Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

WHONDRS Summer 2019 Sampling Campaign: Global River Corridor Surface Water FTICR-MS, NPOC, TN, Anions, Stable Isotopes, Bacterial Abundance, and Dissolved Inorganic Carbon (v8)

The WHONDRS Summer 2019 Sampling (S19S) Campaign collected samples in 97 globally distributed river corridor systems between July and September 2019. Surficial streambed sediments were collected at three locations within each site (upstream, midstream, and downstream). Surface water was collected at the downstream site. This dataset includes a portion of the data types produced from the surface water samples and does not include any results from the sediment. Sediment data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1729719. The S19S campaign was designed with the science community to ask questions associated with links among core/transient metabolomes, microbial metabolism, biogeochemical function, and physical properties of watershed and river corridor systems. This data package was originally published in March 2020. It was updated in October 2020 (v2, new and modified files), July 2021 (v3, new and modified files), January 2023 (v4, new and modified files), February 2023 (v5, new and modified files), August 2023 (v6, new and modified files), July 2025 (v7,new and modified files), and August 2026 (v8, new and modified files). Version 8 includes major restructuring of the files and their formats. See the change history section in readme for more details. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset contains (1) readme, (2) data dictionary, (3) file level metadata, (4) sampling protocol, (5) a data checks report, (6) field metadata, (7) international generic sample number (IGSN) mapping file, (8) joint genome institute (JGI) mapping file, and (9) a folder of sample data. The sample data folder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and FTICR methods, (2) dissolved inorganic carbon (DIC), (3) stable water isotopes (O and H), (4) specific conductivity, (5) total dissolved nitrogen (TN), (6) anions, (7) flow cytometry bacterial abundance data, (8) laboratory methods, and (9) a folder containing unaligned, peak-picked high resolution characterization of dissolved organic matter from sediment via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL, https://www.pnnl.gov/environmental-molecular-sciences-laboratory), and (12) a folder containing processed FTICR-MS data. All files are .msa, .txt, .spx, .xml, .csv, .pdf, .txt, .html, .jpg, or .jpeg.

18-O↗

WHONDRS Summer 2019 Sampling Campaign: Global River Corridor Sediment FTICR-MS, Dissolved Organic Carbon, Aerobic Respiration, Elemental Composition, Grain Size, Total Nitrogen and Organic Carbon Content, Bacterial Abundance, and Stable Isotopes (v10)

The WHONDRS Summer 2019 Sampling (S19S) Campaign collected samples in 97 globally distributed river corridor systems between July and September 2019. Surficial streambed sediments were collected at three locations within each site (upstream, midstream, and downstream). Surface water was collected at the downstream site. This dataset includes a portion of the data types produced from the sediment samples and does not include any results from the surface water. Surface water data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1603775. The S19S campaign was designed with the science community to ask questions associated with links among core/transient metabolomes, microbial metabolism, biogeochemical function, and physical properties of watershed and river corridor systems. This data package was originally published in December 2020. It was updated in April 2021 (v2; modified files), May 2022 (v3; new and modified files), November 2022 (v4; new and modified files), January 2023 (v5 and v6; new and modified files), February 2023 (v7; new and modified files), August 2023 (v8; new and modified files), July 2025 (v9; new and modified files), and June 2026 (v10; new and modified files). Version 10 includes major restructuring of the files and their formats. See the change history in the readme for details. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset contains (1) readme, (2) data dictionary, (3) file level metadata, (4) sampling protocol, (5) a data checks report, (6) field metadata, (7) international generic sample number (IGSN) mapping file, (8) joint genome institute (JGI) mapping file, (9) a folder of site photos, and (10) a folder of sample data. The sample data folder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and FTICR methods; (2) respiration rates and normalized respiration rates calculated from laboratory sediment incubations, (3) X-ray fluorescence (XRF) elemental composition, (4) grain size distribution from the < 2 millimeter fraction of sediment, (5) total organic carbon and total nitrogen content, (6) bacterial abundance flow cytometry data, (7) sediment stable isotopes (C and N), (8) laboratory methods, (9) water and sediment mass and volume used in incubations, (10) a folder with code, inputs, and plots for the respiration rates, (11) a folder containing XRF data, (12) a folder containing unaligned, peak-picked high resolution characterization of dissolved organic matter from sediment via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory), (12) and a folder containing processed FTICR-MS data. All files are .msa, .txt, .spx, .xml, .csv, .pdf, .txt, .jpg, or .jpeg.

