Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41

Dynamical mean field theory simulations with the adaptive sampling configuration interaction method

In the pursuit of accurate descriptions of strongly correlated quantum many-body systems, dynamical mean field theory (DMFT) has been an invaluable tool for elucidating the spectral properties and quantum phases of both phenomenological models and ab initio descriptions of real materials. Key to the DMFT process is the self-consistent map of the original system into an Anderson impurity model, the ground state of which is computed using an impurity solver. The power of the method is thus limited by the complexity of the impurity model the solver can handle. Simulating realistic systems generally requires many correlated sites. By adapting the recently proposed adaptive sampling configuration interaction (ASCI) method as an impurity solver, we enable much more efficient zero-temperature DMFT simulations. The key feature of the ASCI method is that it selects only the most relevant Hilbert space degrees of freedom to describe the ground state. This reduces the numerical complexity of the calculation, which will allow us to pursue future DMFT simulations with more correlated impurity sites than in previous works. Here, we present the ASCI-DMFT method and example calculations on the one- and two-dimensional Hubbard models that exemplify its efficient convergence and timing properties. We show that the ASCI approach is several orders of magnitude faster than the current best published ground-state DMFT simulations, which allows us to study the bath discretization error in simulations with small clusters, as well as to address cluster sizes beyond the current state of the art. Finally, our approach can also be adapted for other embedding methods such as density matrix embedding theory and self-energy embedding theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method Evaluation And Field Sample Measurements For The Rate Of Movement Of The Oxidation Front In Saltstone

The objective of this work was to develop and evaluate a series of methods and validate their capability to measure differences in oxidized versus reduced saltstone. Validated methods were then applied to samples cured under field conditions to simulate Performance Assessment (PA) needs for the Saltstone Disposal Facility (SDF). Four analytical approaches were evaluated using laboratory-cured saltstone samples. These methods were X-ray absorption spectroscopy (XAS), diffuse reflectance spectroscopy (DRS), chemical redox indicators, and thin-section leaching methods. XAS and thin-section leaching methods were validated as viable methods for studying oxidation movement in saltstone. Each method used samples that were spiked with chromium (Cr) as a tracer for oxidation of the saltstone. The two methods were subsequently applied to field-cured samples containing chromium to characterize the oxidation state of chromium as a function of distance from the exposed air/cementitious material surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sampling system and method

The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sampling system and method

In one embodiment, the present disclosure provides an apparatus and method for supporting a tubing bundle during installation or removal. The apparatus includes a clamp for securing the tubing bundle to an external wireline. In various examples, the clamp is external to the tubing bundle or integral with the tubing bundle. According to one method, a tubing bundle and wireline are deployed together and the tubing bundle periodically secured to the wireline using a clamp. In another embodiment, the present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit. In a specific example, one or more clamps are used to connect the first and/or second conduits to an external wireline.

42 ENGINEERING↗

A Separation Voltage Polarity Switching Method for Higher Sample Loading Capacity and Better Separation Resolution in Transient Capillary Isotachophoresis Separation

A separation voltage polarity switching transient capillary isotachophoresis (PS-tCITP) was developed to overcome a major sample loading volume limitation in transient capillary isotachophoresis (tCITP). The fundamental idea of PS-tCITP is to let sample ions move back and forth in the separation capillary during their initial isotachophoresis focusing stage by switching the polarity of separation voltage, in order to both increase the sample loading volume and improve the separation efficiency as compared to the conventional tCITP method. The experimental evaluation of the novel PS-tCITP method by using two peptide standards at 2 µM concentration showed that the maximum sample loading volume could be increased from 45% of the total separation capillary volume in tCITP to 70% in PS-tCITP, which resulted in a more than 1.5 fold increases in the peptide peak intensity at a given length/volume of the separation capillary. Due to the consecutive focusing of sample volume from each polarity switching of separation voltage, the separation time window at a given sample loading volume was also increased significantly in PS-tCITP as compared to tCITP. Experiment comparison between tCITP and PS-tCITP at 45% sample loading volume using the same setup showed that the migration time difference between the two peptide peaks increased from 0.3 min in tCITP to 0.363 min in PS-tCITP with similar peak widths and heights, resulting in roughly a 21% improvement in separation resolution. The performance advantages of PS-tCITP separation over tCITP separation was further verified by using a mixture of six peptide standards.

Wu, Huanming↗

Compositions and Methods Associated with Intercalating and Exfoliating a Sample

Compositions and methods associated with intercalating and exfoliating a sample are described herein. For example, of a method may include mixing the sample with intercalation materials. The intercalation materials are then intercalated into the sample to obtain a sample intercalated with the intercalation materials. The intercalated sample can then be exfoliated to produce an exfoliated sample.

