Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Formation mechanism of the secondary building unit in a chromium terephthalate metal-organic framework

Based on density functional theory calculations and simulation, a detailed mechanism is presented on the formation of the secondary building unit (SBU) of MIL-101, a chromium terephthalate metal-organic framework (MOF). SBU formation is key to MOF nucleation, the rate-limiting step in the formation process of many MOFs. A series of reactions that lead to the formation of the SBU of MIL-101 is proposed in this work. Initial rate-limiting reactions form the metal cluster with three chromium (III) atoms linked to a central bridging oxygen. Terephthalate linkers play a key role as chromium (III) atoms are joined to linker carboxylate groups prior to the placement of the central bridging oxygen. Multiple linker addition reactions, which follow in different paths due to structural isomers, are limited by the removal of water molecules in the first chromium coordination shell. The least energy path is identified were all linkers on one face of the metal center plane are added first. A simple kinetic model based on transition state theory shows the rate of secondary building unit formation similar to the rate metal-organic framework nucleation. The authors are thankful to Dr. R. Rousseau for a critical reading of the manuscript. This research would not have been possible without the support of the Office of Fossil Energy, U.S. Department of Energy. This research was performed using EMSL, a national scientific user facility sponsored by the Department of Energy's Office of Biological and Environmental Research and the PNNL Institutional Computing (PIC) program located at Pacific Northwest National Laboratory.

36 MATERIALS SCIENCE↗

Thermoradiative energy conversion in infrared interband cascade InAs/GaSb/AlInSb/GaSb type-II superlattice diodes

Thermoradiative energy conversion presents a means for the direct conversion of thermal energy through radiative transfer to a cold scene. However, much of the study of thermoradiative principles has been based on theory and simulations, with only sparse reports on the experimental demonstration of the concept. This work studies thermoradiative energy conversion in InAs/GaSb/AlInSb/GaSb type-II superlattice cascade devices. The devices exhibit a cutoff wavelength of 3.2 μm at 300 K, corresponding to a bandgap of 0.39 eV. Testing under a temperature-controlled chamber and scene demonstrates a maximum power density of 2.9 mW/m2 at a cell temperature of 121 °C. It is consistent with expected values for device operation limited by Shockley–Read–Hall non-radiative recombination. This result is a significant step in providing an experimental demonstration of thermoradiative energy conversion and a means to characterize cell performance, providing a foundation for further development to achieve practical values for power generation.

Islam, Md Toriqul (ORCID:0000000249871320)↗

Physical evaluation of a needle photostimulable phosphor based CR mammography system

Purpose: Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. Methods: Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose, for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. Results: MTF at 5 mm{sup -1} was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement ({approx}20%) over the two powder CR systems but remained 50% lower than the result at 5 mm{sup -1} for the a-Se detector ({approx}0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at {approx}100 {mu}Gy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm{sup -1}) was 0.19 for the needle CR plates, a factor of approximately 3 greater than for the powder CR plates. At 28 kV W/Rh, 2 mm Al, peak DQE for the needle CR system was 0.45 against a value of 0.50 for the a-Se detector. The needle CR detector reached the Acceptable limit for 0.1 mm details in the European Guidelines at a mean glandular dose (MGD) of approximately 1.31 mGy imaged at 28 kV Mo/Rh, compared to figures of 2.19 and 1.43 mGy for the single sided and dual sided readout powder CR systems. The a-Se detector could reach the limit at 0.65 mGy using a 28 kV W/Rh spectrum, while the needle CR system required 1.09 mGy for the same spectrum. Conclusions: Imaging performance for the needle CR phosphor technology, characterized using MTF and DQE and threshold gold thickness demonstrated a clear improvement compared to both single and dual sided reading powder phosphor based CR systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing a standard calibration methodology for MOSFET detectors in computed tomography dosimetry

