Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Robust Predictive Design of Field Measurements for Evapotranspiration Barriers Using Universal Multiple linear Regression

Surface barriers are normally installed to reduce downward water movement into contaminated zones. Specifically, evapotranspiration (ET) barriers are used to store water and release it, via ET, before it can percolate into an underlying waste zone. To assess the effectiveness of a surface barrier, we used an existing data set, model-simulated data, and a dimensionality reduction approach called universal multiple linear regression (uMLR) to optimize the required number of sensors in a 2-m thick surface barrier. To understand the usefulness of implementing predictive uMLR to accommodate multiple monitoring objectives, we compare several network designs, selected based on down-sampling of existing data, with a recommended sensor design based on model simulations performed without consideration of existing data. We further added consideration of “fuzzy” design, which allows more practical guidelines for field implementation of uMLR. We discovered that uMLR, combined with robust decision-making, provides a simple, flexible, and high-quality network design for monitoring the total water stored in a surface barrier across multiple uncertain conditions.

58 GEOSCIENCES↗

A Tutorial for Generating Correlated Random Samples in the Context of Replica Cross Section Data Used in the Propagation of Uncertainty (Second Edition)

The following sample problem write-ups are designed as a tutorial for generating correlated random samples (e.g., replica multi-group cross section data) for use in propagation of uncertainty problems. These problems were set up and solved in MATLAB, but any programming environment with basic statistical functions can be used to generate similar results. Since linear sample problems were chosen, helpful comparisons to the “sandwich” rule propagation of uncertainty are available and were used.

97 MATHEMATICS AND COMPUTING↗

Changes in the Optical Properties of Materials Are Observed After 18 Months in Low Earth Orbit

Materials located on the exterior of spacecraft in low Earth orbit are subjected to a number of environmental threats, including atomic oxygen, ultraviolet radiation, thermal cycling, and micrometeroid and debris impact. Atomic oxygen attacks materials vulnerable to oxidation. Ultraviolet radiation can break chemical bonds and cause undesirable changes in optical properties. Thermal cycling can cause cracking, and micrometeroid and debris impacts can damage protective coatings. Another threat is contamination. The outgassing of volatile chemicals can contaminate nearby surfaces, changing their thermal control properties. Contaminated surfaces may undergo further change as a result of atomic oxygen and ultraviolet radiation exposure. The Passive Optical Sample Assembly (POSA) experiment was designed as a risk mitigation experiment for the International Space Station. Samples were characterized before launch, exposed for 18 months on the exterior of Mir, and characterized upon their return. Lessons learned from POSA about the durability of material properties can be applied to the space station and other long-duration missions.

Jaworske, Donald A.↗

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular-beam gas-sampling system

A molecular beam mass spectrometer system for rocket motor combustion chamber sampling is described. The history of the sampling system is reviewed. The problems associated with rocket motor combustion chamber sampling are reported. Several design equations are presented. The results of the experiments include the effects of cooling water flow rates, the optimum separation gap between the end plate and sampling nozzle, and preliminary data on compositions in a rocket motor combustion chamber.

Young, W. S.↗

Thermophysical property measurements in electromagnetic levitators

Proper measurements of thermophysical properties of hot levitated liquid drops require the following: accurate temperature measurement (brightness measurement, emissivity measurement); precise drop shape measurements with submillisecond time resolution (density determination, rotational and vibrational shape information); precise control of drop shape (high symmetry variable gap levitators); accurate energy transfer measurements (direct measurements of energy transfer rates for defined gas flows over samples with quantitative measurements of energy transfer rates for defined flows over samples with known shapes); and precise measurements of repetitive sample motions (rapid repetitive shape measurements, frequency measurements with reflected laser light, measurements in the levitator and as a freely falling drop). Recent advances in coil design and control of sample rotation in an electromagnetic levitator are discussed with respect to the above requirements.