Hung, Ching-Cheh↗

CASSCF with Extremely Large Active Spaces Using the Adaptive Sampling Configuration Interaction Method

The complete active space self-consistent field (CASSCF) method is the principal approach employed for studying strongly correlated systems. However, exact CASSCF can only be performed on small active spaces of ~20 electrons in ~20 orbitals due to exponential growth in the computational cost. Here, we show that employing the Adaptive Sampling Configuration Interaction (ASCI) method as an approximate Full CI solver in the active space allows CASSCF-like calculations within chemical accuracy (<1 kcal/mol for relative energies) in active spaces with more than ~50 active electrons in ~50 active orbitals, significantly increasing the sizes of systems amenable to accurate multiconfigurational treatment. The main challenge with using any selected CI-based approximate CASSCF is the orbital optimization problem; they tend to exhibit large numbers of local minima in orbital space due to their lack of invariance to active–active rotations (in addition to the local minima that exist in exact CASSCF). We highlight methods that can avoid spurious local extrema as a practical solution to the orbital optimization problem. We employ ASCI-SCF to demonstrate a lack of polyradical character in moderately sized periacenes with up to 52 correlated electrons and compare against heat-bath CI on an iron porphyrin system with more than 40 correlated electrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high contrast method of unstained biological samples under a thin carbon film by scanning electron microscopy

The contrast of biological samples in scanning electron microscopy (SEM) is very weak. To examine a biological specimen by SEM, many steps and/or special equipment are required to prepare the sample. Here, we describe a method using an unstained biological sample under a 40 nm carbon film to give a high contrast image, where the image is detected by the secondary electron (SE) signal at a low accelerating voltage of 1.5 kV. Under these conditions, it is hard to detect a direct signal from a biological specimen. The high contrast image is created by the SEs from the lower surface of the thin carbon film. Therefore, the damage to the sample from the electron beam is very low. Our method can be utilized to observe various biological samples of bacteria, viruses, and protein complexes.

60 APPLIED LIFE SCIENCES↗

Drum plug piercing and sampling device and method

An apparatus and method for piercing a drum plug of a drum in order to sample and/or vent gases that may accumulate in a space of the drum is provided. The drum is not damaged and can be reused since the pierced drum plug can be subsequently replaced. The apparatus includes a frame that is configured for engagement with the drum. A cylinder actuated by a fluid is mounted to the frame. A piercer is placed into communication with the cylinder so that actuation of the cylinder causes the piercer to move in a linear direction so that the piercer may puncture the drum plug of the drum.

47 OTHER INSTRUMENTATION↗

Interpretable Machine Learning for Molecular Biosignatures: a Novel Single-Sample Feature Importance Method That Is Sensitive To Statistical Interactions

Isotope ratio mass spectrometry (IRMS) of volatiles (e.g., CO 2 ) promises to be a powerful tool for potential biosignature detection for future missions to ocean worlds (OW) such as Europa and Enceladus. Machine learning (ML) methods for IRMS data could enable science autonomy by onboard prediction of seawater chemistry and biosignature presence. However, ML models are likely to be complex and involve statistical interactions between features (variables), which can make predictions seem opaque and enigmatic. For ML predictions as significant as extraterrestrial biosignatures, we must place extraordinary confidence in models. It is therefore essential that these models make interpretable predictions (i.e., human-understandable) and include false-prediction diagnostics. We achieve high accuracy and interpretability in ML biosignature and seawater chemistry models for OW through a nearest-neighbors feature selection tool that detects statistical interactions between predictors, constructs interaction networks for visualization of selected features working together to make a prediction, and reports single-sample feature importance scores for false-detection diagnostics. Here we develop a novel single-sample nearest-neighbors projected distance regression(ssNPDR) feature selection method that improves upon existing single-sample algorithms through the inclusion of statistical interactions while providing false-prediction diagnostics for ML models.

geochemistry↗

Developing a New Sampling And Analysis Method For Hydrazine And Monomethyl Hydrazine: Using a Derivatizing Agent With Solid Phase Microextraction

Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCI), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.

Allen, John↗

Developing A New Sampling and Analysis Method for Hydrazine and Monomethyl Hydrazine

Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCl), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.

Allen, John R.↗

Flow through in situ reactors with suction lysimeter sampling capability and methods of using

An in situ reactor for use in a geological strata includes a liner defining a centrally disposed passageway and a sampling conduit received within the passageway. The sampling conduit may be used to receive a geological speciment derived from geological strata therein and a lysimeter is disposed within the sampling conduit in communication with the geological specimen. Fluid may be added to the geological specimen through the passageway defined by the liner, between an inside surface of the liner and an outside surface of the sampling conduit. A distal portion of the sampling conduit may be in fluid communication with the passageway.