Purpose: The use of metal-oxide-semiconductor field-effect transistor (MOSFET) detectors for patient dosimetry has increased by {approx}25% since 2005. Despite this increase, no standard calibration methodology has been identified nor calibration uncertainty quantified for the use of MOSFET dosimetry in CT. This work compares three MOSFET calibration methodologies proposed in the literature, and additionally investigates questions relating to optimal time for signal equilibration and exposure levels for maximum calibration precision. Methods: The calibration methodologies tested were (1) free in-air (FIA) with radiographic x-ray tube, (2) FIA with stationary CT x-ray tube, and (3) within scatter phantom with rotational CT x-ray tube. Each calibration was performed at absorbed dose levels of 10, 23, and 35 mGy. Times of 0 min or 5 min were investigated for signal equilibration before or after signal read out. Results: Calibration precision was measured to be better than 5%-7%, 3%-5%, and 2%-4% for the 10, 23, and 35 mGy respective dose levels, and independent of calibration methodology. No correlation was demonstrated for precision and signal equilibration time when allowing 5 min before or after signal read out. Differences in average calibration coefficients were demonstrated between the FIA with CT calibration methodology 26.7 {+-} 1.1 mV cGy{sup -1} versus the CT scatter phantom 29.2 {+-} 1.0 mV cGy{sup -1} and FIA with x-ray 29.9 {+-} 1.1 mV cGy{sup -1} methodologies. A decrease in MOSFET sensitivity was seen at an average change in read out voltage of {approx}3000 mV. Conclusions: The best measured calibration precision was obtained by exposing the MOSFET detectors to 23 mGy. No signal equilibration time is necessary to improve calibration precision. A significant difference between calibration outcomes was demonstrated for FIA with CT compared to the other two methodologies. If the FIA with a CT calibration methodology was used to create calibration coefficients for the eventual use for phantom dosimetry, a measurement error {approx}12% will be reflected in the dosimetry results. The calibration process must emulate the eventual CT dosimetry process by matching or excluding scatter when calibrating the MOSFETs. Finally, the authors recommend that the MOSFETs are energy calibrated approximately every 2500-3000 mV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction factors for ionization chamber dosimetry in CyberKnife: Machine-specific, plan-class, and clinical fields

Purpose: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjaell, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, 'A new formalism for reference dosimetry of small and nonstandard fields,' Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. Methods: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. Results: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. Conclusions: The differences found between overall correction factors associated with the proposed intermediate calibration fields and the clinical fields under investigation show that depending on the clinical field and the detector used, either a machine-specific reference field or a plan-class specific reference field is more representative for the clinical field. Given the experimental and numerical uncertainties and the small number of clinical fields considered in this study the significance of these observations is limited and it remains unclear for the CyberKnife if there would be a significant gain in using a pcsr field rather than a msr field as reference field for relative dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Contingency Contractor Optimization Tool Prototype (Phase 3 Extension- Analyst Tutorial)

This tutorial walks the user through analysis examples using the Contingency Contractor Optimization Tool Prototype. The examples are designed to showcase key capabilities of the tool. The main goal of this tutorial is to provide examples of how to use the tool to perform analyses to those users acting in the analyst role. All examples and locations used in the prototype are fictional, but are intended to be realistic. Users reading this manual are expected to have a basic understanding and familiarity with the Contingency Contractor Optimization Tool Prototype. This tutorial includes scenarios for the occurrence of two wars, Prussia and New Granada.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Prototype Distributed Ledger Technology of UF 6 Cylinder Tracking in Ethereum

We have created a demonstration permissioned Distributed Ledger Technology (DLT) datastore for the UF 6 cylinder tracking safeguards use-case utilizing the Ethereum DLT framework and using Solidity for smart contract code. Our demonstration creates a simulated dataset representing tracking of 75,000 UF 6 cylinders across 11 example nuclear facilities worldwide. Our DLT system allows for easy input and reading of shipping and receiving data, including a Graphical User Interface (GUI). Sandia’s Emulytics capability was leveraged to help create the DLT node network and assess performance. We find that our DLT prototype can easily handle to ~150,000 UF 6 cylinder shipments per year worldwide, without any excessive computational or storage burden on the IAEA or Member States. Next steps could include a demonstration to the IAEA and potentially demonstrating integration with TradeLens, a DLT in use by a consortium of international shipping companies representing over half of world shipping trade.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Decimal digit generator for commutated data: A Concept

Perform analog-to-digital conversion on input signal with staircase circuit having 10% resolution, convert digital result to analog voltage, subtract it from original input signal; read out feedback signals as decimal digit representation during one clock phase and servo-error difference between input and feedback as analog portion during following clock phase.