Hauge, Robert H.↗

NASA Lunar and Meteorite Sample Disk Program

The Lunar and Meteorite Sample Disk Program is designed for K-12 classroom educators who work in K-12 schools, museums, libraries, or planetariums. Educators have to be certified to borrow the Lunar and Meteorite Sample Disks by attending a NASA Certification Workshop provided by a NASA Authorized Sample Disk Certifier.

Foxworth, Suzanne↗

Design of B2PF: A Large Aperture Nb-Ti Dipole Magnet for the Electron-Ion Collider

Here, we present the initial design of the matching dipole B2PF, a large aperture cosine-theta magnet for the Electron-Ion Collider (EIC). First we share an optimized 2D magnet cross-section based on a double-layer design with Nb-Ti Rutherford cable. This cross-section is optimized to meet the required field quality in the 120 mm coil aperture both at the nominal operating current and considering iron saturation effects during the ramp. Next, we share a first design of the 3D coil ends optimized for windability, field quality, and minimizing the conductor peak field. Based on the resulting peak field, we evaluate the short-sample margin of the design for an operating target of 6.3 T dipole field at 1.9 K. Finally, we share an initial mechanical design study which utilizes a key-and-bladder support structure capable of adjusting magnet preload.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NTF model concept for the X-29A. Part 1: Requirements, guidelines, and design loads

A few Charpy samples containing a transverse EB weld at the V-notch location were produced. Three tensile specimens containing a transverse weld were also produced. These samples were tested at cryogenic temperatures. The welded Charpy samples resulted in average impact values of 20 ft-lb. This average value is as good as the NASA test samples with the base metal. The tensile specimens broke at slightly higher loads than had been calculated. The Charpy specimens did not come up to the prescribed level of 25 ft-lb. The results of the specimen tests are presented.

Daforno, G.↗

Advanced propulsion for the Mars Rover Sample Return Mission

The present evaluation of highly detailed advanced propulsion system design concepts for the Mars Rover Sample Return Mission proceeded by comparing a baseline chemical propulsion option with both storable and cryogenic advanced chemical propulsion alternatives and solar- and nuclear-based electric propulsion OTVs. Substantial launch mass reductions and commensurate payload mass increases were obtainable with both advanced chemical and electric propulsion cycles.

Palaszewski, Bryan↗

Small Body GN and C Research Report: G-SAMPLE - An In-Flight Dynamical Method for Identifying Sample Mass [External Release Version]

G-SAMPLE is an in-flight dynamical method for use by sample collection missions to identify the presence and quantity of collected sample material. The G-SAMPLE method implements a maximum-likelihood estimator to identify the collected sample mass, based on onboard force sensor measurements, thruster firings, and a dynamics model of the spacecraft. With G-SAMPLE, sample mass identification becomes a computation rather than an extra hardware requirement; the added cost of cameras or other sensors for sample mass detection is avoided. Realistic simulation examples are provided for a spacecraft configuration with a sample collection device mounted on the end of an extended boom. In one representative example, a 1000 gram sample mass is estimated to within 110 grams (95% confidence) under realistic assumptions of thruster profile error, spacecraft parameter uncertainty, and sensor noise. For convenience to future mission design, an overall sample-mass estimation error budget is developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

in-flight sample-mass identification↗

International Space Station (ISS) 3D Printer Performance and Material Characterization Methodology

In order for human exploration of the Solar System to be sustainable, manufacturing of necessary items on-demand in space or on planetary surfaces will be a requirement. As a first step towards this goal, the 3D Printing In Zero-G (3D Print) technology demonstration made the first items fabricated in space on the International Space Station. From those items, and comparable prints made on the ground, information about the microgravity effects on the printing process can be determined. Lessons learned from this technology demonstration will be applicable to other in-space manufacturing technologies, and may affect the terrestrial manufacturing industry as well. The flight samples were received at the George C. Marshall Space Flight Center on 6 April 2015. These samples will undergo a series of tests designed to not only thoroughly characterize the samples, but to identify microgravity effects manifested during printing by comparing their results to those of samples printed on the ground. Samples will be visually inspected, photographed, scanned with structured light, and analyzed with scanning electron microscopy. Selected samples will be analyzed with computed tomography; some will be assessed using ASTM standard tests. These tests will provide the information required to determine the effects of microgravity on 3D printing in microgravity.