13C↗

Spatial Study 2022: Surface Water Samples, Cotton Strip Degradation, and Hydrologic Sensor Data across the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin. The dataset provides data and photos generated from sample collection during the same one-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. The contents include surface water geochemistry data; river substrate grain size photos; stream depth data; manual chamber open channel respiration data; and field metadata (including qualitative information on instream and river corridor characteristics). Grain size photos can be used to improve estimates of channel substrate D50 data. The dataset also includes tensile strength and photos from cotton strip field degradation experiments; five-week sensor time series temperature, dissolved oxygen, pressure, pH, specific conductance, chlorophyll A, and turbidity data; plots of the sensor data; and R scripts used to generate the plots. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. SSS data published in the CM data package were not included in this data package. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Additionally, sensor data from a similar 2021 spatial study can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1892052 and 2021 sample data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1898914. The 2021 spatial study had some sites in common with this 2022 spatial study. This dataset is comprised of three photo folders and one main data folder with six subfolders. The photo folders contain photographs and videos of cotton strip retrieval and sediment quadrats. The main data folder consists of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) total suspended solids (TSS) data and cotton strip tensile strength data and averages; (5) field protocol; (6) readme; (7) methods codes; (8) international generic sample number (IGSN) mapping file; (9) sensor installation methods summary; (10) stream depth and averages; and (11) Ultrameter data and averages. The Sonar subfolder consists of Sonar time-series depth data and a processing script. The BarotrollAtm, DepthHOBO, MantaRiver, miniDOT, and miniDOTManualChamber subfolders contain time-series data, plots, and summary files. All files are .csv, .pdf, .txt, .R, .Rmd, .jpg, .jpeg, .AVI, .mp4, or .mov. The data package was originally published in April 2023. It was updated in August 2023 (v2; modified files) and September 2024 (v3; modified files). See the change history section in the readme for details. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Post-fire time series of sensor and geochemistry sample data from surface water, groundwater, precipitation, soil, and vegetation across Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Stream sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2 in 2024, affecting the five study sites at varying burn severities. Each site is equipped with YSI EXO2 sondes logging sub-hourly throughout the year, and grab samples are collected approximately every six weeks. YSI sondes are used to measure temporally resolved proxies for groundwater inputs (specific conductivity) and organic matter (fluorescent dissolved organic matter; fDOM) along with basic water quality and depth. Grab samples of surface water, groundwater, and precipitation are analyzed for water stable isotopes and conductivity to understand endmembers for hydrologic mixing Grab samples of surface water, groundwater, soil water, and litter/vegetation/soil leachates are analyzed for organic matter composition measured by Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) to understand organic matter dynamics. Game camera photos are provided in a separate data package available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018598. Future versions of this dataset will include time series data from YSI EXO2 sondes (fDOM, dissolved oxygen, temperature, depth, specific conductance, turbidity, pH), BaroTROLL sensors (air temperature and barometric pressure), rain gauges (precipitation), and data from the soil and vegetation samples. Because this study is ongoing, this data package will be updated regularly to include newly collected data and the additional data types. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data; (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) a data checks report; (5) file-level metadata; (6) data dictionary; (7) field metadata; (8) readme; (9) international generic sample number (IGSN) mapping file; and (10) field protocols. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) stable water isotopes and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Biogeochemistry↗

False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

09 BIOMASS FUELS↗

Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2011

This document contains the calendar year 2011 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2011, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2011.

54 ENVIRONMENTAL SCIENCES↗

Statistical Analysis Of Tank 5 Floor Sample Results (U)

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 39H (HTF-39-15-61, 62) Surface and Subsurface Supernatant Samples in Support of Corrosion Control Program

This report provides the results of analyses on Tanks 39H surface and subsurface supernatant liquid samples in support of the Corrosion Control Program. Analyses included warm acid strike preparation followed by analysis for silicon, aluminum, and sodium and water dilution preparation followed by analysis for anions. Other reported analytical results include analyses results for uranium, Pu-241 and Pu-239. The measured sodium concentration averaged, respectively, 4.28E+00 ± 9.30E-02 M and 4.32E+00 ± 1.076E-01 M in the Tank 39H surface sample and Tank 39H subsurface sample. In general, the nitrate, nitrite, free-OH and specific gravity of the Tank 39H surface and subsurface samples were all about the same in magnitude, respectively, averaging 1.98 M, 0.314 M, 1.26 M and 1.24. The measured silicon concentration for the Tank 39H surface and subsurface samples were, respectively, 3.84E+01± 5.51E+00 and 4.14E+01± 1.17E + 00 mg/L. Based on the uranium, Pu-241 and Pu-239 concentrations, the calculated U-235 equivalent is 21.41 wt% for the surface sample and 21.32 wt% for the subsurface sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pump shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample sizes for confidence limits for reliability.

