT/day specified by ORP for the WTP LAW melter, or ≈2,000 kg/m 2 /day of glass, which corresponds to the enhanced baseline specified by ORP for the WTP LAW melter (as compared to the nominal 1500 kg/m 2 /day). The bubbling rate was adjusted to achieve a near-complete cold-cap (90-100% of melt surface covered with feed). Quantitative measurements of glass production rates, melter operating conditions (temperatures, pressures, power, flows, etc.), gaseous emissions by Fourier Transform Infrared Spectroscopy (FTIR), and particulate emissions using Environmental Protection Agency (EPA) methods were made for each test. Discharged and melt pool glass samples were inspected for formation of any salt phases and analyzed for chemical composition, including technetium content. Samples of the process fluids from each of the off-gas treatment system components were collected and analyzed. Following each test, the off-gas system was partially disassembled and extensively sampled for any residual feed components residing within the off-gas system. Sampling and analysis during and subsequent to each test was intended to be sufficient for supporting a mass balance for all constituents of interest and particularly technetium, rhenium, iodine, sulfur, chlorine, and fluorine. Additional sampling and analysis of evaporator concentrates and condensates was conducted for various organic compounds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effluent Management Facility Stack Monitor Qualification: Assessment with Surrogate Stacks

Sampling and monitoring at the Waste Treatment and Immobilization Plant (WTP) Effluent Management Facility (EMF) exhaust is required to meet the regulatory criteria that governs stacks that may exceed the 0.1-millirem per year threshold limit given in Title 40 of the Code of Federal Regulations, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standard for Emissions of Radionuclides other than Radon from Department of Energy Facilities. As a result, the flow conditions and probe location must be within certain bounds as prescribed by the American National Standards Institute/Health Physics Society (ANSI/HPS) standard N13.1-1999. Compliance with the standard may be demonstrated by tests on the stack itself, or with a surrogate stack (i.e., a scale model or other geometrically similar stack). Pacific Northwest National Laboratory (PNNL) has performed scale model stack tests for 11 of the 20 emission points that are planned for the WTP. Additionally, PNNL has full scale stack results from Idaho National Laboratory and PNNL facility stacks to use as references. One or more WTP scale model stack results were expected to be appropriate as a surrogate stack to the EMF. This report describes the EMF stack monitoring location as well as an assessment of existing surrogate stacks used to qualify the EMF stack sampling location.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effluent Management Facility Evaporator Bottoms: Waste Streams Formulation and Waste Form Qualification Testing

This report describes the results from grout formulation and cementitious waste form testing performed by Pacific Northwest National Laboratory for Washington River Protection Solutions, LLC (WRPS). These results are part of a screening test that investigates grout formulations proposed for encapsulating a wide range of compositions predicted to be present in evaporator bottoms wastes from the Hanford Effluent Management Facility (EMF). This work supports the technical development need for alternative treatment and disposition paths for the EMF evaporator bottoms waste and future direct-feed low-activity waste (DFLAW) operations at the Hanford Site. High-priority activities included simulant production, grout formulation, and cementitious waste form testing. The work contained within this report relates to waste form development and testing, but does not directly support the 2017 Integrated Disposal Facility (IDF) performance assessment (PA). However, this work contains information useful for future PA updates [beyond fiscal year (FY) 2017] and future waste form development efforts. These analytical results can be used by (i) cementitious waste form scientists to further the understanding of cementitious leach behavior of contaminants of concern (COCs), (ii) decision makers interested in off-site waste form disposal, and (iii) the U.S. Department of Energy, their Hanford Site contractors, and stakeholders as they continue to assess the IDF PA program at the Hanford Site. The reported results help fill existing data gaps, support final selection of a cementitious waste form for the EMF evaporator bottoms waste, and improve the technical defensibility of long-term waste form risk estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Standard High Solids Vessel Design Non-Newtonian Simulant Qualification