Bean, Q. A.↗

Reliability approach to rotating-component design

A probabilistic methodology for designing rotating mechanical components using reliability to relate stress to strength is explained. The experimental test machines and data obtained for steel to verify this methodology are described. A sample mechanical rotating component design problem is solved by comparing a deterministic design method with the new design-by reliability approach. The new method shows that a smaller size and weight can be obtained for specified rotating shaft life and reliability, and uses the statistical distortion-energy theory with statistical fatigue diagrams for optimum shaft design. Statistical methods are presented for (1) determining strength distributions for steel experimentally, (2) determining a failure theory for stress variations in a rotating shaft subjected to reversed bending and steady torque, and (3) relating strength to stress by reliability.

Kececioglu, D. B.↗

Multiplexed Colorimetric Solid-Phase Extraction

Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

Gazda, Daniel B.↗

Probabilistic Calibration of Expensive Models using Efficiently Trained Surrogates

Calibration of computational models in the presence of uncertainty is often cast as a Bayesian inference problem and solved via sampling methods, e.g., Markov chain Monte Carlo. When the computational model is expensive, this task becomes intractable due to the large number of samples required to accurately estimate the posterior distribution of the calibration parameters. A popular solution to this problem is to use machine learning to develop a faster-to-evaluate, lower-fidelity substitute for the original model to serve as a surrogate while solving the inference problem. Although considered an offline cost, generating training data to construct this surrogate model can still be an expensive task in practice. An active learning algorithm is presented that focuses training on improving surrogate accuracy specifically in and around the bulk of the posterior distribution, as this is where the model is exercised during calibration. Candidate samples are drawn from families of distributions related to an approximation of the posterior. The sample maximizing predictive variance is then selected for evaluation by the original computational model, yielding a label for the training point. Iterating this approach increases efficiency relative to space filling designs (e.g., Latin hypercube sampling) by avoiding low probability points. Practical considerations are discussed, including the benefits of using a sequential Monte Carlo sampling approach, convergence heuristics, and the importance of both exploration and exploitation given that the true posterior is unknown a priori.

uncertainty quantification↗

De novo design of protein homodimers containing tunable symmetric protein pockets

Function follows form in biology, and the binding of small molecules requires proteins with pockets that match the shape of the ligand. For design of binding to symmetric ligands, protein homo-oligomers with matching symmetry are advantageous as each protein subunit can make identical interactions with the ligand. Here, we describe a general approach to designing hyperstable C2 symmetric proteins with pockets of diverse size and shape. We first designed repeat proteins that sample a continuum of curvatures but have low helical rise, then docked these into C2 symmetric homodimers to generate an extensive range of C2 symmetric cavities. We used this approach to design thousands of C2 symmetric homodimers, and characterized 101 of them experimentally. Of these, the geometry of 31 were confirmed by small angle X-ray scattering and 2 were shown by crystallographic analyses to be in close agreement with the computational design models. These scaffolds provide a rich set of starting points for binding a wide range of C2 symmetric compounds.

59 BASIC BIOLOGICAL SCIENCES↗

SUBOPT: A CAD program for suboptimal linear regulators

An interactive software package which provides design solutions for both standard linear quadratic regulator (LQR) and suboptimal linear regulator problems is described. Intended for time-invariant continuous systems, the package is easily modified to include sampled-data systems. LQR designs are obtained by established techniques while the large class of suboptimal problems containing controller and/or performance index options is solved using a robust gradient minimization technique. Numerical examples demonstrate features of the package and recent developments are described.

Fleming, P. J.↗