We recently performed an evaluation of the implications of a reduced stockpile of nuclear weapons for surveillance to support estimates of reliability. We found that one technique developed at Sandia National Laboratories (SNL) under-estimates the required sample size for systems-level testing. For a large population the discrepancy is not important, but for a small population it is important. We found that another technique used by SNL provides the correct required sample size. For systems-level testing of nuclear weapons, samples are selected without replacement, and the hypergeometric probability distribution applies. Both of the SNL techniques focus on samples without defects from sampling without replacement. We generalized the second SNL technique to cases with defects in the sample. We created a computer program in Mathematica to automate the calculation of confidence for reliability. We also evaluated sampling with replacement where the binomial probability distribution applies.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE↗

Cluster Sampling Filters for Non-Gaussian Data Assimilation

This paper presents a fully non-Gaussian filter for sequential data assimilation. The filter is named the &ldquo;cluster sampling filter&rdquo;, and works by directly sampling the posterior distribution following a Markov Chain Monte-Carlo (MCMC) approach, while the prior distribution is approximated using a Gaussian Mixture Model (GMM). Specifically, a clustering step is introduced after the forecast phase of the filter, and the prior density function is estimated by fitting a GMM to the prior ensemble. Using the data likelihood function, the posterior density is then formulated as a mixture density, and is sampled following an MCMC approach. Four versions of the proposed filter, namely C ℓ MCMC , C ℓ HMC , MC- C ℓ HMC , and MC- C ℓ HMC are presented. C ℓ MCMC uses a Gaussian proposal density to sample the posterior, and C ℓ HMC is an extension to the Hamiltonian Monte-Carlo (HMC) sampling filter. MC- C ℓ MCMC and MC- C ℓ HMC are multi-chain versions of the cluster sampling filters C ℓ MCMC and C ℓ HMC respectively. The multi-chain versions are proposed to guarantee that samples are taken from the vicinities of all probability modes of the formulated posterior. The new methodologies are tested using a simple one-dimensional example, and a quasi-geostrophic (QG) model with double-gyre wind forcing and bi-harmonic friction. Here, numerical results demonstrate the usefulness of using GMMs to relax the Gaussian prior assumption especially in the HMC filtering paradigm.

97 MATHEMATICS AND COMPUTING↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Isotope Enrichment Detection by Laser Ablation - Laser Absorption Spectrometry: Automated Environmental Sampling and Laser-Based Analysis for HEU Detection

The global expansion of nuclear power, and consequently the uranium enrichment industry, requires the development of new safeguards technology to mitigate proliferation risks. Current enrichment monitoring instruments exist that provide only yes/no detection of highly enriched uranium (HEU) production. More accurate accountancy measurements are typically restricted to gamma-ray and weight measurements taken in cylinder storage yards. Analysis of environmental and cylinder content samples have much higher effectiveness, but this approach requires onsite sampling, shipping, and time-consuming laboratory analysis and reporting. Given that large modern gaseous centrifuge enrichment plants (GCEPs) can quickly produce a significant quantity (SQ ) of HEU, these limitations in verification suggest the need for more timely detection of potential facility misuse. The Pacific Northwest National Laboratory (PNNL) is developing an unattended safeguards instrument concept, combining continuous aerosol particulate collection with uranium isotope assay, to provide timely analysis of enrichment levels within low enriched uranium facilities. This approach is based on laser vaporization of aerosol particulate samples, followed by wavelength tuned laser diode spectroscopy to characterize the uranium isotopic ratio through subtle differences in atomic absorption wavelengths. Environmental sampling (ES) media from an integrated aerosol collector is introduced into a small, reduced pressure chamber, where a focused pulsed laser vaporizes material from a 10 to 20-µm diameter spot of the surface of the sampling media. The plume of ejected material begins as high-temperature plasma that yields ions and atoms, as well as molecules and molecular ions. We concentrate on the plume of atomic vapor that remains after the plasma has expanded and then cooled by the surrounding cover gas. Tunable diode lasers are directed through this plume and each isotope is detected by monitoring absorbance signals on a shot-to-shot basis. The media is translated by a micron resolution scanning system, allowing the isotope analysis to cover the entire sample surface. We also report, to the best of our knowledge, the first demonstration of laser-based isotopic measurements on individual micron-sized particles that are minor target components in a much larger heterogeneous mix of ‘background’ particles. This composition is consistent with swipe and environmental aerosol samples typically collected for safeguards ES purposes. Single-shot detection sensitivity approaching the femtogram range and relative isotope abundance uncertainty better than 10% has been demonstrated using gadolinium isotopes as surrogate materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of an Unattended Environmental Aerosol Sampling and Analysis System for Gaseous Centrifuge Enrichment Plants