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is working to develop a Standard High Solids Vessel Design process vessel. To support testing of this new design, WTP engineering staff requested that a non-Newtonian simulant be developed that would represent the Most Adverse Design Condition (MADC), denoted as MADC-4, with respect to mixing performance as specified by WTP. The majority of the simulant requirements are specified in 24590-PTF-RPT-PE-16-001, Rev. 0, and a discussion of suggested non-Newtonian rheological parameters for the simulant was provided in WTP RPT-241, Rev. 0. This document describes the simulant composition that will satisfy the basis requirement along with ancillary testing to assess the rheological behavior of the simulant depending on the formulation approach used, simulant aging, and the effects of dilution. From this data, a simulant recipe to meet the basis is recommended. The simulant recipe was designed to meet a target rheology (as expressed by Bingham model parameters) of 34.5 ± 1.5 Pa [yield stress] and 33.5 ±1.5 cP [consistency] at 25 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IHE Material and IHE Subassembly Qualification Test Description and Criteria (v. 14.7)

The purpose of the deflagration-to-detonation test is to demonstrate that an IHE material will not undergo deflagration-to-detonation transition (DDT) under stockpile relevant conditions of scale, confinement, and material condition. Inherent in this test design is the assumption that ignition does occur, with onset of deflagration. The test design will incorporate large margins and replicates to account for the stochastic nature of DDT events.

36 MATERIALS SCIENCE↗

Technical Qualification of New Materials for High Efficiency Coal-Fired Boilers and Other Advanced FE Concepts: Haynes® 282® ASME Boiler and Pressure Vessel Code Case

This DOE Fossil Energy project, FEAA117, addressed materials issues relevant to qualifying and deploying a Ni-base alloy for a new application in an advanced ultra-supercritical coal-fired boiler. The goal was the deployment of Haynes International alloy Haynes® 282® for applications in superheaters, reheaters, and steam delivery pipes, by completing base metal, cross-weld and all-weld metal mechanical testing needed for an ASME Boiler and Pressure Vessel Code Case and the associated microstructural analyses needed for assurance of boiler-relevant lifetimes. The alloy also is of interest for other applications including supercritical CO₂ power generation cycles. Tensile testing was completed from 20°-927°C on the three base metal alloy 282 heats, two sets of cross-weld specimens and all weld metal specimens. A total of 148 creep tests with over 565,000 h of cumulative testing was completed on base metal, cross-weld and all weld metal specimens. This project was performed with cost share from Haynes International.

01 COAL, LIGNITE, AND PEAT↗

Data-Driven Understanding of Low-to-Moderate Income Customers’ Adoption and Financial Qualification in Community Solar

Through this project, we sought to gather a body of customer data that either proved or disproved our assumption that metrics other than FICO can and should be used to qualify customers for community solar. Using customer data on income, FICO scores, and utility/rent/cell phone repayment history, we developed an alternative metric in order to test in the market at a small scale whether new qualifying metrics could open the shared solar market up to millions of additional households. We demonstrate that the EnergyScore is both more accurate in qualifying customers that will not default, and more inclusive in qualifying low to moderate income households. We are now in the process of utilizing the EnergyScore in a number of pilot projects, building a robust dataset of customer churn and default, and subsequently disseminating this data to more traditional and larger scale financiers and solar developer partners to change the way potential customers are qualified.

14 SOLAR ENERGY↗

Test Report for the Qualification Testing of the ORNL-SFC-W-1 Special Form Capsule

Three prototypes the ORNL-SFC-W-1 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the three ORNL-SFC-W-1 capsules. The test units were designated as TU-1, TU-2 and TU-3. TU-1 was subjected to leak testing, impact testing and percussion testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). Both TU-2 and TU-3 were subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests as specified in American National Standards Institute (ANSI) N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

42 ENGINEERING↗

Data-Driven Understanding of Low-to-Moderate Income Customers’ Adoption and Financial Qualification in Community Solar (Final Technical Report)