Rusk, S. J.↗

Development of the JSC Thematic Mapper quick-look preprocessing capability

The development of a preprocessing unit for Landsat Thematic Mapper (TM) data for the Earth Observations Data Laboratory at Johnson Space Center is reported. The background of the project is sketched, including the greatly increased data-handling requirements compared to MSS, the influence of the JPL VICAR system on the system design, and the completeness of the GSFC SCROUNGE (LASLIB) TM data tapes. The design approach and realization are discussed, and the performance and transportability of the preprocessor programs (totaling about 2000 lines of source code in FORTRAN and IBM Assembly languages) are indicated. The system is able to read the TM image tapes, extract areas of interest to particular studies, and register the extracted imagery to suitable references. Ancillary programs include image enhancement, rotation, filtering and pixel-size modification.

Gilbert, J. R.↗

Guaranteeing Failsafe Operation of Extended-Scene Shack-Hartmann Wavefront Sensor Algorithm

A Shack-Hartmann sensor (SHS) is an optical instrument consisting of a lenslet array and a camera. It is widely used for wavefront sensing in optical testing and astronomical adaptive optics. The camera is placed at the focal point of the lenslet array and points at a star or any other point source. The image captured is an array of spot images. When the wavefront error at the lenslet array changes, the position of each spot measurably shifts from its original position. Determining the shifts of the spot images from their reference points shows the extent of the wavefront error. An adaptive cross-correlation (ACC) algorithm has been developed to use scenes as well as point sources for wavefront error detection. Qualifying an extended scene image is often not an easy task due to changing conditions in scene content, illumination level, background, Poisson noise, read-out noise, dark current, sampling format, and field of view. The proposed new technique based on ACC algorithm analyzes the effects of these conditions on the performance of the ACC algorithm and determines the viability of an extended scene image. If it is viable, then it can be used for error correction; if it is not, the image fails and will not be further processed. By potentially testing for a wide variety of conditions, the algorithm s accuracy can be virtually guaranteed. In a typical application, the ACC algorithm finds image shifts of more than 500 Shack-Hartmann camera sub-images relative to a reference sub -image or cell when performing one wavefront sensing iteration. In the proposed new technique, a pair of test and reference cells is selected from the same frame, preferably from two well-separated locations. The test cell is shifted by an integer number of pixels, say, for example, from m= -5 to 5 along the x-direction by choosing a different area on the same sub-image, and the shifts are estimated using the ACC algorithm. The same is done in the y-direction. If the resulting shift estimate errors are less than a pre-determined threshold (e.g., 0.03 pixel), the image is accepted. Otherwise, it is rejected.

Sidick, Erikin↗

Forming Aggregations using Virtual Sharding: Lessons Learned from Simple Scalable Storage (S3)

Data aggregation is the ability to combine separate datasets to form a single new logical dataset provides users with a powerful abstraction. The advantage of an aggregate dataset is that the users are freed from having to understand, and incorporate into their workflow, knowledge about the (ad hoc) organization of the constituent datasets. However, aggregating large numbers of files can be computationally complex with data server systems performing many repetitive operations. As part of the authors work on subsetting data stored on Amazon Web Service (AWS) Simple Storage Service (S3), we developed technology to read portions of otherwise monolithic data files. This enables the formation of virtual shards for user in subsetting data stored in HDF5 (hierarchical data format, version 5) files. This same tool can be used to form aggregations that combine data stored in many HDF5 files when those files are stored on S3. The nature of the virtual sharding and the algorithm that exploits it for subsetting is such that it can also be used for aggregation with the need for many of the repetitive operations required by the per file aggregation techniques. We will present timing information that demonstrates the flexibility of this approach. However, the lessons learned is that while this is a useful result in and of itself, these very same techniques can be applied in other contexts where data are stored in services and on media other than S3. For example, this same technique can be applied to data stored on spinning disk. Pushing the envelope for S3 forced a reexamination of our data access techniques which lead to unexpected positive benefits.

