Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Dependence of the saturable absorption of graphene upon excitation photon energy

Using an optical parametric oscillation laser as the excitation source, the dependence of the saturable absorption of multiple-layer graphene upon photon energy is investigated and, in all cases, the saturation intensity is lower for lower excitation photon energy. This result experimentally proves the hourglass shape of the energy band of graphene, which is a well-known theoretical deduction from first principles. The modulation depth increases from 1.5% to 5.1% when the layer number increases from a monolayer to 5–7 layers and, at the same time, the saturation intensity decreases with increasing number of layers. The results demonstrate that, as a saturable absorber of a pulsed laser, graphene can more easily achieve optical modulation in the low energy region, i.e., the infrared waveband.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser cooling of {sup 171}Yb{sup +} ions in a frequency-modulated field

We have investigated the laser cooling of ytterbium ions in a radio-frequency trap by a frequency-modulated resonant laser field. It has been shown that the lowest laser cooling temperatures, close to the Doppler limit, can be reached at field modulation parameters μ ⩾ 0.1. At lower μ values, the region of field parameters optimal for cooling shifts to higher intensities and the minimum possible laser cooling temperature increases. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma equilibrium in a semiclassical plasma due to non-resonant wave particle interactions

A nonresonant perturbative approach has been utilized to probe the modification of the equilibrium plasma distribution function due to plasma interaction with externally launched high-frequency large-amplitude RF waves in the presence of quantum effects. The quantum distribution function from the complete Wigner equation has been obtained for a high-frequency wave with constant amplitude. For waves with weak spatial or temporal modulation, the equilibrium distribution function has been obtained by solving the Wigner equation as an initial or boundary-value problem and retaining only lowest-order quantum effects. In the dipole approximation, a higher order diffusion has been identified in addition to quantum modified ponderomotive and quasilinear diffusion effects. Additional terms of the Wigner equation give the impression of higher order diffusion effects in the system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Algorithms for calculation of the transport tensor components in the generalized first collision probability method

The first collision probability (FCP) method allows generalization by introducing several angular modes in each zone. Algorithms are proposed for calculating the components of the corresponding first collision tensor. These algorithms do not increase the computational complexity beyond that of the matrix calculation algorithm in the traditional FCP method and allow calculating a system described in terms of combinatorial geometry. Fourfold integrals are numerically taken in calculation of a three-dimensional system and twofold integrals are taken for two-dimensional geometry. The geometrical capabilities are ensured by using the standard geometrical module of the Monte Carlo method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum key distribution over probabilistic quantum repeaters

A feasible route toward implementing long-distance quantum key distribution (QKD) systems relies on probabilistic schemes for entanglement distribution and swapping as proposed in the work of Duan, Lukin, Cirac, and Zoller (DLCZ) [Nature (London) 414, 413 (2001)]. Here, we calculate the conditional throughput and fidelity of entanglement for DLCZ quantum repeaters by accounting for the DLCZ self-purification property in the presence of multiple excitations in the ensemble memories as well as loss and other sources of inefficiency in the channel and measurement modules. We then use our results to find the generation rate of secure key bits for QKD systems that rely on DLCZ quantum repeaters. We compare the key generation rate per logical memory employed in the two cases with and without a repeater node. We find the crossover distance beyond which the repeater system outperforms the nonrepeater one. That provides us with the optimum internode distancing in quantum repeater systems. We also find the optimal excitation probability at which the QKD rate peaks. Such an optimum probability, in most regimes of interest, is insensitive to the total distance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tough Errors are no Match (TEAM): Optimizing the Quantum Compiler for Noise Resilience

This project builds toward a comprehensive error-mitigating toolkit that makes quantum programming more robust and adaptive to the noisy, resource-limited nature of today’s quantum hardware. To that end, it integrates established error-mitigation methods — such as zero-noise extrapolation and dynamical decoupling — directly into compiler infrastructures. These techniques will be packaged as modules that can automatically adjust and combine based on performance analysis, enabling compilers to explore large design spaces and produce optimized, low-noise quantum programs with minimal manual intervention. In parallel, this project also explores new approaches to analog quantum programming or quantum simulation, and has developed the programming language SimuQ which treats quantum Hamiltonian evolution as the central object.