The resources of the IAEA continue to be challenged by the rapid, worldwide expansion of nuclear energy production. Gaseous centrifuge enrichment plants (GCEPs) represent an especially formidable dilemma to the application of safeguard measures, as the size and enrichment capacity of GCEPs continue to escalate. During the early part of the 1990's, the IAEA began to lay the foundation to strengthen and make cost-effective its future safeguard regime. Measures under Part II of 'Programme 93+2' specifically sanctioned access to nuclear fuel production facilities and environmental sampling by IAEA inspectors. Today, the Additional Protocol grants inspection and environmental sample collection authority to IAEA inspectors at GCEPs during announced and low frequency unannounced (LFUA) inspections. During inspections, IAEA inspectors collect environmental swipe samples that are then shipped offsite to an analytical laboratory for enrichment assay. This approach has proven to be an effective deterrence to GCEP misuse, but this method has never achieved the timeliness of detection goals set forth by IAEA. Furthermore it is questionable whether the IAEA will have the resources to even maintain pace with the expansive production capacity of the modern GCEP, let alone improve the timeliness in reaching current safeguards conclusions. New safeguards propositions, outside of familiar mainstream safeguard measures, may therefore be required that counteract the changing landscape of nuclear energy fuel production. A new concept is proposed that offers rapid, cost effective GCEP misuse detection, without increasing LFUA inspection access or introducing intrusive access demands on GCEP operations. Our approach is based on continuous onsite aerosol collection and laser enrichment analysis. This approach mitigates many of the constraints imposed by the LFUA protocol, reduces the demand for onsite sample collection and offsite analysis, and overcomes current limitations associated with the in-facility misuse detection devices. Onsite environmental sample collection offers the ability to collect fleeting uranium hexafluoride emissions before they are lost to the ventilation system or before they disperse throughout the facility, to become deposited onto surfaces that are contaminated with background and historical production material. Onsite aerosol sample collection, combined with enrichment analysis, provides the unique ability to quickly detect stepwise enrichment level changes within the facility, leading to a significant strengthening of facility misuse deterence. We report in this paper our study of several GCEP environmental sample release scenarios and simulation results of a newly designed aerosol collection and particle capture system that is fully integrated with the Laser Ablation, Absorbance Ratio Spectrometry (LAARS) uranium particle enrichment analysis instrument that was developed at the Pacific Northwest National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method for Hot Real-Time Sampling of Gasification Products

The Thermochemical Process Development Unit (TCPDU) at the National Renewable Energy Laboratory (NREL) is a highly instrumented half-ton/day pilot scale plant capable of demonstrating industrially relevant thermochemical technologies from lignocellulosic biomass conversion, including gasification. Gasification creates primarily Syngas (a mixture of Hydrogen and Carbon Monoxide) that can be utilized with synthesis catalysts to form transportation fuels and other valuable chemicals. Biomass derived gasification products are a very complex mixture of chemical components that typically contain Sulfur and Nitrogen species that can act as catalysis poisons for tar reforming and synthesis catalysts. Real-time hot online sampling techniques, such as Molecular Beam Mass Spectrometry (MBMS), and Gas Chromatographs with Sulfur and Nitrogen specific detectors can provide real-time analysis providing operational indicators for performance. Sampling typically requires coated sampling lines to minimize trace sulfur interactions with steel surfaces. Other materials used inline have also shown conversion of sulfur species into new components and must be minimized. Sample line Residence time within the sampling lines must also be kept to a minimum to reduce further reaction chemistries. Solids from ash and char contribute to plugging and must be filtered at temperature. Experience at NREL has shown several key factors to consider when designing and installing an analytical sampling system for biomass gasification products. They include minimizing sampling distance, effective filtering as close to source as possible, proper line sizing, proper line materials or coatings, even heating of all components, minimizing pressure drops, and additional filtering or traps after pressure drops.

09 BIOMASS FUELS↗

Aleatoric and epistemic uncertainties in sampling based nuclear data uncertainty and sensitivity analyses

Sampling based uncertainty and sensitivity analyses due to epistemic input uncertainties, i.e. to an incomplete knowledge of uncertain input parameters, can be performed with arbitrary application programs to solve the physical problem under consideration. For the description of steady-state particle transport, direct simulations of the microscopic processes with Monte Carlo codes are often used. This introduces an additional source of uncertainty, the aleatoric sampling uncertainty, which is due to the randomness of the simulation process performed by sampling, and which adds to the total combined output sampling uncertainty. So far, this aleatoric part of uncertainty is minimized by running a sufficiently large number of Monte Carlo histories for each sample calculation, thus making its impact negligible as compared to the impact from sampling the epistemic uncertainties. Obviously, this process may cause high computational costs. The present paper shows that in many applications reliable epistemic uncertainty results can also be obtained with substantially lower computational effort by performing and analyzing two appropriately generated series of samples with much smaller number of Monte Carlo histories each. The method is applied along with the nuclear data uncertainty and sensitivity code package XSUSA in combination with the Monte Carlo transport code KENO-Va to various critical assemblies and a full scale reactor calculation. It is shown that the proposed method yields output uncertainties and sensitivities equivalent to the traditional approach, with a high reduction of computing time by factors of the magnitude of 100. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