When Solstice began working in the community solar industry, it quickly became clear that there was a wide disparity along race and class lines in terms of what kind of household traditional solar offerings benefited. Solstice is an organization that aligns itself to the principles of a Just Transition, or the concept that a transition to a green economy should benefit and prioritize historically marginalized groups of people. Given that low-income communities are disproportionately burdened by our current polluting fossil fuel economy, Solstice set out to investigate the root causes of the exclusion of low to moderate income (LMI) households in the community solar market. As we worked more and more with financiers, developers, and LMI households, we recognized that significant barriers to entry in a developer-owned project were credit threshold requirements. A FICO score of 750 and higher discriminates against LMI households that are not financially stable enough to take on multiple lines of credit (or who may not have been deemed credit worthy enough to access a line of credit) yet who may have been reliable utility customers. As Solstice began looking further into preliminary data and speaking to community-based organizations (CBOs) that serve LMI households, we found our hypothesis to be worth investigating; there was indeed a subset of LMI households with poor FICO scores (or no FICO score at all) that had perfect bill payment history. Though initially Solstice was intent on gathering a body of data to prove or disprove this hypothesis, we were also concerned that all this proof of a financially stable and reliable customer was not being incorporated into FICO, and wondered if such a score would be possible. After preliminary research into the existence of alternative scores, Solstice realized that many mission-driven lending institutions rely on alternative metrics that are formulated for their specific industry. However, we also realized that community solar did not have an alternative credit underwriting mechanism, though there was great need from solar financiers for one. We anticipated that the creation of an EnergyScore would contribute to financiers’ need to qualify more people, as these entities are desperately looking for ways to lower the cost of customer acquisition. FICO turns away nearly 50% of potential customers (according to our own acquisition experience), and much of the community solar industry is realizing that FICO is not the perfect qualifying mechanism. Additionally, with a grounding in energy justice, just transitions, and climate justice, Solstice recognizes the need for a solution that addresses a more urgent need for LMI households to access renewable energy savings and relieve energy burdens. With funding from the Department of Energy, we gathered the data necessary to build the EnergyScore, reached out to mission-driven developers willing to test the metric, and secured several demonstration projects to pilot the EnergyScore. After acquiring customers for these demo projects using the EnergyScore, we will be continuously collecting customer payment behavior data. Though it goes beyond the scope of this project, we plan to disseminate this de-identified data with the wider community solar industry, which includes not only financiers and developers, but other mission-driven nonprofits, solar cooperatives, community-based organizations, environmental justice activists, and academics. While we intend to disprove the notion that LMI households cannot be included in projects without acutely increasing the risk to project finances, we also hope the data can be used to negotiate better pricing of systems and terms of ownership for community groups seeking to build inclusive projects.

14 SOLAR ENERGY↗

Nimble Feedthrough Qualification - 125% High Explosive Overpressure Test Plan RevA

The primary purpose of this High Explosive (HE) Over-Pressure Test (OPT) is to qualify top cover diagnostic feedthroughs that will be used on LLNL Nimble Subcritical Experiment (SCE) Series designs per experimental design verification requirements specified in ASME Boiler and Pressure Vessel Code Case 2564, Impulsively-Loaded Pressure Vessels, Section VIII, Division 3; and to satisfy the over-test requirement of DOE-STD-1212. The diagnostic feedthroughs are part of the Vessel Confinement System (VCS), which is credited as a Safety Significant Design Feature per the U1a Facility Documented Safety Analysis (DSA). The OPT will be conducted at the LANL Area 1, R306 Firing Site (TA-15-R306) in a 3-foot diameter VCS depicted in Figure 1.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3420 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3420 Building filtered exhaust stack system. The updated system will increase the number of fans from three to four and will include ductwork to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing three-fan stack was previously found to comply with the ANSI/HPS N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified four-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing three-fan system showed good agreement with test data collected from the 3420 Building stack. Modeling was performed to develop a suitable four-fan design. Initial modeling of the four-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. The modeled final four-fan design, which meets the all the mixing criteria, included an air blender that is oversized relative to the main duct diameter to minimize the additional pressure drop created.

3420↗