97 MATHEMATICS AND COMPUTING↗

Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system

Purpose: Undertaking observer studies to compare imaging technology using clinical radiological images is challenging due to patient variability. To achieve a significant result, a large number of patients would be required to compare cancer detection rates for different image detectors and systems. The aim of this work was to create a methodology where only one set of images is collected on one particular imaging system. These images are then converted to appear as if they had been acquired on a different detector and x-ray system. Therefore, the effect of a wide range of digital detectors on cancer detection or diagnosis can be examined without the need for multiple patient exposures. Methods: Three detectors and x-ray systems [Hologic Selenia (ASE), GE Essential (CSI), Carestream CR (CR)] were characterized in terms of signal transfer properties, noise power spectra (NPS), modulation transfer function, and grid properties. The contributions of the three noise sources (electronic, quantum, and structure noise) to the NPS were calculated by fitting a quadratic polynomial at each spatial frequency of the NPS against air kerma. A methodology was developed to degrade the images to have the characteristics of a different (target) imaging system. The simulated images were created by first linearizing the original images such that the pixel values were equivalent to the air kerma incident at the detector. The linearized image was then blurred to match the sharpness characteristics of the target detector. Noise was then added to the blurred image to correct for differences between the detectors and any required change in dose. The electronic, quantum, and structure noise were added appropriate to the air kerma selected for the simulated image and thus ensuring that the noise in the simulated image had the same magnitude and correlation as the target image. A correction was also made for differences in primary grid transmission, scatter, and veiling glare. The method was validated by acquiring images of a CDMAM contrast detail test object (Artinis, The Netherlands) at five different doses for the three systems. The ASE CDMAM images were then converted to appear with the imaging characteristics of target CR and CSI detectors. Results: The measured threshold gold thicknesses of the simulated and target CDMAM images were closely matched at normal dose level and the average differences across the range of detail diameters were -4% and 0% for the CR and CSI systems, respectively. The conversion was successful for images acquired over a wide dose range. The average difference between simulated and target images for a given dose was a maximum of 11%. Conclusions: The validation shows that the image quality of a digital mammography image obtained with a particular system can be degraded, in terms of noise magnitude and color, sharpness, and contrast to account for differences in the detector and antiscatter grid. Potentially, this is a powerful tool for observer studies, as a range of image qualities can be examined by modifying an image set obtained at a single (better) image quality thus removing the patient variability when comparing systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acousto-optical modulation of light at a doubled sound frequency

A method of acousto-optical (AO) Bragg diffraction is proposed that provides the amplitude modulation of optical radiation at a doubled acoustic frequency. The method is based on the double transmission of the light through the AO modulator made of a gyrotropic crystal and is experimentally tested by the example of the modulation of light with a wavelength of 0.63 μm, controlled by the paratellurite AO cell. (acoustooptics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear saturation and oscillations of collisionless zonal flows

Abstract In homogeneous drift-wave turbulence, zonal flows (ZFs) can be generated via a modulational instability (MI) that either saturates monotonically or leads to oscillations of the ZF energy at the nonlinear stage. This dynamics is often attributed as the predator–prey oscillations induced by ZF collisional damping; however, similar dynamics is also observed in collisionless ZFs, in which case a different mechanism must be involved. Here, we propose a semi-analytic theory that explains the transition between the oscillations and saturation of collisionless ZFs within the quasilinear Hasegawa–Mima model. By analyzing phase-space trajectories of DW quanta (driftons) within the geometrical-optics (GO) approximation, we argue that the parameter that controls this transition is N ∼ γ MI / ω DW , where γ MI is the MI growth rate and ω DW is the linear DW frequency. We argue that at N ≪ 1, ZFs oscillate due to the presence of so-called passing drifton trajectories, and we derive an approximate formula for the ZF amplitude as a function of time in this regime. We also show that at N ≳ 1, the passing trajectories vanish and ZFs saturate monotonically, which can be attributed to phase mixing of higher-order sidebands. A modification of N that accounts for effects beyond the GO limit is also proposed. These analytic results are tested against both quasilinear and fully-nonlinear simulations. They also explain the earlier numerical results by Connaughton et al (2010 J. Fluid Mech. 654 207) and Gallagher et al (2012 Phys. Plasmas 19 122115) and offer a different perspective on what the control parameter actually is that determines the transition from the oscillations to saturation of collisionless ZFs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Markov chain Monte Carlo with digital dissipative dynamics on quantum computers