Gallagher, James↗

Integrating The Non-Electrical Worker Into The Electrical Safety Program

The intent of this paper is to demonstrate an electrical safety program that incorporates all workers into the program, not just the electrical workers. It is largely in response to a paper presented at the 2012 ESW by Lanny Floyd entitled "Facilitating Application of Electrical Safety Best Practices to "Other" Workers" which requested all attendees to review their electrical safety program to assure that non-electrical workers were protected as well as electrical workers. The referenced paper indicated that roughly 50% of electrical incidents involve workers whose primary function is not electrical in nature. It also encouraged all to "address electrical safety for all workers and not just workers whose job responsibilities involve working on or near energized electrical circuits." In this paper, a program which includes specific briefings to non-electrical workers as well as to workers who may need to perform their normal activities in proximity to energized electrical conductors is presented. The program uses a targeted approach to specific areas such as welding, excavating, rigging, chart reading, switching, cord and plug equipment and several other general areas to point out hazards that may exist and how to avoid them. NFPA 70E-2004 was incorporated into the program several years ago and with it the need to include the "other" workers became apparent. The site experience over the years supports the assertion that about half of the electrical incidents involve non-electrical workers and this prompted us to develop specific briefings to enhance the knowledge of the non-electrical worker regarding safe electrical practices. The promotion of "May is Electrical Safety Month" and the development of informative presentations which are delivered to the general site population as well as electrical workers have greatly improved the hazards awareness status of the general worker on site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Carrier recombination dynamics and temperature dependent optical properties of InAs–GaSb heterostructures

Heterostructures with two dissimilar materials could offer unprecedented properties if one can carefully synthesize these heterostructures with atomically smooth interfaces and reduced number of recombination centers. InAs/GaSb-based heterostructures have technological importance for long wavelength infrared photodetectors if one can synthesize these materials with high-optical quality and high-carrier lifetime. In this work, the InAs/GaSb heterostructures with a different number of heterointerfaces and growth conditions were grown by solid source molecular beam epitaxy using valved cracker sources for both arsenic and antimony. Precise control of growth parameters and shutter sequences enabled abrupt InAs/GaSb heterointerfaces, as supported by a high-resolution transmission electron microscopic study. The temperature and power-dependent optical properties by photoluminescence (PL) spectroscopic analysis of InAs/GaSb heterostructures with 4 and 28 heterointerfaces displayed donor to the acceptor and the exciton bound to complex defects (V Ga Ga Sb ) 0 . Since the optical transition in PL measurements serves to determine the quality of the material, and the observed excitonic transitions from these InAs/GaSb heterostructures is an indication of high-quality materials. The high-carrier lifetimes of 139 ns to 185 ns from InAs/GaSb heterostructures were measured using microwave photoconductivity decay (μ-PCD) technique at room temperature. The observed increase in carrier lifetime is due to the decreasing number of Ga-related carrier recombination centers or defect complexes. This is further supported by the PL spectroscopic study. In addition, the carrier lifetime with different injection levels is supported by Shockley–Read–Hall recombination. We report these InAs/GaSb heterostructures with high-optical quality and high-carrier lifetimes would offer a path for the development of high-performance infrared photodetectors.

36 MATERIALS SCIENCE↗

Formation of SiGe nanocrystals embedded in Al{sub 2}O{sub 3} for the application of write-once-read-many-times memory

The structure of SiGe nanocrystals embedded in Al{sub 2}O{sub 3} formed by sequential deposition of Al{sub 2}O{sub 3}/Si/Ge/Al{sub 2}O{sub 3} and a subsequent annealing was confirmed by transmission electron microscopy and energy dispersive spectroscopy (EDS), and its application for write-once-read-many-times (WORM) memory devices was explored in this study. By applying a -10 V pulse for 1 s, a large amount of holes injected from Si substrate are stored in the nanocrystals and consequently, the current at +1.5 V increases by a factor of 10{sup 4} as compared to that of the initial state. Even with a smaller -5 V pulse for 1 {mu}s, a sufficiently large current ratio of 36 can still be obtained, verifying the low power operation. Since holes are stored in nanocrystals which are isolated from Si substrate by Al{sub 2}O{sub 3} with good integrity and correspond to a large valence band offset with respect to Al{sub 2}O{sub 3}, desirable read endurance up to 10{sup 5} cycles and excellent retention over 100 yr are achieved. Combining these promising characteristics, WORM memory devices are appropriate for high-performance archival storage applications.