47 OTHER INSTRUMENTATION↗

A Multilevel, Hierarchical Sampling Technique for Spatially Correlated Random Fields

In this paper, we propose an alternative method to generate samples of a spatially correlated random field with applications to large-scale problems for forward propagation of uncertainty. A classical approach for generating these samples is the Karhunen--Loève (KL) decomposition. However, the KL expansion requires solving a dense eigenvalue problem and is therefore computationally infeasible for large-scale problems. Sampling methods based on stochastic partial differential equations provide a highly scalable way to sample Gaussian fields, but the resulting parametrization is mesh dependent. We propose a multilevel decomposition of the stochastic field to allow for scalable, hierarchical sampling based on solving a mixed finite element formulation of a stochastic reaction-diffusion equation with a random, white noise source function. Lastly, numerical experiments are presented to demonstrate the scalability of the sampling method as well as numerical results of multilevel Monte Carlo simulations for a subsurface porous media flow application using the proposed sampling method.

97 MATHEMATICS AND COMPUTING↗

A parallel, distributed memory implementation of the adaptive sampling configuration interaction method

The many-body simulation of quantum systems is an active field of research that involves several different methods targeting various computing platforms. Many methods commonly employed, particularly coupled cluster methods, have been adapted to leverage the latest advances in modern high-performance computing. Selected configuration interaction (sCI) methods have seen extensive usage and development in recent years. However, the development of sCI methods targeting massively parallel resources has been explored only in a few research works. Here, we present a parallel, distributed memory implementation of the adaptive sampling configuration interaction approach (ASCI) for sCI. In particular, we will address the key concerns pertaining to the parallelization of the determinant search and selection, Hamiltonian formation, and the variational eigenvalue calculation for the ASCI method. Load balancing in the search step is achieved through the application of memory-efficient determinant constraints originally developed for the ASCI-PT2 method. The presented benchmarks demonstrate near optimal speedup for ASCI calculations of Cr 2 (24e, 30o) with 10 6 , 10 7 , and 3 × 10 8 variational determinants on up to 16 384 CPUs. Importantly, to the best of the authors’ knowledge, this is the largest variational ASCI calculation to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Improved Sampling and Baiting Method for Phytophthora tropicalis and P. heveae Detection in Macadamia integrifolia

Macadamia nuts are, economically, the second most important crop in the state of Hawai’i. A recent decline in yield and acreage has been attributed to insect damage and diseases such as Macadamia Quick Decline (MQD) caused by Phytophthora tropicalis and P. heveae. To develop an improved methodology for the diagnosis and treatment of MQD, investigations were undertaken to better understand the pathosystem of the disease. These investigations included sampling from multiple locations from sectioned trees utilizing two methods of tissue collection and isolations using two baiting techniques. The collection of tissue from the cambium and phloem of trees after scraping away the bark and in locations of recent or current sap exudation using a narrow diameter steel awl proved to be an efficient means for the molecular detection of the MQD pathogens from infected trees exhibiting MQD symptoms. In addition, a more efficient and cost-effective baiting method using apple puree was developed.

Plant Sciences↗

An adaptive sampling augmented Lagrangian method for stochastic optimization with deterministic constraints

The primary goal of this paper is to provide an efficient solution algorithm based on the augmented Lagrangian framework for optimization problems with a stochastic objective function and deterministic constraints. Our main contribution is combining the augmented Lagrangian framework with adaptive sampling, resulting in an efficient optimization methodology validated with practical examples. To achieve the presented efficiency, here we consider inexact solutions for the augmented Lagrangian subproblems, and through an adaptive sampling mechanism, we control the variance in the gradient estimates. Furthermore, we analyze the theoretical performance of the proposed scheme by showing equivalence to a gradient descent algorithm on a Moreau envelope function, and we prove sublinear convergence for convex objectives and linear convergence for strongly convex objectives with affine equality constraints. The worst-case sample complexity of the resulting algorithm, for an arbitrary choice of penalty parameter in the augmented Lagrangian function, is $\mathscr{O}$(ϵ -3-δ ) , where ϵ > 0 is the expected error of the solution and δ > 0 is a user-defined parameter. If the penalty parameter is chosen to be $\mathscr{O}$(ϵ -1 ), we demonstrate that the result can be improved to $\mathscr{O}$(ϵ -2 ) , which is competitive with the other methods employed in the literature. Moreover, if the objective function is strongly convex with affine equality constraints, we obtain $\mathscr{O}$(ϵ -1 log(1/ϵ)) complexity. Finally, we empirically verify the performance of our adaptive sampling augmented Lagrangian framework in machine learning optimization and engineering design problems, including topology optimization of a heat sink with environmental uncertainty.

97 MATHEMATICS AND COMPUTING↗