Modeling the dynamics of a quantum system connected to the environment is critical for advancing our understanding of complex quantum processes, as most quantum processes in nature are affected by an environment. Modeling a macroscopic environment on a quantum simulator may be achieved by coupling independent ancilla qubits that facilitate energy exchange in an appropriate manner with the system and mimic an environment. This approach requires a large, and possibly exponential number of ancillary degrees of freedom which is impractical. In contrast, we develop a digital quantum algorithm that simulates interaction with an environment using a small number of ancilla qubits. By combining periodic modulation of the ancilla energies, or spectral combing, with periodic reset operations, we are able to mimic interaction with a large environment and generate thermal states of interacting many-body systems. We evaluate the algorithm by simulating preparation of thermal states of the transverse Ising model. Our algorithm can also be viewed as a quantum Markov chain Monte Carlo process that allows sampling of the Gibbs distribution of a multivariate model. To illustrate this we evaluate the accuracy of sampling Gibbs distributions of simple probabilistic graphical models using the algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-206-06: Task-Specific Optimization of Scintillator Thickness for CMOS-Detector Based Cone-Beam Breast CT

Purpose: To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. Methods: The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular pentagon with 2 mm spacing on its sides and a central calcification, similar to that in ACR-recommended mammography accreditation phantom, at a mean glandular dose of 4.5 mGy. Generalized parallel-cascades based linear systems analysis was used to determine Fourier-domain image quality metrics in reconstructed object space, from which the detectability index inclusive of anatomical noise was determined for a non-prewhitening numerical observer. For 300 projections over 2π, magnification-associated focal-spot blur, Monte Carlo derived x-ray scatter, K-fluorescent emission and reabsorption within CsI:Tl, CsI:Tl quantum efficiency and optical blur, fiberoptic plate transmission efficiency and blur, CMOS quantum efficiency, pixel aperture function and additive noise, and filtered back-projection to isotropic 105µm voxel pitch with bilinear interpolation were modeled. Imaging geometry of a clinical prototype breast CT system, a 60 kV Cu/Al filtered x-ray spectrum from 0.3 mm focal spot incident on a 14 cm diameter semi-ellipsoidal breast were used to determine the detectability index for 300–600 µm thick (75µm increments) CsI:Tl. The CsI:Tl thickness that maximized the detectability index was considered optimal. Results: The limiting resolution (10% modulation transfer function, MTF) progressively decreased with increasing CsI:Tl thickness. The zero-frequency detective quantum efficiency, DQE(0), in projection space increased with increasing CsI:Tl thickness. The maximum detectability index was achieved with 525µm thick CsI:Tl scintillator. Reduced MTF at mid-to-high frequencies for 600µm thick CsI:Tl lowered the detectability index than 525µm CsI:Tl. Conclusion: For the x-ray spectrum and imaging conditions considered, a 525µm thick CsI:Tl scintillator integrated with the CMOS detector is optimal for detecting microcalcification cluster. Funding support: Supported in part by NIH R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI. Disclosures: SV, GV and AK - Research collaboration, Koning Corp., West Henrietta, NY.