36 MATERIALS SCIENCE↗

OSiRIS: a distributed Ceph deployment using software defined networking for multi-institutional research

We report on the first year of the OSiRIS project (NSF Award #1541335, UM, IU, MSU and WSU) which is targeting the creation of a distributed Ceph storage infrastructure coupled together with software-defined networking to provide high-performance access for wellconnected locations on any participating campus. The projects goal is to provide a single scalable, distributed storage infrastructure that allows researchers at each campus to read, write, manage and share data directly from their own computing locations. The NSF CC*DNI DIBBS program which funded OSiRIS is seeking solutions to the challenges of multi-institutional collaborations involving large amounts of data and we are exploring the creative use of Ceph and networking to address those challenges. While OSiRIS will eventually be serving a broad range of science domains, its first adopter will be the LHC ATLAS detector project via the ATLAS Great Lakes Tier-2 (AGLT2) jointly located at the University of Michigan and Michigan State University. Part of our presentation will cover how ATLAS is using the OSiRIS infrastructure and our experiences integrating our first user community. The presentation will also review the motivations for and goals of the project, the technical details of the OSiRIS infrastructure, the challenges in providing such an infrastructure, and the technical choices made to address those challenges. We will conclude with our plans for the remaining 4 years of the project and our vision for what we hope to deliver by the projects end.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-72: Geant4 Simulations of Spot-Scanned Proton Beam Treatment Plans

Purpose: To evaluate density inhomogeneities which can effect dose distributions for real-time image gated spot-scanning proton therapy (RGPT), a dose calculation system, using treatment planning system VQA (Hitachi Ltd., Tokyo) spot position data, was developed based on Geant4. Methods: A Geant4 application was developed to simulate spot-scanned proton beams at Hokkaido University Hospital. A CT scan (0.98 × 0.98 × 1.25 mm) was performed for prostate cancer treatment with three or four inserted gold markers (diameter 1.5 mm, volume 1.77 mm3) in or near the target tumor. The CT data was read into VQA. A spot scanning plan was generated and exported to text files, specifying the beam energy and position of each spot. The text files were converted and read into our Geant4-based software. The spot position was converted into steering magnet field strength (in Tesla) for our beam nozzle. Individual protons were tracked from the vacuum chamber, through the helium chamber, steering magnets, dose monitors, etc., in a straight, horizontal line. The patient CT data was converted into materials with variable density and placed in a parametrized volume at the isocenter. Gold fiducial markers were represented in the CT data by two adjacent voxels (volume 2.38 mm3). 600,000 proton histories were tracked for each target spot. As one beam contained about 1,000 spots, approximately 600 million histories were recorded for each beam on a blade server. Two plans were considered: two beam horizontal opposed (90 and 270 degree) and three beam (0, 90 and 270 degree). Results: We are able to convert spot scanning plans from VQA and simulate them with our Geant4-based code. Our system can be used to evaluate the effect of dose reduction caused by gold markers used for RGPT. Conclusion: Our Geant4 application is able to calculate dose distributions for spot scanned proton therapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-98: Dependence of Radiotherapy Couch Transmission Factors On Field Size and Couch-Isocenter Distance

Purpose: The dosimetric effect of the treatment couch is non-negligible in today's radiotherapy treatment. To accurately include couch in dose calculation, we investigated the dependence of couch transmission factors on field size and couch-isocenter distance. Methods: Couch transmission factors for Varian Exact Couch were determined by taking the ratios of ionization of a posterior-anterior beam with and without the couch in the beam path. Measurements were performed at the isocenter using a PTW cylindrical ionization chamber (Model 31030) with an Aluminum buildup cap of 1.1 cm thick for the 6 MV photon beam. Ionization readings for beam sizes ranging from 2 × 2 cm2 to 40 × 40 cm2 were taken. Transmission factors for couch-isocenter distances ranging from 3 cm to 20 cm were also investigated. Results: The couch transmission factors increased with the field size approximately in an exponential manner. For the field sizes that we tested, the transmission factor ranged from 0.976 to 0.992 for couch-isocenter distance of 3 cm. The transmission factor was also monotonically dependent on couch-isocenter separation distance, but in a lighter magnitude. For the tested couch heights, the transmission factor ranged from 0.974 – 0.972 for 2 × 2 cm2 field size and 0.992 – 0.986 for 40 × 40 cm2 field size. The dependence on couch-isocenter distance is stronger for larger field size. Conclusions: The transmission factor of a radiotherapy treatment couch increases with field size of the radiation beam and its distance from the isocenter. Such characterization of the couch transmission factor helps improve the accuracy of couch modeling for radiotherapy treatment planning.

60 APPLIED LIFE SCIENCES↗