60 APPLIED LIFE SCIENCES↗

On the possibility of increasing the pulse energy of a passively Q-switched erbium glass minilaser

A simple method to increase the output energy of a passively Q-switched erbium glass laser is proposed. Using the amplitude modulation of losses at the active element face, the fundamental mode was reliably suppressed and the laser operated in a selected higher-order mode. The output energy was experimentally increased by a factor of 2.1, and the range of allowable pump energy instability was extended threefold. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Programmable entanglement oscillations in a non-Markovian channel

We suggest and demonstrate an all-optical experimental setup to observe and engineer entanglement oscillations of a pair of polarization qubits in an effective non-Markovian channel. We generate entangled photon pairs by spontaneous parametric down-conversion (SPDC), and then insert a programmable spatial light modulator in order to impose a polarization-dependent phase shift on the spatial domain of the SPDC output. This creates an effective programmable non-Markovian environment where modulation of the environment spectrum is obtained by inserting a spatial grating on the signal arm. In our experiment, programmable oscillations of entanglement are achieved, where the entangled state obtained at the maximum of the revival after sudden death violates Bell's inequality by 17 standard deviations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Information coding of exciting laser pulses in an optical echo-processor

We report the possibility of controlling the distribution of quantum bits within an inhomogeneously broadened line of a resonant transition in recording and transforming information in optical echo-processors. We consider the efficiency of realisation of the elementary logic XOR gate based on a two-pulse excitation of a resonant medium with phase memory. The encoded information is incorporated into the temporal shape of laser pulses in the form of amplitude modulation of an 'echelon' of present ('1') and absent ('0') pulse-codes for obtaining more efficient logic elements that reduce the noise in a quantum communication channel. (optical information processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Excitons in artificial quantum dots in the weak spatial confinement regime

The exciton states in individual quantum dots prepared by the selective interdiffusion method in CdTe/CdMgTe quantum wells are studied by the methods of steady-state optical spectroscopy. The annealing-induced diffusion of Mg atoms inward to the bulk of the quantum well, which is significantly enhanced under the SiO{sub 2} mask, leads to a modulation of the bandgap width in the plane of the well, with the minima of the potential being located in the mask aperture areas. A lateral potential that arises, whose height is in the range 30-270 meV and characteristic scale is about 100 nm, efficiently localizes carriers, which form quasi-zero-dimensional excitons in the weak spatial confinement regime. Detailed magnetooptical studies show that Coulomb correlations play a significant role in the formation of exciton states under such a regime, which, in particular, manifests itself in the localization of the wavefunction of carriers on scales that are considerably smaller than the scale of the lateral potential. The particular features of the interlevel splitting, of the biexciton binding energy, and of the diamagnetic shift are discussed. A strong dependence of the interlevel relaxation on the interlevel splitting (the phonon neck) indicates that alternative relaxation mechanisms in the quantum dots studied are weak. The excited states are populated according to the Pauli principle, which indicates that it is possible to apply the shell model of many-exciton states to quantum dots under the weak spatial confinement conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct measurement of sub-wavelength interference using thermal light and photon-number-resolved detection

We examine thermal light diffracted through a double slit using photon-number-resolved detection to directly measure high-order spatial correlations, and we see sinusoidal modulations of those correlations. The fringe width can, in principal, be made arbitrarily small, and we have experimentally obtained fringe widths as small as 30 nm with 800 nm wavelength light. This extreme sub-wavelength resolution, along with this direct detection technique, offers potential for high precision measurement applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manipulation of orbital occupancy by ferroelectric polarization in LaNiO{sub 3}/BaTiO{sub 3−δ} heterostructures

We investigate the control of orbital occupancy by ferroelectric polarization in LaNiO{sub 3}/BaTiO{sub 3−δ} heterostructures. It is achieved by the ferroelectric displacement of Ti ions polarized downward (upward) to form (break) Ni–O–Ti covalent bonding at the interface, accompanied by charge transfer between them and the modulation of the conductivity of ultrathin LaNiO{sub 3}. This electrically switchable and bi-direction control of orbital polarization in LaNiO{sub 3} is up to 25%, different from the manipulation by epitaxial strain or quantum confinement. Our finding opens a window for electrical control of orbital polarization at an oxide interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